Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #26043151

Repair , Maintenance Of Internal Electrification System And Other Allied Works At Afs Begumpet Under Ge ( Af ) Hakimpet

Issued by Statutory Bodies & Commissions/Committees · BEGUMPET, Telangana
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Dec 2020
0 days left
EMD
49000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
BEGUMPET → Telangana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair , Maintenance Of Internal Electrification System And Other Allied Works At Afs Begumpet Under Ge ( Af ) Hakimpet

BOQ

NAME OF WORK :REPAIR, MAINTENANCE OF INTERNAL ELECTRIFICATION SYSTEM AND OTHER ALLIED WORKS AT AFS BEGUMPET UNDER GE(AF) HAKIMPET
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Taking down copper / aluminum point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, lamp holders, light fittings etc removing materials and making good disturbed surfaces of walls, floors etc, including paint tuch up to match with the existing surface as per site requirement, complete all as specified and directed.790Point
22M&L for Point wiring complete with 1.5 Sqmm single core PVC insulated FRLS cable, with multi standard copper conductors, 1100 volts grade, drawn thorough and including double locking type PVC casing and caping and its accessories of suitable size and including provisoin of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor, fabricated steel teminal box made out of 1.60 mm thick MS sheet concealed in walls and covered with 3 mm thick hylum sheet for fixing the switches /sockets/ regulators etc, complete all as specified and directed for the following:-
32.01One light point controlled by one one way switch.100Point
42.02One light point controlled by Two 2-way switch.12Point
52.03One ceiling fan/ exhaut fan point controlled by one one way switch.40Point
62.04One 3 pin socket outlet 5 Amps on the same board with other switches.40Point
72.05One 3 pin 5 Amps socket outlet the switch board of light point in the same vertical plane.40Point
82.06One 3 pin socket outlet 5 Amps on the Independent board.40Point
92.07One bell/ buzzer point controlled by one push button on the same board with other switches or independent.15Point
103All as per item No. 2 here-in-before but with 4.0 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor, complete all as specified and directed.\n25Point
114All as per item No. 2 here-in-before but conductor drawn through stove enamelled steel conduit (Surface) for one light point controlled by one flame proof switch complete all as specified and directed.4Point
125S&F Switch piano flush type, single pole one way 5 Amps 240 volts, complete all as specified and directed.280Each
136Supply and fix Switch Piano flush type two way 5 Amps, complete all as specified and directed.48Each
147Supply and fix Switch socket combination 2 in 1, 5 Amps flush type, complete all as specified and directed.245Each
158Supply and fix Switch socket combination, 3 pin, 5 and 15A, 5 IN 1 flush type, complete all as specified and directed.55Each
169Supply and fix Switch bell push 5 Amps flush type, complete all as specified and directed.30Each
1710S&F Stepped type electronic fan regulator flush type, complete all as specified and directed.64Each
1811S&F Ceiling rose PVC/ Polycorbonate insulated body with three terminals.364Each
1912S&F CMRI Certified LED Flameproof 2X16/20W LED Tube Light fixture and including LED tube-02 Nos recommended for gas / vapour group IP 65 Protection with complete fittings and accessories, complete all as specified and directed. Make : Crompton EXTN2LT8-16/20 or equivalent make of M/S Shyam Switchgears / M/S Sudhir / M/S Baliga as approved by GE.4Each
2013S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V. Make : M/S Shyam Switchgears / M/S Sudhir / M/S Baliga4Each
2114M&L for Point wiring complete with 1.5 sq mm single core PVC insulated FRLS cable, with multi standard copper conductors, 1100 volts grade, drawn thorough and including non metalic, medium grade rigid PVC conduit with all conduit accessories (including concealing and finising to match with the sorroundings) and including provisoin of 1.5 Sqmm PVC indulated copper cable FRLS as earth continiuty conductor, fabricated steel teminal box made out MS sheet suitable for Modular switches concealed in walls with front cover & base frame, screws, suitable for housing modular switches, socket outlets, fan regulators etc, all as specified and as directed for the following:-
2214.01One light point controlled by one way switch40Point
2314.02One ceiling fan/ exhaut fan point controlled by one way switch.20Point
2414.03One 3 pin socket outlet 5 Amps on the same board with other switches.20Point
2514.04One 3 pin 5 Amps socket outlet the switch board of light point ini the same vertical plane.20Point
2614.05One 3 pin socket outlet 5 Amps on the Independent board.20Point
2714.06One bell/ buzzer point controlled by one push button independent.12Point
2815All as per item No. 14 here-in-before but with 4 Sqmm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor, complete all as specified and directed.20Point
2916Supply and fix Modular switch 6A, 1 way, complete all as specified and directed.120Each
3017Supply and fix Modular switch 16A, 1 way, complete all as specified and directed.20Each
3118Supply and fix Socket outlet 6A modular, complete all as specified and directed.60Each
3219Supply and fix Socket outlet 16A modular, complete all as specified and directed.20Each
3320Supply and fix switch bell push modular, complete all as specified and directed.12Each
3421Supply and fix Fan Step regulator, 120 W-2 modular, complete all as specified and directed.20Each
3522Supply and fix bell, Ding Dong AC, 230 volts, SP, complete all as specified and directed.10Each
3623Taking down unserviceable sub main wiring of any description and M&L for sub main wiring with 2x4.0 Sq mm and 1x2.5 Sqmm (Earth), FRLS PVC insulated, unsheathed, multi-stranded, 1100 volts grade copper conductor calbe, single core, drawn through and including double locked type PVC casing & Capping and its all accessories of suitable size on wall/ roof surfaces, complete all as specified and directed. Note: Three runs 4/2.5 Sqmm copper cable and one run of suitable width of PVC casing and caping shall be measured as one unit length.120RM
3724Desrciption all as per item No. 23 here-in-before but with 2x6.0 Sqmm and 1x4 Sqmm (Earth), complete all as specified and directed. Note: Three runs 6/4 Sq mm copper cable and one run of suitable width of PVC casing and caping shall be measured as one unit length.90RM
3825Desrciption all as per item No. 23 here-in-before but with 4x6.0 Sqmm (3Ph+1N) + 2x 4 Sq mm (Earth), complete all as specified and directed. Note: Six runs 6/4 Sqmm copper cable and one run of suitable width of PVC casing and caping shall be measured as one unit length.60RM
3926Desrciption all as per item No. 23 here-in-before but with 4x10.0 Sqmm (3Ph+1N) + 2x 6 Sqmm (Earth), complete all as specified and directed. Note: Six runs 10/6 Sqmm copper cable and one run of suitable width of PVC casing and caping shall be measured as one unit length.30RM
4027Supply and fix in repairs including taking down the following Items:-
4127.01Electronic ballast suitable for 1x36/ 40 watts FTL. Make: Havells/Phillips, HPL, Crompton greaves.120Each
4227.02Electronic ballast suitable for 1x28 Watts (T-5) EEFTL. Make: Havells,Phillips, HPL, Crompton greaves.20Each
4327.03Starter 110V/220V suitable for 20/40 watt FTL. Make: HPL, phillips, Havells , crmpton greaves90Each
4427.04Lamp holder PVC/ Polycarbonate type with back plate suitable for batten/ angular type.50Each
4527.05Ceiling rose PVC/ Polycorbonate insulated body with three terminals.50Each
4627.06Switch Piano, flush type single pole, one way 5 Amps.80Each
4727.07Switch Piano flush type two way 5 Amps.20Each
4827.08Switch socket combination 2 in 1, 5 Amps flush type.60Each
4927.09Switch socket combination, 3 pin, 5 and 15A, 5 in 1 flush type.60Each
5027.1Switch bell push 5 Amps flush type.30Each
5127.11Stepped type electronic fan regulator flush type.50Each
5227.12Modular switch 6A, 1 way.60Each
5327.13Modular switch 16A, 1 way.40Each
5427.14Socket outlet 6A modular.50Each
5527.15Socket outlet 16A modular.40RM
5627.16Switch bell push modular.40Each
5727.17Fan Step regulator, 120 W-2 modular.50Each
5827.18Bell, Ding Dong AC, 230 volts, SP.30Each
5927.19Surface mounting PVC/Poly carbonate Box suitable for fixing 5A Switch socket over existing wall20Each
6027.2Surface mounting PVC/Poly carbonate Box suitable for fixing 15A Switch socket over existing wall10Each
6127.21Plug top polycarbonate 3 pin 5 Amps. Make : Legrand/Crabtreet/Anchor/Havells10Each
6228S&F Surface and wall mounted 9W LED 6K, 600X25x40 (LXWXH) batten, polycarbonate housing & integrated electronic driver ready to use pack etc. complete with all accessories internally pre-wired and fixing and connecting up with twin core twisted flexible copper conductor cable with suitable size upto ceiling rose, complete all as specified and directed. Make: Havells Model No: LUMILINEBS9WLED840SPCWH or equivalent in Phillips/ CG / Bajaj.100Each
6329S&F Surface and wall mounted 20W LED 6K, 1150X25x40 (LXWXH) batten, polycarbonate housing & integrated electronic driver ready to use pack etc. complete with all accessories internally pre-wired and fixing and connecting up with twin core twisted flexible copper conductor cable with suitable size upto ceiling rose, complete all as specified and directed. Make: Havells Model No: LUMILINEBS20WLED840SPCWH or equivalent in Phillips/ CG / Bajaj.200Each
6430M&L for Taking down ceiling fan of any description, sealing cable ends, dismantling blades, cleaning all dust, applying grease, filling cavaties with fillet, painting with synthetic enamel paint by spraying and writing MES No including reassembling blades and hanging ceiling fan and connecting up including provision of cable from ceiling rose to connector of fan, complete all as specified and directed.100Each Job
6531All as per item No. 30 here-in-before but exhaust fans of any sweep.40Each
6632All as per item No. 30 here-in-before but wall mounted fans/ Pedestal fans of any sweep.20Each
6733Dismantling the unserviceable Gun metal bush supply and fix gun metal bush suitable for existing wall mounted/ pedestal/ exhasut fans, complete all as specified and directed.40Each
6834Disconnect and remove unserviceable capacitor and Supply and fix in repair capacitor 2.5 MFD suitable for ceiling fan / exhaust fan, complete all as specified and directed.150Each
6935All as per item No. 34 above but of 4 MFD suitable for ceiling fan / exhaust fan, complete all as specified and directed.35Each
7036Dismantle the unserviceable shackle assembly comprising GI bolts, nuts, rubber bush and split pin, complete all as specified and directed.40Each
7137M&L for removing the defective fan winding and rewinding with super enamelled copper wire of existing gauge, applying insulation varnish, pre heating and binding with empire tubes, crimple sheet etc, as required for rewinding, complete all as spedified and directed for the following:- Note: Cost of transportation/handling from MES Store to workshop & back is deemed to be included.
7237.01Ceiling fan of size upto 1400 mm sweep.80Each
7337.02Wall mounted/ Pedestal fan of size upto 450 mm sweep.20Each
7437.03Exhaust fan of size 350 to 450mm Sweep.20Each
7537.04Exhaust fan of size upto 300 mm Sweep.50Each
7638Taking down unserviceable louvers and supply and fix new louvers suitable for exhaust fans of size upto 450 mm sweep, complete all as specified and directed.5Each
7739Taking down the electric Geyser of capacity 25 ltrs/ 50 ltrs carefully from its installed position by disconnecting inlet and outlet water pipes, electrical connections, dismantling the unit, painting with one coat of synthetic enamel paint and refixing in its original position and reconnecting the inlet/ outlet water pipes and testing on completion, complete all as specified and directed.25Each
7840Supply and fixing of following items in repairs, suitable for single phase, 230 Volts, 50 Hz for existing type electric Geyser of capacity 25/50 Litres:-
7940.01Heating element 1500 watts push/ thread type porcelain / Circular / triangular type as required at site.25Each
8040.02Thermostat as per the existing type.25Each
8140.03Indication lamp red/ green.30Each
8240.04Fusible plug20Each
8341Taking down the electric geyser of capacity 25 Ltrs / 50 ltrs carefully from its installed position by disconnecting inlet and outlet water pipes, dismantling the unit, taking out the inner leaking copper shell, brazing the copper shell, testing for leaks, re-assembling the geyser including provision of additional glasswool as required, refixing in position, testing for functionality and commissioning, complete all as specified and directed.15Each
8442Taking down unserviceable PVC connection of any description and supply and fix new PVC connection 15mm dia 450mm long with brass nuts, and rubber washers on both sides suitable for cold/ hot water, complete all as specified and directed.10Each
8543M&L in repair for Vertical Distribution board when MCCB Triple Pole upto 250A is used for in coming and MCBs for out going to be used VTPN 8 way, 415 volts, IP 43, busbar, earth bar & neutral link double door, complete all as specified and directed. Note: MCCB and MCB will be measured and paid seperately under relevant items.2Each
8644M&L in repair for Vertical Distribution board when MCCB Triple Pole upto 160A is used for in coming and MCBs for out going to be used VTPN 4 way, 415 volts, IP 43, busbar , earth bar & neutral link double door, complete all as specified and directed. Note: MCCB and MCB will be measured and paid seperately under relevant items.3Each
8745Supply and fix in repair MCB Distribution board double door type (for incoming MCB & out going MCBs) TPN 8 way vertical type IP 43 with bus bar neutral link & earth bar etc, complete all as specified and directed. Note: MCB will be measured and paid seperately under relevant items.2Each
8846Supply and fix in repair Distribution Board's when MCBs to be used 240V, double door of size neutral link & earth bar etc, complete all as specified and directed. Note: MCB will be measured and paid seperately under relevant items.
8946.014 way4Each
9046.028 way5Each
9146.0312 way6Each
9247All as per item No. 46 here-in-before but of TPN 4 way with incoming MCBs.10Each
9348Supply and fix in repair Single pole & Neutral Metal clad enclosure with a two pin and earth plug and socket including one single pole MCB of 20 Amps, complete all as specified and directed.12Each
9449Supply & fix in repairs, MCCB 3 pole, 415V, fixed type, 63 to 100 Amps suitable for Distribution Boards with terminating cables by using lugs as required, complete all as specified and directed.
9549.01MCCB TP 200A, 25KA.2Each
9649.02MCCB TP 160A, 25KA.3Each
9749.03MCCB TP 125A, 16KA.2Each
9849.04MCCB TP 63A, 16KA.2Each
9950Supply and Fix in repairs, MCB ''C'' curve, including provision of copper lugs for cable termination, terminating cables by using lugs as required, complete all as specified and directed.
10050.01MCB FP 63A, 10KA.10Each
10150.02MCB FP 40A, 10KA.5Each
10250.03MCB FP 32A, 10KA.5Each
10350.04MCB DP 6-32A, 230 volts.9Each
10450.05MCB DP 40A, 230 volts.6Each
10550.06MCB SP 6-32A, 230 volts.200Each
10651Taking down unsv flexible wire of any description and supply and connect flexible FR PVC Insulated (unsheathed) single core stranded copper conductor cable of 1100 voltage grade IS 694 of size 1.5 Sqmm, complete all as specified and directed.200RM
10752Taking down exisiting service cable and supply and fixing 1100 volts gr. heavy duty cable, PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, twin core cable of size 6.0 Sqmm, complete all as specified and directed.200RM
10853Taking down exisiting service cable and supply and fixing, 1100 volts gr. heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, twin core cable of size 10 Sqmm, complete all as specified and directed.100RM
10954Taking down unserviceable multi-sensor (smoke & heat) and Analog addressable type multi-sensor (smoke & heat) detector with dual optic's technology to distinguish and differenciate between real fire, steam and dust to avoid any false alarm & built-in isolator with multiple algorithms setting with base powder, including other accessories as required complete all as specified and directed by Engineer-in-charge. Make: EST-3/Notifire/ Honey well/Ravel.4Each
11055M&L in repair for earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 m below ground with top edge of the earth plate not less than 1.5 m below normal ground level, Earth plate shall be connected with double bolts, nuts, check nuts & washers & including 32x6 mm galvanized iron strip as earth lead, extended upto 7.5 m or upto test terminal point, drawn through 40mm dia med. gr. GI pipe for protection of galvanized iron strip in the ground, including excavation, earth work, Bentonite 25Kg, Charcoal & Salt all as specified, PCC chamber, RCC cover slab, watering pipe 20mm dia bore med. grade, funnel etc. & testing on completion all as specified in plate No.3 of SSR Part-I, complete all as specified and directed. Note: GI Pipe for protection of earthing strip and earth strip beyond 7.5m shall be measured and paid seperately under relevant items.15Each
11156Taking down existing flourescent tube rod 36/40 watt and supply and fix new flourscent tube rod 36/40 watt. Make :- Bajaj/Philips/Cromption Greaves120Each
11257Taking down existing unserviceable flourescent tube rod, 28 watt, T5 and supply and fix new flourscent tube rod, T5, 28 watt, complete all as specified and directed.30Each
11358Supply and replacement of retrofit glass LED tube light, cool white, 20watt, suitable for T8 frame, including modification of wiring to suit LED tube and taking down old one, complete all as specified and directed. Make: Havells, Model: CRYSTAL1213T8DSTL20WLED865SGLASS 'OR' equivalent in Phillips/CG/ Instapower.200Each
11459Supply and replacement of retrofit LED tube light, cool white, 10watt, suitable for T8 frame, including modification of wiring to suit LED tube and taking down old one, complete all as specified and directed. Make: Havells Cat No PHOTONULTRA603T8SSTL10WLED865SPC or equivalent in Phillips/ CG/ HPL/ Instapower.100Each
11560Taking down the old unserviceable LED driver of any wattage from false ceiling and S & F LED Driver 42W suitable for 2'x2', recess mounted, 42W LED light fitting including making good to false ceiling as required, complete all as specified and directed. Make : Havells/Syska/CG/Philips/Bajaj10Each
11661Taking down unserviceable Fire Alarm control panel and Supply, Installation, Testing and commissioning of New Addressable Fire Alarm control panel with power supply & battery back up at normal condition and 15 minutes alarm operation with battery charger etc. 2 Zone panel complete all as specified and directed by Engineer-in-charge. Make: EST-3/Notifire/ Honey well/Ravel.1Each
11762Taking down of unserviceable building security lights of any type, Supply and fixing of energy efficient, 25W LED light fitting with die cast aluminium housing with high power LEDs as light source and complete accessories, fitted to existing pipe bracket complete all as specified and as directed. Make:Havells / Phillips/CG/Instapower/Bajaj.15Each
11863Supply and replacing of tamper proof, digital energy meter of Accuracy Class 1.0, AC, 240V, 50Hz, with Backlit LCD Display, of rating 5-30A (Measures & Displays kWh,V,I,kW,PF, Last month history of kWh & MD in kW) with special features like TOD,Tamper logging,Optical Communication Port , including taking down the old meter, complete all as specified and directed. Make: L&T Model - WM101BC5DDH 'OR' equivalent in Secure, HPL, AE.15Each
11964Supply and replacing of tamper proof AC Three Phase Static Energy meter of Accuracy Class 1.0, 3 x 240V, 50Hz, with Backlit LCD Display, of rating 10-60A (Measures & Displays kWh, V,I, kW, PF, Hz, Last month history of kWh & MD in kW) with special features like TOD,Tamper logging, Optical Communication Port , including taking down the old meter, complete all as specified and directed. Make: HPL, Model:TPPB1521130000ME01 (Gurgaon) 'OR' equivalent in Secure, L&T, AE.1Each
12065Supply and replacing of TP, 3x240V, 50Hz, CT operated, digital Multi-function Energy meters of accuracy class 0.5 with backlit LCD display. Measures and displays trivector energy, load survey, TOD, Tamper detection & logging, power on / off events, instantaneous parameters of rating -/5A with transperant hinged type box, including taking down the old, complete all as specified and directed. Make: L&T 'OR' equivalent in Secure, HPL, AE.1Each
12166Excavation of three holes of size 15cmx60cm depth sorrounding the existing earth pit, pouring of common salt (Sodium chloride) 5 Kgs in each hole, refilling the pit with the excavated soil and watering all as specified and as directed for increasing the earth conductivity and decreasing ER values, removing and clearing the surplus soil.25Each Job
12267Supply and Fix in repair all in one solar street light 30W LED fitting IP66 colour temperature 6000-6500K, Inbuilt Lithium battery 3.2V 18AH, Inbuilt manocrystalline solar panel with features such as motion sensor and dusk to dawn operation suitable for fixing over existing poles. Make : LUKER/HAVELLS/SYSKA/BAJAJ or Any Equivalent4Each Job
12368Servicing of solar geyser panel using mild cleaning agent, removing and replacing of rusted nuts and bolts with GI nuts and bolts.4Each
12469Supply and replacement of geysor element, 3.0 KW, SP, suitable for Solar water heater backup including taking down the old element.4Each
12570Supply and replacement of geysor element, 2.0 KW, SP, suitable for Solar water heater backup. including taking down the old element.2Each
12671Disconnecting the electrical, water supply connections of Solar geyser, repairs to leaking Solar geyser inner tank by removing glass wool, cutting/disconnecting the rusted inlet and outlet nipples, supply and connect new nipples of size as existing by brazing/ welding, leak testing, refilling the glass wool including additional glasswool as required, fixing in position, testing and commissioning all as directed by Engineer-in-Charge.2Each
12772Disconnecting the electrical, water supply connections of Solar geyser, Supply and replacement of E171, made of EN 304 SS steel sheet of thickness 0.8mm, suitable for flat plate collector along with with stand.1Each Job
12873Disconnect and remove unserviceable electronic voltage stablizer of any description and supply and fix automatic electronic voltage stabilizer, wall mounting type having features such as Intelligent time Delay system, Low and High Voltage Cut-off Protection, latest IC Technology to protect from power fluctuations, Thermal over load protection, wide input variation between 170V to 270V with output voltage stablized at 220 to 240V, with accuracy of +/- 2.5% and of following capacity complete all as specified and directed.
12973.014 KVA Capacity. Make: V-Guard, Model-VG 400 or equivalent8Each
13073.025 KVA Capacity. Make: V-Guard, Model-VG 500 or equivalent6Each

AI Tender Summary

OUR REF NO 26043151
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 10-12-2020
Authority
Authority Name Military Engineer Services
Work Description Repair , Maintenance Of Internal Electrification System And Other Allied Works At Afs Begumpet Under Ge ( Af ) Hakimpet
Basic Detail
Tender No 8237/E8
Bidding Type Tender
Location
City BEGUMPET
State Telangana
Key Dates
Publish Date 19 Nov 2020
Submission Date 10 Dec 2020
Open Date 12 Dec 2020
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 49000
Exemption Not Available
Document List
8237Docs.pdf
6DF0309F-CAFE-4D7D-B4F4-7FC784CE559F.html
BOQ_442516.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 19, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 10, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 12, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

8237Docs.pdf

html

6DF0309F-CAFE-4D7D-B4F4-7FC784CE559F.html

xls

BOQ_442516.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders