Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #26011962

Construction And Commissioning Of 200 Mm Diameter Tubewell With Pipe Line At Rwss Tehla P . S . Rajgarh

Issued by Government Departments · Tehla, Rajasthan
Tender Value
25.20 Lakhs
Estimated cost
Bid Submission
01 Dec 2020
0 days left
EMD
25200
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tehla → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction And Commissioning Of 200 Mm Diameter Tubewell With Pipe Line At Rwss Tehla P . S . Rajgarh

BOQ

Name of Work: Construction & Commissioning of 200 mm diameter Tubewells & P/L/J/T/C of pipe line at RWSS Tehla P.S. Rajgarh.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications, with gravel as per IS:4097-1967 and it's packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & it's primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water.BI01010001010000000000000515BI0100001112
21.1Nominal bore 200 mm dia.BI01010001010000000000000515BI0100001113190Mtr
32Construction of tube well after completion of drilling by rotary method & upto 150 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe.BI01010001010000000000000515BI0100001114
42.1Nominal bore 200 mm dia.BI01010001010000000000000515BI0100001115410Mtr
52.2Add 15% extra on depth more than 150 mtr for drilling beyond 150 mtr depth from ground level.BI01010001010000000000000515BI0100001116300Mtr
63Labour charges for making slots on blank pipes made of ERW MS black pipe of following sizes, the slotting should be as per IS:8110-2000 or as amended up to date.BI01010001010000000000000515BI0100001117
73.1200 mm dia nominal bore.BI01010001010000000000000515BI010000111836Mtr
84Development of tube well as per IS: 11189- 1985 and IS: 2800 (Part- I)- 1991 (both amended up to date) using suitable compressor to give sand free water for required yield of the gravel packed tube well.BI01010001010000000000000515BI010000111910Hr.
95Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.BI01010001010000000000000515BI0100001120
105.1200 mm diaBI01010001010000000000000515BI01000011212Each
116Supply & Installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.BI01010001010000000000000515BI0100001122
126.19.3 KW (12.5 HP) & head above 120 mtr.BI01010001010000000000000515BI010000112337.2KW
137Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.BI01010001010000000000000515BI0100001124
147.13 core 6.0 Sq.mmBI01010001010000000000000515BI0100001125700Mtr
158Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.BI01010001010000000000000515BI0100001126
168.116.0 Sq.mm, 4 coreBI01010001010000000000000515BI010000112760Mtr
179Providing & Lowering in tubewell ISI marked GI Pipe “B\" (medium) class as per IS:1239 part I 2004 or amended up to date, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.BI01010001010000000000000515BI0100001128
189.150 mm diaBI01010001010000000000000515BI0100001129320Mtr
1910Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set.BI01010001010000000000000515BI01000011304Each
2011Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizesBI01010001010000000000000515BI0100001131
2111.180 mm diaBI01010001010000000000000515BI01000011322Each
2212Supply and installing Double flanged Sluice valves as per IS :14846 of 80mm diameter with cap and giving Satisfactory test complete and or so directed by Engineer . It also include cost of labour , jointing material with nuts & bolt and Rubber sheet.BI01010001010000000000000515BI01000011332Each
2313Providing & Lowering in tubewell ISI marked GI Pipe “B\" (medium) class as per IS:1239 part I 2004 or amended up to date, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.BI01010001010000000000000515BI0100001134
2413.180mm diaBI01010001010000000000000515BI010000113510Mtr
2514Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover.BI01010001010000000000000515BI01000011362Each
2615Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.BI01010001010000000000000515BI0100001137
2715.180 mm diaBI01010001010000000000000515BI01000011382Each
2816Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form.The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for 440 Volt AC Supply.BI01010001010000000000000515BI0100001139
2916.1Above 10 HP and up to 15 HPBI01010001010000000000000515BI01000011402Each
3017Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. \nBI01010001010000000000000515BI01000011412Each
3118Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge.BI01010001010000000000000515BI01000011422Each
3219Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizesBI01010001010000000000000515BI0100001143
3319.1200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)BI01010001010000000000000515BI0100001144192Mtr
3420Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) \nNote : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.\nSupply up to 110 mm dia. in coil & above 110 mm dia straight length in 6 M.BI01010001010000000000000515BI0100001145
3520.1HDPE PE-80 PN-06BI01010001010000000000000515BI0100001146
3620.290 mm diaBI01010001010000000000000515BI0100001147600RM
3720.3HDPE PE-80 PN-10BI01010001010000000000000515BI0100001148
3820.4110 mm diaBI01010001010000000000000515BI0100001149800RM
3921Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soilsBI01010001010000000000000515BI0100001150945CUM
4022Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. \n1: 3: 6 or richer mix.BI01010001010000000000000515BI010000115125.3CUM
4123Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.BI01010001010000000000000515BI0100001152
4223.1M20 grade Nominal Mix \n1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate \n20 mm nominal size).BI01010001010000000000000515BI010000115325.3CUM
4324Providing, lowering, laying, aligning, fixing in position in pipe line, manually operated CI D/F Sluice valves of approved make (IS:14846 amended upto date) PN 1.0 class of following dia complete (including jointing and jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer.\nCategory \"A\" \" Make: (Kirloskar Bros. Ltd., Indian Valve Co. (IVC), Fouress Engineers Pvt. Ltd.)BI01010001010000000000000515BI0100001154
4424.1100 mm diaBI01010001010000000000000515BI01000011551Each
4525Providing, lowering, laying, aligning, fixing in position and jointing in pipe line, CI screwed Air valves class PN-1.0 single ball of approved make, including screw down isolation valve of following dia including cost of all labour, jointing material i.e. bolts, nuts, rubber insertions etc. complete including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.BI01010001010000000000000515BI0100001156
4625.150 mm dia screwed end.BI01010001010000000000000515BI01000011571Each

AI Tender Summary

OUR REF NO 26011962
AUTHORITY Government Departments
TENDER VALUE 25.20 Lakhs
LAST DATE 01-12-2020
Authority
Authority Name Public Health And Engineering Department
Work Description Construction And Commissioning Of 200 Mm Diameter Tubewell With Pipe Line At Rwss Tehla P . S . Rajgarh
Basic Detail
Tender No 58/2020-21
Bidding Type Tender
Location
City Tehla
State Rajasthan
Key Dates
Publish Date 17 Nov 2020
Submission Date 01 Dec 2020
Open Date 02 Dec 2020
Finance
Tender Value 25.20 Lakhs
Tender Fee 2000
EMD 25200
Exemption Not Available
Document List
0C39C6E6-0235-44F4-A4DC-0C13DB566385.html
Tendernotice_1.pdf
BOQ_367140.xls
TD_58_Tehla.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 17, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 01, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 02, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

0C39C6E6-0235-44F4-A4DC-0C13DB566385.html

pdf

Tendernotice_1.pdf

xls

BOQ_367140.xls

pdf

TD_58_Tehla.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail