Pipe Line Crossing At Nhai And Railways For Universal Coverage Of Water Supply To Jharsuguda Municipality Pipe Line Crossing At Nhai And Railways For Universal Coverage Of Water Supply To Jharsuguda Municipality 608 Mtrs Of Crossing, Jharsuguda-Odisha

Public Health Engineering Department-PHED has published Pipe Line Crossing At Nhai And Railways For Universal Coverage Of Water Supply To Jharsuguda Municipality Pipe Line Crossing At Nhai And Railways For Universal Coverage Of Water Supply To Jharsuguda Municipality 608 Mtrs Of Crossing. Submission Date for this Tender is 09-12-2020. Pipe Laying Tenders in Jharsuguda Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

26086855
Pipe Line Crossing At Nhai And Railways For Universal Coverage Of Water Supply To Jharsuguda Municipality Pipe Line Crossing At Nhai And Railways For Universal Coverage Of Water Supply To Jharsuguda Municipality 608 Mtrs Of Crossing
Open Tender
Indian
Odisha
Jharsuguda
09-12-2020

Tender Details

Pipe Line Crossing At Nhai And Railways For Universal Coverage Of Water Supply To Jharsuguda Municipality Pipe Line Crossing At Nhai And Railways For Universal Coverage Of Water Supply To Jharsuguda Municipality 608 Mtrs Of Crossing

Key Value

Document Fees
INR 10000 /-
EMD
INR 240000.0 /-
Tender Value
INR 2.39 Crore /-

BOQ Items

Name of Work: Pipe line crossing at NHAI / Railways for Universal coverage of water supply to Jharsuguda Municipality. (608 mtrs of crossing)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Crossing National Highway / R&B Major Roads at different location of Jharsuguda Municipality BI01010001010000000000000515BI0100001113
2 2 Pahadi Mandir Chowk BI01010001010000000000000515BI0100001114
3 3 Supply all material, labour, T&P for crossing of M.S/D.I pipe line across National Highway by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 600 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of National Highway & direction of Engineer-In-Charge & approved by National Highway Department etc all complete. BI01010001010000000000000515BI0100001115
4 4 For 300 mm dia Carrier Pipe BI01010001010000000000000515BI0100001116 30 Mtr
5 5 Providing and laying M.S pipes of all classes confirming to IS:3601 of the following outer diameter with internal cement mortar lining and outside painting etc. all complete as per specification and direction of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work. BI01010001010000000000000515BI0100001117
6 6 610 mm OD & 10mm thick for Casing Pipe BI01010001010000000000000515BI0100001118 30 Mtr
7 7 323.93 mm OD & 7.10mm thick for Carrier Pipe BI01010001010000000000000515BI0100001119 30 Mtr
8 8 Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per direction of Engineer-In-Charge. BI01010001010000000000000515BI0100001120 20 each
9 9 Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification and direction of Engineer-In-Charge. BI01010001010000000000000515BI0100001121 6 Mtr
10 10 Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.0 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.) BI01010001010000000000000515BI0100001122
11 11 300 mm Diameter BI01010001010000000000000515BI0100001123 1 each
12 12 Badheimunda Chowk - I BI01010001010000000000000515BI0100001125
13 13 Supply all material, labour, T&P for crossing of M.S/D.I pipe line across National Highway by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 400 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of National Highway & direction of Engineer-In-Charge & approved by National Highway Department etc all complete. BI01010001010000000000000515BI0100001126
14 14 For 250 mm dia Carrier Pipe BI01010001010000000000000515BI0100001127 33 Mtr
15 15 Providing and laying M.S pipes of all classes confirming to IS:3601 of the following outer diameter with internal cement mortar lining and outside painting etc. all complete as per specification and direction of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work.
16 16 406.4mm OD & 8.8mm thick for Casing Pipe 33 Mtr
17 17 255.6mm OD & 6.3mm thick for Carrier Pipe 33 Mtr
18 18 Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per direction of Engineer-In-Charge. 28 each
19 19 Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification and direction of Engineer-In-Charge. 6 Mtr
20 20 Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.0 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.)
21 21 250 mm Diameter 1 each
22 22 Badheimunda Chowk - II
23 23 Supply all material, labour, T&P for crossing of M.S/D.I pipe line across National Highway by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 400 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of National Highway & direction of Engineer-In-Charge & approved by National Highway Department etc all complete.
24 24 For 200 mm dia Carrier Pipe 40 Mtr
25 25 Providing and laying M.S pipes of all classes confirming to IS:3601 of the following outer diameter with internal cement mortar lining and outside painting etc. all complete as per specification and direction of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work.
26 26 406.4mm OD & 8.8mm thick for Casing Pipe 40 Mtr
27 27 219.1mm OD & 6.3mm thick for Carrier Pipe 40 Mtr
28 28 Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per direction of Engineer-In-Charge. 21 each
29 29 Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification and direction of Engineer-In-Charge. 6 Mtr
30 30 Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.0 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.)
31 31 200 mm Diameter 1 each
32 32 L.N College Square
33 33 Supply all material, labour, T&P for crossing of M.S/D.I pipe line across National Highway by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 300 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of National Highway & direction of Engineer-In-Charge & approved by National Highway Department etc all complete.
34 34 For 150 mm dia Carrier Pipe 37 Mtr
35 35 Providing and laying M.S pipes of all classes confirming to IS:3601 of the following outer diameter with internal cement mortar lining and outside painting etc. all complete as per specification and direction of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work.
36 36 323.93mm OD & 7.10mm thick for Casing Pipe 37 Mtr
37 37 168.3mm OD &5.4mm thick for Carrier Pipe 37 Mtr
38 38 Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per direction of Engineer-In-Charge. 25 each
39 39 Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification and direction of Engineer-In-Charge. 6 Mtr
40 40 Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.0 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.)
41 41 150 mm Diameter 1 each
42 42 Beheramal Chowk -I
43 43 Supply all material, labour, T&P for crossing of M.S/D.I pipe line across National Highway by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 600 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of National Highway & direction of Engineer-In-Charge & approved by National Highway Department etc all complete.
44 44 For 400 mm dia Carrier Pipe 40 Mtr
45 45 Providing and laying M.S pipes of all classes confirming to IS:3601 of the following outer diameter with internal cement mortar lining and outside painting etc. all complete as per specification and direction of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work.
46 46 610 mm OD & 10mm thick for Casing Pipe 40 Mtr
47 47 406.4mm OD & 8.8mm thick for Carrier Pipe 40 Mtr
48 48 Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per direction of Engineer-In-Charge. 21 each
49 49 Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification and direction of Engineer-In-Charge. 6 Mtr
50 50 Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.6 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.)
51 51 400 mm Diameter 1 each
52 52 Beheramal Chowk -II
53 53 Supply all material, labour, T&P for crossing of M.S/D.I pipe line across National Highway by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 400 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of National Highway & direction of Engineer-In-Charge & approved by National Highway Department etc all complete.
54 54 For 200 mm dia Carrier Pipe 40 Mtr
55 55 Providing and laying M.S pipes of all classes confirming to IS:3601 of the following outer diameter with internal cement mortar lining and outside painting etc. all complete as per specification and direction of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work.
56 56 406.4mm OD & 8.8mm thick for Casing Pipe 40 Mtr
57 57 219.1mm OD & 6.3mm thick for Carrier Pipe 40 Mtr
58 58 Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per direction of Engineer-In-Charge. 25 each
59 59 Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification and direction of Engineer-In-Charge. 6 Mtr
60 60 Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.6 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.)
61 61 200 mm Diameter 1 each
62 62 SP Office Square
63 63 Supply all material, labour, T&P for crossing of M.S/D.I pipe line across National Highway by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 600 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of National Highway & direction of Engineer-In-Charge & approved by National Highway Department etc all complete.
64 64 For 400 mm dia Carrier Pipe 40 Mtr
65 65 Providing and laying M.S pipes of all classes confirming to IS:3601 of the following outer diameter with internal cement mortar lining and outside painting etc. all complete as per specification and direction of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work.
66 66 610 mm OD & 10mm thick for Casing Pipe 40 Mtr
67 67 406.4mm OD & 8.8mm thick for Carrier Pipe 40 Mtr
68 68 Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per direction of Engineer-In-Charge. 21 each
69 69 Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification and direction of Engineer-In-Charge. 6 Mtr
70 70 Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.6 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.)
71 71 400 mm Diameter 1 each
72 72 Prasanna Panda Chowk
73 73 Supply all material, labour, T&P for crossing of M.S/D.I pipe line across National Highway by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 600 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of National Highway & direction of Engineer-In-Charge & approved by National Highway Department etc all complete.
74 74 For 400 mm dia Carrier Pipe 54 Mtr
75 75 Providing and laying M.S pipes of all classes confirming to IS:3601 of the following outer diameter with internal cement mortar lining and outside painting etc. all complete as per specification and direction of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work.
76 76 610 mm OD & 12.5mm thick for Casing Pipe 54 Mtr
77 77 406.4mm OD & 8.8mm thick for Carrier Pipe 54 Mtr
78 78 Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per direction of Engineer-In-Charge. 27 each
79 79 Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification and direction of Engineer-In-Charge. 6 Mtr
80 80 Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.6 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.)
81 81 400 mm Diameter 1 each
82 82 Jharianair
83 83 Supply all material, labour, T&P for crossing of M.S/D.I pipe line across National Highway by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 300 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of National Highway & direction of Engineer-In-Charge & approved by National Highway Department etc all complete. 56 Mtr
84 84 For 150 mm dia Carrier Pipe
85 85 Providing and laying M.S pipes of all classes confirming to IS:3601 of the following outer diameter with internal cement mortar lining and outside painting etc. all complete as per specification and direction of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work. 56 Mtr
86 86 323.93 mm OD & 5.6mm thick for Casing Pipe 56 Mtr
87 87 168.3mm OD & 4.5mm thick for Carrier Pipe 27 each
88 88 Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per direction of Engineer-In-Charge. 6 Mtr
89 89 Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification and direction of Engineer-In-Charge.
90 90 Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.0(IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.)
91 91 150 mm Diameter 1 each
92 92 Crossing Railway Track at different location of Jharsuguda Municipality
93 93 Panchpada Road (ROB)
94 94 Supply all material, labour, T&P for crossing of M.S/D.I pipe line across Railway line by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 400 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of Railway Track (BS 105: Guidelines on Pipeline Crossings Under Railway Track) & direction of Engineer-In-Charge & approved by Railway department etc all complete.
95 95 For 200 mm dia Carrier Pipe 46 Mtr
96 96 Supplying all materials, labour and T&P for Providing M.S Pipes of all classes confirming to IS:3589 & IS:3601 of the following outer diameter with internal grit blasted to Sa 2.5 to ISO : 8501-1 followed by 500-700 micron two component 100% soild solvent free liquid epoxy coating all complete as per AWWA-210-07 and diretion of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work.
97 97 406.4mm OD & 8.8mm thick for Casing Pipe 46 Mtr
98 98 219.1mm OD & 6.3mm thick for Carrier Pipe 46 Mtr
99 99 Supplying all materials, labour and T&P for Providing Cathodic Protection system on Casing Pipe all complete as per specification and diretion of Engineer-In-Charge inclduing soil restivity test, supplying of all labour, material, tools & plants required to perferm the work. (the choice of sacrificial anodes for cathodic protection depends upon the soil resistivity valves. If this valve is within 1000 Ohms-cm, Zinc anodes will be used and if the valve in between 1000-7500 Ohms-cm , Mg anodes will be used) 46 Mtr
100 100 Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per specification ((BS 105;Guidelines on Pipeline Crossing under Railway Track) and direction of Engineer-In-Charge. 25 each
101 101 Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification (BS 105:guidelines on Pipeline Crossing under Railway Track) and direction of Engineer-In-Charge. 5 Mtr
102 102 Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.6 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.)
103 103 200 mm Diameter 1 each
104 104 OSAP (ROB)
105 105 Supply all material, labour, T&P for crossing of M.S/D.I pipe line across Railway line by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 400 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of Railway Track (BS 105: Guidelines on Pipeline Crossings Under Railway Track) & direction of Engineer-In-Charge & approved by Railway department etc all complete.
106 106 For 200 mm dia Carrier Pipe 46 Mtr
107 107 Supplying all materials, labour and T&P for Providing M.S Pipes of all classes confirming to IS:3589 & IS:3601 of the following outer diameter with internal grit blasted to Sa 2.5 to ISO : 8501-1 followed by 500-700 micron two component 100% soild solvent free liquid epoxy coating all complete as per AWWA-210-07 and diretion of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work.
108 108 406.4mm OD & 8.8mm thick for Casing Pipe 46 Mtr
109 109 219.1mm OD & 6.3mm thick for Carrier Pipe 46 Mtr
110 110 Supplying all materials, labour and T&P for Providing Cathodic Protection system on Casing Pipe all complete as per specification and diretion of Engineer-In-Charge inclduing soil restivity test, supplying of all labour, material, tools & plants required to perferm the work. (the choice of sacrificial anodes for cathodic protection depends upon the soil resistivity valves. If this valve is within 1000 Ohms-cm, Zinc anodes will be used and if the valve in between 1000-7500 Ohms-cm , Mg anodes will be used) 46 Mtr
111 111 Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per specification ((BS 105;Guidelines on Pipeline Crossing under Railway Track) and direction of Engineer-In-Charge. 23 each
112 112 Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification (BS 105:guidelines on Pipeline Crossing under Railway Track) and direction of Engineer-In-Charge. 6 Mtr
113 113 Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.6 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.)
114 114 200 mm Diameter 1 each
115 115 Balijori (ROB)
116 116 Supply all material, labour, T&P for crossing of M.S/D.I pipe line across Railway line by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 600 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of Railway Track (BS 105: Guidelines on Pipeline Crossings Under Railway Track) & direction of Engineer-In-Charge & approved by Railway department etc all complete.
117 117 For 400 mm dia Carrier Pipe 45 Mtr
118 118 Supplying all materials, labour and T&P for Providing M.S Pipes of all classes confirming to IS:3589 & IS:3601 of the following outer diameter with internal grit blasted to Sa 2.5 to ISO : 8501-1 followed by 500-700 micron two component 100% soild solvent free liquid epoxy coating all complete as per AWWA-210-07 and diretion of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work.
119 119 610mm OD & 10mm thick for Casing Pipe 45 Mtr
120 120 406.4mm OD & 8.8mm thick for Carrier Pipe 45 Mtr
121 121 Supplying all materials, labour and T&P for Providing Cathodic Protection system on Casing Pipe all complete as per specification and diretion of Engineer-In-Charge inclduing soil restivity test, supplying of all labour, material, tools & plants required to perferm the work. (the choice of sacrificial anodes for cathodic protection depends upon the soil resistivity valves. If this valve is within 1000 Ohms-cm, Zinc anodes will be used and if the valve in between 1000-7500 Ohms-cm , Mg anodes will be used) 45 Mtr
122 122 Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per specification ((BS 105;Guidelines on Pipeline Crossing under Railway Track) and direction of Engineer-In-Charge. 25 each
123 123 Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification (BS 105:guidelines on Pipeline Crossing under Railway Track) and direction of Engineer-In-Charge. 6 Mtr
124 124 Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.6 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.)
125 125 400 mm Diameter 1 each
126 126 Balijori
127 127 Supply all material, labour, T&P for crossing of M.S/D.I pipe line across Railway line by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 300 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of Railway Track (BS 105: Guidelines on Pipeline Crossings Under Railway Track) & direction of Engineer-In-Charge & approved by Railway department etc all complete.
128 128 For 150 mm dia Carrier Pipe 30 Mtr
129 129 Supplying all materials, labour and T&P for Providing M.S Pipes of all classes confirming to IS:3589 & IS:3601 of the following outer diameter with internal grit blasted to Sa 2.5 to ISO : 8501-1 followed by 500-700 micron two component 100% soild solvent free liquid epoxy coating all complete as per AWWA-210-07 and diretion of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work.
130 130 323.9mm OD & 5.6mm thick for Casing Pipe 30 Mtr
131 131 168.3mm OD & 5.4mm thick for Carrier Pipe 30 Mtr
132 132 Supplying all materials, labour and T&P for Providing Cathodic Protection system on Casing Pipe all complete as per specification and diretion of Engineer-In-Charge inclduing soil restivity test, supplying of all labour, material, tools & plants required to perferm the work. (the choice of sacrificial anodes for cathodic protection depends upon the soil resistivity valves. If this valve is within 1000 Ohms-cm, Zinc anodes will be used and if the valve in between 1000-7500 Ohms-cm , Mg anodes will be used) 30 Mtr
133 133 Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per specification ((BS 105;Guidelines on Pipeline Crossing under Railway Track) and direction of Engineer-In-Charge. 20 each
134 134 Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification (BS 105:guidelines on Pipeline Crossing under Railway Track) and direction of Engineer-In-Charge. 6 Mtr
135 135 Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.0 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.)
136 136 150 mm Diameter 1 each
137 137 Cox Colony
138 138 Supply all material, labour, T&P for crossing of M.S/D.I pipe line across Railway line by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 600 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of Railway Track (BS 105: Guidelines on Pipeline Crossings Under Railway Track) & direction of Engineer-In-Charge & approved by Railway department etc all complete.
139 139 For 350 mm dia Carrier Pipe 71 Mtr
140 140 Supplying all materials, labour and T&P for Providing M.S Pipes of all classes confirming to IS:3589 & IS:3601 of the following outer diameter with internal grit blasted to Sa 2.5 to ISO : 8501-1 followed by 500-700 micron two component 100% soild solvent free liquid epoxy coating all complete as per AWWA-210-07 and diretion of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work.
141 141 610mm OD & 10mm thick for Casing Pipe 71 Mtr
142 142 355.6mm OD & 8mm thick for Carrier Pipe 71 Mtr
143 143 Supplying all materials, labour and T&P for Providing Cathodic Protection system on Casing Pipe all complete as per specification and diretion of Engineer-In-Charge inclduing soil restivity test, supplying of all labour, material, tools & plants required to perferm the work. (the choice of sacrificial anodes for cathodic protection depends upon the soil resistivity valves. If this valve is within 1000 Ohms-cm, Zinc anodes will be used and if the valve in between 1000-7500 Ohms-cm , Mg anodes will be used) 71 Mtr
144 144 Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per specification ((BS 105;Guidelines on Pipeline Crossing under Railway Track) and direction of Engineer-In-Charge. 37 each
145 145 Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification (BS 105:guidelines on Pipeline Crossing under Railway Track) and direction of Engineer-In-Charge. 5 Mtr
146 146 Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.6 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.)