Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #26055377

Repair Maintenance Replacement Of Internal Electrification Fittings Fixtures And Connected Accessories In Otm And Md Accn At Phase 1 Rupa Area Of Age Em Under Ge 859 Ews

Issued by Statutory Bodies & Commissions/Committees · TENGA VALLEY, Arunachal Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
02 Dec 2020
0 days left
EMD
30000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
TENGA VALLEY → Arunachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair Maintenance Replacement Of Internal Electrification Fittings Fixtures And Connected Accessories In Otm And Md Accn At Phase 1 Rupa Area Of Age Em Under Ge 859 Ews

BOQ

Nature of Work : REPAIR/ MAINTENANCE/ REPLACEMENT OF INTERNAL ELECTRIFICATION, FITTINGS, FIXTURES AND CONNECTED ACCESSORIES IN OTM AND MD ACCN AT PHASE-1 (RUPA AREA) OF AGE E/M UNDER GE 859 EWS
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Taking down copper/aluminium point wiring (light, Bell, fan, socket or power) complete and removing material to store for keeping in safe custody or for taking credit and making good the disturbed surfaces of wall /ceiling so as to match with the existing finishes complete all as specified and as directed.610Per Point
22M&L for Point wiring with PVC insulated and unsheathed multistranded FRLS copper conductor single core 1.5 Sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping (ISI Mark) with all accessories including providing PVC board heavy duty incl providing plastic laminated bakelite sheet top cover along with copper earth wire PVC insulated & unsheathed multistranded(FRLS) copper conductor cable of size 1.5 Sqmm as continous earth wire connected to common earth and earth dolly complete for one light / fan / bell point controlled by one switch 5/6 Amp.400Per Point
33All as per Srl Item No. 2 here-in-before but for one 3 pin socket outlet 5/6 Amps controlled by one switch on the same board with other switches.80Per Point
44All as per Srl Item No. 2 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one switch independent board.80Per Point
55All as per Srl Item No. 2 here-in-before but for one 15 Amp switch independent with PVC insulated and unsheathed multistranded FRLS copper conductor single core 4.0 Sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping(ISI Mark) with all accessories including providing PVC board heavy duty incl providing plastic laminated bakelite sheet top cover alongwith copper earth wire PVC insulated & unsheathed multistranded(FRLS) copper conductor cable of size 4.0 Sqmm as continous earth wire connected to common earth and earth dolly.50Per Point
66M&L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly including taking down unserviceable one and making good to disturbed surfaces complete all as specified and directed. \n\nNOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one unit.100RM
77M&L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly including taking down unserviceable one and making good to disturbed surfaces complete all as specified and directed. \n\nNOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one unit.100RM
88S&F switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed.380Each
99S&F switch socket combination 2 in 1, 3 pin, 6 Amp piano flush type (ISI marked), 240 Volts complete all as specified & directed.160Each
1010S&F switch socket combination 2 in 1, 3 pin, 16/15 Amp piano flush type (ISI marked), 240 Volts complete all as specified & directed.50Each
1111S&F bell push piano type one way 5/6 Amp, 240 volt complete all as specified & directed.20Each
1212S&F ceiling rose, surface bakelite, 65mm x 50mm , two to three terminals including taking down unserviceable one complete all as specified & directed.144Each
1313S&F lamp holder insulated body with back plate suitable for batten fittings including taking down unserviceable one complete all as specified & directed.216Each
1414S&F bell electric AC 240 volt, 50 HZ complete all as specified & directed.20Each
1515Fixing only LED Tube Light Fitting on mounting casing box 2 Nos including taking down old / unserviceable one complete all as specified and directed. Note :- LED Tube Light Fittings will be issued under Sch 'B' free for fixing.144Each
1616S&F Wall mounted Mirror light LED fitting, 14/11 Watt, 2 Feet long incl integrated electronic driver including dismantling taking down unsv fitting any type complete all as specified and directed. Make : Havells/Philips/Bajaj/CG/Eveready15Each
1717S&F Square shaped recess/suspended mounted environment friendly new generation asthetically ultra modern with high brightness LEDs as light source LED Flat panel, 42 watt, 2'x2'size, complete with driver and all accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismentling taking down unsv fitting any type complete all as specified and directed. Make: Havells Cat Part No PLUTONEO2X2PLR42WLED840S or equivalent in Philips/Bajaj/CG/Eveready15Each
1818S&F round shaped recess mounted slim fit down lighter having latest edge lit LED techonology environment friendly, 18 watt complete with driver and all accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismantling taking down unsv fitting any type complete all as specified and directed. Make: Havells Cat Part No EDGEPRORDDLR18WLED840S or equivalent in Philips/Bajaj/CG/Eveready15Each
1919S&F round shaped surface mounted LED down lighter with white powder coated aluminium housing with intigerated driver, 18 watt complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismantling taking down unsv fitting any type complete all as specified and directed. Make: Havells Cat Part No ENDURANEOHESURFACEDLS18WLED840S or equivalent in Philips/Bajaj/CG/Eveready15Each
2020S&F LED building security light 30 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable incl dismantling taking down unsv fitting any type complete all as specified and directed. \nMake: Havells Cat Part No ENDURA PEARL SL 30W LED 757 SASYTOPCMP or equivalent in Philips/Bajaj/CG/Eveready40Each
2121S&F environmental friendly, ultra modern, energy saving, surface mounted decorative hexagon LED bulk head 10W including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable including taking down unserviceable one complete all as specified and directed. Make : Havells- Cat Part No LHEOAOP7UZ6W010 or equivalent in Philips / Bajaj / CG/ Eveready20Each
2222Fixing only LED Bulb including taking down old / unserviceable one complete all as specified and directed. Note :- LED Bulb will be issued under Sch 'B' free for fixing.216Each
2323S&F MCB DB CRCA sheet powder coated vertical type TPN 6 way double door factory made suitable for incorporating MCB as out going and MCCB as incoming including connecting incoming and outgoing cables incl taking downt existing unsv DB of any size and making good distrubed surface to match with existing complete all as specified and as directed. \n2Each
2424S&F MCB DB CRCA sheet powder coated SPN 4 way single door factory made suitable for incorporating MCB as out going connecting incoming and outgoing cables including taking out existing unserviceable DB of any size and making good disturbed surface to match with existing complete all as specified and as directed.5Each
2525S&F MCB DB CRCA sheet powder coated SPN 8 way double door factory made suitable for incorporating MCB as out going connecting incoming and outgoing cables incl taking out existing unsv DB of any size and making good disturbed surface to match with existing complete all as specified and as directed.10Each
2626S&F MCCB 100 Amps, Four Pole, 25 KA 415 Volt including taking down unserviceable one complete all as specified and as directed. Make : Havells/L&T/ABB/Schneider/Legrand2Each
2727S&F MCB SPN having braking capacity 10 KA. 35 to 60 Amp, 240 volts C curve including taking down unserviceable one complete all as specified and as directed.25Each
2828S&F MCB single pole having braking capacity 10 KA, 6 to 32 Amps 240 volts including taking down unserviceable one complete all as specified and as directed.70Each
2929S&F MCB isolator TPN having braking capacity 63 Amps 415 volts, 50 Hz including taking down unserviceable one complete all as specified and as directed.11Each
3030S&F PVC insulated PVC sheathed copper flexible wire multistrand 4 sqmm 3 core, ISI marked, FRLS grade including taking down old unsv one all as specified and directed. \n50Each
3131S&F in repair thermostat ISI marked suitable for geysers 25 Ltrs to 50 Ltrs Capacity complete all as specified and directed.10Each
3232S&F in repair fusible plug ISI marked suitable for 25 to 50 ltrs capacity Geysers complete all as specified and directed.10Each
3333S&F in repair heating element ISI Marked round/triangular bas, push type or thread type including rubber washers for 1.5/2.0 KW suitable for 25 to 50 ltr capacity Geysers complete all as specified and directed.25Each
3434S&F in repair innner water container ISI Marked made of stainless steel, vertical or horizontal type suitable for existing 25 ltr capacity geyser complete all as specified and directed.5Each
3535S&F in repair outer body container ISI Marked, vertical or horizontal type suitable for existing 25 ltr capacity geyser complete all as specified and directed.5Each
3636S&F in repair innner water container ISI Marked made of stainless steel, vertical or horizontal type suitable for existing 50 ltr capacity geyser complete all as specified and directed.5Each
3737S&F in repair outer body container ISI Marked, vertical or horizontal type suitable for existing 50 ltr capacity geyser complete all as specified and directed.5Each
3838S&F in repair apparatus plate ISI marked suitable for vertical/horizintal type Geyser 25 to 50 ltr cap complete all as specified and directed.5Each
3939S&F in repair heavy duty PVC connections pipe with brass hexagonal adoptersat both side 15mm dia and 450mm long for hot /cold water all as specified and directed.28Each
4040M&L for Rewinding of Exhaust fan 250/300 mm sweep after dismenting complete motor assy, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, vernishing, replacement of unsv bearings / bushings, blades and testing complete. \nNote: 1. Contractor will collect fans from the complaint cells of specified area and bring back to complaint cell after repair. Cost of transportation will be inclusive of quoted rate.\n2. Spares require for replacement such as bearing, blade, capacitor, shall be measured and paid separately as supply only. \n7Each
4141Supply only ball bearing of size 6201/6202/6203 suitable for exhaust fan 250/300 mm sweep as per manufacture instruction complete all as specified and directed.7Each
4242Supply only fan condensor cap 1/1.8 MFD suitable for exhaust fan 250/300 mm sweep as per manufacture instruction complete all as specified and directed.7Each
4343Supply only louvers suitable for exhaust fan 250/300mm sweep with necessary fixing arrangement complete all as specified and directed.7Each
4444S&F Exhaust fan motor suitable for exhaust fan 250/300 mm sweep as per site requirement complete including necessary fixing complete all as specified and directed.7Each
4545S&F 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 10 sqmm, 2 core and overall PVC sheathed in service connections including taking down old unserviceable one all as specified and directed.1000RM
4646M&L for Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit nbot less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI wire protection pipe 25mm bore up to main board complete as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and as directed. \nNote:- The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 25mm GI pipe (light grade) for watering 25mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.2Each Set

AI Tender Summary

OUR REF NO 26055377
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 02-12-2020
Authority
Authority Name Military Engineer Services
Work Description Repair Maintenance Replacement Of Internal Electrification Fittings Fixtures And Connected Accessories In Otm And Md Accn At Phase 1 Rupa Area Of Age Em Under Ge 859 Ews
Basic Detail
Tender No 8142
Bidding Type Tender
Location
City TENGA VALLEY
State Arunachal Pradesh
Key Dates
Publish Date 20 Nov 2020
Submission Date 02 Dec 2020
Open Date 04 Dec 2020
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 30000
Exemption Not Available
Document List
Tendernotice_1.pdf
BOQ_442762.xls
EF1CC55E-9551-41EA-9D6B-DAAA450943F7.html
Tenderdocs.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 02, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 04, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

xls

BOQ_442762.xls

html

EF1CC55E-9551-41EA-9D6B-DAAA450943F7.html

pdf

Tenderdocs.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail