Public Health Engineering Department-PHED has published Provision For Nhai And Railway Crossings For Pipe Line At Brajrajnagar And Belpahar Municipality For Universal Coverage Of Water Supply Under District Mineral Foundation Funds. Submission Date for this Tender is 09-12-2020. Pipe Laying Tenders in Brajrajnagar Odisha. Bidders can get complete Tender details and download the document.
Name of Work: Provision for NHAI / Railway crossings for pipe line at Brajrajnagar and Belpahar Municipality for Universal Coverage of water supply under District Mineral Foundation Funds | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Crossing National Highway / R&B Major Roads at different location of Brajarajnagar Municipality | BI01010001010000000000000515BI0100001113 | ||
2 | 2 | Muchbahal | BI01010001010000000000000515BI0100001114 | ||
3 | 3 | Supply all material, labour, T&P for crossing of M.S/D.I pipe line across National Highway by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 300 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of National Highway & direction of Engineer-In-Charge & approved by National Highway Department etc all complete. | BI01010001010000000000000515BI0100001115 | ||
4 | 4 | For 100 mm dia Carrier Pipe | BI01010001010000000000000515BI0100001116 | 20 | Mtr |
5 | 5 | Providing and laying M.S pipes of all classes confirming to IS:3601 of the following outer diameter with internal cement mortar lining and outside painting etc. all complete as per specification and direction of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work. | BI01010001010000000000000515BI0100001117 | ||
6 | 6 | 323.9 mm OD & 5.6mm thick for Casing Pipe | BI01010001010000000000000515BI0100001118 | 20 | Mtr |
7 | 7 | 114.3mm OD & 4.5mm thick for Carrier Pipe | BI01010001010000000000000515BI0100001119 | 20 | Mtr |
8 | 8 | Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per direction of Engineer-In-Charge. | BI01010001010000000000000515BI0100001120 | 21 | each |
9 | 9 | Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification and direction of Engineer-In-Charge. | BI01010001010000000000000515BI0100001121 | 17 | Mtr |
10 | 10 | Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.0 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.) | BI01010001010000000000000515BI0100001122 | ||
11 | 11 | 100 mm Diameter | BI01010001010000000000000515BI0100001123 | 1 | each |
12 | 12 | Jurabaga Chhak | |||
13 | 13 | Supply all material, labour, T&P for crossing of M.S/D.I pipe line across National Highway by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 300 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of National Highway & direction of Engineer-In-Charge & approved by National Highway Department etc all complete. | |||
14 | 14 | For 100 mm dia Carrier Pipe | 20 | Mtr | |
15 | 15 | Providing and laying M.S pipes of all classes confirming to IS:3601 of the following outer diameter with internal cement mortar lining and outside painting etc. all complete as per specification and direction of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work. | |||
16 | 16 | 323.9 mm OD & 5.6mm thick for Casing Pipe | 20 | Mtr | |
17 | 17 | 114.3mm OD & 4.5mm thick for Carrier Pipe | 20 | Mtr | |
18 | 18 | Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per direction of Engineer-In-Charge. | 16 | each | |
19 | 19 | Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification and direction of Engineer-In-Charge. | 6 | Mtr | |
20 | 20 | Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.0 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.) | |||
21 | 21 | 100 mm Diameter | 1 | each | |
22 | 22 | Sai Mandir | |||
23 | 23 | Supply all material, labour, T&P for crossing of M.S/D.I pipe line across National Highway by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 300 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of National Highway & direction of Engineer-In-Charge & approved by National Highway Department etc all complete. | |||
24 | 24 | For 100 mm dia Carrier Pipe | 15 | Mtr | |
25 | 25 | Providing and laying M.S pipes of all classes confirming to IS:3601 of the following outer diameter with internal cement mortar lining and outside painting etc. all complete as per specification and direction of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work. | |||
26 | 26 | 323.9 mm OD & 5.6mm thick for Casing Pipe | 15 | Mtr | |
27 | 27 | 114.3mm OD & 4.5mm thick for Carrier Pipe | 15 | Mtr | |
28 | 28 | Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per direction of Engineer-In-Charge. | 6 | each | |
29 | 29 | Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification and direction of Engineer-In-Charge. | 6 | Mtr | |
30 | 30 | Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.0 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.) | |||
31 | 31 | 100 mm Diameter | 1 | each | |
32 | 32 | Rampur Chhak | |||
33 | 33 | Supply all material, labour, T&P for crossing of M.S/D.I pipe line across National Highway by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 300 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of National Highway & direction of Engineer-In-Charge & approved by National Highway Department etc all complete. | |||
34 | 34 | For 100 mm dia Carrier Pipe | 15 | Mtr | |
35 | 35 | Providing and laying M.S pipes of all classes confirming to IS:3601 of the following outer diameter with internal cement mortar lining and outside painting etc. all complete as per specification and direction of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work. | |||
36 | 36 | 323.9 mm OD & 5.6mm thick for Casing Pipe | 15 | Mtr | |
37 | 37 | 114.3mm OD & 4.5mm thick for Carrier Pipe | 15 | Mtr | |
38 | 38 | Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per direction of Engineer-In-Charge. | 15 | each | |
39 | 39 | Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification and direction of Engineer-In-Charge. | 6 | Mtr | |
40 | 40 | Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.0 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.) | |||
41 | 41 | 100 mm Diameter | 1 | each | |
42 | 42 | Lachkura Road | |||
43 | 43 | Supply all material, labour, T&P for crossing of M.S/D.I pipe line across National Highway by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 300 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of National Highway & direction of Engineer-In-Charge & approved by National Highway Department etc all complete. | |||
44 | 44 | For 100 mm dia Carrier Pipe | 15 | Mtr | |
45 | 45 | Providing and laying M.S pipes of all classes confirming to IS:3601 of the following outer diameter with internal cement mortar lining and outside painting etc. all complete as per specification and direction of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work. | |||
46 | 46 | 323.9 mm OD & 5.6mm thick for Casing Pipe | 15 | Mtr | |
47 | 47 | 114.3mm OD & 4.5mm thick for Carrier Pipe | 15 | Mtr | |
48 | 48 | Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per direction of Engineer-In-Charge. | 14 | each | |
49 | 49 | Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification and direction of Engineer-In-Charge. | 6 | Mtr | |
50 | 50 | Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.0 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.) | |||
51 | 51 | 100 mm Diameter | 1 | each | |
52 | 52 | Gandghora | |||
53 | 53 | Supply all material, labour, T&P for crossing of M.S/D.I pipe line across National Highway by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 300 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of National Highway & direction of Engineer-In-Charge & approved by National Highway Department etc all complete. | |||
54 | 54 | For 100 mm dia Carrier Pipe | 15 | Mtr | |
55 | 55 | Providing and laying M.S pipes of all classes confirming to IS:3601 of the following outer diameter with internal cement mortar lining and outside painting etc. all complete as per specification and direction of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work. | |||
56 | 56 | 323.9 mm OD & 5.6mm thick for Casing Pipe | 15 | Mtr | |
57 | 57 | 114.3mm OD & 4.5mm thick for Carrier Pipe | 15 | Mtr | |
58 | 58 | Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per direction of Engineer-In-Charge. | 14 | each | |
59 | 59 | Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification and direction of Engineer-In-Charge. | 6 | Mtr | |
60 | 60 | Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.0 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.) | |||
61 | 61 | 100 mm Diameter | 1 | each | |
62 | 62 | Madhuban Nagar | |||
63 | 63 | Supply all material, labour, T&P for crossing of M.S/D.I pipe line across National Highway by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 300 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of National Highway & direction of Engineer-In-Charge & approved by National Highway Department etc all complete. | |||
64 | 64 | For 100 mm dia Carrier Pipe | 15 | Mtr | |
65 | 65 | Providing and laying M.S pipes of all classes confirming to IS:3601 of the following outer diameter with internal cement mortar lining and outside painting etc. all complete as per specification and direction of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work. | |||
66 | 66 | 323.9 mm OD & 5.6mm thick for Casing Pipe | 15 | Mtr | |
67 | 67 | 114.3mm OD & 4.5mm thick for Carrier Pipe | 15 | Mtr | |
68 | 68 | Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per direction of Engineer-In-Charge. | 14 | each | |
69 | 69 | Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification and direction of Engineer-In-Charge. | 6 | Mtr | |
70 | 70 | Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.0 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.) | |||
71 | 71 | 100 mm Diameter | 1 | each | |
72 | 72 | Crossing Railway Track at different location of Belpahar Municipality | |||
73 | 73 | Belpahar (TRL), Level Crossing | |||
74 | 74 | Supply all material, labour, T&P for crossing of M.S/D.I pipe line across Railway line by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 400 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of Railway Track (BS 105: Guidelines on Pipeline Crossings Under Railway Track) & direction of Engineer-In-Charge & approved by Railway department etc all complete. | |||
75 | 75 | For 200 mm dia Carrier Pipe | 50 | Mtr | |
76 | 76 | Supplying all materials, labour and T&P for Providing M.S Pipes of all classes confirming to IS:3589 & IS:3601 of the following outer diameter with internal grit blasted to Sa 2.5 to ISO : 8501-1 followed by 500-700 micron two component 100% soild solvent free liquid epoxy coating all complete as per AWWA-210-07 and diretion of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work. | |||
77 | 77 | 406.4mm OD & 8.8mm thick for Casing Pipe | 50 | Mtr | |
78 | 78 | 219.1mm OD & 6.3mm thick for Carrier Pipe | 50 | Mtr | |
79 | 79 | Supplying all materials, labour and T&P for Providing Cathodic Protection system on Casing Pipe all complete as per specification and diretion of Engineer-In-Charge inclduing soil restivity test, supplying of all labour, material, tools & plants required to perferm the work. (the choice of sacrificial anodes for cathodic protection depends upon the soil resistivity valves. If this valve is within 1000 Ohms-cm, Zinc anodes will be used and if the valve in between 1000-7500 Ohms-cm , Mg anodes will be used) | 50 | Mtr | |
80 | 80 | Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per specification ((BS 105;Guidelines on Pipeline Crossing under Railway Track) and direction of Engineer-In-Charge. | 35 | each | |
81 | 81 | Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification (BS 105:guidelines on Pipeline Crossing under Railway Track) and direction of Engineer-In-Charge. | 6 | Mtr | |
82 | 82 | Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.6 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.) | |||
83 | 83 | 200 mm Diameter | 1 | each | |
84 | 84 | Jurabaga, Sukha Pattnaik Chhak | |||
85 | 85 | Supply all material, labour, T&P for crossing of M.S/D.I pipe line across Railway line by Horizontal thrust boring method (In slope of 1 in 40 towards downsteam) including encasing the pipe line 350 mm dia inclduing excavation of push pit, dewatering if any, laying & joining of casing & carrier pipe, capping & sealing casing pipe etc for carrier pipe & installation of sign boards on either side of Railway Track (BS 105: Guidelines on Pipeline Crossings Under Railway Track) & direction of Engineer-In-Charge & approved by Railway department etc all complete. | |||
86 | 86 | For 150 mm dia Carrier Pipe | 50 | Mtr | |
87 | 87 | Supplying all materials, labour and T&P for Providing M.S Pipes of all classes confirming to IS:3589 & IS:3601 of the following outer diameter with internal grit blasted to Sa 2.5 to ISO : 8501-1 followed by 500-700 micron two component 100% soild solvent free liquid epoxy coating all complete as per AWWA-210-07 and diretion of Engineer-In-Charge inclduing supplying of all labour, material, tools & plants required to perform the work. | |||
88 | 88 | 355.6mm OD & 5.6mm thick for Casing Pipe | 50 | Mtr | |
89 | 89 | 168.3mm OD & 4.5mm thick for Carrier Pipe | 50 | Mtr | |
90 | 90 | Supplying all materials, labour and T&P for Providing Cathodic Protection system on Casing Pipe all complete as per specification and diretion of Engineer-In-Charge inclduing soil restivity test, supplying of all labour, material, tools & plants required to perferm the work. (the choice of sacrificial anodes for cathodic protection depends upon the soil resistivity valves. If this valve is within 1000 Ohms-cm, Zinc anodes will be used and if the valve in between 1000-7500 Ohms-cm , Mg anodes will be used) | 50 | Mtr | |
91 | 91 | Supply all materials, labour and T&P for providing and fixing High Denisity Polyethylene spacers between casing & Carrier Pipe to avoid contact 2.5m c/c all complete as per specification ((BS 105;Guidelines on Pipeline Crossing under Railway Track) and direction of Engineer-In-Charge. | 35 | each | |
92 | 92 | Supply all materials, labour and T&P for providing and fixing 50 mm Dia Vent / Drain Pipe at both ends of Casing Pipe including cutting, fixing, joing, etc all complete as per specification (BS 105:guidelines on Pipeline Crossing under Railway Track) and direction of Engineer-In-Charge. | 6 | Mtr | |
93 | 93 | Supply, Installation & Testing of Cast Iron Sluice Valve of RATING PN - 1.0 (IS:14846) with double flanged ends for water works purpose conforming to IS:2685 for the following rating and nominal diameters as per specification complete including supplying of all labour, material, tools & plants required to perform the work (inclduing cost of Nut bolt & Washer, Rubber Insertion sheet, etc.) | |||
94 | 94 | 150 mm Diameter | 1 | each |