Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #26023834

Proposed G Plus 5 Storied Residential Flat 20 Units For Professors At Gu Proposed G Plus 5 Storied Residential Flat 20 Units For Professors At Gu Civil Sanitary Water Supply Electrical Works And Installation Of Lift

Issued by Boards / Undertakings / PSU · Gauhati University, Assam
Tender Value
9.10 Crore
Estimated cost
Bid Submission
09 Dec 2020
0 days left
EMD
18.20 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gauhati University → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Proposed G Plus 5 Storied Residential Flat 20 Units For Professors At Gu Proposed G Plus 5 Storied Residential Flat 20 Units For Professors At Gu Civil Sanitary Water Supply Electrical Works And Installation Of Lift

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 01-Dec-2020 Pre Bid meeting will be held on 04.12.2020 at 2.00 PM Date 09-Dec-2020

BOQ

Name of Work: PROPOSED G+5 STORIED RESIDENTIAL FLAT (20 Units) FOR PROFESSORS AT GAUHATI UNIVERSITY (Civil, Sanitary & Water Supply, Electrical works and installation of Lift)
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11CIVIL WORKScc001
22EARTH WORK IN EXCAVATION\nEarthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\nA) Up to a depth of 2.00m below the existing ground level.\n(a) In ordinary soilcc0022158Cum
33B) Extra over item no.1.1(A) above for each 1m depth or part thereof beyond the initial depth of 2mcc003525.5Cum
44Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.\n(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.cc00423.5Cum
55PLAIN CEMENT CONCRETE WORKS\nPlain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete.\na)In prop 1cement: 3 sand :6 coarse aggregate by volumecc005126Cum
66b)In prop 1cement: 4 sand :8 coarse aggregate by volumecc0069.5Cum
77Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.cc00712Sqm
88REINFORCED CEMENT CONCRETE WORKS\nProviding and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) \n(I) Using Mixer Machine\n(A) In substructure up to plinth level\nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.\nN) Without using admixture, plasticiser\nb) M20 grade concrete or Prop 1:1.5:3cc008452Cum
99(B) In super structure from plinth level up to 1st floor level.\ni) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. \nN) Without using admixture, plasticiser\nb) M20 grade concrete or Prop 1:1.5:3cc00990.5Cum
1010ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.\nN) Without using admixture, plasticiser\nb) M20 grade concrete or Prop 1:1.5:3cc0101271Cum
1111Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level.cc0111158.5Cum
1212TIMBER SHUTTERING (FORMWORK)\nProviding form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nFoundation, footings, bases of columns, pile cap, raft and mass concrete works etc.\n(b) Using 25mm thick plankcc012227Sqm
1313Sides of tie beams, grade beams etc. at or below ground level.\n(b) Using 25mm thick plankcc013366Sqm
1414Columns, Pillars, Posts & Strut\nb) Circular or curved in plan (Using 38mm thick plank)cc014121Sqm
1515Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no. 3.1.1 & 3.1.3(b).cc015121Sqm
1616PLYBOARD SHUTTERING (FORMWORK)\nProviding form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:\nColumns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical facecc0162765.5Sqm
1717Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.\n(a) For depth not exceeding 1.0M.cc0172775.5Sqm
1818Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.\n(a) Floors etc. upto 200mm in thickness.cc0184239Sqm
1919Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.cc019864.5Sqm
2020Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.cc020239.5Sqm
2121Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no. 3.2.1 & 3.2.3(b).cc0218824.5Sqm
2222MASONARY WORK\nProviding soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a).Brick on flat soling.cc0221455Sqm
2323Filling sunken floor with broken jhama brick bats and sand including compacting and supplying of materials complete as specified and directed for all levels.cc02357Cum
2424Extra cost for lifting of brickbats and sand for filling of sunk floor for each subsequent floors above the ground floor as directed and specified.cc02457Cum
2525Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.\ni) In Sub-structure upto plinth level including dewatering if necessary\n(d) In proportion 1:6.cc0254.5Cum
2626ii) In Superstructure above plinth level up to 1st floor level.\n(b) In proportion 1:4.(1 cement:4 sand)cc02630.5Cum
2727Extra over item no. 4.1.4 above for brick work in each subsequent floor or part thereof above 1st floor level.cc02729Cum
28281st class brick wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level.\n(A) 112mm thick brick wall\n(a) In cement mortar in proportion 1:4. \n(1 cement:4 sand)cc0284594Sqm
2929Extra for brick walling for each subsequent floor or part thereof above the 1st floor level.\n(a) 112mm thick brick/ R.B wallcc0294409Sqm
3030FLOORING AND FLOOR FINISH\nTILES WORKS\nCERAMIC TILES\nB) ON WALLS\nProviding polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls).\nb) Executive range Somany/ Orient/Nitco/Asian Make\nii) Of size 250mmx350mm and abovecc030968Sqm
3131VITRIFIED TILES\nA) ON FLOOR\nProviding VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)\nb) Executive Range Somany / Orient /Varmora Make\ni) Of size 800mmx800mmcc0312903Sqm
3232CONCRETE TILES\n(A) FLOOR TILES\nProviding polished SUNROCK-Hi CTS/ MULTIWYN tiles of approved quality, size, shape and thickness not less than 18mm on floors and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department).\n(b) MULTIWYN TILES\nLegato, Ribbera, Matrix, Esquire, Enigma, Flora, Little Flora, Nirvana, Purl, Contoura, Cobble, Canaletta, Nexus, Koralcc032901Sqm
3333MARBLE FLOORING\n18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels.\n(i) Dungri Slabcc033171Sqm
3434GRANITE FLOORING\nProviding polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey /Sika /Pedelite /Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). \n(i) Normal Quality\n(ii) With White cementcc03489Sqm
3535ANTISKID TILES\nProviding Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.\n(A) CERAMIC \nii) Executive range-1 (Sizes 400 mm x 400mm and above)\n(a) Somany made- VC Shield (Group- 25) (406x406) mm Deluxe -VCcc035220Sqm
3636PLASTERING\nCEMENT PLASTERING\n10mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises , internal rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed.\nb) In cement mortar 1:4cc03615631.5Sqm
373715mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises , internal rounded angles, not exceeding 80mm in girth and finished even and smooth including curing complete as directed.\nA) On rough side\nb) In cement mortar 1:4cc0374726.5Sqm
3838Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.cc0384239Sqm
3939Extra over item no 6.2.1to 6.2.3 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed.\na) On Single coat plastercc03916410Sqm
4040Extra over item no. 6.2.1 to 6.2.3 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed.\na) On Single coat plastercc0403948Sqm
4141Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall for every addl floor or part thereof beyond 1st floor level including curing complete as directed.\na) On Single coat plastercc0413673Sqm
424215 mm thick plain cement mortar bands in cement mortar 1:4 in width including curing complete as directed.\nA) Up to 300 mm width\nc) Raised bandcc042125Sqm
4343POINTING\nPointing on brick work with cement mortar including curing complete as directed. (Measurement shall be taken on surface area of the wall).\nB) Cement mortar prop. 1:4\nb) Ruled pointingcc0433355Sqm
4444CELLING LINING AND PARTITION\nSupplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/ F suspended ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 5mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm thick Gypboard. (Contd.)cc044
4545False ceiling (Light Duty) with Moisture Resistant Board (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc., cut out made with frame of perimeter channel supported suitably to be measured and paid separately as and where necessary).\nii) 12.5mm MRBcc045303Sqm
4646ROOFING & ROOF TREATMENT\nProviding Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) Dyna roof / Wonder Roof /JSW Steel / Spectrum or equivalent as directed by the Departement\n(iii) 0.50 mm thickcc046556Sqm
4747Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. Dyna roof / Wonder Roof /JSW Steel / Spectrum or equivalent as directed by the Departement\n(iii) 0.50 mm thickcc047253Rm
4848WOOD WORKS\nProviding wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified - for Entrance Doors only\n(b) With 1st class timber (Bonsum/ Sundi)cc0481Cum
4949CUPBOARD SHUTTERS\nProviding and fixing 25mm thick wooden shutters for cup board including black enamelled M.S butt hinges (75mmx 40mmx1.12mm) 6 nos. with necessary wood screws (fully panelled) \n(ii) Using Particle / Block bord\ne).With block board (one side commercial and other side teak 12mm thick).cc049580Sqm
5050f).With block board (one side Teak and other side commercial 19mm/20mm thick).cc050850Sqm
5151Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. \na) Decorative type face panel and block board core - for Entrance Doors\n(ii) 35 mm thick .cc05151Sqm
5252b) Non decorative type and block board core.\n(ii) 35 mm thick .cc052294Sqm
5353Supply, fitting and fixing 30mm thick WPC door shutter in position including screws and hinges and other necessary fixtures (door fittings to be paid separately) - for Toiletscc05396Sqm
5454Supply, fitting and fixing WPC door frame of size 125mmx65mm including GI hold fast in position - for Toiletscc054300Rm
5555GRILL WORKS\nProviding, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.\nI . Plain grill\n(c) Fixed to Brickwork/P.C.C/R.C.C.cc0555226kg
5656ALUMINIUM WORKS\nProviding, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels.\na)Side hung and Top hung windows and ventilators\nii)5mm frosted glasscc05634Sqm
5757iv) 5 mm clear glasscc057118Sqm
5858b) Fixed windows and ventilators\ni) 6mm clear glasscc05833.5Sqm
5959Providing, fitting and fixing coloured anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars,joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.\na) 2 Track sliding window\ni) 6mm clear glasscc059270Sqm
6060PAINTING\nWALL PAINTING\nProviding two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)cc06019390Sqm
6161Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.\n(a). Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)cc06115442Sqm
6262Finishing old/ new wall with water proofing weather coat smooth anti-fungal premium textured exterior finish of Sandex Matt brand of Snowcem India Ltd. of required shade after clering and clearing the surfaces etc.including scaffolding complete as directed at all levels (two coats)cc0623948Sqm
6363PAINTING ON WOOD AND WOOD WOOD BASED SURFACES \nApplying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. \n(b). With ready mixed paint , wood primer (white).cc0631308Sqm
6464Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping\n(i). Surfaces over 100mm in width or girth.\na). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).cc0641308Sqm
6565PAINTING ON STEEL AND OTHER METAL SURFACE\nApplying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.\na). With ready mixed \"red-lead/ red oxide\" primer.cc065745Sqm
6666Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.\n(i).Surfaces over 100mm in width or girth.\na). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).cc066745Sqm
6767DOOR AND WINDOW FITTING\nBRASS FITTINGS\nSupplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ).\na) Sliding door bolts\nii) 250mm X 16mmcc067263Each
6868b) Tower bolts\niii) 250mm X 10mmcc068324Each
6969c) Door handles\ni) 75mmcc069400Each
7070iii) 150mmcc070324Each
7171o) Mortice cylindrical type (Godrej make)-polished Brasscc07180Each
7272q) Cupboard locks\ni) 40mmcc072240Each
7373t) Curtain rod\nii) 25mm x 2mmcc07356Rm
7474x) Magnet catchercc074400Each
7575DOOR CLOSER & FLOOR SPRING\nProviding,fitting and fixing Door closer of various type UL listed and fire rated good quality depending on the door specification.Types like single speed,Double Speed,Heavy Duty etc are available and as directed & specified by the department.\nA) Godrej\na) Single Speed Door Closer( size166.5x 48mmx 67mm)-Model C071cc07520Each
7676STEEL AND IRON WORKS\nREINFORCEMENT\nSupplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \na) From Primary Producer: TATA/SAIL/Jindal steel/Shyam steel/RINL\n(ii) Super Ductile (SD) TMT reiforcement barscc0762521Qtl
7777Extra over item 18.1.1 for each subsequent floor or part thereof above first floor level.cc0771610Qtl
7878Structural steel work in sigle sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint (up to 4.6m height) from plinth level including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. \na) In beams and joists fitted independently without connecting plates.cc0782Qtl
7979Steel work riveted and/ or bolted/ riveted in built up sections, frame work including cutting, hoisting, fixing in position and applying a priming coat of red- lead paint up to 4.6m height above plinth including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed.\nb) In single stanchions (columns) composed of R.S.J. or channels with caps, bases, splices, angle brackets etc.cc07919.5Qtl
8080ROOF TRUSS\nProviding, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. \nb) Using other ISI marked approved brand tubecc08098.5Qtl
8181DOOR FRAMES\nProviding, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately).\n(a) 1.25mm thick sheet\n(iii) Size 125mm x 60mm (Single rebate)cc081819Rm
8282STEEL RAILING\nProviding and fixing Stainless Steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer in charge. (For payment, only weight of stainless steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered).cc0828220kg
8383PLINTH PROTECTION WORKS\nProviding plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.cc083209Sqm
8484Providing drain with brick work in cement mortar in prop. 1:5 with half brick thick side walls and 100 mm thick CC(1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trances and refilling the sides after completion of work etc. as specified.\nii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.cc084174Rm
8585WATERPROOFING\nSURFACE PREPARATION\nPreparing the RCC surface in roof slab, chajjas, terraces, sunken slabs, septic tank, OH tank, raft slab, walls etc. by thoroughly cleaning with wire brush etc. followed by power washing for making the surface absolutely free from any foreign particles like dust, oil, grease etc. and allowing surface to dry complete as directed at all levels.cc085642Sqm
8686Applying 2 coats of 1mm thick acrylic polymer modified cementitious waterproofing coating Brushbond of Fosroc Chemicals/Dr. Sealkit Flexbond AP 121 C (Asian Chemicals)/ MASTERSEAL 550 of BASF for waterproofing structures like roof slabs, basement, sunken slabs, chajjas, tunnels, water tank etc. after proper surface preparation and soaking the surface with water prior to application complete as specified and directed by the Department at all levels.cc086642Sqm
8787ANTI-TERMITE TREATMENT\nPre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\na) With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water, i.e. 1% solution.cc087815Sqm
8888SEPTIC TANK (50 USERS CAPACITY) 4- NOs.: \nConstruction of Septic Tank including earthwork, PCC, RCC, Shuttering, brickwork, plastering and 2 nos of manhole cover as per approved specification and drawingscc0884Nos
8989SANITARY AND WATER SUPPLY WORKScc089
9090EUROPEAN TYPE WATER CLOSET\nProviding fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately)\nA) Parryware make\na) White\n(iii) Universal Closet P Trap (Cat No.C0272) (inclusive of seat cover)cc09060Each
9191PVC FLUSHING CISTERN\nSupplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)\nA) Parryware make\na) White\n(iii) Economy Dual Flush (Cat No.C8109)cc09160Each
9292WASH BASIN\nProviding vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)\nBasin (with pedestal)\nA) Parryware make\na) White\n(A) Parryware Make/(a) White/(iv) Cascade NXT 550 x 440 with long Pedestal (Cat. No.C0404/C0380)cc09260Each
9393KITCHEN SINK (STAINLESS STEEL)\nProviding fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately\n(B) Nirali\n(vi) Grace Deluxe Medium (Bowl Size - 445 x 368 x 190) Glossycc09320Each
9494MIRROR\nSupplying, fitting and fixing Decorative Mirror complete as directed and specified.\n(A) Parryware Make / (b) Size 600mm x 450mmcc09460Each
9595SHELF\nProviding fitting and fixing Glass Shelf complete as directed and specified.\nGlass shelf with C.P. guard rail \n(ii) Sona make (Cat. No.TR-0701)\n(a) 450mmcc09560Each
9696SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER\nSupplying, fitting and fixing CP soap tray / soap dish complete as directed and specified.\n(i) Jaquar Make/ (a) Continental (Cat. No. CAN-1331N)cc09660Each
9797TOWEL RAIL,TOWEL RACK & TOWEL RING\nProviding, fitting and fixing CP towel rail complete as directed and specified.\n(a) Jaquar make \n(iv) Queen's (450mm long) (Cat.No.AQN-7711A)cc09760Each
9898CHROME PLATED ROBE HOOK\nProviding, fitting and fixing Chrome Plated robe hook complete as directed and specified.\n(a) Jaquar make \n(ii) Queen's (Cat.No.AQN-7791)cc09860Each
9999TOILET PAPER HOLDER\nProviding, fitting and fixing Chrome Plated TOILET PAPER holder complete as directed and specified.\n(a) Jaquar make \n(ii) Continental toilet paper holder with flap (Cat.No. ACN-1153N)cc09960Each
100100Providing and fixing health faucet with 1.2 m PVC tube and swivel hook including all fittings complete.cc10060Each
101101AUTO AIR VENT\nProviding and fixing forged brass auto air vent valve 10 PN rating including all fitting & accessories.\na) 25 mm diacc1014Each
102102WASTE COUPLING\nProviding, fitting and fixing Chrome Plated waste coupling complete as directed and specified.\n(a) Jaquar make \n(i) 32mm (HT/FT) (Cat.No.ALD-705 / 709)cc10280Each
103103BOTTLE TRAP\nProviding, fitting and fixing Chrome Plated bottle trap complete as directed and specified.\n(a) Jaquar make \n(i) Bottle trap (with internal partition) 32mm size with 250mm long wall connection pipe (Cat.No. ALD-769)cc10380Each
104104PVC PIPES,BENDS,JUNCTIONS,TEES ETC.\nSupplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia.cc1041150Rm
105105(iv) 75mm dia.cc105460Rm
106106b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(ii) 110mm dia.cc106350Rm
107107(v) 63mm dia.cc10770Rm
108108(vi) 50mm dia.cc108330Rm
109109Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia.cc10960Each
110110(iv) 75 mm dia.cc11050Each
111111b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(ii) 110mm dia.cc11160Each
112112Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\na) In exposed surfaces or in trenches. \n(ii) 110mm dia.cc11260Each
113113(iv) 75 mm dia.cc11380Each
114114Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia.cc11440Each
115115b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(ii) 110mm dia.cc11530Each
116116Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia.cc11660Each
117117(iv) 75 mm dia.cc11780Each
118118b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(ii) 110mm dia.cc11860Each
119119(iv) 75mm dia.cc11980Each
120120Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia.cc12025Each
121121b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(ii) 110mm dia.cc12145Each
122122Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \nb) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(iv) 110 mm x 75mmcc12280Each
123123COWEL\nProviding fitting and fixing PVC cowel of ISI make complete as directed and specified.\n(iv) 75mm dia. PVC cowel of ISI makecc12312Each
124124GRATING\nProviding fiting & fixing C.I. Grating to the floors complete as directed and specified.\n(a) 110mm diacc12416Each
125125C.P. GRATING\nProviding fiting & fixing C.P. Grating to the floors complete as directed and specified.\n(ii) 110mm diacc125160Each
126126MANHOLE COVER\nProviding fitting and fixing (600x600)mm 90mm thick C.I. Man hole cover and frame of 25 Kg. weight complete as directed and specifiedcc12618Each
127127SOAK PIT AND INSPECTION CHAMBER\nConstruction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.cc12750Cum
128128Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.cc12822Each
129129PIPING\nProviding and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipe\n(A) Exposed or in trenches\nc) 25 mm nominal outer dia pipecc1291117Rm
130130d) 32 mm nominal outer dia pipecc13072Rm
131131e) 40 mm nominal outer dia pipecc13182Rm
132132(B) Concealed pipe with cutting chases & making good the walls\na) 15 mm nominal outer dia pipecc1321120Rm
133133b) 20 mm nominal outer dia pipecc133224Rm
134134c) 25 mm nominal outer dia pipecc134116Rm
135135BIB COCK\nSupplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) \nII) Jaquare make \n(a)Continental /Clarion\n(i)Standardcc13560Each
136136STOP COCK\nSupplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately)\n (I) Jaquar/ (a) Continental / Clarion/\n(ii) 15mm dia( Angular stop cock with long thread )cc136340Each
137137PILLAR COCK\nSupplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. \nII) Jaguar make\n(b) Long neck with areatorcc13760Each
138138SINK COCK\nSupplying fitting and fixing Chrome Plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid separately) \nI) Sona brand\nb) Sink cock J spoutcc13820Each
139139SHOWER\nSupplying fitting and fixing Chrome Plated (C.P.) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately)\nIII) Jaquar make\na) Continental/ (iii) Pressure adjustable shower with revolving jointcc13960Each
140140WALL MIXER\nSupplying, fitting and fixing Chrome Plated (C.P.) wall mixer complete as directed. \nV) Jaquar make \na). Continental / Clarion\niii) Wall mixer with telephonic shower arangment only Cat No.23267cc14060Each
141141VALVE\nSupplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed.\na) 50mm diacc1418Each
142142b) 40 mm dia.cc14264Each
143143c) 25 mm dia.cc14320Each
144144WATER TANK\nSupplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes\nI) 2000 Lt capacity\n(b) Polycon makecc14416Each
145145ELECTRICAL WORKScc145
146146SUB HEAD 1 : POINT WIRING , TV, TELEPHONE AND DATA\nWiring for light/ fan/ call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 2 mm thick 20mm dia rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including ceiling rose etc. complete.\nShort point up to 3.00 metre. Length.cc146355Each
147147Medium point up to 6.00 metre. Length.cc147510Each
148148Long point up to 10.00 metre. Length.cc14840Each
149149Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) cable in surface/ recessed PVC 2 mm thick rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.\nWith 3 x 1.5 sq. mm. cable in 20 mm dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit\ncc1492500Metre
150150Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 2 mm thick rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.\nWith 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit.cc150750Metre
151151Supplying with fitting and fixing of 120 watt electronic modular STEP speed control 2 - module type MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.\n120 watt electronic modular step speed control 2 - module typecc151140Each
152152Supplying with fitting fixing of 6 amp one way modular clip in bell push MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.cc15220Each
153153Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.cc153200Each
154154Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.cc154480Each
155155Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.cc155200Each
156156Supplying with fitting fixing of 6/10 amp two way modular clip in switch , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.cc156480Each
157157Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department.\n1-2 module type Metalcc157160Each
1581583 module type Metalcc158400Each
1591594 module type Metalcc15980Each
1601606 module type Metalcc160140Each
16116112 module type Metalcc16120Each
162162Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department.\n1 modulecc16280Each
1631632 modulecc16380Each
1641643 modulecc164400Each
1651654 modulecc16580Each
1661666 modulecc166140Each
16716712 modulecc16720Each
168168Supplying including fitting and fixing of TV SOCKET, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.cc16880Each
169169Supplying with fitting and fixing of RJ-11 Telephone jack , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.cc16980Each
170170Supplying ,installation, testing & commissioning of 2 pair Unarmoured Telephone Cable through existing conduit in surface/ recess system.cc1701600Metre
171171Wiring for Co - axial Jelly Flooded (Unarmoured) (FINOLEX /RR KABEL /NICCO / ANCHOR make) cable in existing surface conduit wiring system including connection etc as required.\nCo - axial Jelly Flooded (Unarmoured) RG 6 (Copper)cc1711200Metre
172172Supply and fixing of 25 mm dia 1.50mm to 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface system including painting etc as required:cc1721200Metre
173173Supply and fixing 32 mm mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface system including painting etc as required:cc173600Metre
174174Supply and fixing 25 mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in recessed system including cutting the wall and making good the same as required:cc174200Metre
175175Supply and fixing 32 mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in recessed system including cutting the wall and making good the same as required:cc17550Metre
176176Supplying ,installation, testing & commissioning of Distribution Box 20 pairs with Krones ( SIEMENS or equivalent as approved by the Deptt.)cc17660Each
177177Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 2 mm thick conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.\nWith 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.cc1771200Metre
178178SUB HEAD 2 : DISTRIBUTION BOARD \nSupplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof reversible Double door IP-43 double door surface mounting horizontal TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. \nABB, Schneider MG, legrand, Hager make)\n 8 way TPN (4+24) double doorcc17821Each
179179Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nC Series\n(Schneider MG, legrand, Hager make)\n6 to 32Acc179504Each
180180Supplying with fitting and fixing TPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nC Series (ABB, Schneider MG, legrand, Hager make)\n63Acc18021Each
181181Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\n100/300mA sensitivity DP RCCB\n(ABB, Schneider MG, legrand, Hager make)\n40Acc18163Each
182182Supplying fitting and fixing industrial Plug & Socket in surface mounting SPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of DP MCB complete with making necessary connection etc. as specified and directed by the Deptt. \n20A Capacity. (C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make)cc182200Each
183183SUB HEAD 3 : LT CABLE\nSupply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . \nCore - 3.5 A2XFY\n25 Sq.mm 3 and 1/2 core armoured cablecc18350Metre
184184120 Sq.mm 3 and 1/2 core armoured cablecc18420Metre
185185150 Sq.mm 3 and 1/2 core armoured cablecc185100Metre
186186SUPPLYING FITTING AND FIXING OF (DOWELLS/ COMET make) DOUBLE compression BRASS GLANDS WITH NICKEL - PLATED\nWEATHERPROOF (CBW) Size: 23.5 - 26, 1- 1/4 \"cc1862Each
187187WEATHERPROOF (CBW) Size: 41.5 - 46, 2 \"cc1872Each
188188WEATHERPROOF (CBW) Size: 46.5 - 52, 2 \"cc1882Each
189189RM30 AND RH50 RETURN FLANGE cable TRAY COVERS PRE GALVANIZED 19mm SIDE WALL HEIGHT WITH COVER FASTENER U NUT AND SCREW.\nSize of Tray Cover\n450cc18915Metre
190190Bend\n450cc1902Each
191191Tee\n450cc1911Each
192192SUB HEAD 4 : FLOOR BOARDS \nSupplying,unloading, storing, fixing in position, testing and commissioning the following sheet steel cubicle type panels fabricated from 1.6mm thick CRCA sheet, dead-front construction, dust and vermin proof, indoor type TPN Panels with hinged lockable doors fabricated from 2mm thick CRCA sheet, suitable for 415V, 3 phase 4 wire 50Hz AC supply with separate cable alley and lockable bus-bar chamber with tinned copper bus bar and including supplying and fixing following switchgears and accessories, inter-connections, bonding to earth, powder coated painting and marking as specified. Switch board complete as per schematic diagram:\nType of construction: Form 3\nIP classification: 42\nCable entries provisions shall be from the TOP and BOTTOM.\nThe BOQ shall be read in conjuction with general notes, specification and single line diagram (attached for ref.) In case of any disrepancy between specification, BOQ and SLD, the same shall be brought to the notice of Client/ Consultant before quoting the rates, otherwise stringent condition shall be deemed to have been considered. (Contd.)cc192
193193The internal control wiring shall be fuseless. All control wiring and metering protection shall be by MCB's. \nColour: Siemens Gray Powder Coated, as per approved sample.\nALL MCCBs Should have rotary operating handle & Door intelocked.\ninternal wiring of panel shall be with size 2.5sqmm flexible copper conductor for Cast Resin Type CT circuit and control wiring with 1.5sqmm.\nAll indicating light shall be LED type.\nThe contractor shall prepare proper GA drawings and shall seek approval for these from the project manager / electrical consultant prior to construction of all panels and boards.\nAll live accessible parts shall be shrouded with 3mm thick polycarbonate /FRP sheet and all equipment shall be finger touch proof .\nRemovable lifting hook shall be provided in all transportation section.\nAll bus bar shall be insulated with coloured PVC sleeve i.e. Red, Yellow, Blue and Black as per colour code.\nMAIN PANEL\nINCOMER\n1no. 250A, 25kA TP MCCB with accessible, isolatable neutral link, rotary operating handle with door interlock with thermal-magnetic release for O/L, S/C setting of 80%-100%, and ON /TRIP/ OFF indication.\n1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current with set of suitably sized Cast Resin Type CTs including protection with 2A SP MCB (Contd.)cc193
1941941 set of three phase indicating lamps with suitable protection. \nBusbar: Equally sized three phase and neutral Aluminium bus bars suitably sized to carry 315A current with colour coded heat shrinkable sleeves.\nOutgoings:\n2 Nos. 200A TPN MCCB of 16 KA breaking capacity, with heavy duty solid neutral link detachable along with ON indication lamp with 2A SP MCB for protection.\n4nos 63A TPN MCB (C Curve)\n1No. 25x6 mm Aluminium Earth Bus strip across the width of the Panel .\nMAIN PANEL, as described above shall be complete with all interconnections, risers, internal wiring, labels, terminal blocks etc. complete as required.\ncc1941Nos
195195LIFT PANEL\nINCOMER\n1 No. of 63 Amp FP MCCB of 16 KA Breaking capacity.\nMetering for incoming:\nDigital Multifunction meter (MFM-4) with RS-485 communication port for measurement of PF, V, A & Hz , equivalent to EM6459, with CT as required.\nPhase indicating lamps RYB with 2 Amps SP MCB back up.\nBus Bars:\nElectrolytic high conductivity aluminium three phase and neutral busbars rated at 100 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.3 sq.mm / amp.\nOutgoing (All MCB/MCCB shall be suitable for motor duty): \n3 Nos. 40A TP MPCB of 16 KA breaking capacity, with heavy duty solid neutral link detachable along with ON indication lamp with 2A SP MCB for protection & CBCT with Earth leakage relay.\n3 Nos. 40A TPN MCB of 10 KA breaking capacity\n1 Nos. 40A DP MCB of 10 KA breaking capacity\nLIFT PANEL, as described above shall be complete with all interconnections, risers, internal wiring, labels, terminal blocks etc. complete as required.cc1951Nos
196196METER BOARD\nINCOMER\n1 No. of 200 Amp FP MCCB of 16 KA Breaking capacity.\nMetering for incoming:\nDigital Multifunction meter (MFM-4) with RS-485 communication port for measurement of PF, V, A & Hz , equivalent to EM6459, with CT as required.\nPhase indicating lamps RYB with 2 Amps SP MCB back up.\nBus Bars:\nElectrolytic high conductivity aluminium three phase and neutral busbars rated at 250 Amps, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints. Current density of Bus Bar to be 1.3 sq.mm / amp.\nOutgoing (All MCB/MCCB shall be suitable for motor duty): \nCompartment housing for 21 Nos. Base mounted three phase Dual Energy Meter with all necessary control circuit and power wiring for dual metering, 21 Nos 63 A, 10 KA 4P MCB with MS sheet support for meter fixing, windows for meter reading including supply & fixing of MCB's & required wiring from bus bars to meter & meter to MCB's etc. KWHr meter will be supplied separately.\nMETER BOARD, as described above shall be complete with all interconnections, risers, internal wiring, labels, terminal blocks etc. complete as required.cc1961Nos
197197Digital Energy meter\nSupply, installation of Digital enrgy meter with 3-phase rating 10A-60A (L&T, HPL, Secure make)cc19721Nos
198198SUB HEAD 5 :CEILING FAN, EXHAUST FAN & CABIN FAN\nSupplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make)\nEnergy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent makecc198140Nos
199199Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.\nDomestic\nVentilator DX 250 mm sweep Louver type (ORIENT make), Brisk Air 250 mm sweep Louver type/ Trans Air 150 mm sweep (Crompton make), Ventil Air DX 150 mm sweep Louver type (Havells make)cc19980Each
200200SUB HEAD 6: LUMINARIES\nSupplying, installation, testing and commissioning of the following prewired CFL/ Flourescent/ LED luminaries complete with all accessories such as ballast, starter etc. directly on wall/ceilling including connection with 1.5 sq. mm PVC insulated single core copper conductor as required and directed by the Deptt.\nSupplying, fixing, testing and commissioning of Surface mounted luminaire for 20W LED Tube light with extruded thermal polycarbonate housing fixture should be of minimum 2000 lumens (6500 KELVIN) suitable for operation on 230 volt 50 Hz,Single Phase AC supply with electronic driver and all accessories complete for ceiling/wall/ Surface including wiring, connection with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable including earthing etc. as required. Similar to Wipro Make, Cat No: LL20-221-XXX-65AL1 or equivalent preferred make.cc200180Each
2012018W Round shape LED Downlighter suitable for operation on 230V AC supply with minimum 850lumens. LED make shall be Nichia, Cree, Citizen having LM 80 Complied as per L70 standard tested for min. 10k hours confirming minimum 50000 burning hours of life 6500K LED's only. LED Driver shall withstand 2kV surge protection. Complete fitting similar to Wipro make CAT NO. LD90-231-XXX-65XX or equivalent preferred make.cc20160Each
2022026W Round shape LED Downlighter suitable for operation on 230V AC supply with minimum 630 lumens. LED make shall be Nichia, Cree, Citizen having LM 80 Complied as per L70 standard tested for min. 10k hours confirming minimum 50000 burning hours of life 6500K LED's only. LED Driver shall withstand 2kV surge protection. Complete fitting similar to Wipro make CAT NO. LD90-111-XXX-65XX or equivalent preferred make.cc202215Each
203203Supplying, fixing, testing and commissioning of Mirror Light 8W LED min 350 lumens, 1 feet length, 6500 K complete with electronic driver, lockable holders and LED lamp including connection etc. as required similar to Wipro cat no. LL20-111-XXX-65NE3 or or equivalent preferred make.cc20360Each
20420430W, Wall mounted LED Flood light fixture, cool white color temperature K.Lite Cat no. BUMBLEBEE 7071.or approved equivalent..cc2048Each
205205Supply, installation, testing & commissioning of 7-12W wall mounted bracket light provided with E27 Bulb Holder IP20 , Optics: White PC Diffuser with CR Body.cc205120Each
206206Supply, installation, testing & commissioning of 4ft Linear LED luminaire delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy = 100 lm / W. The luminaire Housing shall be made of PC & the diffuser shall be of polycarbonate/PMMA. The operating CCT shall be 6500K with CRI of =80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD = 20% & PF = 0.95 , 50,000 Hrs LED Life with L70 Criteria, IP20. The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.cc20682Each
207207SUB HEAD 7 : EARTHING \nSupply, installation & testing of G.I. Plate earth station with 600 mmx600 mmx6 mm heavy duty G.I. earth plate with necessary 40 mm dia. G.I. watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm hinged cover C.I. cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .cc20710Each
208208Supplying & laying of 8 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.cc20850Metre
209209Supplying & laying of 8 SWG G.I.. earth drawn through 15 mm dia. Medium quality G.I. pipe from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.cc20950Metre
210210Supplying & laying of 25X6 size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.cc21060Metre
211211Supplying & laying of 50X6 size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.cc21120Metre
212212Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt.cc212200Metre
213213Supply and drawing of earth continuity with 1.50 SQ mm single core flame retardant low smoke PVC insulated multistrand twisted copper cable (Green colour in the existing PVC conduits including making necessary connection as approved, specified and directed by the deptt.cc21350Each
214214ANCILLARY (FENCING, GATE & PAVING) WORKScc214
215215EARTH WORK IN EXCAVATION\nEarthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\nA) Up to a depth of 2.00m below the existing ground level.\n(a) In ordinary soilcc21518Cum
216216PLAIN CEMENT CONCRETE WORKS\nPlain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete.\na)In prop 1cement: 3 sand :6 coarse aggregate by volumecc2164.5Cum
217217REINFORCED CEMENT CONCRETE WORKS\nProviding and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) \n(I) Using Mixer Machine\n(A) In substructure up to plinth level\nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.\nN) Without using admixture, plasticiser\nb) M20 grade concrete or Prop 1:1.5:3cc2171.1Cum
218218(B) In super structure from plinth level up to 1st floor level. \nII) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.\nN) Without using admixture, plasticiser\nb) M20 grade concrete or Prop 1:1.5:3cc2180.4Cum
219219TIMBER SHUTTERING (FORMWORK)\nProviding form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nFoundation, footings, bases of columns, pile cap, raft and mass concrete works etc.\n(b) Using 25mm thick plankcc21976Sqm
220220Sides of tie beams, grade beams etc. at or below ground level.\n(b) Using 25mm thick plankcc2202.6Sqm
221221Columns, Pillars, Posts & Strut\n(a) Square, Rectangular, Polygonal in plan or any shape like Tee/L etc. having plane vertical face\n(ii) Using 25mm thick plankcc2216.5Sqm
222222MASONARY WORK\nProviding soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a).Brick on flat soling.cc22223.5Sqm
223223PAVERS\nProviding SUN ROCK HIGH CTS/ DEVI paver block/ tiles of concrete grade M30 or above of approved quality, size, shape of specified thickness over a leveling bedding layer of 30mm compacted sand over a base of WBM or PCC (Base course to be paid separately) including cutting where necessary finished with spreading, sweeping, jointing sand and compacting the pavers using vibrating compactors as specified and directed.\nSUN ROCK HIGH CTS/ Devi Tiles (Pavers)\n(b) 60mm thickcc2231162Sqm
224224DEVI Tiles (Pavers)\ni) Of size 300x300mm of 25 thickcc224101Sqm
225225GRANULAR SUB-BASE with close graded material (Table : 400-1)\nB). By Mix in Place Method (Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density,complete as per cl. 401( Including cost of testing of materials at site and laboratory as directed by the deptt.)\n(i) For Grading-I Materialcc225190Cum
226226WATER BOUND MACADAM\nProviding, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density ( with an initial lead of 5.0 km.)\nB. By Mechanical Means\nI) Grading- I\n(a) Using Screening Crushable type such as Moorum or Gravel.cc22695Cum
227227PLASTERING\nCEMENT PLASTERING\n15mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises , internal rounded angles, not exceeding 80mm in girth and finished even and smooth including curing complete as directed.\nA) On rough side\nb) In cement mortar 1:4cc2274.5Sqm
228228PAINTING\nWALL PAINTING\nProviding two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)cc2284.5Sqm
229229Finishing old/ new wall with water proofing weather coat smooth anti-fungal premium textured exterior finish of Sandex Matt brand of Snowcem India Ltd. of required shade after clering and clearing the surfaces etc.including scaffolding complete as directed at all levels (two coats)cc2294.5Sqm
230230PAINTING ON STEEL AND OTHER METAL SURFACE\nApplying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.\na). With ready mixed \"red-lead/ red oxide\" primer.cc2308Sqm
231231Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.\n(i).Surfaces over 100mm in width or girth.\na). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).cc2318Sqm
232232STEEL AND IRON WORKS\nREINFORCEMENT\nSupplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \na) From Primary Producer: TATA/SAIL/Jindal steel/Shyam steel/RINL\n(i) TMT Corrosion resistant steel (CRS) reiforcement barcc2321.1Qtl
233233FENCING & GATES\nSupplying, fitting and fixing chain link fencing of 10 S.W.G, G.I. Wire 50mm x50mm mesh fitted to M.S angle iron post at 2000mm apart of specification detailed below including supplying, fitting and fixing hooks, eye bolts with nuts, staples and bolts including three horizontal lines of G.I wire 10 S.W.G at top,middle and bottom and with one vertical line to each fencing post for keeping the fencing tight and erect complete, including one coat of primer painting to M.S angle iron post in P.C.C base etc. with following.\na) Corner and end posts with M.S angle of size 50mmx50mmx 5mm and length not less than 1800mm only duly slotted and bottom torqued with two numbers as stay posts\nb). Intermediate post with M.S angle of size 40mmx40mmx5mm and length not less than 1800mm only duly slotted and bottom torqued and splayed.\nc).Stay post with M.S angle of size 35 mmx35mmx5mm and length not less than 1800mm duly slotted and bottom torqued and splayed. All M.S angle iron posts are to be fitted to P.C.C base embedded not less than 600mm (P.C.C. work shall be measured and paid separately).cc233372Sqm
234234Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 40mm x 40mm x 6mm M.S. angle and with M.S. flat of 40mm x 6mm size as per approved design.Necessary locking arrangement for temporary closing the gate and 2nos.( minimum) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embedded in C.C brick pillers as necessary including a red oxide painting to all iron works as directed and specified.(Separate payment will be made for posts).cc2342.5Qtl
235235Providing rails for plying of rollers of gate made made from 50mm x 6mm size M.S. flat and to be fitted with 3 nos of hinged hold fasts to be embedded in concrete prop. 1:2:4 of 10mm wide and 75 mm deep over brick flat soling 250mm wide including curing etc. complete.cc23515M
236236Providing roller to the gate including welding etc.complete\nb) With 12.50mmx50mm (dia) rollercc2362Each
237237LIFTcc237
238238Supplying installation, testing and commissioning of Passenger Elevator for 6 stop(544 K 8 persons) having contract speed of 0.65 Metre/Sec(approx.)mps serving different floor in the existing lift shaft as per detailed specification enclosed and as under\nLocation of the lift-\n1.Type & Capacity-Passenger-08 Persons-544Kg.\n2.Speed- 0.65 Metre./Sec (approx.)\n3.Type of Drive- Variable Voltage Variable Frequency Drive with Microprocessor based Simplex Full Collective Control.\n4. Location of Machine Room- Top\n5. Available Travel- 15.5 metres. ( Maximum)\n6. Serving- Ground Floor to 5th Floor (0,1,2,3,4,5) 6 Stops 6 Levels 6 Openings \n7. Well Size- 1850 mm WideX 1850 mm Deep over the finished surface \n8. Power supply- 415 Volts 3 phase, 50 cycles alternating current\n10. Auxiliary Required- Single-phase 220 V 50 Cycles alternating current. (Contd.)cc238
23923911. Cab size (Clear Inside approx.---1300mm wideX1100 mm Deep.\n12. Pit Depth--1600 mm\n13. Head Room-4800 mm.\n14. Car Enclosure- Stainless Steel Car- Hairline Finish.\n15. Flooring- PVC Flooring\n16. Electric Light- Fluorescent Light Fittings \n17. Fan- 300 mm Sweep one number. \n18. No of Entrances- One Location - Front. \n19. Car Entrance- Centre Opening Stainless Steel Power Door without vision panel. (Contd.)cc239
24024020. Landing Entrance- Centre Opening Stainless Steel Power Door without vision panel. \n21. Clear Opening- 800 mm Wide X 2000 mm High. \n22. Indicators-Car & Landings-Direction & Position Indicator.\nOther Features --Emergency Alarm & Light.\nCall Registration LEDS .\nOSG Electronic Switch.\nFireman Drive\n Intercom.\n Full Length Infra Red door Safety. Auto\nRescue Device.\nNote: i. Rate should include the cost for obtaining lift operating license from the competent authority and rectification of technical defects as pointed out during the inspection by licensing authoruty\nii. Approved Brand/Manufactures-All the lift Manufactures as approved under category-A of CPWD works manual.cc2402Nos
241241Supply (fitting), installation testing and commissioning of 15 KVA Servo Controlled Automatic Voltage Stabilizer of Rating input voltage 280 to 460 and 3-Ph, 50 Hz, AC and output voltage 415 V+/-, 4 wire 50 cycles including grouting, making connection with cable, termination testing etc as required complete and as directed by the Dept. Rating: 15KVA, Type of cooling : Air , suitable for Lift application up to 5.5 KW Motor Rating with built in under voltage, over voltage & over Load protection Circuitry on the output side with suitable Contractor for tripping (Make: Automatic Electric or equivalent as approved and directed by the Deptt.)cc2412Nos

AI Tender Summary

OUR REF NO 26023834
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 9.10 Crore
LAST DATE 09-12-2020
Authority
Authority Name University Gauhati University
Work Description Proposed G Plus 5 Storied Residential Flat 20 Units For Professors At Gu Proposed G Plus 5 Storied Residential Flat 20 Units For Professors At Gu Civil Sanitary Water Supply Electrical Works And Installation Of Lift
Basic Detail
Tender No T/20-21/89 dated 13.11.2020
Bidding Type Tender
Location
City Gauhati University
State Assam
Key Dates
Publish Date 01 Dec 2020
Submission Date 09 Dec 2020
Open Date 10 Dec 2020
Finance
Tender Value 9.10 Crore
Tender Fee 20000
EMD 18.20 Lakhs
Exemption Not Available
Document List
AB7F16AF-5119-49DD-A5B9-F1A5C45DF3D5.html
NITteachersflat.pdf
BOQ_29959.xls
Tendernotice_1.pdf
FormOfBid.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 01, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 09, 2020
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 09, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 10, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

AB7F16AF-5119-49DD-A5B9-F1A5C45DF3D5.html

pdf

NITteachersflat.pdf

xls

BOQ_29959.xls

pdf

Tendernotice_1.pdf

pdf

FormOfBid.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders