Electrification Work Of 16 Capacity Hostel/ Barrack And 01 Vivechana Kaksha At Thana Unj , District Sant Ravidas Nagar
Tender Overview
Project Description
Electrification Work Of 16 Capacity Hostel / Barrack And 01 Vivechana Kaksha At Thana Unj , District Sant Ravidas Nagar
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-Nov-2020 | Corrigendum Latter | Date | 01-Dec-2020 |
BOQ
| Name of Work :- Electrification & Extra Related work of 16 Capacity Hostel/Barrack and 01 Vivechana kaksha at Thana Unj, District Sant Ravidasnagar. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC Conduit Concealed in wall complete with 1.5sqmm FRLSH PVC Insulated multistrand copper conductor cable as earth wire drawn inside the conduit, Modular box, modular type switch & ceiling rose/angle/batten holder complete in all respect etc.PS No.131(C)+187(A) | 68 | No's | |
| 2 | 2 | Wiring point for Fan/Fresh Air Fan(light duty exhaust Fan) with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC Conduit Concealed in wall complete with 1.5sqmm FRLSH PVC Insulated multistrand copper conductor cable as earth wire drawn inside the conduit, Modular Box modular type switch & ceiling rose/angle/batten holder complete in all respect etc.PS No.133 (C)+187(A) | 24 | No's | |
| 3 | 3 | Wiring point for Two way Light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC Conduit Concealed in wall complete with 1.5sqmm FRLSH PVC Insulated multistrand copper conductor cable as earth wire drawn inside the conduit, Modular Box modular type switch & ceiling rose/angle/batten holder complete in all respect etc.PS No.132(C)+187(B) | 4 | No's | |
| 4 | 4 | Wiring point for Plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC Conduit Concealed in wall complete with 1.5sqmm FRLSH PVC Insulated multistrand copper conductor cable as earth wire drawn inside the conduit, Modular Box modular type switch & Socket complete in all respect etc.PS No.134(C)+187(C) | 21 | No's | |
| 5 | 5 | Supply and wiring of submain 2.5 Sqmm with two number FRLSH multistrand Copper conductor 20mm dia. heavy duty (2mm thick) PVC conduit with one number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit.PS No.1304(C) | 320 | Mtr's | |
| 6 | 6 | S/wiring of sub main with 2 no 4 sq.mm FRLSH PVC insulated 1100 Volt Grade multi strand single core copper conductor cable in 20 mm dia heavy duty PVC conduit concealded in wall withone no 2.5 sq.mm FRLSH PVC insulated 1100 Volt Grade multi strand single core copper conductor cable as earth wire drawn inside the conduit complete in all respect, PS No.216(C) | 260 | Mtr's | |
| 7 | 7 | S/wiring of sub main with 2 no 10 sq.mm FRLSH PVC insulated 1100 Volt Grade multi strand single core copper conductor cable in 25 mm dia heavy duty PVC conduit concealded in wall withone no 6.0 sq.mm FRLSH PVC insulated 1100 Volt Grade multi strand single core copper conductor cableas earth wire drawn inside the conduit complete in all respect, PS No.218(C) | 96 | Mtr's | |
| 8 | 8 | S/wiring of sub main with 4 no 10 sq.mm FRLSH PVC insulated 1100 Volt Grade multi strand single core copper conductor cable in 25 mm dia heavy duty PVC conduit concealded in wall withone no 6.0 sq.mm FRLSH PVC insulated 1100 Volt Grade multi strand single core copper conductor cableas earth wire drawn inside the conduit complete in all respect, PS No.278(C) | 15 | Mtr's | |
| 9 | 9 | Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface, 2420 system lumens, 110lm/W, PF>0.95, THD<10% complete in all respect., PS No.1413(A) CAT-AAA | 25 | No's | |
| 10 | 10 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection, 8250-9900 system lumens High Power LED with lenses, >110lm/W, THD<10% at full lead, CDI>70, Potted driver complete in all respect., PS No.1423 CAT-AA | 4 | No's | |
| 11 | 11 | Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable Modular box as required etc. complete in all respect.PS No.1139(A) +187(D) | 21 | No's | |
| 12 | 12 | S/o LED Bulb 7 to 9 Watt (Phillips/Havells/Crompton)(AR) | 43 | No's | |
| 13 | 13 | S/o 9-12 watt T bulb(Phillips/Havells/Crompton) as Mirror light (AR) | 4 | No's | |
| 14 | 14 | Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect.PS No.1417 CAT-AA | 5 | No's | |
| 15 | 15.1 | S/Laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100 volt grade at a depth of 750 mm below ground level/on surface the cable run shall be fixed on M S Clampetc of following size \nA- 50 sq.mm x 3½ core cable PS No.501(L) | 75 | Mtr | |
| 16 | 15.2 | S/Laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100 volt grade at a depth of 750 mm below ground level/on surface the cable run shall be fixed on M S Clampetc of following size \nB- 35 sq.mm x 3½ core cable, PS No.501(K) | 40 | Mtr | |
| 17 | 16.1 | S/F Brass nikil plated comression glands as under\nA- 50 sq.mm x 3½ core cable, PS No.503(L) | 1 | No's | |
| 18 | 16.2 | S/F Brass nikil plated comression glands as under\nB- 35 sq.mm x 3½ core cable, PS No.503(L) | 2 | Nos | |
| 19 | 17.1 | S/F of plain or pin type copper tin plated cable socket (Lugs)\nA- 10 sq.mm PS No.504(C) | 20 | No's | |
| 20 | 17.2 | S/F of plain or pin type copper tin plated cable socket (Lugs)\nB- 25 sq.mm, PS No.504(E) | 3 | No's | |
| 21 | 17.3 | S/F of plain or pin type copper tin plated cable socket (Lugs)\nC- 35 sq.mm, PS No.504(F) | 6 | No's | |
| 22 | 17.4 | S/F of plain or pin type copper tin plated cable socket (Lugs)\nD- 50 sq.mm, PS No.504(G) | 1 | No's | |
| 23 | 18 | S/Burying of 600x600x6 mm G I earth plate 3 mtr below ground level with 20 mm dia G I pipe for watring etc complete in all respect, PS No.703 | 2 | No's | |
| 24 | 19 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect.PS No.716 | 35 | Mtr | |
| 25 | 20 | S & F surface/Flush mounting 4ways V TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge.PS No.1026(B) CAT-A | 1 | No's | |
| 26 | 21 | S&F surface/flush mounting 8ways SPN distribution board with additional metal door without MCB complete in all respect, as directed by Engineer in charge.PS No.1024(A) CAT-B | 3 | No's | |
| 27 | 22 | S&F of 63 Amp. DP MCB (10 KA) C Curve, PS No.1011 | 3 | No's | |
| 28 | 23 | S&F of 63 Amp. 4 pole MCB(10 KA) C Curve, PS No.1020(A) CAT-B | 1 | No | |
| 29 | 24 | S/F 6 Amp to 32 Amp SPMCB (10 KA), PS No.1002 CAT-A | 30 | No's | |
| 30 | 25 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's, PS No.811(A) CAT-B\nIncoming- 100A MCCB - 1 Nos\nOutgoing- 63A MCCB - 2 No | 1 | No | |
| 31 | 26 | S&F of 100 Amp. four pole change over switch on 50mm x 50mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge., PS No.378 | 1 | No | |
| 32 | 27 | Erection and testing of ceiling fan and regulator etc Excluding S/o parts, PS No.1115 | 19 | Nos | |
| 33 | 28 | Erection and testing of Freash Air Fan Excluding S/o parts, PS No.1120 | 5 | Nos | |
| 34 | 29 | S/F of Electronic Modular fan regulator 120-280 Volts ISI Marked, PS No.1203(A) | 19 | Nos | |
| 35 | 30 | S/f of Invertor wiring point for Light/Fan/Plug with 1.5sqmm copper wire, PS No.187(A) | 25 | mtr | |
| 36 | 31 | S/f of CO2 Type fire extingusher 4.5 Kg Capacity PS No.1132 | 4 | Nos | |
| 37 | 32 | Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet ade upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work.PS No.1149 | 19 | No's | |
| 38 | 33 | S/F of Ceiling Fan 1200mm (Bajaj/Crompton/Havells), PS No.1501(ii) | 19 | Nos | |
| 39 | 34 | S/F of Air Fresh Fan 300mm (Bajaj/Crompton/Havells) (GEM) | 5 | Nos | |
| 40 | 35 | FIRE FIGHTING SYSTEM\nSupply and fixing of fire extinguisher, ABC Type 9.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PS No.1131 (B) | 12 | Nos | |
| 41 | 36 | Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge.PS No.1133 | 2 | Nos | |
| 42 | 37 | VIVECHANA KAKSHA\nWiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC Conduit Concealed in wall complete with 1.5sqmm FRLSH PVC Insulated multistrand copper conductor cable as earth wire drawn inside the conduit, Modular box, modular type switch & ceiling rose/angle/batten holder complete in all respect etc.PS No.131(C)+187(A) | 18 | No's | |
| 43 | 38 | Wiring point for Fan/Fresh Air Fan(light duty exhaust Fan) with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC Conduit Concealed in wall complete with 1.5sqmm FRLSH PVC Insulated multistrand copper conductor cable as earth wire drawn inside the conduit, Modular Box modular type switch & ceiling rose/angle/batten holder complete in all respect etc.PS No.133(C)+187(A) | 8 | No's | |
| 44 | 39 | Wiring point for Plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC Conduit Concealed in wall complete with 1.5sqmm FRLSH PVC Insulated multistrand copper conductor cable as earth wire drawn inside the conduit, Modular Box modular type switch & Socket complete in all respect etc.PS No.134(C)+187(C) | 10 | No's | |
| 45 | 40 | Wiring point for Call Bell with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC Conduit Concealed in wall complete with 1.5sqmm FRLSH PVC Insulated multistrand copper conductor cable as earth wire drawn inside the conduit, Modular Box modular type bell push or 2 pin socket complete in all respect etc.PS No.135(C)+187(E) | 4 | No's | |
| 46 | 41 | S/f of Sheet Enclouser surface flush mounting fitted with 20A/2 Pin & earth metal clad scrapping earth plug & socket complete in all respect, PS No.1031 CAT-A+1002 CAT-A | 4 | No's | |
| 47 | 42 | Supply and fixing of call bell PS No.1101 | 4 | Nos | |
| 48 | 43 | Supply and wiring of submain 2.5 Sqmm with two number FRLSH multistrand Copper conductor 20mm dia. heavy duty (2mm thick) PVC conduit with one number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduit.PS No.1304(C) | 51 | Mtr's | |
| 49 | 44 | S/wiring of sub main with 2 no 4 sq.mm FRLSH PVC insulated 1100 Volt Grade multi strand single core copper conductor cable in 20 mm dia heavy duty PVC conduit concealded in wall withone no 2.5 sq.mm FRLSH PVC insulated 1100 Volt Grade multi strand single core copper conductor cable as earth wire drawn inside the conduit complete in all respect, PS No.216(C) | 75 | Mtr's | |
| 50 | 45 | Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface, 2420 system lumens, 110lm/W, PF>0.95, THD<10% complete in all respect., PS No.1413(A) CAT-AAA | 6 | No's | |
| 51 | 46 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection, 8250-9900 system lumens High Power LED with lenses, >110lm/W, THD<10% at full lead, CDI>70, Potted driver complete in all respect., PS No.1423 CAT-AA | 2 | No's | |
| 52 | 47 | Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable Modular box as required etc. complete in all respect.PS No.1139(A) +187(D) | 4 | No's | |
| 53 | 48 | S/o LED Bulb 7 to 9 Watt (Phillips/Havells/Crompton)(AR) | 7 | No's | |
| 54 | 49 | S/o 9-12 watt T bulb(Phillips/Havells/Crompton) as Mirror light (AR) | 2 | No's | |
| 55 | 50 | S/Laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100 volt grade at a depth of 750 mm below ground level/on surface the cable run shall be fixed on M S Clampetc of following size \n16 sq.mm x 4 core cable PS No.501(I) | 30 | Mtr | |
| 56 | 51 | S/F Brass nikil plated comression glands as under\n16 sq.mm x 4 core cable, PS No.503(I) | 2 | No's | |
| 57 | 52.1 | S/F of plain or pin type copper tin plated cable socket (Lugs)\nA- 10 sq.mm, PS No.504(C) | 16 | No's | |
| 58 | 52.2 | S/F of plain or pin type copper tin plated cable socket (Lugs)\nB- 16 sq.mm, PS No.504(D) | 8 | No's | |
| 59 | 53 | S/Burying of 600x600x6 mm G I earth plate 3 mtr below ground level with 20 mm dia G I pipe for watring etc complete in all respect., PS No.703 | 1 | No's | |
| 60 | 54 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect.PS No.716 | 10 | Mtr | |
| 61 | 55 | S/F 6 Amp to 32 Amp SPMCB (10 KA), PS No.1002 CAT-A | 12 | No's | |
| 62 | 56 | S & F surface/Flush mounting 4 ways V TPN distribution board with additional door without DPX3 160 MCCB complete in all PS No.1026(B) CAT-A | 1 | No | |
| 63 | 57 | S&F of 100 Amp. 4 pole MCB(10 KA) C Curve, PS No.1021(C) CAT-A | 1 | No's | |
| 64 | 58 | Erection and testing of ceiling fan and regulator etc Excluding S/o parts, PS No.1115 | 6 | Nos | |
| 65 | 59 | Erection and testing of Fresh Air Fan Excluding S/o parts, PS No.1120 | 2 | No's | |
| 66 | 60 | S/F of Electronic Madular fan regulator 120-280 Volts ISI Marked, PS No.1203(A) | 6 | Nos | |
| 67 | 61 | Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work.PS No.1149 | 6 | Nos | |
| 68 | 62 | S/F of Ceiling Fan 1200mm (Bajaj/Crompton/Havells), PS No.1501(ii) | 6 | Nos | |
| 69 | 63 | S/F of Air Fresh Fan 300mm (Bajaj/Crompton/Havells) (GEM) | 2 | Nos | |
| 70 | 64 | GST @12% | 1 | Job |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender