| 1 | 1 | M&L for repairs to geysers by disconnecting the electrical and water supply connctions, repairs to inner container by brazing and welding and checking for any leakages and carrying out leak proof test at 2.5 Kg/sqcm, with and including two coats of painting with synthetic enamel paint and fixing the geyser and connecting electrical and water supply connections in same or different locations complete all as specified and as directed. | | 120 | Each Job |
|---|
| 2 | 2 | S&F in replacement of heating element ISI marked 1500 watts, 230 volts complete all as specified and as directed. | | 60 | Each |
|---|
| 3 | 3 | S&F in replacement of heating element ISI marked 2000 watts, 230 volts complete all as specified and as directed. | | 60 | Each |
|---|
| 4 | 4 | S&F in replacement of Thermostat ISI marked, temperature range 45°C to 100° C, 230 volts complete all as specified and as directed. | | 100 | Each |
|---|
| 5 | 5 | S&F in replacement lamp indicator for geyser (Red / Green) including bulb and connections complete all as specified and as directed. | | 80 | Each |
|---|
| 6 | 6 | S&F in replacement CI Sluice valve confirming to IS 14846 – 2000, PN-1.0, both ends flanged, stainless spindle of following sizes with necessary packing materials and nut, bolts including taking down existing sluice valve complete all as specified and as directed:- (a) 80 mm bore | | 2 | Each |
|---|
| 7 | 7 | (b) 100 mm bore | | 2 | Each |
|---|
| 8 | 8 | (c) 150 mm bore | | 1 | Each |
|---|
| 9 | 9 | M&L in repair for construction of brick masonary valve pits including plaster 10 mm thick in cement (1:6) internally and exposed surface of outer face and PCC (1:4:8) type D2 in foundation base and PCC (1:2:4) type B1 copping on top surface of valve pit including 3 mm thick MS plate cover with locking arrangements and angle iron frame of (40 x 40)mm x 6 mm thick complete all as specified and shown on TD including necessary excavation and earth work complete of the following sizes:- (a) Internal dimensions (60 x 60)cm x 60 cm depth | | 1 | Each |
|---|
| 10 | 10 | (b) Internal dimensions (90 x 90)cm x 90 cm depth | | 1 | Each |
|---|
| 11 | 11 | (b) Internal dimensions (120 x 120)cm x 90 cm depth | | 1 | Each |
|---|
| 12 | 12 | Supply & fixing DOL Starter 415 V, 3 Phase up to 10 HP complete all as specified and as directed. Make:- cat part no SS94351 of Make L&T / HPL or equivalent as per makes. | | 1 | Each |
|---|
| 13 | 13 | Supply & fixing 250mm size CI non return valve IS 5312 complete all as specified and as directed. | | 1 | Each |
|---|
| 14 | 14 | M&L earthing complete with GI earth plate electrode of size (60cm x 60cm) x6 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to galvanised earth wire of size (32x6) mm by means of nuts, bolts, check nuts & washers made out of galvanised iron or steel earth wire protected by galvanised iron pipe 20mm bore (medium grade) and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 pre-cast RCC cover slab 30cm x 30 cm x 10cm with one handle for lifting made out of 8mm dia MS bar, funnel wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in hard/dense soil complete all other accessories as shown on electrical plate No 3 of MES Sch Pt-I all as specified and directed. | | 2 | Each set |
|---|
| 15 | 15 | Material and labour taking up/down capacity 100 HP centrifugal pump, opening and dismantling from the position after repair from workshop of pump, refixing the same position for smooth functioning of pumping set and repalcement of following items (a) Bearing roller type bearing No 21309 -01 No (b) Bearing roller type bearing No 3309 -01 No (c) Shaft welding & machining (d) Body assemble & machinning with opening and fitting (e) Chabbi machining and and fitting (f) Coupling bushing and boring (g) Neck ring policing -2 Nos (h) Nut bolt washer & greasing | | 3 | Each job |
|---|
| 16 | 16 | M&L for opening the burnt motor 100 HP, 415 volts and rewinding the same by super enamel copper wire as per existing size/gauge including provision of new insulating material, varnishing, and fixing of new bearing both side (bearing Sl No-NU318 SKF and 6218SKF) complete as testing at full load and commissioning as specified and directed. | | 2 | Each Job |
|---|
| 17 | 17 | M&L for opening the burnt motor 30 HP, 415 volts and rewinding the same by super enamel copper wire as per existing size/gauge including provision of new insulating material, varnishing, and fixing of new bearing both side complete as testing at full load and commissioning complete all as specified and as directed. | | 1 | Each Job |
|---|
| 18 | 18 | M&L for opening the burnt motor 10 HP, 415 volts and rewinding the same by super enamel copper wire as per existing size/gauge including provision of new insulating material, varnishing, and fixing of new bearing both side complete as testing at full load and commissioning as specified and directed. | | 1 | Each Job |
|---|
| 19 | 19 | Supply & fix suction sweeper nylon brush 36\" long for sweeper swimming pool for cleaner complete all as specified and as directed. Make : RMCO or Equivelent | | 2 | Each |
|---|
| 20 | 20 | S&F suction sweeper wheel suitable for 36\" long for sweeper swimming pool for cleaner complete all as specified and as directed. Make : RMCO or Equivelent | | 12 | Each |
|---|
| 21 | 21 | Material and labour for cleaning / washing mechanically fire extinguisher capacity 135 Ltrs and making the good disturbed surface for reuse the fire extinguisher and refilling CO2 for fire extenguishers after conducting hydraulic testing, painting and reinstallation complete all as specified and as directed by Engr-in-charge . Note : The cost of unserviceable Spare / parts shall deemed to be included in quoted rate. | | 4 | Each Job |
|---|
| 22 | 22 | Material and labour for cleaning / washing mechanically fire extinguisher capacity 22 KH / LTR and making the good disturbed surface for reuse the fire extinguisher and refilling CO2 for fire extenguishers after conducting hydraulic testing, painting and reinstallation complete all as specified and as directed by Engr-in-charge . Note : The cost of unserviceable Spare / parts shall deemed to be included in quoted rate. | | 2 | Each Job |
|---|
| 23 | 23 | M&L for repair/servicing to 40 HD high pressure single head adjustable gear motor dosing pump of 40 HD capacity by replacement of un-serviceable parts i.e pump tube, suction/discharge tubing, inject check valve, foot ball, adaptor with connectng nut, duck bill, coneecting nut, valve o ring rotor assembly coil roller assembly and terminal/lugs nut bolts, cleaning / repairing of as required at site complete including testing of dosing pump sets to check the smooth functioning all as directed at site:- Note:- (a) Spare/ parts like pump tube, suction/discharge tubing, inject check valve, foot ball, adaptor with connectng nut, duck bill, coneecting nut, valve o ring rotor assembly coil roller assembly (b) Capacity of Dosing pump sets Dosing pump RPQ 40 HD | | 7 | Each Job |
|---|
| 24 | 24 | Pump Tube | | 7 | Each set |
|---|
| 25 | 25 | Suction/discharge tubing | | 7 | Each |
|---|
| 26 | 26 | Inject check valve | | 7 | Each |
|---|
| 27 | 27 | Foot ball | | 7 | Each |
|---|
| 28 | 28 | Adaptor with connectng nut, | | 7 | Each |
|---|
| 29 | 29 | Duck bill | | 7 | Each |
|---|
| 30 | 30 | Coneecting nut | | 7 | Each |
|---|
| 31 | 31 | Valve o ring | | 7 | Each |
|---|
| 32 | 32 | Rotor assembly with bearing bracket etc. | | 7 | Each |
|---|
| 33 | 33 | Coil | | 7 | Each |
|---|
| 34 | 34 | Roller assembly | | 7 | Each |
|---|
| 35 | 35 | Supply & fix UPVC pipe 20 mm dia grade I including socket, Elbow, Tee, nipple, etc. all as specified and directed | | 100 | Rm |
|---|
| 36 | 36 | Supply & fix gate valve 20 mm dia all as specified and directed. | | 7 | Each |
|---|