Repair , Maintenance Of Internal Electrification System And Other Allied Works At Afs Begumpet Under Ge ( Af ) Hakimpet
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Dec 2020
0 days left
EMD
49000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
BEGUMPET → Telangana
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair , Maintenance Of Internal Electrification System And Other Allied Works At Afs Begumpet Under Ge ( Af ) Hakimpet
BOQ
| NAME OF WORK :REPAIR, MAINTENANCE OF INTERNAL ELECTRIFICATION SYSTEM AND OTHER ALLIED WORKS AT AFS BEGUMPET UNDER GE(AF) HAKIMPET | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Taking down copper / aluminum point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, lamp holders, light fittings etc removing materials and making good disturbed surfaces of walls, floors etc, including paint tuch up to match with the existing surface as per site requirement, complete all as specified and directed. | 790 | Point | |
| 2 | 2 | M&L for Point wiring complete with 1.5 Sqmm single core PVC insulated FRLS cable, with multi standard copper conductors, 1100 volts grade, drawn thorough and including double locking type PVC casing and caping and its accessories of suitable size and including provisoin of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor, fabricated steel teminal box made out of 1.60 mm thick MS sheet concealed in walls and covered with 3 mm thick hylum sheet for fixing the switches /sockets/ regulators etc, complete all as specified and directed for the following:- | |||
| 3 | 2.01 | One light point controlled by one one way switch. | 100 | Point | |
| 4 | 2.02 | One light point controlled by Two 2-way switch. | 12 | Point | |
| 5 | 2.03 | One ceiling fan/ exhaut fan point controlled by one one way switch. | 40 | Point | |
| 6 | 2.04 | One 3 pin socket outlet 5 Amps on the same board with other switches. | 40 | Point | |
| 7 | 2.05 | One 3 pin 5 Amps socket outlet the switch board of light point in the same vertical plane. | 40 | Point | |
| 8 | 2.06 | One 3 pin socket outlet 5 Amps on the Independent board. | 40 | Point | |
| 9 | 2.07 | One bell/ buzzer point controlled by one push button on the same board with other switches or independent. | 15 | Point | |
| 10 | 3 | All as per item No. 2 here-in-before but with 4.0 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor, complete all as specified and directed.\n | 25 | Point | |
| 11 | 4 | All as per item No. 2 here-in-before but conductor drawn through stove enamelled steel conduit (Surface) for one light point controlled by one flame proof switch complete all as specified and directed. | 4 | Point | |
| 12 | 5 | S&F Switch piano flush type, single pole one way 5 Amps 240 volts, complete all as specified and directed. | 280 | Each | |
| 13 | 6 | Supply and fix Switch Piano flush type two way 5 Amps, complete all as specified and directed. | 48 | Each | |
| 14 | 7 | Supply and fix Switch socket combination 2 in 1, 5 Amps flush type, complete all as specified and directed. | 245 | Each | |
| 15 | 8 | Supply and fix Switch socket combination, 3 pin, 5 and 15A, 5 IN 1 flush type, complete all as specified and directed. | 55 | Each | |
| 16 | 9 | Supply and fix Switch bell push 5 Amps flush type, complete all as specified and directed. | 30 | Each | |
| 17 | 10 | S&F Stepped type electronic fan regulator flush type, complete all as specified and directed. | 64 | Each | |
| 18 | 11 | S&F Ceiling rose PVC/ Polycorbonate insulated body with three terminals. | 364 | Each | |
| 19 | 12 | S&F CMRI Certified LED Flameproof 2X16/20W LED Tube Light fixture and including LED tube-02 Nos recommended for gas / vapour group IP 65 Protection with complete fittings and accessories, complete all as specified and directed. Make : Crompton EXTN2LT8-16/20 or equivalent make of M/S Shyam Switchgears / M/S Sudhir / M/S Baliga as approved by GE. | 4 | Each | |
| 20 | 13 | S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V. Make : M/S Shyam Switchgears / M/S Sudhir / M/S Baliga | 4 | Each | |
| 21 | 14 | M&L for Point wiring complete with 1.5 sq mm single core PVC insulated FRLS cable, with multi standard copper conductors, 1100 volts grade, drawn thorough and including non metalic, medium grade rigid PVC conduit with all conduit accessories (including concealing and finising to match with the sorroundings) and including provisoin of 1.5 Sqmm PVC indulated copper cable FRLS as earth continiuty conductor, fabricated steel teminal box made out MS sheet suitable for Modular switches concealed in walls with front cover & base frame, screws, suitable for housing modular switches, socket outlets, fan regulators etc, all as specified and as directed for the following:- | |||
| 22 | 14.01 | One light point controlled by one way switch | 40 | Point | |
| 23 | 14.02 | One ceiling fan/ exhaut fan point controlled by one way switch. | 20 | Point | |
| 24 | 14.03 | One 3 pin socket outlet 5 Amps on the same board with other switches. | 20 | Point | |
| 25 | 14.04 | One 3 pin 5 Amps socket outlet the switch board of light point ini the same vertical plane. | 20 | Point | |
| 26 | 14.05 | One 3 pin socket outlet 5 Amps on the Independent board. | 20 | Point | |
| 27 | 14.06 | One bell/ buzzer point controlled by one push button independent. | 12 | Point | |
| 28 | 15 | All as per item No. 14 here-in-before but with 4 Sqmm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor, complete all as specified and directed. | 20 | Point | |
| 29 | 16 | Supply and fix Modular switch 6A, 1 way, complete all as specified and directed. | 120 | Each | |
| 30 | 17 | Supply and fix Modular switch 16A, 1 way, complete all as specified and directed. | 20 | Each | |
| 31 | 18 | Supply and fix Socket outlet 6A modular, complete all as specified and directed. | 60 | Each | |
| 32 | 19 | Supply and fix Socket outlet 16A modular, complete all as specified and directed. | 20 | Each | |
| 33 | 20 | Supply and fix switch bell push modular, complete all as specified and directed. | 12 | Each | |
| 34 | 21 | Supply and fix Fan Step regulator, 120 W-2 modular, complete all as specified and directed. | 20 | Each | |
| 35 | 22 | Supply and fix bell, Ding Dong AC, 230 volts, SP, complete all as specified and directed. | 10 | Each | |
| 36 | 23 | Taking down unserviceable sub main wiring of any description and M&L for sub main wiring with 2x4.0 Sq mm and 1x2.5 Sqmm (Earth), FRLS PVC insulated, unsheathed, multi-stranded, 1100 volts grade copper conductor calbe, single core, drawn through and including double locked type PVC casing & Capping and its all accessories of suitable size on wall/ roof surfaces, complete all as specified and directed. Note: Three runs 4/2.5 Sqmm copper cable and one run of suitable width of PVC casing and caping shall be measured as one unit length. | 120 | RM | |
| 37 | 24 | Desrciption all as per item No. 23 here-in-before but with 2x6.0 Sqmm and 1x4 Sqmm (Earth), complete all as specified and directed. Note: Three runs 6/4 Sq mm copper cable and one run of suitable width of PVC casing and caping shall be measured as one unit length. | 90 | RM | |
| 38 | 25 | Desrciption all as per item No. 23 here-in-before but with 4x6.0 Sqmm (3Ph+1N) + 2x 4 Sq mm (Earth), complete all as specified and directed. Note: Six runs 6/4 Sqmm copper cable and one run of suitable width of PVC casing and caping shall be measured as one unit length. | 60 | RM | |
| 39 | 26 | Desrciption all as per item No. 23 here-in-before but with 4x10.0 Sqmm (3Ph+1N) + 2x 6 Sqmm (Earth), complete all as specified and directed. Note: Six runs 10/6 Sqmm copper cable and one run of suitable width of PVC casing and caping shall be measured as one unit length. | 30 | RM | |
| 40 | 27 | Supply and fix in repairs including taking down the following Items:- | |||
| 41 | 27.01 | Electronic ballast suitable for 1x36/ 40 watts FTL. Make: Havells/Phillips, HPL, Crompton greaves. | 120 | Each | |
| 42 | 27.02 | Electronic ballast suitable for 1x28 Watts (T-5) EEFTL. Make: Havells,Phillips, HPL, Crompton greaves. | 20 | Each | |
| 43 | 27.03 | Starter 110V/220V suitable for 20/40 watt FTL. Make: HPL, phillips, Havells , crmpton greaves | 90 | Each | |
| 44 | 27.04 | Lamp holder PVC/ Polycarbonate type with back plate suitable for batten/ angular type. | 50 | Each | |
| 45 | 27.05 | Ceiling rose PVC/ Polycorbonate insulated body with three terminals. | 50 | Each | |
| 46 | 27.06 | Switch Piano, flush type single pole, one way 5 Amps. | 80 | Each | |
| 47 | 27.07 | Switch Piano flush type two way 5 Amps. | 20 | Each | |
| 48 | 27.08 | Switch socket combination 2 in 1, 5 Amps flush type. | 60 | Each | |
| 49 | 27.09 | Switch socket combination, 3 pin, 5 and 15A, 5 in 1 flush type. | 60 | Each | |
| 50 | 27.1 | Switch bell push 5 Amps flush type. | 30 | Each | |
| 51 | 27.11 | Stepped type electronic fan regulator flush type. | 50 | Each | |
| 52 | 27.12 | Modular switch 6A, 1 way. | 60 | Each | |
| 53 | 27.13 | Modular switch 16A, 1 way. | 40 | Each | |
| 54 | 27.14 | Socket outlet 6A modular. | 50 | Each | |
| 55 | 27.15 | Socket outlet 16A modular. | 40 | RM | |
| 56 | 27.16 | Switch bell push modular. | 40 | Each | |
| 57 | 27.17 | Fan Step regulator, 120 W-2 modular. | 50 | Each | |
| 58 | 27.18 | Bell, Ding Dong AC, 230 volts, SP. | 30 | Each | |
| 59 | 27.19 | Surface mounting PVC/Poly carbonate Box suitable for fixing 5A Switch socket over existing wall | 20 | Each | |
| 60 | 27.2 | Surface mounting PVC/Poly carbonate Box suitable for fixing 15A Switch socket over existing wall | 10 | Each | |
| 61 | 27.21 | Plug top polycarbonate 3 pin 5 Amps. Make : Legrand/Crabtreet/Anchor/Havells | 10 | Each | |
| 62 | 28 | S&F Surface and wall mounted 9W LED 6K, 600X25x40 (LXWXH) batten, polycarbonate housing & integrated electronic driver ready to use pack etc. complete with all accessories internally pre-wired and fixing and connecting up with twin core twisted flexible copper conductor cable with suitable size upto ceiling rose, complete all as specified and directed. Make: Havells Model No: LUMILINEBS9WLED840SPCWH or equivalent in Phillips/ CG / Bajaj. | 100 | Each | |
| 63 | 29 | S&F Surface and wall mounted 20W LED 6K, 1150X25x40 (LXWXH) batten, polycarbonate housing & integrated electronic driver ready to use pack etc. complete with all accessories internally pre-wired and fixing and connecting up with twin core twisted flexible copper conductor cable with suitable size upto ceiling rose, complete all as specified and directed. Make: Havells Model No: LUMILINEBS20WLED840SPCWH or equivalent in Phillips/ CG / Bajaj. | 200 | Each | |
| 64 | 30 | M&L for Taking down ceiling fan of any description, sealing cable ends, dismantling blades, cleaning all dust, applying grease, filling cavaties with fillet, painting with synthetic enamel paint by spraying and writing MES No including reassembling blades and hanging ceiling fan and connecting up including provision of cable from ceiling rose to connector of fan, complete all as specified and directed. | 100 | Each Job | |
| 65 | 31 | All as per item No. 30 here-in-before but exhaust fans of any sweep. | 40 | Each | |
| 66 | 32 | All as per item No. 30 here-in-before but wall mounted fans/ Pedestal fans of any sweep. | 20 | Each | |
| 67 | 33 | Dismantling the unserviceable Gun metal bush supply and fix gun metal bush suitable for existing wall mounted/ pedestal/ exhasut fans, complete all as specified and directed. | 40 | Each | |
| 68 | 34 | Disconnect and remove unserviceable capacitor and Supply and fix in repair capacitor 2.5 MFD suitable for ceiling fan / exhaust fan, complete all as specified and directed. | 150 | Each | |
| 69 | 35 | All as per item No. 34 above but of 4 MFD suitable for ceiling fan / exhaust fan, complete all as specified and directed. | 35 | Each | |
| 70 | 36 | Dismantle the unserviceable shackle assembly comprising GI bolts, nuts, rubber bush and split pin, complete all as specified and directed. | 40 | Each | |
| 71 | 37 | M&L for removing the defective fan winding and rewinding with super enamelled copper wire of existing gauge, applying insulation varnish, pre heating and binding with empire tubes, crimple sheet etc, as required for rewinding, complete all as spedified and directed for the following:- Note: Cost of transportation/handling from MES Store to workshop & back is deemed to be included. | |||
| 72 | 37.01 | Ceiling fan of size upto 1400 mm sweep. | 80 | Each | |
| 73 | 37.02 | Wall mounted/ Pedestal fan of size upto 450 mm sweep. | 20 | Each | |
| 74 | 37.03 | Exhaust fan of size 350 to 450mm Sweep. | 20 | Each | |
| 75 | 37.04 | Exhaust fan of size upto 300 mm Sweep. | 50 | Each | |
| 76 | 38 | Taking down unserviceable louvers and supply and fix new louvers suitable for exhaust fans of size upto 450 mm sweep, complete all as specified and directed. | 5 | Each | |
| 77 | 39 | Taking down the electric Geyser of capacity 25 ltrs/ 50 ltrs carefully from its installed position by disconnecting inlet and outlet water pipes, electrical connections, dismantling the unit, painting with one coat of synthetic enamel paint and refixing in its original position and reconnecting the inlet/ outlet water pipes and testing on completion, complete all as specified and directed. | 25 | Each | |
| 78 | 40 | Supply and fixing of following items in repairs, suitable for single phase, 230 Volts, 50 Hz for existing type electric Geyser of capacity 25/50 Litres:- | |||
| 79 | 40.01 | Heating element 1500 watts push/ thread type porcelain / Circular / triangular type as required at site. | 25 | Each | |
| 80 | 40.02 | Thermostat as per the existing type. | 25 | Each | |
| 81 | 40.03 | Indication lamp red/ green. | 30 | Each | |
| 82 | 40.04 | Fusible plug | 20 | Each | |
| 83 | 41 | Taking down the electric geyser of capacity 25 Ltrs / 50 ltrs carefully from its installed position by disconnecting inlet and outlet water pipes, dismantling the unit, taking out the inner leaking copper shell, brazing the copper shell, testing for leaks, re-assembling the geyser including provision of additional glasswool as required, refixing in position, testing for functionality and commissioning, complete all as specified and directed. | 15 | Each | |
| 84 | 42 | Taking down unserviceable PVC connection of any description and supply and fix new PVC connection 15mm dia 450mm long with brass nuts, and rubber washers on both sides suitable for cold/ hot water, complete all as specified and directed. | 10 | Each | |
| 85 | 43 | M&L in repair for Vertical Distribution board when MCCB Triple Pole upto 250A is used for in coming and MCBs for out going to be used VTPN 8 way, 415 volts, IP 43, busbar, earth bar & neutral link double door, complete all as specified and directed. Note: MCCB and MCB will be measured and paid seperately under relevant items. | 2 | Each | |
| 86 | 44 | M&L in repair for Vertical Distribution board when MCCB Triple Pole upto 160A is used for in coming and MCBs for out going to be used VTPN 4 way, 415 volts, IP 43, busbar , earth bar & neutral link double door, complete all as specified and directed. Note: MCCB and MCB will be measured and paid seperately under relevant items. | 3 | Each | |
| 87 | 45 | Supply and fix in repair MCB Distribution board double door type (for incoming MCB & out going MCBs) TPN 8 way vertical type IP 43 with bus bar neutral link & earth bar etc, complete all as specified and directed. Note: MCB will be measured and paid seperately under relevant items. | 2 | Each | |
| 88 | 46 | Supply and fix in repair Distribution Board's when MCBs to be used 240V, double door of size neutral link & earth bar etc, complete all as specified and directed. Note: MCB will be measured and paid seperately under relevant items. | |||
| 89 | 46.01 | 4 way | 4 | Each | |
| 90 | 46.02 | 8 way | 5 | Each | |
| 91 | 46.03 | 12 way | 6 | Each | |
| 92 | 47 | All as per item No. 46 here-in-before but of TPN 4 way with incoming MCBs. | 10 | Each | |
| 93 | 48 | Supply and fix in repair Single pole & Neutral Metal clad enclosure with a two pin and earth plug and socket including one single pole MCB of 20 Amps, complete all as specified and directed. | 12 | Each | |
| 94 | 49 | Supply & fix in repairs, MCCB 3 pole, 415V, fixed type, 63 to 100 Amps suitable for Distribution Boards with terminating cables by using lugs as required, complete all as specified and directed. | |||
| 95 | 49.01 | MCCB TP 200A, 25KA. | 2 | Each | |
| 96 | 49.02 | MCCB TP 160A, 25KA. | 3 | Each | |
| 97 | 49.03 | MCCB TP 125A, 16KA. | 2 | Each | |
| 98 | 49.04 | MCCB TP 63A, 16KA. | 2 | Each | |
| 99 | 50 | Supply and Fix in repairs, MCB ''C'' curve, including provision of copper lugs for cable termination, terminating cables by using lugs as required, complete all as specified and directed. | |||
| 100 | 50.01 | MCB FP 63A, 10KA. | 10 | Each | |
| 101 | 50.02 | MCB FP 40A, 10KA. | 5 | Each | |
| 102 | 50.03 | MCB FP 32A, 10KA. | 5 | Each | |
| 103 | 50.04 | MCB DP 6-32A, 230 volts. | 9 | Each | |
| 104 | 50.05 | MCB DP 40A, 230 volts. | 6 | Each | |
| 105 | 50.06 | MCB SP 6-32A, 230 volts. | 200 | Each | |
| 106 | 51 | Taking down unsv flexible wire of any description and supply and connect flexible FR PVC Insulated (unsheathed) single core stranded copper conductor cable of 1100 voltage grade IS 694 of size 1.5 Sqmm, complete all as specified and directed. | 200 | RM | |
| 107 | 52 | Taking down exisiting service cable and supply and fixing 1100 volts gr. heavy duty cable, PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, twin core cable of size 6.0 Sqmm, complete all as specified and directed. | 200 | RM | |
| 108 | 53 | Taking down exisiting service cable and supply and fixing, 1100 volts gr. heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, twin core cable of size 10 Sqmm, complete all as specified and directed. | 100 | RM | |
| 109 | 54 | Taking down unserviceable multi-sensor (smoke & heat) and Analog addressable type multi-sensor (smoke & heat) detector with dual optic's technology to distinguish and differenciate between real fire, steam and dust to avoid any false alarm & built-in isolator with multiple algorithms setting with base powder, including other accessories as required complete all as specified and directed by Engineer-in-charge. Make: EST-3/Notifire/ Honey well/Ravel. | 4 | Each | |
| 110 | 55 | M&L in repair for earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 m below ground with top edge of the earth plate not less than 1.5 m below normal ground level, Earth plate shall be connected with double bolts, nuts, check nuts & washers & including 32x6 mm galvanized iron strip as earth lead, extended upto 7.5 m or upto test terminal point, drawn through 40mm dia med. gr. GI pipe for protection of galvanized iron strip in the ground, including excavation, earth work, Bentonite 25Kg, Charcoal & Salt all as specified, PCC chamber, RCC cover slab, watering pipe 20mm dia bore med. grade, funnel etc. & testing on completion all as specified in plate No.3 of SSR Part-I, complete all as specified and directed. Note: GI Pipe for protection of earthing strip and earth strip beyond 7.5m shall be measured and paid seperately under relevant items. | 15 | Each | |
| 111 | 56 | Taking down existing flourescent tube rod 36/40 watt and supply and fix new flourscent tube rod 36/40 watt. Make :- Bajaj/Philips/Cromption Greaves | 120 | Each | |
| 112 | 57 | Taking down existing unserviceable flourescent tube rod, 28 watt, T5 and supply and fix new flourscent tube rod, T5, 28 watt, complete all as specified and directed. | 30 | Each | |
| 113 | 58 | Supply and replacement of retrofit glass LED tube light, cool white, 20watt, suitable for T8 frame, including modification of wiring to suit LED tube and taking down old one, complete all as specified and directed. Make: Havells, Model: CRYSTAL1213T8DSTL20WLED865SGLASS 'OR' equivalent in Phillips/CG/ Instapower. | 200 | Each | |
| 114 | 59 | Supply and replacement of retrofit LED tube light, cool white, 10watt, suitable for T8 frame, including modification of wiring to suit LED tube and taking down old one, complete all as specified and directed. Make: Havells Cat No PHOTONULTRA603T8SSTL10WLED865SPC or equivalent in Phillips/ CG/ HPL/ Instapower. | 100 | Each | |
| 115 | 60 | Taking down the old unserviceable LED driver of any wattage from false ceiling and S & F LED Driver 42W suitable for 2'x2', recess mounted, 42W LED light fitting including making good to false ceiling as required, complete all as specified and directed. Make : Havells/Syska/CG/Philips/Bajaj | 10 | Each | |
| 116 | 61 | Taking down unserviceable Fire Alarm control panel and Supply, Installation, Testing and commissioning of New Addressable Fire Alarm control panel with power supply & battery back up at normal condition and 15 minutes alarm operation with battery charger etc. 2 Zone panel complete all as specified and directed by Engineer-in-charge. Make: EST-3/Notifire/ Honey well/Ravel. | 1 | Each | |
| 117 | 62 | Taking down of unserviceable building security lights of any type, Supply and fixing of energy efficient, 25W LED light fitting with die cast aluminium housing with high power LEDs as light source and complete accessories, fitted to existing pipe bracket complete all as specified and as directed. Make:Havells / Phillips/CG/Instapower/Bajaj. | 15 | Each | |
| 118 | 63 | Supply and replacing of tamper proof, digital energy meter of Accuracy Class 1.0, AC, 240V, 50Hz, with Backlit LCD Display, of rating 5-30A (Measures & Displays kWh,V,I,kW,PF, Last month history of kWh & MD in kW) with special features like TOD,Tamper logging,Optical Communication Port , including taking down the old meter, complete all as specified and directed. Make: L&T Model - WM101BC5DDH 'OR' equivalent in Secure, HPL, AE. | 15 | Each | |
| 119 | 64 | Supply and replacing of tamper proof AC Three Phase Static Energy meter of Accuracy Class 1.0, 3 x 240V, 50Hz, with Backlit LCD Display, of rating 10-60A (Measures & Displays kWh, V,I, kW, PF, Hz, Last month history of kWh & MD in kW) with special features like TOD,Tamper logging, Optical Communication Port , including taking down the old meter, complete all as specified and directed. Make: HPL, Model:TPPB1521130000ME01 (Gurgaon) 'OR' equivalent in Secure, L&T, AE. | 1 | Each | |
| 120 | 65 | Supply and replacing of TP, 3x240V, 50Hz, CT operated, digital Multi-function Energy meters of accuracy class 0.5 with backlit LCD display. Measures and displays trivector energy, load survey, TOD, Tamper detection & logging, power on / off events, instantaneous parameters of rating -/5A with transperant hinged type box, including taking down the old, complete all as specified and directed. Make: L&T 'OR' equivalent in Secure, HPL, AE. | 1 | Each | |
| 121 | 66 | Excavation of three holes of size 15cmx60cm depth sorrounding the existing earth pit, pouring of common salt (Sodium chloride) 5 Kgs in each hole, refilling the pit with the excavated soil and watering all as specified and as directed for increasing the earth conductivity and decreasing ER values, removing and clearing the surplus soil. | 25 | Each Job | |
| 122 | 67 | Supply and Fix in repair all in one solar street light 30W LED fitting IP66 colour temperature 6000-6500K, Inbuilt Lithium battery 3.2V 18AH, Inbuilt manocrystalline solar panel with features such as motion sensor and dusk to dawn operation suitable for fixing over existing poles. Make : LUKER/HAVELLS/SYSKA/BAJAJ or Any Equivalent | 4 | Each Job | |
| 123 | 68 | Servicing of solar geyser panel using mild cleaning agent, removing and replacing of rusted nuts and bolts with GI nuts and bolts. | 4 | Each | |
| 124 | 69 | Supply and replacement of geysor element, 3.0 KW, SP, suitable for Solar water heater backup including taking down the old element. | 4 | Each | |
| 125 | 70 | Supply and replacement of geysor element, 2.0 KW, SP, suitable for Solar water heater backup. including taking down the old element. | 2 | Each | |
| 126 | 71 | Disconnecting the electrical, water supply connections of Solar geyser, repairs to leaking Solar geyser inner tank by removing glass wool, cutting/disconnecting the rusted inlet and outlet nipples, supply and connect new nipples of size as existing by brazing/ welding, leak testing, refilling the glass wool including additional glasswool as required, fixing in position, testing and commissioning all as directed by Engineer-in-Charge. | 2 | Each | |
| 127 | 72 | Disconnecting the electrical, water supply connections of Solar geyser, Supply and replacement of E171, made of EN 304 SS steel sheet of thickness 0.8mm, suitable for flat plate collector along with with stand. | 1 | Each Job | |
| 128 | 73 | Disconnect and remove unserviceable electronic voltage stablizer of any description and supply and fix automatic electronic voltage stabilizer, wall mounting type having features such as Intelligent time Delay system, Low and High Voltage Cut-off Protection, latest IC Technology to protect from power fluctuations, Thermal over load protection, wide input variation between 170V to 270V with output voltage stablized at 220 to 240V, with accuracy of +/- 2.5% and of following capacity complete all as specified and directed. | |||
| 129 | 73.01 | 4 KVA Capacity. Make: V-Guard, Model-VG 400 or equivalent | 8 | Each | |
| 130 | 73.02 | 5 KVA Capacity. Make: V-Guard, Model-VG 500 or equivalent | 6 | Each |
AI Tender Summary
Tender Timeline
Nov 19, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedDec 10, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 12, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender