Military Engineer Services-MES has published Repair/Maintenance And Improvement Of Lt Cable/Lt Feeder Box/Lt Panel , Bus Bar Panels , Lt Switch Gear/Mccb/Lt Metering Panels/Amf Panel , Changeover Switch And Other Connected Works At West Of Mg Road Area At Age E/M Ext ( Elect ) Under Ge E/M Luck. Submission Date for this Tender is 17-12-2020. Switch Gear Tenders in Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 10-Dec-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 17-12-2020 |
Name of Work : REPAIR/MAINT AND IMPROVEMENT OF LT CABLE/LT FEEDER BOX/LT PANEL, BUS BAR PANELS, LT SWITCH GEAR/MCCB/LT METERING PANELS/AMF PANEL, CHANGEOVER SWITCH AND OTHER CONNECTED WORKS AT WEST OF MG ROAD AREA AT AGE E/M EXT (ELECT) UNDER GE E/M LUCKNOW. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Supply, installation, testing and commissioning out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and backopenable double door system lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which includes seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. The TPN busbar shall be insulated with colour coaded heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of theTPN busbar. The cubicle incomer MCCB as well as outgoing shall have aluminium TPN extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. The extension links shall not be less than 300mm long supported on suitable size "F" class insulator. All inter connections between the main busbar as well as outgoing feeder shaal be carried out with TPN aluminium busbar of rating not less than 1.5 times rated capacity of individual outgoing feeders & should be insulated with heat shrinkable PVC sleeves.comprising of the following:-\na) The TPN busbar duly plated copper busbar fitted in cascaded moulding.\nb) Incoming MCCB 250 Amps 36 kA, 415 volts, FP - 01 Nos\nc) Ongoing MCCB 100 Amps 25 kA, 415 volts, FP - 04 Nos d) Ongoing MCCB 63 Amps 25 kA, 415 volts, FP - 01 Nos e) Change over switch 200 Amp on load type, 415 volts, FP - 01 Nos\nf) Provn of blank compartment for future uses, 415 volts, FP - 01 Nos\ng) Voltage/Ampere/Frequency meter multi functional meter - 01 No\nh) LED indicator lamp RYB - 01 Set of three | BI01010001010000000000000515BI0100001114 | 1 | Each |
2 | 2 | All as per item No 01 above but with following\na) The TPN busbar duly plated copper busbar fitted in cascaded moulding.\nb) Incoming MCCB 250 Amps 36 kA, 415 volts, FP - 01 Nos\nc) Ongoing MCCB 100 Amps 25 kA, 415 volts, FP - 01 Nos d) Ongoing MCCB 160 Amps 25 kA, 415 volts, FP - 03 Nos \ne) Provn of blank compartment for future uses, 415 volts, FP - 01 Nos\nf) Voltage/Ampere/Frequency meter multi functional meter - 01 No\ng) LED indicator lamp RYB - 01 Set of three | 1 | Each | |
3 | 3 | All as per item No 01 above but with following\na) The TPN busbar duly plated copper busbar fitted in cascaded moulding.\nb) Incoming MCCB 250 Amps 36 kA, 415 volts, FP - 01 Nos\nc) Ongoing MCCB 160 Amps 25 kA, 415 volts, FP - 02 Nos d) Ongoing MCCB 100 Amps 25 kA, 415 volts, FP - 02 Nos \ne) Provn of blank compartment for future uses, 415 volts, FP - 01 Nos\nf) Voltage/Ampere/Frequency meter multi functional meter - 01 No\ng) LED indicator lamp RYB - 01 Set of three | 1 | Each | |
4 | 4 | Supply, installation, testing and commissioning out door type busbar panel board made out of 3.15 mm thick MS sheet and MS angle section 40x40x5 mm on PCC 1:2:4 type B-1 platform 40 cm above the ground level and 45 cm below the ground level, frame factory fabricated with front and back openable double door system lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which includes seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising and passivation followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93. \na) TPN, Aluminium bus bar 200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.\nb) Incoming MCCB 160 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No\nc) LED Indicator lamp RYB - 01 set of three.\n\n | 6 | Each \nJob | |
5 | 5 | LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 95 sqmm cross sectional area, 3.5 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers including jointing and testing complete and taking out unserviceable cable , complete all as specified and directed by Engineer-in- Charge. \nNote : Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.\n | 465 | RM | |
6 | 6 | All as per serial item No. 5 above but of size 120 Sqmm 3.5 core | 380 | RM | |
7 | 7 | All as per serial item No. 5 above but of size 185 Sqmm 3.5 core | 250 | RM | |
8 | 8 | All as per serial item No. 5 above but of size 240 Sqmm 3.5 core | 15 | RM | |
9 | 9 | All as per serial item No. 5 above but of size 300 Sqmm 3.5 core | 15 | RM | |
10 | 10 | Laying only old serviceable LT underground cable after removing of defects any type/size in trenches / road crossing /through pipes pat drains/ducts/floors/along poles/walls/ceilings in and including taking down old servicable cable for relaying after removing any fault , complete all as specified and directed by Engineer-in-Charge. \nNote :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.\n | 500 | RM | |
11 | 11 | Excavation in trenches not exc 1.5m wide and and not exc. 1.5m depth wide in soft/loose soil for laying electric cables/pipes etc including getting out excavated earth and trimming the sides and bottoms of trenches , complete all as specificed and directed by Engineer-in-Charge. | 270 | Cum | |
12 | 12 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested, complete all as specified and directed by Engineer-in-Charge. | 189 | Cum | |
13 | 13 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified and directed by Engineer-in-Charge. | 81 | Cum | |
14 | 14 | Plain cement concrete 1:3:6 type D-2 using 40 mm graded stone aggregates, as in coping of poles, complete all as specified and as directed by Engineer-in-Charge. | 5 | Cum | |
15 | 15 | Sand cushioning to cables with a layer of sand 8 cm deep before laying the cable and 15 cm depth (punned down to 10 cm depth after laying and stretching of cable), complete all as specificed and directed by Engineer-in-Charge.\nNote: Punned thickness (over all 18 cm) shall be measured & paid. | 81 | Cum | |
16 | 16 | Protection of cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks, complete all as specified and as directed by Engineer-in-Charge. | 8 | Each Job | |
17 | 17 | Boring / drilling (Horizontly ) manually under existing road Max 10 M in width suitable for passing GI tubing 40 to 100 mm bore, complete all as specified and as directed by Engineer-in-Charge. | 25 | RM | |
18 | 18 | End termination heat shrinkable joint including sleeves suitable for LT XPLE underground aluminium conductor cable 1000 Volt of grade 25 Sqmm to 50 Sqmm x 3.5/4 Core cross sectional area including testing after jointing as in replacment after disconnecting the cable from Panel / Pole, preparing the end for jointing including all earth work,complete all as specified and directed by Engineer-in-Charge.\n | 25 | Each | |
19 | 19 | All as per serial item No.18 above but of size 70 to 120 Sqmm | 20 | Each | |
20 | 20 | Straight through heat shirankable joint including sleeves suitable for LT XPLE underground aluminium conductor cable 1000 Volt of grade 25 Sqmm to 50 Sqmm x 3.5/4 Core cross sectional area including testing after jointing as in replacment after disconnecting the cable from Panel / Pole, preparing the for jointing including all earth work,complete all as specified and directed by Engineer-in-Charge.\n | 10 | Each | |
21 | 21 | All as per serial item No.20 above but of size 70 to 120 Sqmm | 5 | Each | |
22 | 22 | Mild steel galvanized tubes light grade ISI marked 40mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc in and including taking down old unservicable G I pipe ,compllete all as specified and as directed by Engineer-in-Charge. | 15 | RM | |
23 | 23 | All as per serial item No.22 above but of size 50 mm bore | 20 | RM | |
24 | 24 | All as per serial item No.22 above but of size 80 mm bore | 20 | RM | |
25 | 25 | Surface dressing/ cleaning of surrounding area of two pole/four pole structure / sub stn area 4mtr X4 mtr including removing of tree branches , complete all as specified and as directed by Engineer-in-Charge. | 50 | Each Job | |
26 | 26 | On load changeover manually operated 4 pole , 125 Amps four pole, fixed to wall/panels with suitable size clamps, nuts, bolts and washer, including necessary connection ,testing fixed as in relacment ,complete all as specified and as directed by Engineer in charge. | 5 | Each | |
27 | 27 | On load changeover manually operated 4 pole switch in sheet metal enclosure , 100 Amps four pole, fixed to wall/panels with suitable size clamps, nuts, bolts and washer, including necessary connection ,testing fixed as in relacment ,complete all as specified and as directed by Engineer in charge. | 5 | Each | |
28 | 28 | MCCB 63 Amp 3 pole 16 KA fixed type 415 volts 50 Hz with spreader and suitable size of cable lugs/thimble complete including all electrical connection and making good the damaged surface after disconnecting all existing electrical connection from panel including testing and taking out unserviceable MCCB and cable from LT panel Board , complete all as specified and directed by Engineer-in-Charge. \n | 10 | Each | |
29 | 29 | MCCB 100 Amp 3 pole 16 KA fixed type 415 volts 50 Hz with spreader and suitable size of cable lugs/thimble complete including all electrical connection and making good the damaged surface after disconnecting all existing electrical connection from panel including testing and taking out unserviceable MCCB and cable from LT panel Board , complete all as specified and directed by Engineer-in-Charge. \n | 10 | Each | |
30 | 30 | MCCB 160 Amp 4 pole 25 KA fixed type 415 volts 50 Hz with spreader and suitable size of cable lugs/thimble complete including all electrical connection and making good the damaged surface after disconnecting all existing electrical connection from panel including testing and taking out unserviceable MCCB and cable from LT panel Board , complete all as specified and directed by Engineer-in-Charge. \n | 10 | Each | |
31 | 31 | MCCB 200 Amp 4 pole 25 KA fixed type 415 volts 50 Hz with spreader and suitable size of cable lugs/thimble complete including all electrical connection and making good the damaged surface after disconnecting all existing electrical connection from panel including testing and taking out unserviceable MCCB and cable from LT panel Board , complete all as specified and directed by Engineer-in-Charge. \n | 10 | Each | |
32 | 32 | MCCB 250 Amp 4 pole 36 KA adjustable thermal and magnetic setting (80 to 100%) type 415 volts 50 Hz with spreader and suitable size of cable lugs/thimble complete including all electrical connection and making good the damaged surface after disconnecting all existing electrical connection from panel including testing and taking out unserviceable MCCB and cable from LT panel Board , complete all as specified and directed by Engineer-in-Charge. \n | 10 | Each | |
33 | 33 | MCCB 400 Amp 4 pole 36 KA adjustable thermal and magnetic setting(80 to 100%) type 415 volts 50 Hz with spreader and suitable size of cable lugs/thimble complete including all electrical connection and making good the damaged surface after disconnecting all existing electrical connection from panel including testing and taking out unserviceable MCCB and cable from LT panel Board , complete all as specified and directed by Engineer-in-Charge. \n | 2 | Each | |
34 | 34 | Painting on old painted surface of LT Panel/Feeder Piller Box by brushing after cleaning stain & grease spot with thinner and sand papar and painting the cleaned surface with synthetic enamel paint as existing colour to acheive good finish by applying two coat paint by spray painting machine carefully after disconnection of power supply and covering the meters, indicators, relays and switches to prevent fall of paint drop on them & including writing, numbering, letter etc with white paint on newly painted surfaces ,complete all as specified and as directed by Engineer-in-Charge | 40 | Each Job | |
35 | 35 | MCCB TP 63 Amps 10 KA, 415 Volts AC, 50 Hz, complete with in sheet metal enclosere of 1.6 mm thick MS sheet with powder coat painted including connecting with existing system and cabling network including making good disturbed surfaces including testing and taking out unserviceable MCCB , complete all as specified and directed by Engineer-in-Charge. \n | 10 | Each | |
36 | 36 | Submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated multistranded copper conductor cable 2x6 sqmm & 1x4 sqmm as earth wire with and including surface PVC casing caping of size not less than 20 mm complete all as specified and directed. | 200 | Each | |
37 | 37 | Maintenance of feeder pillar/LT panel indoor/outdoor type Panel by cutting corroded MS lid from LT panel, and weilding the same with 2 mm thick MS sheet in any desired shape including removing the carbonized/melted sparked thimbles, cleaning the carbonized bus bar making cable ends clean and replacement of following unserviceable parts with new nut bolts and washer , complete all as specified and directed by Engineer-in-Charge. \nNote : All spare parts and rewiring work will be measured and paid seperately under respective item of Sch 'A' as supply only and cost of fixing is deemed to be included in rates quoted against this item and nothing extra shall be admissible on this account .\n | 25 | Each Job | |
38 | 38 | Supply only multifunction meters in existing Panel of size 96X96 sqmm flush mounted case 3 line LED display, 1.0 Multifunction Panel Panel mounted meter 3 P2W/3P4W and -/ A or -/ A configurable, with RS 485 comunication port . | 10 | Each | |
39 | 39 | Supply only LED Indicator lamps (RYB) as per existing size | 10 | Set of Three | |
40 | 40 | Supply only Aluminium bus bars of 200 Amp . | 25 | KG | |
41 | 41 | Supply only PVC insulated unsheathed 1100 volt grade single core multistrand copper cable of size 4.00 sqmm for connection. | 50 | RM | |
42 | 42 | Supply only Powder coated CRCA sheet metal enclosure. | 25 | KG | |
43 | 43 | Earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 32x6mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 5 of SSR Part-I and testing ,including dismanteling of old unserviceable earthing , complete all as specified and as directed by Engineer-in-Charge. \nNote : \n(i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point.\n(ii) Earth pit shall be constructed minimum 1.00 metre away from earth.\n\n | 21 | Each | |
44 | 44 | Isolator 4P 100 Amp, 10 KA ,415 volts C curve fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge. | 50 | Each | |
45 | 45 | Isolator 4P 63 Amp, 10 KA ,415 volts C curve fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge. | 25 | Each | |
46 | 46 | Isolator TP 63 Amp, 10 KA ,415 volts C curve fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge. | 25 | Each | |
47 | 47 | MCB SPN, 32 Amp 10 kA, 240 volts AC 'C' curve fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge. | 100 | Each | |
48 | 48 | MCB SP, 05 to 32 Amp 10 kA, 240 volts AC 'C' curve fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge. | 200 | Each | |
49 | 49 | Taking down carefully the defective street light fittings 36/45/60/90 watt any type from the poles/walls and refixing the same on poles/walls after repair by replacement of unserviceable parts , complete all as specified and as directed by Engineer-in-Charge. \nNote :- Replacement of the parts shall be measured & paid separately as supply only under respective item. | 200 | Each Job | |
50 | 50 | Supply only LED driver ( 35 V/45V/65V DC)suitable for LED street lights of 45 Watt , complete all as specified and as directed by Engineer-in-Charge. | 50 | Each | |
51 | 51 | Supply only LED driver (90V/110V/220V DC) suitable for LED street lights of 90Watt , complete all as specified and as directed by Engineer-in-Charge. | 20 | Each | |
52 | 52 | LED street light fitting with mandatory driver set having pressure die cast aluminium body and lenses suitable for 45 watt confirming to IP 66 and IK 07 protection having company LOGO ingraved complete lumes high power LED with lenses Lumen efficacy of LED not less than 100 lumen per watt system,efficency power factor >0.95, THD<10% at Full load CRI> 70%, every life class 50000 hrs at the L70,poted driver set , Phase to phase protection at 415 Volts , over voltage protection,surge voltage protection and other seafty test as per IS 15885 Part-II /Sec 13 and BIS comply ) incl fitting suitable for pole mounting bracket 40 mm. all releven documents related to luminaries and driver needed to submit for approval fixed as in replacment of old unservicable light , complete all as specified and as directed by Engineer-in-Charge. | 352 | Each | |
53 | 53 | LED street light fitting with mandatory driver set having pressure die cast aluminium body and lenses suitable for 60 watt confirming to IP 66 and IK 07 protection having company LOGO ingraved complete lumes high power LED with lenses Lumen efficacy of LED not less than 100 lumen per watt system,efficency power factor >0.95, THD<10% at Full load CRI> 70%, every life class 50000 hrs at the L70,poted driver set , Phase to phase protection at 415 Volts , over voltage protection,surge voltage protection and other seafty test as per IS 15885 Part-II /Sec 13 and BIS comply ) incl fitting suitable for pole mounting bracket 40 mm. all releven documents related to luminaries and driver needed to submit for approval fixed as in replacment of old unservicable light , complete all as specified and as directed by Engineer-in-Charge. | 20 | Each | |
54 | 54 | LED flood light fitting with mandatory driver set having pressure die cast aluminium body (LM 6 alloy) and lenles suitable for 50 watt confirming to IP 66 and IK 07 protection having company LOGO ingraved complete in respect high power LED with lences>100LM/watt system,efficency power factor >0.95, THD<10% at Full load CRI> 70%, every life class 50000 hrs at the rate L70,poted driver setwith BIS No return on it all to releven documents related to luminaries and driver needed to submit for approval fixed as in replacment of old unservicable light , complete all as specified and as directed by Engineer-in-Charge. | 22 | Each | |
55 | 55 | LED flood light fitting with mandatory driver set having pressure die cast aluminium body (LM 6 alloy) and lenles suitable for 120 watt in green colour confirming to IP 66 and IK 08 protection having company LOGO ingraved complete in respect with system lumes high power LED with lences>100 LM/watt system,efficency power factor >0.95, THD<10% at Full load CRI> 70%, every life class 50000 hrs at the rate L70,poted driver set , Phase to phase protection , over voltage protection,surge voltage protection and other seafty test as per IS 15885 Part-II /Sec 13 and BIS comply ) all to releven documents related to luminaries and driver needed to submit for approval fixed as in replacment of old unservicable light , complete all as specified and as directed by Engineer-in-Charge. | 10 | Each | |
56 | 56 | LED lamp 10/12 Watt retrofit type for garden light fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge. | 100 | Each | |
57 | 57 | Batten Holder fixed as in replacment, complete all as specified and as directed by Engineer-in-Charge. | 100 | Each | |
58 | 58 | GI brackets made of 32/40 mm nominal bore GI pipe medium grade of required length not less than 1.5 M long, mounting brackets made out of Mild steel FI 40x6 mm of required shape ( two Nos) duly fitted with Mild steel nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide Zn chrome primer and fixed to pole / walls etc fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge. | 50 | Each | |
59 | 59 | MS Junction Box made of 1.6 mm thick MS sheet of size 200mmx200mmx150mm complete with front openable hinged cover and locking arrangements with 4 Nos aluminium bas bar 100 Amps, mounted on porcelin insulator including M&L for MCB SP 10-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including duly painted with powder coated paint fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge. | 50 | Each Job | |
60 | 60 | Flat twin core ,10 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable in and including taking out of old unservicable cable , complete all as specified and as directed by Engineer-in-Charge. | 1000 | RM | |
61 | 61 | All as per serial item No. 60 above but of size 4.0 sqmm twin core. | 1000 | RM | |
62 | 62 | All as per serial item No. 60 above but of size 6.0 sqmm twin core. | 1000 | RM | |
63 | 63 | Contactor TP 32 Amp 1NO+1NC,415 V fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge. | 5 | Each | |
64 | 64 | Digital Time switch in existing Panel ,Programmable every 1 min with backup of 6 yrs,28 memory location, current cap 16 Amp with 1 changeover (1CO) fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge. | 5 | Each | |
65 | 65 | Automatic street light switch using Infrared Sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of natural light. Required illuminance for switching ON is < 30 Lux and for switching OFF > 10 Lux level. The sensor (nature switch) alongwith suitable power contactors, Input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR graded SMC junction box conforming to IP-54 degree of ingress three phase 8 KW lightening load capacity fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge. | 10 | Each | |
66 | 66 | LED Light Fitting , Aluminium Sheet Spun Canopy,Thick Imported Acrylic Sheet Molded Body Finished With Stove -Enameled Paint Totoal Lenght 285 Mm & Bridth 305 Mm With B-22 Abs Holder incl lamp 9/12 Watt complete all as specified and as directed by Engineer-in-Charge. | 20 | Each | |
67 | 67 | PVC perplex cover diamond shape suitable for post top lantern fittings of 18” dia fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge. | 20 | Each | |
68 | 68 | Material and labour for servicing/repair of AMF panel from authorised rep or service engineer from the manufacturer of AMF Panel of capacity upto 250/350 KVA of DG set for smooth functioning of DG set incl renewal/repairs of AMF panel wiring, control timer, engine starting relay, contact point relay, AMF relay, HRC fuse of existing rating at various location under AGE E/M EXT(ELECT) complete all as specified and directed by Engineer-in-Charge. \nNote:- (i) The sapre parts shall be measured and paid seperately in relavent items of schedule and other minor repair as required for function of AMF panel and DG set to be included in the quated rate (ii) Contractor check the site before quoting the rate | 30 | Each Job | |
69 | 69 | Supply only electronic control timer type ET-100 of suitable capacity or existing make,model and capcity etc as required at site incl taking down ole one etc complete all as specified and directed by Engineer-in-Charge. | 3 | Each | |
70 | 70 | Supply Auto Mains Failure (AMF) relay as per existing model and make of AMF panels of DG sets of any capacity incl taking down old one etc complete all as specified and directed by Engineer-in-Charge. | 3 | Each | |
71 | 71 | Supply power contactor as per existing make,model and capacity suitable for upto 200 KVA to 320 KVA DG set ,AC 415 Volts, 50 Hz for AMF panel including testing and taking down old one complete all as specified and directed by Engineer-in-Charge. | 2 | Each | |
72 | 72 | Supply power contactor as per existing make,model and capacity suitable for upto 100 KVA to 125 KVA DG set ,AC 415 Volts, 50 Hz for AMF panel including testing and taking down old one complete all as specified and directed by Engineer-in-Charge. | 3 | Each | |
73 | 73 | Supply power contactor as per existing make,model and capacity suitable for upto 63 KVA to 83 KVA DG set ,AC 415 Volts, 50 Hz for AMF panel including testing and taking down old one complete all as specified and directed by Engineer-in-Charge. | 6 | Each | |
74 | 74 | Supply power contactor as per existing make,model and capacity suitable for upto 15 to 40 KVA DG set ,AC 415 Volts, 50 Hz for AMF panel including testing and taking down old one complete all as specified and directed by Engineer-in-Charge. | 5 | Each | |
75 | 75 | Supply only indicator lamp as per existing make,model & capacity etc complete all as specified and directed by Engineer-in-Charge. | 10 | Each | |
76 | 76 | Supply only selector switch as per existing make,model & capaicty etc complete all as specified and directed by Engineer-in-Charge. | 10 | Each | |
77 | 77 | Supply only Push button as per existing make,model & capaicty etc complete all as specified and directed by Engineer-in-Charge. | 10 | Each | |
78 | 78 | Supply only digital/anologe ammeter as per existing make,model & capcity etc complete all as specified and directed by Engineer-in-Charge. | 10 | Each | |
79 | 79 | Supply only digital/anologe voltmeter as per existing make,model & capcity etc complete all as specified and directed by Engineer-in-Charge. | 10 | Each | |
80 | 80 | Supply only VAF meter as per existing make,model & capcity etc complete all as specified and directed by Engineer-in-Charge. | 3 | Each | |
81 | 81 | Supply only battery charger as per existing make,model & capcity etc complete all as specified and directed by Engineer-in-Charge. | 3 | Each | |
82 | 82 | Supply only engine starter relay of suitable capacity as required at site complete all as specified and directed by Engineer-in-Charge. | 3 | Each | |
83 | 83 | Supply under voltage relay complete all as specified and directed by Engineer-in-Charge. | 3 | Each | |
84 | 84 | Supply only 8/11 pin relay complete all as specified and directed by Engineer-in-Charge. | 2 | Each | |
85 | 85 | Cotton waste/cotton cloth for maintenance of DG set complete all as specified and directed by Engineer-in-Charge. | 100 | Kg | |
86 | 86 | Supplying and fixing four pole 32 Amp `OFF LOAD' changeover in sheet metal enclosure with side operated handle suitable for 415 volts ,50 Hz AC supply including fixed to walls/ panels with suitable size clamps, nuts, bolts ,washers and connection & testing and taking down old one etc complete all as specified and directed by Engineer-in-Charge. | 3 | Each | |
87 | 87 | All as per Item No 86 above but 63 Amps | 2 | Each | |
88 | 88 | All as per Item No 86 above but 100 Amps | 2 | Each | |
89 | 89 | All as per Item No 86 above but 200 Amps | 2 | Each | |
90 | 90 | Supply & Fixing four pole 600 Amps "ON LOAD" type Change over switch front handle operated open execution as per existing make/model/capacity to be fixed on existing LT/AMF Panels, suitable for three phase, 415V, 50 Hz AC supply incl connection and testing and taking down old one etc complete all as specified and directed by Engineer-in-Charge. | 2 | Each | |
91 | 91 | All as per Item No 90 above but 400 Amps | 1 | Each | |
92 | 92 | All as per Item No 90 above but 315 Amps | 1 | Each | |
93 | 93 | All as per Item No 90 above but 250 Amps | 2 | Each | |
94 | 94 | S & F MCCB 100/125 Amp 3 pole breaking capcity 16 KA with thermal & magnetic release as per existing make/model/type of the following capacity & rupturing capacity suitable for 415 volts 50 HZ with spreader terminals to be fixed on existing panel incl taking down old one etc complete all as specified and directed by Engineer-in-Charge. | 3 | Each | |
95 | 95 | All as per Item No 94 above but 100/125 Amp 3 pole breaking capacity 25 KA | 1 | Each | |
96 | 96 | All as per Item No 94 above but 160 Amp 3 pole breaking capacity 25 KA | 2 | Each | |
97 | 97 | All as per Item No 94 above but 200 Amp 3 pole breaking capacity 35 KA | 3 | Each | |
98 | 98 | All as per Item No 94 above but 250 Amp 3 pole breaking capacity 35 KA | 2 | Each | |
99 | 99 | All as per Item No 94 above but 400 Amp 3 pole breaking capacity 50 KA | 3 | Each | |
100 | 100 | S & F MCCB 100/125 Amp 4 pole breaking capcity 16 KA with thermal & magnetic release as per existing make/model/type of the following capacity & rupturing capacity suitable for 415 volts 50 HZ with spreader terminals to be fixed on existing panel etc complete all as specified and directed by Engineer-in-Charge. | 2 | Each | |
101 | 101 | All as per Item No 100 above but 100/125 Amp 4 pole breaking capacity 25 KA | 1 | Each | |
102 | 102 | All as per Item No 100 above but 160 Amp 4 pole breaking capa\city 25 KA | 2 | Each | |
103 | 103 | All as per Item No 100 above but 200 Amp 4 pole breaking capacity 35 KA | 1 | Each | |
104 | 104 | All as per Item No 100 above but 250 Amp 4 pole breaking capacity 35 KA | 2 | Each | |
105 | 105 | All as per Item No 100 above but 400 Amp 4 pole breaking capacity 50 KA | 1 | Each | |
106 | 106 | All as per Item No 100 above but 630 Amp 4 pole breaking capacity 50 KA | 2 | Each | |
107 | 107 | M&L for indoor/outdoor termination heat shrink type cable jointing kit of 1100 Volts grade with jointing material & accessories incl taking down old one, suitable for suitable XLPE insulated armoured aluminium conductor cable of 240 to 300 Sqmm 3.5 Core size complete all as specified and directed by Engineer-in-Charge. | 1 | Each | |
108 | 108 | All as per Item No 107 above but 120 to 185 Sqmm 3.5 Core | 1 | Each | |
109 | 109 | All as per Item No 107 above but 50 to 95 Sqmm 3.5 Core | 2 | Each | |
110 | 110 | All as per Item No 107 above but 10 to 35 Sqmm 3.5 or 4 Core. | 2 | Each | |
111 | 111 | M&L for straight through heat shrink type cable jointing kit of 1100 Volts grade cable for with jointing material and accessories incl taking down old one, suitable XLPE armoured aluminium conductor cable of 240to 300s qmm 3.5 Core size complete all as specified and directed by Engineer-in-Charge. | 2 | Each | |
112 | 112 | All as per Item No 111 above but 120 to 185 Sqmm 3.5 Core | 2 | Each | |
113 | 113 | All as per Item No 111 above but 50 to 95 Sqmm 3.5 Core | 3 | Each | |
114 | 114 | All as per Item No 111 above but 10 to 35 Sqmm 3.5 or 4 Core. | 2 | Each | |
115 | 115 | S&F decorative box type fitting with blue colour end cap for LED tube 18 watt luminaire for 230 volt AC incl LED tube 16 watt incl taking down old one complete all as specified and directed by Engineer-in-Charge. | 5 | Each | |
116 | 116 | M&L for cleaning of DG set sub station area incl cutting the tree branches any size & shape and taking out the roots of vegetable around 10 m radius of t the sub station etc complete all as specified and directed by Engineer-in-Charge. | 20 | Each \nJob | |
117 | 117 | M&L for taking out the unserviceable canopy gate, LT panel cover any type,size & capacity and refixing the same after repair incl hinges,welding etc incl painting as per existing complete all as specified and directed by Engineer-in-Charge. | 10 | Each \nJob |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail