Construction Of New A Site Ro At Tlabung

Tender Notice

26109184
Construction Of New A Site Ro At Tlabung
Indian
Mizoram
27-11-2020
08-12-2020
09-12-2020

Tender Details

Construction Of New A Site Ro At Tlabung

Key Value

Document Fees
Refer document
EMD
INR 121000.00 /-
Tender Value
Refer document

BOQ Items

Name of Work: Construction of New “A” Site RO at Tlabung, Dist. Lunglei, Mizoram
Sl. No. Item Description Item Code / Make Quantity Units
1 1 IINSTALLATION OF 2X20 KL TANK IN EARTHPIT BI01010001010000000000000515BI0100001112
2 2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001113
3 3 ii) Ordinary rock BI01010001010000000000000515BI0100001114 27 M3
4 4 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth BI01010001010000000000000515BI0100001115 20 M2
5 5 Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : BI01010001010000000000000515BI0100001116
6 6 iii) PCC 1 Cement:2 Coarse Sand:4 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001117 2 M3
7 7 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001118
8 8 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001119 5 M3
9 9 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001120
10 10 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001121 350 KG
11 11 Centering and shuttering including strutting, propping etc. and removal of form work for: BI01010001010000000000000515BI0100001122
12 12 i) Foundations,footings,bases of column BI01010001010000000000000515BI0100001123 50 M2
13 13 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001124
14 14 i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001125 8 M3
15 15 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. BI01010001010000000000000515BI0100001126
16 16 i) Local Fine Sand within grading zone IV BI01010001010000000000000515BI0100001127 30 M3
17 17 Providing and laying cement plaster on surfaces with fine sand including curing etc. BI01010001010000000000000515BI0100001128
18 18 i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) BI01010001010000000000000515BI0100001129 54 M2
19 19 Finishing walls with Acrylic Smooth exterior paint of required shade (2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm) BI01010001010000000000000515BI0100001130 54 M2
20 20 Supplying and installation of the following threaded BI01010001010000000000000515BI0100001131
21 21 i) 80 mm dia Aluminium camlock coupling - Male only BI01010001010000000000000515BI0100001132 2 EA
22 22 Transportation of equipment from one location to another location including enroute all taxes, levies and unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank same shall be loaded by the tank fabrication contractor) BI01010001010000000000000515BI0100001133
23 23 iii) 15/20 KL Tank with fittings : 0 - 30 Km BI01010001010000000000000515BI0100001134 2 LS
24 24 iv) 15/20 KL Tank with fittings: Add extra for each addtnl. Km above 30km BI01010001010000000000000515BI0100001135 1450 KM
25 25 Installation of supplied 20 KL Tank as per specified drawings as per work description but excluding all works of kerb wall and Gasket for manhole including painting / doping with Shalimastic HD as applicable as per specifications complete. RCC works wherever mentioned shall be of grade M20 BI01010001010000000000000515BI0100001136
26 26 ii) In earth pit with RCC matt raft as per standard Drg. ENG/314 BI01010001010000000000000515BI0100001137 2 LS
27 27 Supply and Laying of 80 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling & back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125. BI01010001010000000000000515BI0100001138 42 M
28 28 Supply, fabrication, laying and testing of MS black, ERW welded, pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping BI01010001010000000000000515BI0100001139
29 29 ii) S/L Welded U/G HD MS Pipes of 80mm dia with fittings,doping BI01010001010000000000000515BI0100001140 12 M
30 30 Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job) BI01010001010000000000000515BI0100001141 2 EA
31 31 Supply and fixing Pressure Vacuum Valves of 2 inches for fixing to the Vent Pipes of Underground MS tanks. The valve should be in closed position at normal operating pressure of the tank. The Valve shall be capable for activation at set pressure of 3" ± 0.5 water column to release excess pressure of tank to the atmosphere and open at vacuum of 8" ± 2.0 water column to induce the atmosphere pressure to the tank. PV valve should be diaphragm of dead weight or spring loaded type or combination of any. The weight of the PV valve shall not exceed 2.0 kg. top of the valve shall be provided with cover/cap/ weather hood to prevent the entry of rain water. Valve material,Cover and adopter shall be of Aluminium/polypropylene, diaphragm if used should be of Neoprene, O ring should be of rubber/neoprene, Net/Mesh Pressure puppet ,Vacuum puppet,screws and spring should be of stainless steel. Suitable adopter with one end fitted with valve and the other end should have threading for fixing on Vent pipe of 40mm. PV valves shall have: UL 842 certification of CARB approval or test certificate from any Govt.lab. PV valve shall have PESO approval. BI01010001010000000000000515BI0100001142 1 EA
32 32 Supply and installation of ‘U’ type CS bend on the vent pipes including painting as per specifications and supplying and brazing wire mesh of 11 mesh per linear centi-meter of non-corrosive metal in two layers on both ends. BI01010001010000000000000515BI0100001143
33 33 i) Supply & installation of U type CS bend on vent pipe of 80 mm dia BI01010001010000000000000515BI0100001144 1 EA
34 34 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001145
35 35 ii) Ordinary rock BI01010001010000000000000515BI0100001146 7 M3
36 36 Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : BI01010001010000000000000515BI0100001147
37 37 iv) PCC 1 Cement:2 Coarse Sand:4 Graded Stone Aggregate 40mm BI01010001010000000000000515BI0100001148 1 M3
38 38 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001149
39 39 i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001150 10 M3
40 40 Providing and laying cement plaster on surfaces with fine sand including curing etc. BI01010001010000000000000515BI0100001151
41 41 i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) BI01010001010000000000000515BI0100001152 45 M2
42 42 Providing Neat cement punning BI01010001010000000000000515BI0100001153 18 M2
43 43 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: BI01010001010000000000000515BI0100001154 380 KG
44 44 MPD AND STP INSTALLATION BI01010001010000000000000515BI0100001155
45 45 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001156
46 46 ii) Ordinary rock BI01010001010000000000000515BI0100001157 10 M3
47 47 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. BI01010001010000000000000515BI0100001158
48 48 i) Local Fine Sand within grading zone IV BI01010001010000000000000515BI0100001159 2 M3
49 49 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001160
50 50 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001161 1.5 M3
51 51 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. BI01010001010000000000000515BI0100001162
52 52 iv) Granite of any colour and shade having Area of slab over 0.50 sqm BI01010001010000000000000515BI0100001163 15 M2
53 53 Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete. BI01010001010000000000000515BI0100001164 10 M2
54 54 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001165
55 55 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001166 6 M3
56 56 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001167
57 57 viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001168 4 M2
58 58 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks BI01010001010000000000000515BI0100001169 10 M2
59 59 Supply and Laying of 50 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling & back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125. BI01010001010000000000000515BI0100001170 55 M
60 60 Supply, fabrication, laying and testing of MS black, ERW welded, pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping BI01010001010000000000000515BI0100001171
61 61 iii) S/L Welded U/G HD MS Pipes of 50mm dia with fittings,doping BI01010001010000000000000515BI0100001172 12 M
62 62 Supplying and installation of the following threaded Caps conforming to detailed specification BI01010001010000000000000515BI0100001173
63 63 i) S/I of Threaded caps of 50 mm dia for dip pipe BI01010001010000000000000515BI0100001174 2 EA
64 64 Supply and installation of screwed type gun metal valves as per IOC specifications: Ball Valve BI01010001010000000000000515BI0100001175
65 65 iii) S/I Screwed type GM Ball Valve of 50 mm dia BI01010001010000000000000515BI0100001176 6 EA
66 66 Installation of supplied Multi Product Pumps / Dispensers on pump island as per manufacturers installation manual, drawings, including supplying, providing necessary frame of ISMC 100, foundation bolts, supplying and filling required quantity of dry sand in pit(s) below the pump BI01010001010000000000000515BI0100001177
67 67 i) 2 product - 4 nozzle MPPs/MPDs BI01010001010000000000000515BI0100001178 2 EA
68 68 Transportation of equipment from one location to another location including enroute all taxes, levies and unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank same shall be loaded by the tank fabrication contractor) BI01010001010000000000000515BI0100001179
69 69 xii) MPD/MPP pumps upto 2 nos., 0-30 Km BI01010001010000000000000515BI0100001180 1 LS
70 70 xii) MPD/MPP pumps upto 2 nos., Add extra for every additional Km above 30km BI01010001010000000000000515BI0100001181 850 KM
71 71 viii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos,0-30 Km BI01010001010000000000000515BI0100001182 1 LS
72 72 ix) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos, Add extra for every additional Km above 30km BI01010001010000000000000515BI0100001183 850 KM
73 73 Supply & welding slip-on flanges conforming to IS2062 GrA, ANSI B16.5, Class#150 with 3 runs of weld outside and one run of weld inside the flanges as per specifications and standard Drg.enclosed herein BI01010001010000000000000515BI0100001184
74 74 ii) S/W Slipon flanges of 80 mm dia conforming to IS2062 GrA, ANSI B16.5,Class 150 as per specifications and standard Drg.enclosed herein BI01010001010000000000000515BI0100001185 8 EA
75 75 Installation of Corporation supplied Standard Submersible Turbine Pump on the existing Manhole Cover as per drawing and direction of Engineer in Charge BI01010001010000000000000515BI0100001186 2 EA
76 76 Providing alteration to Manhole Covers for Fixing Submersible Turbine Including Fixing of 100mm diax 150 to 200mm long C class threaded Barrel Nipple , 100mm dia x 100 mm long coupler , 2 nos 100mm dia Class 150 threaded MS flange, 3mm thick packing sheet, nuts and bolts, 3mm thick permanite oil packing gasket to manhole cover, cutting of the manhole cover for fixing nipples etc. at workshop including transportation etc. BI01010001010000000000000515BI0100001187 2 EA
77 77 DU ELECTRIFICATION BI01010001010000000000000515BI0100001188
78 78 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty BI01010001010000000000000515BI0100001189
79 79 ii) 150 mm dia. R.C.C. pipe BI01010001010000000000000515BI0100001190 35 M
80 80 CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001191
81 81 vi) 3 Core x 1.5 sq. mm. BI01010001010000000000000515BI0100001192 4 EA
82 82 vii) 3 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001193 4 EA
83 83 FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001194
84 84 vii) 3 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001195 8 EA
85 85 vi) 3 Core x 1.5 sq. mm. BI01010001010000000000000515BI0100001196 8 EA
86 86 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001197
87 87 iii) 3 Core x 1.5 sq. mm. (copper) BI01010001010000000000000515BI0100001198 150 M
88 88 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS BI01010001010000000000000515BI0100001199 300 M
89 89 Supplying and fixing of following MCBs with necessery inter connections on existing DB, Panel board etc. BI01010001010000000000000515BI0100001200
90 90 ii) Upto 32A DP MCB BI01010001010000000000000515BI0100001201 10 EA
91 91 Supply and installation of MCB distribution board having Double door complete with tinned cu bus bar, neutral bus bar, earth bar, din bar, interconnection, earthing etc. without incoming isolator and MCBs BI01010001010000000000000515BI0100001202
92 92 iii) 2+12 way SPN BI01010001010000000000000515BI0100001203 2 EA
93 93 SINGLE SERVO VOLTAGE STABILISER Supply and fixing of 230V, Single phase, AC Servo voltage stabilizer of approved makes,(Range - 180 - 250 minimum) shall be provided for Individual dispensing pump as per IE Regulation and as per specification BI01010001010000000000000515BI0100001204
94 94 iv) 5KVA stabilizer BI01010001010000000000000515BI0100001205 2 EA
95 95 CONSTANT VOLTAGE TRANSFORMER Supplying, installation, testing and commissioning of single phase, air cooled constant voltage transformer of approved make having input voltage range of 180-260V and output voltage of 220/230V with sine wave output wave form and having automatic current limiting and short circuit protection including all accessories complete (for displays) for the following VA ratings. BI01010001010000000000000515BI0100001206
96 96 iii) 500VA CVT BI01010001010000000000000515BI0100001207 2 EA
97 97 SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge. BI01010001010000000000000515BI0100001208
98 98 viii) 15 A Modular switch BI01010001010000000000000515BI0100001209 6 EA
99 99 x) 15 A 6 Pin Modular socket BI01010001010000000000000515BI0100001210 6 EA
100 100 iv) 6 module frame BI01010001010000000000000515BI0100001211 3 EA
101 101 Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make BI01010001010000000000000515BI0100001212
102 102 i) 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire BI01010001010000000000000515BI0100001213 50 M
103 103 Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : BI01010001010000000000000515BI0100001214
104 104 vi) 8 S.W.G. G.I. Wire (bare) BI01010001010000000000000515BI0100001215 80 M
105 105 i) 50 x 10mm G.I. Strip BI01010001010000000000000515BI0100001216 90 M
106 106 ii) 32 x 6 mm G.I.strip BI01010001010000000000000515BI0100001217 120 M
107 107 v) 25 x 3 mm GI strip BI01010001010000000000000515BI0100001218 200 M
108 108 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: BI01010001010000000000000515BI0100001219 30 KG
109 109 Lettering with black japan paint of approved brand & manufacture and (unit/letter/cm ht) BI01010001010000000000000515BI0100001220 150 EA
110 110 Supply & fixing of 300mA RCCB of approved Make of following ratings: BI01010001010000000000000515BI0100001221
111 111 ii) 2 poles, 40A BI01010001010000000000000515BI0100001222 2 EA
112 112 Chemical Earthing with Copper Bonded Rod suitable for current carrying capacity of 15kA for 1 second - Supply of chemical earthing Cu Bonded High Tensile Low Carbon Steel Rod of dia not less than 17mm electrode complying to UL 467 Requirements & suitable for current carrying capacity of 15kA for 1 second, exothermic welded & 3Mtr long BI01010001010000000000000515BI0100001223 2 EA
113 113 YARD LIGHTING (7 NOS) BI01010001010000000000000515BI0100001224
114 114 Providing and laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen BI01010001010000000000000515BI0100001225 55 M
115 115 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001226
116 116 i) All kinds of Soil BI01010001010000000000000515BI0100001227 10.5 M3
117 117 Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : BI01010001010000000000000515BI0100001228
118 118 iv) PCC 1 Cement:2 Coarse Sand:4 Graded Stone Aggregate 40mm BI01010001010000000000000515BI0100001229 1 M3
119 119 Centering and shuttering including strutting, propping etc. and removal of form work for: BI01010001010000000000000515BI0100001230
120 120 i) Foundations,footings,bases of column BI01010001010000000000000515BI0100001231 26 M2
121 121 Supplying and providing 100mm square hensel weather proof junction box for emblem pole/ light pole/yard light BI01010001010000000000000515BI0100001232 7 EA
122 122 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001233
123 123 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS BI01010001010000000000000515BI0100001234 200 M
124 124 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001235
125 125 xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS BI01010001010000000000000515BI0100001236 24 M
126 126 FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001237
127 127 vii) 3 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001238 7 EA
128 128 Supplying & drawing inside the poles 3 core 2.5 sq.mm PVC insulated flexible copper conductor, fixing of junction box at the pole base (excluding supply of JB), making all connections on both ends, all complete as per specification and direction of Engineer In-charge. BI01010001010000000000000515BI0100001239
129 129 ii) "L" Pole BI01010001010000000000000515BI0100001240 7 EA
130 130 OCTAGONAL POLES Supply & Fixing of Octagonal Poles of following type (Civil job shall be paid separatly) : BI01010001010000000000000515BI0100001241
131 131 iii) S/E of 5 Meter high galvanised Octagonal pole with top 60mm(A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 210 x 210 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides) BI01010001010000000000000515BI0100001242 7 EA
132 132 FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001243
133 133 xviii) 3.5 Core x 50 sq. mm BI01010001010000000000000515BI0100001244 7 EA
134 134 Supply, fitting, fixing of arm bracket, tubular type, 38mm/50mm dia on pole including painting, all complete. BI01010001010000000000000515BI0100001245
135 135 i) S/E Arm " L " bracket 38/50mm dia on pole, as per specifications and direction of Engineer in charge BI01010001010000000000000515BI0100001246 7 EA
136 136 Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001247 7 EA
137 137 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001248
138 138 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001249 280 KG
139 139 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001250
140 140 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001251 5 M3
141 141 AIR FACILITY (100% ITC) BI01010001010000000000000515BI0100001252
142 142 Tyre Inflator Supply & installation of Digital tyre inflator which is microprocessor based, automatic air pressure controller with solenoid controlled nozzle for automatic fill and release functions. Complete with weather proof cabinet, 3 digit LED displays with backlight illuminations i.e. one for actual tyre pressure and another for set pressure. Air filter, remote controller, cables, PVC hose pipe and working pressure upto 10bar (Excluding civil work for foundation,etc.) BI01010001010000000000000515BI0100001253 1 EA
143 143 Providing and fixing B class G.I. pipes complete with G.I. fittings & clamps, i/c cutting & making good the walls etc. Internal work Exposed on wall. BI01010001010000000000000515BI0100001254
144 144 iii) 25 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001255 10 M
145 145 FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001256
146 146 vii) 3 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001257 2 EA
147 147 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001258
148 148 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS BI01010001010000000000000515BI0100001259 100 M
149 149 Air compressor Supply and installation of horizontal air compressor assembly with delivery pressure of 12 kg/sq cm equipped with pressure gauge, non- return/safety/drain/delivery valves, automatic cut-off switch and suitable electrical connections & all standard accessories, including civil works: BI01010001010000000000000515BI0100001260
150 150 iii) Horizontal air compressor Assembly of 5 HP (160-220 LITRES) including civil works BI01010001010000000000000515BI0100001261 1 EA
151 151 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001262
152 152 ii) Ordinary rock BI01010001010000000000000515BI0100001263 1 M3
153 153 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001264
154 154 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001265 2 M3
155 155 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty BI01010001010000000000000515BI0100001266
156 156 ii) 150 mm dia. R.C.C. pipe BI01010001010000000000000515BI0100001267 30 M
157 157 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001268
158 158 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001269 2 M3
159 159 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001270
160 160 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001271 150 KG
161 161 Providing and laying cement plaster on surfaces with Coarse sand including curing etc. BI01010001010000000000000515BI0100001272
162 162 ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand) BI01010001010000000000000515BI0100001273 11 M2
163 163 Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete. BI01010001010000000000000515BI0100001274 7 M2
164 164 UNIPOLE FOUNDATION BI01010001010000000000000515BI0100001275
165 165 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001276
166 166 ii) Ordinary rock BI01010001010000000000000515BI0100001277 7 M3
167 167 Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : BI01010001010000000000000515BI0100001278
168 168 iv) PCC 1 Cement:2 Coarse Sand:4 Graded Stone Aggregate 40mm BI01010001010000000000000515BI0100001279 1 M3
169 169 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001280
170 170 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001281 2 M3
171 171 Centering and shuttering including strutting, propping etc. and removal of form work for: BI01010001010000000000000515BI0100001282
172 172 i) Foundations,footings,bases of column BI01010001010000000000000515BI0100001283 10 M2
173 173 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001284
174 174 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001285 120 KG
175 175 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001286
176 176 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001287 2 M3
177 177 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall BI01010001010000000000000515BI0100001288
178 178 vi) 50 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001289 1 M
179 179 Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge : BI01010001010000000000000515BI0100001290
180 180 iv) 20mm dia x 900mm long with 100 mm dia x 6 mm thick plate BI01010001010000000000000515BI0100001291 8 EA
181 181 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items BI01010001010000000000000515BI0100001292
182 182 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS BI01010001010000000000000515BI0100001293 70 M
183 183 CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. BI01010001010000000000000515BI0100001294
184 184 vii) 3 Core x 2.5 sq. mm BI01010001010000000000000515BI0100001295 2 EA
185 185 Providing, fixing, testing and commissioning of FLP junction box of approved make for cable connection/ jointing. BI01010001010000000000000515BI0100001296
186 186 i) For cables 2.5 to 4 sqmm XLPE / AYFY BI01010001010000000000000515BI0100001297 1 EA
187 187 Supplying and fixing of following MCBs with necessery inter connections on existing DB, Panel board etc. BI01010001010000000000000515BI0100001298
188 188 ii) Upto 32A DP MCB BI01010001010000000000000515BI0100001299 2 EA
189 189 Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete. BI01010001010000000000000515BI0100001300 2 M2
190 190 DRIVEWAY WITH EDGE RESTRAINTS BI01010001010000000000000515BI0100001301
191 191 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001302
192 192 ii) Ordinary rock BI01010001010000000000000515BI0100001303 27 M3
193 193 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth within premises BI01010001010000000000000515BI0100001304 540 M2
194 194 Supply and laying of water bound macadam of 100 mm consolidated thickness for subbase with 90 to 45 mm stone aggregate,11.2mm size screenings, chippings of stone and murrum spreading, watering and consolidating in camber with power roller complete as/specifications. BI01010001010000000000000515BI0100001305 540 M2
195 195 Supply and laying of water bound macadam in layers, each of 75 mm thick (consolidated) with 63 mm to 45 mm stone aggregate. Each layer shall be consolidated by power roller after watering, spreading chippings of stone and murrum complete as per specifications. Item includes supply of murrum 6 mm thick, watering and rolling with power roller complete with preparation of surface. Rate per Layer BI01010001010000000000000515BI0100001306 1080 M2
196 196 Providing & laying factory made Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih strong vibratory compaction & of approved size and design / shape, shade and manufacturers and as per IOCL's specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658, maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881 maximum dimensional deviations of +/- 3mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete. BI01010001010000000000000515BI0100001307
197 197 ii) M40 grade 80 mm thick Plain finish BI01010001010000000000000515BI0100001308 540 M2
198 198 Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plant at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired density, complete as per specification & direction of Engineer-in-charge. BI01010001010000000000000515BI0100001309
199 199 ii) With material confirming to grade-II (size 53 mm to .075 mm) having CBR value -25,Thickness as desired BI01010001010000000000000515BI0100001310 237.6 M3
200 200 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. BI01010001010000000000000515BI0100001311 120 M2
201 201 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001312
202 202 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001313 7 M3
203 203 Centering and shuttering including strutting, propping etc. and removal of form work for: BI01010001010000000000000515BI0100001314
204 204 i) Foundations,footings,bases of column BI01010001010000000000000515BI0100001315 100 M2
205 205 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001316
206 206 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001317 8 M3
207 207 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001318
208 208 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001319 950 KG
209 209 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001320
210 210 i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001321 10 M3
211 211 Providing and laying cement plaster on surfaces with fine sand including curing etc. BI01010001010000000000000515BI0100001322
212 212 i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) BI01010001010000000000000515BI0100001323 120 M2
213 213 CONSTRUCTION OF BUFFER STRIP BI01010001010000000000000515BI0100001324
214 214 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001325
215 215 ii) Ordinary rock BI01010001010000000000000515BI0100001326 4 M3
216 216 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001327
217 217 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001328 1 M3
218 218 Centering and shuttering including strutting, propping etc. and removal of form work for: BI01010001010000000000000515BI0100001329
219 219 i) Foundations,footings,bases of column BI01010001010000000000000515BI0100001330 15 M2
220 220 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001331
221 221 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001332 4 M3
222 222 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks BI01010001010000000000000515BI0100001333 5 M2
223 223 Providing and laying cement plaster on surfaces with fine sand including curing etc. BI01010001010000000000000515BI0100001334
224 224 i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) BI01010001010000000000000515BI0100001335 35 M2
225 225 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. BI01010001010000000000000515BI0100001336 35 M2
226 226 CONSTRUCTION OF SALES BUILDING BI01010001010000000000000515BI0100001337
227 227 Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : BI01010001010000000000000515BI0100001338
228 228 iv) PCC 1 Cement:2 Coarse Sand:4 Graded Stone Aggregate 40mm BI01010001010000000000000515BI0100001339 5 M3
229 229 vi) PCC 1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 40mm BI01010001010000000000000515BI0100001340 6 M3
230 230 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks BI01010001010000000000000515BI0100001341 60 M2
231 231 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil BI01010001010000000000000515BI0100001342 10 M2
232 232 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001343
233 233 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001344 2700 KG
234 234 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001345
235 235 ii) Ordinary rock BI01010001010000000000000515BI0100001346 65 M3
236 236 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. BI01010001010000000000000515BI0100001347
237 237 i) Local Fine Sand within grading zone IV BI01010001010000000000000515BI0100001348 15 M3
238 238 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001349
239 239 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001350 15 M3
240 240 Providing & Laying Reinforced cement concrete work in walls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement : BI01010001010000000000000515BI0100001351
241 241 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001352 12 M3
242 242 Centering and shuttering including strutting, propping etc. and removal of form for : BI01010001010000000000000515BI0100001353
243 243 i) Foundations,footings,bases of columns, etc. for mass concrete BI01010001010000000000000515BI0100001354 99 M2
244 244 iii) Suspended floors,roofs,landings,balconies, access platform and Shelves (Cast in situ) BI01010001010000000000000515BI0100001355 87 M2
245 245 iv) Lintels, beams plinth beams,girders bressumers and cantilevers BI01010001010000000000000515BI0100001356 21 M2
246 246 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001357
247 247 iv) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand) in superstructure in all shapes & sizes in superstructure ABOVE PLINTH & UP TO FLOOR V LEVEL BI01010001010000000000000515BI0100001358 9 M3
248 248 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001359 4 M3
249 249 viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001360 45 M2
250 250 Providing and laying cement plaster on surfaces with fine sand including curing etc. BI01010001010000000000000515BI0100001361
251 251 i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) BI01010001010000000000000515BI0100001362 250 M2
252 252 Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete BI01010001010000000000000515BI0100001363 250 M2
253 253 Supplying and laying bituminous carpet of 75mm thick for sand pad in two layers using Bitumen of grade VG-10, @100kg/Cum of sand grit of fineness modulus 3.5max. Including making slope in the sand pad including rolling the surface with Hand roller. Item includes laying of 1000 micron (1mm) black LDPE liner as per IS 2508 under the desired layer of sand BI01010001010000000000000515BI0100001364 40 M2
254 254 Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement BI01010001010000000000000515BI0100001365 20 M2
255 255 40mm Thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand:4 stone aggregate of 20mm nominal size) finished with a floating cement coat of neat including cement slurry, but excluding the cost of nosing of steps etc. complete. BI01010001010000000000000515BI0100001366 10 M2
256 256 Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm BI01010001010000000000000515BI0100001367 150 M2
257 257 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade with 2 or more coats BI01010001010000000000000515BI0100001368 100 M2
258 258 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. BI01010001010000000000000515BI0100001369 30 M2
259 259 Providing and fixing 100x85x5.5 mm (heavy type) bright finished brass butt hinges with necessary screws etc. complete : BI01010001010000000000000515BI0100001370 9 EA
260 260 Providing and fixing 150 mm bright finished chrome plated brass hanging type floor door stopper with rubber cushion necessary brass screws, etc. complete. to suit shutter thickness complete BI01010001010000000000000515BI0100001371 3 EA
261 261 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. BI01010001010000000000000515BI0100001372 3 EA
262 262 Providing & fixing chromium plated brass 100mm mortice latch & lock with 6 levers & a pair of lever handles with necessary screws etc complete (best make of approved quality). BI01010001010000000000000515BI0100001373 3 EA
263 263 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length,jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 Part-I & M.S. top cover of required thickness for rolling shutters:- 80x1.25mm MS laths with1.25 mm thick top cover BI01010001010000000000000515BI0100001374 12 M2
264 264 Providing and fixing ball bearing for rolling shutters. BI01010001010000000000000515BI0100001375 6 EA
265 265 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixing all complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately) BI01010001010000000000000515BI0100001376
266 266 iii) For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) BI01010001010000000000000515BI0100001377 100 KG
267 267 i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections BI01010001010000000000000515BI0100001378 60 KG
268 268 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): BI01010001010000000000000515BI0100001379
269 269 i) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) BI01010001010000000000000515BI0100001380 24 M2
270 270 iii) With float glass panes of 8.0 mm thickness (weight not less than 20kg/sqm) BI01010001010000000000000515BI0100001381 5 M2
271 271 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). BI01010001010000000000000515BI0100001382 5 M2
272 272 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. BI01010001010000000000000515BI0100001383
273 273 i) With stainless steel cover plate BI01010001010000000000000515BI0100001384 1 EA
274 274 Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer-in- charge BI01010001010000000000000515BI0100001385
275 275 i) Powder coated minimum thickness 50 micron aluminium BI01010001010000000000000515BI0100001386 3 EA
276 276 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. BI01010001010000000000000515BI0100001387
277 277 ii) 110 mm diameter BI01010001010000000000000515BI0100001388 30 M
278 278 Providing & laying vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified BI01010001010000000000000515BI0100001389
279 279 i) Flooring with size of Tiles 60x60Cm in cement mortar 1:4 BI01010001010000000000000515BI0100001390 14 M2
280 280 25mm Thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) BI01010001010000000000000515BI0100001391 9 M2
281 281 Providing & fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 25 of approved design/pattern, with approved standard section & fixed to the existing window frame with C.P.brass /stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment) BI01010001010000000000000515BI0100001392 10 KG
282 282 Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade. BI01010001010000000000000515BI0100001393 18 M2
283 283 Providing & laying Ceramic Glazed floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) jointing with grey cement slurry@ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc. complete. BI01010001010000000000000515BI0100001394 7 M2
284 284 SALES BUILDING ELECTRIFICATION BI01010001010000000000000515BI0100001395
285 285 Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make BI01010001010000000000000515BI0100001396
286 286 iv) 2 x 6 sq mm + 1 x 6 sq mm earth wire BI01010001010000000000000515BI0100001397 20 M
287 287 ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire BI01010001010000000000000515BI0100001398 30 M
288 288 iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire BI01010001010000000000000515BI0100001399 20 M
289 289 i) 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire BI01010001010000000000000515BI0100001400 40 M
290 290 PROVIDING INTERNAL WIRING BI01010001010000000000000515BI0100001401
291 291 ii) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. BI01010001010000000000000515BI0100001402 30 EA
292 292 SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge. BI01010001010000000000000515BI0100001403
293 293 iv) 6 module frame BI01010001010000000000000515BI0100001404 4 EA
294 294 v) 8 module frame BI01010001010000000000000515BI0100001405 4 EA
295 295 vii) 6A Modular Switch BI01010001010000000000000515BI0100001406 25 EA
296 296 ix) 6A, 3 Pin Modular Socket BI01010001010000000000000515BI0100001407 3 EA
297 297 x) 15 A 6 Pin Modular socket BI01010001010000000000000515BI0100001408 2 EA
298 298 PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032. BI01010001010000000000000515BI0100001409
299 299 Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coil O/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KA for supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement of IOCL. BI01010001010000000000000515BI0100001410 1 EA
300 300 SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved including flush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer's specification and direction of Engineer In-charge. BI01010001010000000000000515BI0100001411
301 301 xii) Fan Regulator of stepped modular type BI01010001010000000000000515BI0100001412 3 EA
302 302 CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type: BI01010001010000000000000515BI0100001413
303 303 iii) 1200 mm sweep BI01010001010000000000000515BI0100001414 3 EA
304 304 Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001415 15 EA
305 305 Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watts with fittings and accessories, having IP20 protection class with CRCA/PC/Aluminium Extrusion housing & with UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer in charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall range from 5700 Kelvin (5665 K +/- 355 K) to 6500 Kelvin, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 80 for indoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 95 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 2kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001416 10 EA
306 306 SALES BUILDING TOILET BLOCK (NIL ITC) BI01010001010000000000000515BI0100001417
307 307 Providing and fixing 100x85x5.5 mm (heavy type) bright finished brass butt hinges with necessary screws etc. complete : BI01010001010000000000000515BI0100001418 9 EA
308 308 Providing and fixing factory made 30mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75mm x 30mm having wall thickness 5mm. The styles, top & bottom rails shall have one side wall thickness of 15mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with MS tubes of size 33mm x 17mm x 1mm painted with primer, all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and rails with a cavity to receive single piece extruded 5mm PVC sheet as panel. The styles and rails shall be mitred cut and joint with help of PVC solvent cement and self tapping screws. Single piece extruded solid PVC lock rail of size 100mm x 30mm with wall thickness 5mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8mm complete as per manufacturer's specifications and direction of Engineer-in-charge BI01010001010000000000000515BI0100001419
309 309 i) Non Decorative finish BI01010001010000000000000515BI0100001420 7 M2
310 310 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogeneous fine cellular structure having smooth outer integral skin having 62mm width and 32mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38mm x 4mm & PVC solvent cement, including fixing the frame to wall with suitable dia and length anchor fastener as per manufacturer's specification and direction of Engineer-in-charge. BI01010001010000000000000515BI0100001421 16 M
311 311 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. BI01010001010000000000000515BI0100001422
312 312 iv) Granite of any colour and shade having Area of slab over 0.50 sqm BI01010001010000000000000515BI0100001423 2.5 M2
313 313 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and SW drain pipe 100 mm diameter, 1.8 m long complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 BI01010001010000000000000515BI0100001424 1 EA
314 314 Providing and fixing water closet squatting pan (Indian type W.C.pan) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C.flushing cistern including flush pipe with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required -White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. BI01010001010000000000000515BI0100001425 1 EA
315 315 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white PVC flushing cistern including flush pipe with manually controlled device (handle lever),conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required: BI01010001010000000000000515BI0100001426
316 316 i) W.C. pan with ISI marked white solid plastic seat and lid BI01010001010000000000000515BI0100001427 1 EA
317 317 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : BI01010001010000000000000515BI0100001428
318 318 i) One urinal basin with 5 litre white P.V.C. automatic flushing cistern BI01010001010000000000000515BI0100001429 1 EA
319 319 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : BI01010001010000000000000515BI0100001430
320 320 i) 100 mm diameter BI01010001010000000000000515BI0100001431 2 EA
321 321 Providing and fixing toilet paper holder : BI01010001010000000000000515BI0100001432
322 322 i) C.P. brass BI01010001010000000000000515BI0100001433 2 EA
323 323 Providing & fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : BI01010001010000000000000515BI0100001434
324 324 ii) 100mm inlet & 75mm outlet SCI S&S as per IS - 3989. BI01010001010000000000000515BI0100001435 6 EA
325 325 Providing and fixing B class G.I. Pipes complete with G.I. fittings and clamps i/c making good the walls etc. concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall for WATER and AIR BI01010001010000000000000515BI0100001436
326 326 ii) 20 mm dia nominal bore BI01010001010000000000000515BI0100001437 30 M
327 327 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. BI01010001010000000000000515BI0100001438
328 328 i) 15 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001439 40 M
329 329 ii) 20 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001440 40 M
330 330 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : BI01010001010000000000000515BI0100001441
331 331 i) 15 mm nominal bore BI01010001010000000000000515BI0100001442 2 EA
332 332 ii) 20 mm nominal bore BI01010001010000000000000515BI0100001443 1 EA
333 333 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : BI01010001010000000000000515BI0100001444
334 334 ii) White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap BI01010001010000000000000515BI0100001445 2 EA
335 335 Providing and fixing brass bib cock of approved quality : BI01010001010000000000000515BI0100001446
336 336 i) 15 mm nominal bore BI01010001010000000000000515BI0100001447 8 EA
337 337 Providing and fixing brass stop cock of approved quality : BI01010001010000000000000515BI0100001448
338 338 i) 15 mm nominal bore BI01010001010000000000000515BI0100001449 8 EA
339 339 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : BI01010001010000000000000515BI0100001450
340 340 i) 25 mm nominal bore BI01010001010000000000000515BI0100001451 1 EA
341 341 Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank BI01010001010000000000000515BI0100001452 500 L
342 342 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : BI01010001010000000000000515BI0100001453
343 343 ii) 150 mm diameter BI01010001010000000000000515BI0100001454 5 M
344 344 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: BI01010001010000000000000515BI0100001455
345 345 ii) Inside dimensions 500x700 mm and 45 cm deep for pipeline with one or two inlets with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 BI01010001010000000000000515BI0100001456 1 EA
346 346 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: BI01010001010000000000000515BI0100001457
347 347 i) 100 mm diameter S.W. pipe BI01010001010000000000000515BI0100001458 2 M
348 348 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I.cover with frame of 300 x300 mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : BI01010001010000000000000515BI0100001459
349 349 i) 100x100 mm size P type with common burnt clay bricks of class Designation 7.5 BI01010001010000000000000515BI0100001460 1 EA
350 350 EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does not include making suitable cut out in the wall for fixing the fan). BI01010001010000000000000515BI0100001461
351 351 ii) 9" dia light duty, make Khaitan or equivalent BI01010001010000000000000515BI0100001462 4 EA
352 352 Providing Neat cement punning BI01010001010000000000000515BI0100001463 25 M2
353 353 Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001464 10 EA
354 354 Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watts with fittings and accessories, having IP20 protection class with CRCA/PC/Aluminium Extrusion housing & with UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer in charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall range from 5700 Kelvin (5665 K +/- 355 K) to 6500 Kelvin, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 80 for indoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 95 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 2kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. BI01010001010000000000000515BI0100001465 5 EA
355 355 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001466
356 356 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001467 3 M3
357 357 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001468
358 358 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001469 2 M3
359 359 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks BI01010001010000000000000515BI0100001470 8 M2
360 360 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil BI01010001010000000000000515BI0100001471 10 M2
361 361 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001472
362 362 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001473 250 KG
363 363 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001474
364 364 ii) Ordinary rock BI01010001010000000000000515BI0100001475 15 M3
365 365 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. BI01010001010000000000000515BI0100001476
366 366 i) Local Fine Sand within grading zone IV BI01010001010000000000000515BI0100001477 3.5 M3
367 367 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001478
368 368 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001479 5 M3
369 369 viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001480 15 M2
370 370 Providing and laying cement plaster on surfaces with Coarse sand including curing etc. BI01010001010000000000000515BI0100001481
371 371 ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand) BI01010001010000000000000515BI0100001482 25 M2
372 372 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. BI01010001010000000000000515BI0100001483 10 M2
373 373 SIDE DRAIN BI01010001010000000000000515BI0100001484
374 374 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001485
375 375 ii) Ordinary rock BI01010001010000000000000515BI0100001486 50 M3
376 376 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001487
377 377 vii) 1:3:6(1 Cement : 3 Fine Sand : 6 Graded stone aggregate of 40mm) BI01010001010000000000000515BI0100001488 4 M3
378 378 Centering and shuttering including strutting, propping etc. and removal of form work for: BI01010001010000000000000515BI0100001489
379 379 i) Foundations,footings,bases of column BI01010001010000000000000515BI0100001490 45 M2
380 380 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001491
381 381 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001492 23 M3
382 382 Providing and laying cement plaster on surfaces with Coarse sand including curing etc. BI01010001010000000000000515BI0100001493
383 383 ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand) BI01010001010000000000000515BI0100001494 150 M2
384 384 Providing Neat cement punning BI01010001010000000000000515BI0100001495 150 M2
385 385 GRATING CULVERT ON BOTH APPROACHES & OPEN DRAIN BI01010001010000000000000515BI0100001496
386 386 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 BI01010001010000000000000515BI0100001497
387 387 ii) Ordinary rock BI01010001010000000000000515BI0100001498 30 M3
388 388 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: BI01010001010000000000000515BI0100001499
389 389 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) BI01010001010000000000000515BI0100001500 2 M3
390 390 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level BI01010001010000000000000515BI0100001501
391 391 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm BI01010001010000000000000515BI0100001502 9 M3
392 392 Centering and shuttering including strutting, propping etc. and removal of form work for: BI01010001010000000000000515BI0100001503
393 393 i) Foundations,footings,bases of column BI01010001010000000000000515BI0100001504 95 M2
394 394 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels BI01010001010000000000000515BI0100001505
395 395 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 BI01010001010000000000000515BI0100001506 750 KG
396 396 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: BI01010001010000000000000515BI0100001507 1125 KG
397 397 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks BI01010001010000000000000515BI0100001508 20 M2
398 398 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth BI01010001010000000000000515BI0100001509
399 399 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH BI01010001010000000000000515BI0100001510 3 M3
400 400 Providing and laying cement plaster on surfaces with Coarse sand including curing etc. BI01010001010000000000000515BI0100001511
401 401 ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand) BI01010001010000000000000515BI0100001512 65 M2
402 402 Providing Neat cement punning BI01010001010000000000000515BI0100001513 65 M2
403 403 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty BI01010001010000000000000515BI0100001514
404 404 v) 600 mm dia. R.C.C. pipe BI01010001010000000000000515BI0100001515 8 M
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2021 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail