Indian Oil Bihar State Offiice Enginneerig Invite Tender For Development Of New A Site Retail Outlet Development Of New A Site Retail Outlet On Nh57 AtSarochia , Thana-Kasba , Dist . Purnea Under Begusarai Divisional Office OfBihar State Office, NH 57 at Sarochia Thana Kasba Distt Purnea Bihar-Bihar

Indian Oil Corporation Limited-IOCL has published Indian Oil Bihar State Offiice Enginneerig Invite Tender For Development Of New A Site Retail Outlet Development Of New A Site Retail Outlet On Nh57 AtSarochia , Thana-Kasba , Dist . Purnea Under Begusarai Divisional Office OfBihar State Office. Submission Date for this Tender is 05-12-2020. Civil Work Tenders in NH 57 at Sarochia Thana Kasba Distt Purnea Bihar Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

26094767
Indian Oil Bihar State Offiice Enginneerig Invite Tender For Development Of New A Site Retail Outlet Development Of New A Site Retail Outlet On Nh57 AtSarochia , Thana-Kasba , Dist . Purnea Under Begusarai Divisional Office OfBihar State Office
Open Tender
Indian
Bihar
NH 57 at Sarochia Thana Kasba Distt Purnea Bihar
05-12-2020

Tender Details

Indian Oil Bihar State Offiice Enginneerig Invite Tender For Development Of New A Site Retail Outlet Development Of New A Site Retail Outlet On Nh57 AtSarochia , Thana-Kasba , Dist . Purnea Under Begusarai Divisional Office OfBihar State Office

Key Value

Document Fees
Refer document
EMD
INR 167000.0 /-
Tender Value
INR 1.66 Crore /-

BOQ Items

Name of Work: Development of New A Site Retail Outlet on NH-57 at Sarochia, Thana-Kasba, Dist.-Purnea under Begusarai Divisional Office of Bihar State Office
Sl. No. Item Description Item Code / Make Qty Units
1 1 NRO at Mauza Sarochia on NH-57 : Civil Works b1
2 2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600 b2
3 3 i) All kinds of Soil b3 920 M3
4 4 Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil b4 41 M3
5 5 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m b5 55 M3
6 6 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. b6
7 7 i) Local Fine Sand within grading zone IV b7 67 M3
8 8 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: b8
9 9 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) b9 10 M3
10 10 v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) b10 7 M3
11 11 viii) 1:4:8(1 Cement :4 Coarse Sand :8 Graded stone aggregate of 40mm) b11 150 M3
12 12 Centering and shuttering including strutting, propping etc. and removal of form work for: b12
13 13 i) Foundations,footings,bases of column b13 122 M2
14 14 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level b14
15 15 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm b15 35 M3
16 16 Providing & Laying Reinforced cement concrete work in walls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement : b16
17 17 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm b17 3 M3
18 18 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20 mm nominal size) b18 14 M3
19 19 Providing and laying RCC work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). b19 1 M3
20 20 Centering and shuttering including strutting, propping etc. and removal of form for : b20
21 21 i) Foundations,footings,bases of columns, etc. for mass concrete b21 117 M2
22 22 v) Columns, Pillars, Piers, Abutments, Posts and Struts. b22 45 M2
23 23 vii) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards b23 25 M2
24 24 viii) Suspended floors, roofs,landings balconies and access platform with water proof ply 12mm thick b24 82 M2
25 25 ix) Lintels, beams, plinth beams, girders, bressumers cantilevers and with water proof ply 12mm thick b25 63 M2
26 26 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels b26
27 27 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 b27 4100 KG
28 28 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth b28
29 29 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH b29 86 M3
30 30 iv) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand) in superstructure in all shapes & sizes in superstructure ABOVE PLINTH & UP TO FLOOR V LEVEL b30 12 M3
31 31 x) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement:4 coarse sand in superstructure ABOVE PLINTH level & UP TO FLOOR V LEVEL b31 40 M2
32 32 Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks b32 42 M2
33 33 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. b33
34 34 iv) Granite of any colour and shade having Area of slab over 0.50 sqm b34 7 M2
35 35 Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete. b35 12 M2
36 36 Providing & fixing MS grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc.including priming coat with approved steel primer (fixed to steel windows by welding) all complete. b36 100 KG
37 37 Providing & fixing chrome plated brass100mm mortise latch with one dead bolt with 6 levers & a pair of lever handles with necessary screws etc. complete (best make of approved quality). b37 1 EA
38 38 Providing and fixing 150 mm bright finished chrome plated brass hanging type floor door stopper with rubber cushion necessary brass screws, etc. complete. to suit shutter thickness complete b38 1 EA
39 39 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. b39 1 EA
40 40 Providing & fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : b40
41 41 i) 250x10 mm b41 2 EA
42 42 ii) 200x10 mm b42 8 EA
43 43 Providing & fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : b43
44 44 i) 125 mm b44 10 EA
45 45 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: b45 11850 KG
46 46 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length,jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 Part-I & M.S. top cover of required thickness for rolling shutters:- 80x1.25mm MS laths with1.25 mm thick top cover b46 34 M2
47 47 Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S. bar instead of laths as per design approved by Engineer-in- charge.(area of grill to be measured). b47 8 M2
48 48 Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement b48 35 M2
49 49 Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade. b49 48 M2
50 50 Providing & laying Ceramic Glazed floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) jointing with grey cement slurry@ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc. complete. b50 10 M2
51 51 Providing & laying vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified b51
52 52 i) Flooring with size of Tiles 60x60Cm in cement mortar 1:4 b52 16 M2
53 53 iii) Skirting with size of Tiles 60x60Cm in Cement mortar 1:3 b53 10 M2
54 54 Providing and fixing  Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of Cold rolled steel confirming to IS:513-2008 of base metal thickness 0.50 mm, having Yield Stress of Min. 275 MPa. Steel surface shall have hot dip metallic coating of Al-Zinc alloy comprising 55% Alluminium, 43.5% Zinc and 1.5% Silicon as per the ASTM-A792M, with total mass of coating on both sides shall be 150 gms/sqm. The steel shall have organic coating with Silicon Modified Polyester (SMP) /Super Durable Polyester (SDP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns SMP /SDP paint over 5-7 microns epoxy primer) and back side 8-10 Microns SMP/SDP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.58 MM. Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m or as desired by Engineer-in-charge. b54
55 55 ii) Plain Sheet for Ridges (500 - 600mm). b55 13 M
56 56 iii) Plain sheet for Flashings/ Aprons (Upto 600 mm) b56 55 M
57 57 iv) Plain Sheet for Gutter (600 mm over all girth) b57 24 M
58 58 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. b58
59 59 ii) 110 mm diameter b59 13 M
60 60 iii) 160 mm diameter PVC Rain water pipe b60 28 M
61 61 Providing and fixing  150F/200F flush panel,(pre-coated steel) False Ceiling made of  Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of  thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure. b61 180 M2
62 62 Providing and laying cement plaster on surfaces with Coarse sand including curing etc. b62
63 63 ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand) b63 550 M2
64 64 Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc. b64
65 65 i) 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand) b65 30 M2
66 66 Providing Neat cement punning b66 33 M2
67 67 Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete b67 450 M2
68 68 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : b68 100 M2
69 69 Finishing walls with Acrylic Smooth exterior paint of required shade (2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm) b69 180 M2
70 70 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade with 2 or more coats b70 100 M2
71 71 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. b71 450 M2
72 72 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth within premises b72 2100 M2
73 73 Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plant at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired density, complete as per specification & direction of Engineer-in-charge. b73
74 74 iii) With material confirming to grade-III (size 26.5 mm to .075 mm) having CBR value -20, Thickness as desired b74 440 M3
75 75 Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to .075 mm) to wet mix macadam (WMM) specifications including premixing the material with water at OMC for all leads and lifts, laying in uniform layers with mechanical paver finisher in sub-base/base course on well prepared surface and compacting with vibratory roller of 8 to 10 ton capacity to achieve the desired density, complete as per specifications & directions of Engineer-in- charge b75 460 M3
76 76 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : b76
77 77 ii) White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap b77 4 EA
78 78 Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan)with seat lid with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40mm flush bend 20mm over flow pipe with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend. b78 4 EA
79 79 Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. b79 4 EA
80 80 Providing & fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete b80
81 81 iii) With Flexible pipe of 32 mm dia b81 4 EA
82 82 Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. b82 4 EA
83 83 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall b83
84 84 i) 15 mm nominal outer dia Pipes b84 20 M
85 85 iii) 25 mm nominal outer dia Pipes b85 25 M
86 86 v) 40 mm nominal outer dia Pipes b86 60 M
87 87 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. b87
88 88 ii) 20 mm nominal outer dia Pipes b88 20 M
89 89 iii) 25 mm nominal outer dia Pipes b89 10 M
90 90 Providing and fixing B class G.I. pipes complete with G.I. fittings & clamps, i/c cutting & making good the walls etc. Internal work Exposed on wall. b90
91 91 i) 15 mm nominal outer dia Pipes b91 20 M
92 92 Providing and fixing brass bib cock of approved quality : b92
93 93 i) 15 mm nominal bore b93 4 EA
94 94 Providing and fixing brass stop cock of approved quality : b94
95 95 i) 15 mm nominal bore b95 10 EA
96 96 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : b96
97 97 i) 25 mm nominal bore b97 3 EA
98 98 iii) 40 mm nominal bore b98 1 EA
99 99 Constructing masonry Chamber 30x30x50 cm, inside, in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with CI surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement:2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design: With common burnt clay F.P.S (non modular) bricks of class designation 7.5 b99 8 EA
100 100 Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank b100 1000 L
101 101 Providing and fixing PTMT grating of approved quality and colour. b101
102 102 ii) Circular type 125 mm nominal dia with 25 mm waste hole b102 8 EA
103 103 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty b103
104 104 ii) 150 mm dia. R.C.C. pipe b104 80 M
105 105 iv) 300 mm dia. R.C.C. pipe b105 40 M
106 106 Providing and laying non-pressure NP3 class (Medium class) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc.complete b106
107 107 iii) 1200 mm dia. R.C.C. pipe (Laying by manual/ mechanical means) b107 50 M
108 108 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and SW drain pipe 100 mm diameter, 1.8 m long complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 b108 1 EA
109 109 Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M 25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with, bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler, mounted, Telescopic Boom Hydraulic pilling Rig all complete. including removal of excavated earth with all lifts & leads (Length of pile for payment shall be measured upto bottom of pile cap). Truck mounted rotary/TMR/Tubewell boring machine shall not be used b109
110 110 i) 300 mm dia piles b110 78 M
111 111 Extra over item for Single under ream pile for providing additional bulb in under reamed piles, under specified dia meter (Only the quantity of extra bulbs are to be paid) b111
112 112 i) 300 mm dia piles b112 8 EA
113 113 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixing all complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately) b113
114 114 i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections b114 175 KG
115 115 iii) For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) b115 100 KG
116 116 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): b116
117 117 i) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) b117 1 M2
118 118 ii) With float glass panes of 5.0 mm thickness (weight not less than 12.5kg/sqm) b118 34 M2
119 119 iii) With float glass panes of 8.0 mm thickness (weight not less than 20kg/sqm) b119 3 M2
120 120 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. b120
121 121 i) With stainless steel cover plate b121 1 EA
122 122 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc. complete as per direction of Engineer-in-Charge. b122
123 123 i) Powder coated minimum thickness 50 micron aluminium tubular handle bar b123 2 EA
124 124 Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge : b124
125 125 v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate b125 40 EA
126 126 Boring/drilling bore well of required dia for casing/ strainer pipe by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, b126
127 127 iv) 300mm dia in all types of soil up to 90m depth below ground b127 70 M
128 128 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticised PVC medium well casing (CM) pipe of required dia,conforming to IS:12818, including required hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. b128
129 129 i) 100 mm nominal size dia b129 50 M
130 130 ii) 150 mm nominal size dia b130 20 M
131 131 Supply and packing Gravel in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. b131 1 M3
132 132 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: b132
133 133 i) 100 mm dia b133 1 EA
134 134 Providing and fixing M.S. clamp of required dia to the top of casing / housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete b134
135 135 i) 100 mm dia clamp b135 1 EA
136 136 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). b136
137 137 i) 100 mm dia b137 1 EA
138 138 Providing & laying factory made reflective type Lacquered finish Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih vibratory compaction & of approved size and design / shape, shade and manufacturers and as per IOCL's specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658, maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881, maximum dimensional deviations of +/- 2mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete. (Payment for provision of edge restraints shall be made separately) b138
139 139 ii) M40 grade 80 mm thick reflective type Lacquered finish b139 2000 M2
140 140 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items b140
141 141 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS b141 260 M
142 142 v) 4 Core x 2.5 sq. mm Copper Cable FRLS b142 50 M
143 143 vi) 3 Core x 1.5 sq.mm Copper Cable FRLS b143 20 M
144 144 xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS b144 65 M
145 145 SUPPLY AND LAYING OF FLAT CABLES b145
146 146 i) 3core, 2.5 sq.mm copper Flat Cable for submersible pump b146 80 M
147 147 Supplying, fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling and/or fix to steel/RCC columns, beams or any other structure members with MS suspenders, angles, channels, etc complete as per the direction of IndianOil b147
148 148 ii) 200mm x 50mm x 2mm b148 10 M
149 149 Supply & Fixing of Weatherproof (IP-65) Thermoplastic Cable Junction Box with terminal block fitted inside the box suitable for following cable sizes. b149
150 150 i) for 2.5 sq.mm. cable entry size with 9 terminals b150 3 EA
151 151 Providing, fixing, testing and commissioning of FLP junction box of approved make for cable connection/ jointing. b151
152 152 i) For cables 2.5 to 4 sqmm XLPE / AYFY b152 1 EA
153 153 Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job) b153 2 EA
154 154 i) Electrical insulating mats made of PVC Elastomer 3mm Thick & 1 mtr wide near swichboards, etc as per direction of Engineer In charge. Mat should conform to IS 15652 Class A - suitable for safe working voltage of upto 33 kV. Test certificate to be provided with supply. Mat's top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. Mat's top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. b154 1 M2
155 155 ii) 6 mm thick chequered plate on cable trench inside swtich room, DG room, earthing pit including cutting, painting, lifting hooks, etc b155 3 M2
156 156 iii) Supply and fixing of shock treatment chart in English, Hindi & local language framed in glass framework. b156 1 EA
157 157 iv) 11 KV grade hand gloves, ISI mark b157 1 EA
158 158 ii) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. b158 40 EA
159 159 Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make b159
160 160 ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire b160 60 M
161 161 xii) Fan Regulator of stepped modular type b161 4 EA
162 162 Supplying and fixing of following MCBs with necessery inter connections on existing DB, Panel board etc. b162
163 163 ii) Upto 32A DP MCB b163 9 EA
164 164 Supply and installation of MCB distribution board having Double door complete with tinned cu bus bar, neutral bus bar, earth bar, din bar, interconnection, earthing etc. without incoming isolator and MCBs b164
165 165 ii) 2+8 way SPN b165 1 EA
166 166 Supplying & fixing of approved make 4 pole change over switch in steel sheet enclosure with side handle operation onload type grouting in C.C. Complete as per direction of Engineer-In-Charge. b166
167 167 ii) 63 Amps., 4 Pole b167 1 EA
168 168 Supply and Installation of Flame Proof ESD Push Button b168 1 EA
169 169 Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. b169 10 EA
170 170 CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type: b170
171 171 iii) 1200 mm sweep b171 3 EA
172 172 EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does not include making suitable cut out in the wall for fixing the fan). b172
173 173 ii) 9" dia light duty, make Khaitan or equivalent b173 4 EA
174 174 SUBMERSIBLE PUMP Supply,erection,testing & Commissioning of foll.submersible water pump with starter panel board, non return valve, gate valve etc. complete. b174
175 175 ii) 33 LPM 100m head b175 1 EA
176 176 Providing & fixing BARE Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of bare metal thickness 0.55 mm as per ASTM A446 having yield stress of 275mpa, surface shall have hot dip metallic coating of Aluminium Zinc alloy comprising of 55% aluminium,43.5% zinc & 1.5% silicon, Sheet shall have protective guard film of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m or as desired by Engineer-in-charge. b176 180 M2
177 177 S/F of 09 Watt LED Bulb b177 15 EA
178 178 S/F OF ACP SHEET IN ALUM - DOORS b178 8 SQM
179 179 S/F TOWEL RAIL b179 4 EA
180 180 S/F SOAP TRAY b180 4 EA
181 181 HEALTH FAUCET & JET SPRAYS WITH 02 WAY B b181 4 EA
182 182 Supply and Fixing of under Canopy Recessed mounted Discrete LED (Light Emitting Diode) Light fixture of 100 watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour Temperature) shall be in the range of 5665K +/- 355K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. b182 8 EA
183 183 Supply and Fixing of under Canopy Recessed mounted Discrete LED (Light Emitting Diode) Light fixture of 80 watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour Temperature) shall be in the range of 5665K +/- 355K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. b183 12 EA
184 184 Supplying & Fixing of FRP Septic Tank of minimum capacity 1000 Litre b184 1 EA
185 185 NRO at Mauza Sarochaia on NH-57 : P & M Works b185
186 186 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600 b186
187 187 i) All kinds of Soil b187 12 M3
188 188 Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. b188
189 189 i) Local Fine Sand within grading zone IV b189 20 M3
190 190 Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: b190
191 191 iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) b191 4 M3
192 192 v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) b192 3 M3
193 193 Centering and shuttering including strutting, propping etc. and removal of form work for: b193
194 194 i) Foundations,footings,bases of column b194 13 M2
195 195 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level b195
196 196 ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm b196 7 M3
197 197 Centering and shuttering including strutting, propping etc. and removal of form for : b197
198 198 i) Foundations,footings,bases of columns, etc. for mass concrete b198 50 M2
199 199 Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels b199
200 200 ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 b200 500 KG
201 201 Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth b201
202 202 ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH b202 28 M3
203 203 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. b203
204 204 iv) Granite of any colour and shade having Area of slab over 0.50 sqm b204 21 M2
205 205 Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: b205 800 KG
206 206 Steel work in built up tubular (round,square or rectangular hollow tubes etc) trusses etc. including cutting,hoisting fixing in position and applying a priming coat of approved steel primer, including welded and bolted with special shaped washers etc. complete. b206
207 207 i) Hot finished welded type tubes b207 750 KG
208 208 Providing and laying cement plaster on surfaces with Coarse sand including curing etc. b208
209 209 ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand) b209 136 M2
210 210 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : b210 136 M2
211 211 Finishing walls with water proofing cement paint of required shade with Two or more coats applied @ 3.84 kg/10 sqm: b211 136 M2
212 212 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. b212 25 M2
213 213 Installation of supplied 20 KL Tank as per specified drawings as per work description but excluding all works of kerb wall and Gasket for manhole including painting / doping with Shalimastic HD as applicable as per specifications complete. RCC works wherever mentioned shall be of grade M20 b213
214 214 i) In earth pit with RCC strip raft as per standard Drg. ENG/313 b214 3 LS
215 215 Supply, fabrication, laying and testing of MS, BLACK, ERW, threaded pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping b215
216 216 ii) S/L Threaded U/G HD MS Pipes of 80 mm dia with fittings,doping b216 20 M
217 217 iv) S/L Threaded U/G HD MS Pipes of 40 mm dia with fittings,doping b217 4 M
218 218 Supply, fabrication, laying and testing of MS, BLACK, ERW, threaded pipes, heavy class conforming to IS 1239, PART I as per IOCL Specifications including pipeline fittings like bends, tee etc as required and as directed for Above Ground pipeline including surface preparation according to standard SSPC ST2 and painting with 2 coats of red oxide zinc phosphate primer and 2 coats of Synthetic enamel / aluminium finish paint as per IOCL specifications b218
219 219 ii) S/L Threaded A/G HD MS Pipes of 80 mm dia with fittings,Painting b219 1 M
220 220 iv) S/L Threaded A/G HD MS Pipes of 40 mm dia with fittings,Painting b220 18 M
221 221 Supply, fabrication, laying and testing of MS black, ERW welded, pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping b221
222 222 iii) S/L Welded U/G HD MS Pipes of 50mm dia with fittings,doping b222 5 M
223 223 Supply and installation of screwed type gun metal valves as per IOC specifications: Gate Valve b223
224 224 ii) S/I Cast Steel class 150 Flanged Ball Valve of 50 mm dia with nuts,bolts, gaskets etc as per specifications. b224 6 EA
225 225 Supply and installation of ‘U’ type CS bend on the vent pipes including painting as per specifications and supplying and brazing wire mesh of 11 mesh per linear centi-meter of non-corrosive metal in two layers on both ends. b225
226 226 iii) Supply & installation of U type CS bend on vent pipe of 40 mm dia b226 2 EA
227 227 Installation of supplied Multi Product Pumps / Dispensers on pump island as per manufacturers installation manual, drawings, including supplying, providing necessary frame of ISMC 100, foundation bolts, supplying and filling required quantity of dry sand in pit(s) below the pump b227
228 228 i) 2 product - 4 nozzle MPPs/MPDs b228 2 EA
229 229 Air compressor Supply and installation of horizontal air compressor assembly with delivery pressure of 12 kg/sq cm equipped with pressure gauge, non- return/safety/drain/delivery valves, automatic cut-off switch and suitable electrical connections & all standard accessories, including civil works: b229
230 230 iii) Horizontal air compressor Assembly of 5 HP (160-220 LITRES) including civil works b230 1 EA
231 231 Tyre Inflator Supply & installation of Digital tyre inflator which is microprocessor based, automatic air pressure controller with solenoid controlled nozzle for automatic fill and release functions. Complete with weather proof cabinet, 3 digit LED displays with backlight illuminations i.e. one for actual tyre pressure and another for set pressure. Air filter, remote controller, cables, PVC hose pipe and working pressure upto 10bar (Excluding civil work for foundation,etc.) b231 1 EA
232 232 Transportation of equipment from one location to another location including enroute all taxes, levies and unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank same shall be loaded by the tank fabrication contractor) b232
233 233 iii) 15/20 KL Tank with fittings : 0 - 30 Km b233 3 LS
234 234 iv) 15/20 KL Tank with fittings: Add extra for each addtnl. Km above 30km b234 600 KM
235 235 viii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos,0-30 Km b235 3 LS
236 236 ix) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos, Add extra for every additional Km above 30km b236 400 KM
237 237 xii) MPD/MPP pumps upto 2 nos., 0-30 Km b237 1 LS
238 238 xii) MPD/MPP pumps upto 2 nos., Add extra for every additional Km above 30km b238 200 KM
239 239 Replacing existing manhole gaskets for 15/20/50/70 KL U/G & A/G tanks including disconnecting the pipelines, removing nuts, bolts & manhole cover and supplying and fixing permanite oil gaskets, nuts & bolts and reconnecting the pipeline. b239 6 LS
240 240 Supply and fixing Pressure Vacuum Valves of 2 inches for fixing to the Vent Pipes of Underground MS tanks. The valve should be in closed position at normal operating pressure of the tank. The Valve shall be capable for activation at set pressure of 3" ± 0.5 water column to release excess pressure of tank to the atmosphere and open at vacuum of 8" ± 2.0 water column to induce the atmosphere pressure to the tank. PV valve should be diaphragm of dead weight or spring loaded type or combination of any. The weight of the PV valve shall not exceed 2.0 kg. top of the valve shall be provided with cover/cap/ weather hood to prevent the entry of rain water. Valve material,Cover and adopter shall be of Aluminium/polypropylene, diaphragm if used should be of Neoprene, O ring should be of rubber/neoprene, Net/Mesh Pressure puppet ,Vacuum puppet,screws and spring should be of stainless steel. Suitable adopter with one end fitted with valve and the other end should have threading for fixing on Vent pipe of 40mm. PV valves shall have: UL 842 certification of CARB approval or test certificate from any Govt.lab. PV valve shall have PESO approval. b240 1 EA
241 241 Installation of Corporation supplied Standard Submersible Turbine Pump on the existing Manhole Cover as per drawing and direction of Engineer in Charge b241 3 EA
242 242 CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items b242
243 243 iv) 3 Core x 2.5 sq. mm Copper Cable FRLS b243 385 M
244 244 vi) 3 Core x 1.5 sq.mm Copper Cable FRLS b244 65 M
245 245 FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. b245
246 246 vi) 3 Core x 1.5 sq. mm. b246 6 EA
247 247 vii) 3 Core x 2.5 sq. mm b247 18 EA
248 248 PROVISION OF EARTHING b248
249 249 ii) Providing earthing with 80 mm dia,3.0 M long GI (Heavy duty) perforated pipe as per IS:3043 (with latest ammendment) including providing suitable earth bus for interconnection, providing a mixture of salt & charcoal, making earth pit chamber with chequered plate cover as per standard Drwng. etc. all complete as per specif. & direction of Engineer-In-charge b249 2 EA
250 250 Supply & drawing/laying, jointing, connecting, testing and commissioning of earth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : b250
251 251 iii) 50 x 6 mm G.I. Strip b251 300 M
252 252 ii) 32 x 6 mm G.I.strip b252 30 M
253 253 v) 25 x 3 mm GI strip b253 100 M
254 254 vii) 10 S.W.G. G.I. Wire (bare) b254 5 M
255 255 PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032. b255
256 256 Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coil O/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KA for supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement of IOCL. b256 1 EA
257 257 CONSTANT VOLTAGE TRANSFORMER Supplying, installation, testing and commissioning of single phase, air cooled constant voltage transformer of approved make having input voltage range of 180-260V and output voltage of 220/230V with sine wave output wave form and having automatic current limiting and short circuit protection including all accessories complete (for displays) for the following VA ratings. b257
258 258 iii) 500VA CVT b258 3 EA
259 259 Supplying & drawing inside the poles 3 core 2.5 sq.mm PVC insulated flexible copper conductor, fixing of junction box at the pole base (excluding supply of JB), making all connections on both ends, all complete as per specification and direction of Engineer In-charge. b259
260 260 ii) "L" Pole b260 9 EA
261 261 OCTAGONAL POLES Supply & Fixing of Octagonal Poles of following type (Civil job shall be paid separatly) : b261
262 262 iii) S/E of 5 Meter high galvanised Octagonal pole with top 60mm(A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 210 x 210 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides) b262 9 EA
263 263 Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. b263 13 EA
264 264 DISPENSING PUMP CONNECTIONS b264
265 265 ii) Providing dispensing pump power circuit connection with copper conductor single core PVC sheathed wire as per recommendations of the pump manufacturer (make of pumps: L&T /MIDCO /AVERY / Tatsuno/ Nouvopignone) b265 2 EA
266 266 Supply and Laying of 50 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling & back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125. b266 90 M
267 267 Intelligent Line Conditioner (ILC),Suppl b267 1 LS
268 268 As built Drawing for Cable Route & Earth b268 1 LS
269 269 As built Drawing for Pipline Route in C b269 1 LS
270 270 Supply & Fixing of Earthing Clip Box of Size 200x300x400 mm for keeping crocodile clip b270 2 EA
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail