| 1 | 1 | Supply of materials for installation & commissioning of 2 Mwp solar power plant inclusive of , but not limited to the following items Solar pv module , Module Mounting structures,including fasteners & clamps , Array junction boxes with monitoring capabilities , solar module to array junction box interconnection cable , AC cable (LT/HT) of appropriate sizes , power conditioning units . inverters , Transformer’s , Aux. transformer , HT yard as per TANGEDCO specification, metrological station with sensors and loggers ,string level monitoring system (SCADA) & ancillaries , circuit breakers , CT&PT set , 11 KV indoor/outdoor interfacing panels with CT,VCB,PT,Relays, AC&DC distribution panels /boards, PDB,LDB,Control & relay panel ,Lighting arrestor of suitable ratings , Earth mats for switch yard , DC field array equipment ,Control & Power cables , SPD’s & Fuses, earth cables, Flats strips for earthing , Earthing Pits, Rubber mats for specific KV ratings and safety gadgets, PPE ,Fire Extinguisher,Sand buckets , Discharge rods, Interlocking arrangement for VCB & HT yard , UG cable/OH line for for power evacuation with suitable support system till substation Metering set , Solar observatory with remote monitoring assistance , module cleaning system Danger sign plates etc., as per the technical specification including all other charges complete as per director & approval of departmental officers as per the technical specification mentioned in Section - 5 | BI01010001010000000000000515BI0100001117 | 1 | Set |
|---|
| 2 | 2 | Design & Erection , Installation & Commissioning of 2.0 Mwp Ground Mounted solar power plant as per the technical specification mentioned in Annexure ‘A’ | BI01010001010000000000000515BI0100001118 | 1 | Set |
|---|
| 3 | 3 | Cleaning & Levelling the Site using Manual or Machine including all Labour Charges and Hiring Charges as per the Direction of the Departmental officers Etc., Complete. | BI01010001010000000000000515BI0100001119 | 40500 | sq.m |
|---|
| 4 | 4 | Pile foundation : Earth work excavation using hand drill up to height from ground level 1.80 to 2.40 m and 23cm dia including conveyance of excavated earth to sides etc, complete including all labour cost etc, complete. | BI01010001010000000000000515BI0100001120 | 809 | M |
|---|
| 5 | 5 | Conveyance of the excavated earth including debirs up to 2 km by tipper, and depositing in places and spreading etc complete as directed by engineer at site. | BI01010001010000000000000515BI0100001121 | 32.9973 | Cum |
|---|
| 6 | 6 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum | BI01010001010000000000000515BI0100001122 | 32.9973 | Cum |
|---|
| 7 | 7 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification | BI01010001010000000000000515BI0100001123 | 7 | Cum |
|---|
| 8 | 8 | Supplying and erecting SHUTTTERING including necessary supports for plane surfaces such as RCC COLUMN FOOTING, PLINTH BEAM, STAIRCASE STEPS etc., in all floors using mild steel sheets of size 90cm X 60Cm and BG 10 stiffened with welded mild steel angles for boarding supported by Casuarinas props at suitable intervals etc., complete complying with standard specification and as directed. | BI01010001010000000000000515BI0100001124 | | |
|---|
| 9 | 9 | For Grade beam and Footing | BI01010001010000000000000515BI0100001125 | 14 | sqm |
|---|
| 10 | 10 | For Column | BI01010001010000000000000515BI0100001126 | 41 | sqm |
|---|
| 11 | 11 | Supplying and filling in foundation, basement, etc with filling sand in layers of not more than 30 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | BI01010001010000000000000515BI0100001127 | 31.9964 | Cum |
|---|
| 12 | 12 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 | BI01010001010000000000000515BI0100001128 | 50 | Sqm |
|---|
| 13 | 13 | Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors. | BI01010001010000000000000515BI0100001129 | 56 | Qtl |
|---|
| 14 | 14 | Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 400Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards. (No separate payment will be made by the Department for the excess usage of materials) | BI01010001010000000000000515BI0100001130 | 70 | Cum |
|---|
| 15 | 15 | Brick work in CM 1:3 (one cement & five sand) using III class country bricks bricks of size8 3/4\"X43/8\"X 23/4\" standard specification including finishing, curing, etc., complete complying with standard specification - 100cft | BI01010001010000000000000515BI0100001131 | 29.78 | Cum |
|---|
| 16 | 16 | Plastering with cement mortar 1:5(One Cement and five sand),12 mm thick for exposed surface of all rcc works in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications | BI01010001010000000000000515BI0100001132 | 292.003 | Sqm |
|---|
| 17 | 17 | Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m | BI01010001010000000000000515BI0100001133 | 292.003 | Sqm |
|---|
| 18 | 18 | Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coat including the cost all materials etc.,complete, in all floors. | BI01010001010000000000000515BI0100001134 | 425.002 | Sqm |
|---|
| 19 | 19 | Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum | BI01010001010000000000000515BI0100001135 | 2.5988 | Cum |
|---|
| 20 | 20 | Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand ) 20mm thick laid in-situ and pointed with same coloured cement | BI01010001010000000000000515BI0100001136 | 33.499 | Sqm |
|---|
| 21 | 21 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification | BI01010001010000000000000515BI0100001137 | 9686 | kgs |
|---|
| 22 | 22 | Supply and fixing of Chain link - 2\" x 2\" using 10 Gauge Galvanised Iron Wire (of all sizes) allround the ground etc., Complete. As per the direction of the departmental officers | BI01010001010000000000000515BI0100001138 | 2471 | Sqm |
|---|
| 23 | 23 | Supply and fixing of PVC Solid Doors using 19gauge 19mm MS Sq,tubes for styles and frames, 15mm MS Sq.tubes for to, Lock and bottom rails. The Steel Tubes shall be covered with 5mm thick Solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including furniture and fittings. The over all size of styles shall be 50mm X 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm X 30mm. The over all size of frames shall be 50mm X 45mm with suitable tabate for housing the shutter etc, complete as per standard specification | BI01010001010000000000000515BI0100001139 | 4.818 | Sqm |
|---|
| 24 | 24 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 25GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the executive Engineer before use on work | BI01010001010000000000000515BI0100001140 | 4.66 | Sqm |
|---|
| 25 | 25 | ABS DOOR Specification:\nProviding and fixing of ABS (Acrolynitrile Butadiene Styrene)\nDoor using factory made plain FPVC (Foamed Polyvinyl Chloride) door frame of the size 105 x 40mm with a wall thickness of 10mm made out of extruded rigid FPVC profile mitre joined with 10 Nos. of 50mm long screw. The door frame shall be fixed to the wall by using 80mm long screws through the frame with the help of PVC fasteners to be provided for each vertical member, stiffeners of („U? Channel of size 29 x 9 x 1mm, 150mm long) 3 Nos. at hinge point, frame reinforcement of („U? GI Channel of size 46 x 22 x 0.06mm), bottom tie rod of („U? GI Channel size of 15 x 15 x 1mm), the ABS Shutter of 35mm thick factory made plain pre-laminated. ABS (Acrolynitrile Butadiene Styrene) door shutter moulded in different designs, consisting of all round Frame made out of water proof solid foam PVC bar of size 20x32mm, reinforced by 32 x 32mm - 2 Nos. for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm. PVC edge banding of size 0.45mm on the vertical sides. Hardware made out of ball bearing butterfly hinges - 3 Nos. for each shutter and ISI make SS round lock complete, including cost of Materials, conveyance and all other incidental charges and labour charges for fixing the Door neatly etc., complete complying with the standard specification. The door shutter and frame should be got approved from the Executive Engineer before use on work | BI01010001010000000000000515BI0100001141 | 2.58 | Sqm |
|---|
| 26 | 26 | Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with 'P' trap or 'S' trap confirming to IS:2556 - Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers. | BI01010001010000000000000515BI0100001142 | 2 | Each |
|---|
| 27 | 27 | Supplying and fixing of 1200 mm (48\") AC ceiling fan complete with stepped electronic 300 W regulator with 1 m down rod with fan clamp, side plates and cross arm of size departmental officers. (SD 106)(18\") etc., complete as directed by the departemental officers. | BI01010001010000000000000515BI0100001143 | 2 | Each |
|---|
| 28 | 28 | Supplying and fixing of 18w 4 feet LED Fitting with LEDof approved brand (Higher End,Philips,Havells,Equivalent) departmental officers. (SD 106)(18\") etc., complete as directed by the departemental officers. | BI01010001010000000000000515BI0100001144 | 6 | Each |
|---|
| 29 | 29 | Supply and delivery of 25 W LED Street light system made up of pressure die cast aluminium housing with heat resistant toughened glass cover confirming to IP65. Separate compartment for LEDs & electronic driver with CCT of 5700K , PF > 0.9. System efficacy >85. Operating voltage range of 120V to 270V with surge arrestor Minimum of 1KV. Driver current not than 700mA. THD < 10%. Lumens package not less 105 lm/W for LED Source. Test certificate from NABL(National accredited board for Testing & Calibration laboratory) for LM79 report. In house Testing facility to be available for the same, Lamp life not less than 50,000 Hours etc; complete as per Standard Specification. | BI01010001010000000000000515BI0100001145 | 4 | Each |
|---|
| 30 | 30 | Wiring with 2x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall including the cost of cable, pvc pipe and specials, ceiling rose, flush type 5ams SP mark switch, PVC junction box, 16gauge MS switch box 100mm x 100mm x 75mm covered by laminated hylem sheet 3mm thick, cement, labour and making good of concealed portion with suitable colour for concealed PVC LIGHT point.(SD 24) | BI01010001010000000000000515BI0100001146 | 8 | point |
|---|
| 31 | 31 | Supplying and fixing of 5 A 3 pin and 2 pin combined flush type wall socket with 5A flush type switch concealed in suitable MS box in flush with wall and covered with 3mm thick hylem sheet including cost of wall socket, switch and labour charges fo wall cutting, grouting, flushing and making good, painting with primary and finishing coat for MS box etc., complete as directed by the departmental officers. (SD 135) | BI01010001010000000000000515BI0100001147 | 4 | point |
|---|
| 32 | 32 | Supply and fixing 16amps DP switch with metal clad(side handle) of 500 V with F & N on suitable teak wood Board of size 30cmx20cmx6 cm including necessary internal conection,earth connection etc.,complete (SD 142) | BI01010001010000000000000515BI0100001148 | 2 | Each |
|---|
| 33 | 33 | Earthing as per ISI Specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm and with 20mm dia copper earth flat of size 125mm x50mmx6mm, with funneling arrangement using charcoat, common salt, G.I.reducer, checj nuts etc., and mansonry workand providing RCC cover slab 38mm thick for the Brick mansory including cost of steel and fabrication of reinforcement etc., complete in all respectes as directed by the departmental officers. (SD 233) | BI01010001010000000000000515BI0100001149 | 2 | Each |
|---|
| 34 | 34 | Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., co | BI01010001010000000000000515BI0100001150 | 31.5 | sq.m |
|---|
| 35 | 35 | Supply and fixing of TNEB meter Board suitable for 32 A Three phase service connection with 32A fuse unit(500V)32A neutral link and earth link (1\" x 1/8\" Copper flat) on T.W plank of size 600mm x450mm x 19mm with supportingT.W.reepers of 1\" thick oneither sider with painting withsuitable bolt and nuts for fixingthe TW plank on wall withearth connection and interconnection with 7/20 PVCinsulated copper wire from EBmeter to fuse unit. (SD 127) | BI01010001010000000000000515BI0100001151 | 1 | Each |
|---|
| 36 | 36 | Earth work excavation in all soils with initial lead & lift and Refilling the soil etc. complete as per direction of departmental officers including Refilling. | BI01010001010000000000000515BI0100001152 | 405 | Cum |
|---|
| 37 | 37 | Supply and delivery of the following materials approved brand as per list with ISI marking and an approved by corporation officers. | BI01010001010000000000000515BI0100001153 | | |
|---|
| 38 | 38 | 50 mm GI pipe \"B\" class\n | BI01010001010000000000000515BI0100001154 | 1500 | mtr |
|---|
| 39 | 39 | 50 mm GI Bend | BI01010001010000000000000515BI0100001155 | 50 | Nos |
|---|
| 40 | 40 | 50 mm GI Elbow | BI01010001010000000000000515BI0100001156 | 50 | Nos |
|---|
| 41 | 41 | 50 mmGI Tee | BI01010001010000000000000515BI0100001157 | 20 | Nos |
|---|
| 42 | 42 | 50 mm Union | BI01010001010000000000000515BI0100001158 | 20 | Nos |
|---|
| 43 | 43 | 50 mm Flange set | BI01010001010000000000000515BI0100001159 | 20 | Nos |
|---|
| 44 | 44 | 50 mm dia GM Gatevalve | BI01010001010000000000000515BI0100001160 | 10 | Nos |
|---|
| 45 | 45 | 50mm GI coupling | BI01010001010000000000000515BI0100001161 | 330 | Nos |
|---|
| 46 | 46 | 20 mm GI pipe \"B\" class\n | BI01010001010000000000000515BI0100001162 | 60 | mtr |
|---|
| 47 | 47 | 50 ms saddle piece | BI01010001010000000000000515BI0100001163 | 20 | Nos |
|---|
| 48 | 48 | 20 mm GI Bend | BI01010001010000000000000515BI0100001164 | 40 | Nos |
|---|
| 49 | 49 | 20 mm GI Coupling | BI01010001010000000000000515BI0100001165 | 20 | Nos |
|---|
| 50 | 50 | Thread adopter | BI01010001010000000000000515BI0100001166 | 100 | Nos |
|---|
| 51 | 51 | 50mm NRV | BI01010001010000000000000515BI0100001167 | 1 | Nos |
|---|
| 52 | 52 | Clamp set | BI01010001010000000000000515BI0100001168 | 2 | Nos |
|---|
| 53 | 53 | Laying & Jointing of GI pipes & Specials | BI01010001010000000000000515BI0100001169 | 1560 | rm |
|---|
| 54 | 54 | Supply and providing 2000 litres capacity Priming Tank made up of PVC. Make: SINTEX/EQUIVALENT. | BI01010001010000000000000515BI0100001170 | 1 | Nos |
|---|
| 55 | 55 | Operation & Maintenance of 2 Mw solar power plant including transmission lines | BI01010001010000000000000515BI0100001171 | 1 | year |
|---|
| 56 | 56 | Operation & Maintenance of 2 Mw solar power plant including transmission lines | BI01010001010000000000000515BI0100001172 | 1 | year |
|---|
| 57 | 57 | Operation & Maintenance of 2 Mw solar power plant including transmission lines | BI01010001010000000000000515BI0100001173 | 1 | year |
|---|
| 58 | 58 | Operation & Maintenance of 2 Mw solar power plant including transmission lines | BI01010001010000000000000515BI0100001174 | 1 | year |
|---|
| 59 | 59 | Operation & Maintenance of 2 Mw solar power plant including transmission lines | BI01010001010000000000000515BI0100001175 | 1 | year |
|---|
| 60 | 60 | Operation & Maintenance of 2 Mw solar power plant including transmission lines | BI01010001010000000000000515BI0100001176 | 1 | year |
|---|
| 61 | 61 | Operation & Maintenance of 2 Mw solar power plant including transmission lines | BI01010001010000000000000515BI0100001177 | 1 | year |
|---|
| 62 | 62 | Operation & Maintenance of 2 Mw solar power plant including transmission lines | BI01010001010000000000000515BI0100001178 | 1 | year |
|---|
| 63 | 63 | Operation & Maintenance of 2 Mw solar power plant including transmission lines | BI01010001010000000000000515BI0100001179 | 1 | year |
|---|
| 64 | 64 | Operation & Maintenance of 2 Mw solar power plant including transmission lines | BI01010001010000000000000515BI0100001180 | 1 | year |
|---|