Water Resources and Irrigation Government Departments Closing in 0 days TDR #26006727

Installation And Energisation Of Mahaling Vi Of New Lift Irrigation Project Under Golamunda Block In Kalahandi District Construction Of Head Works , Distribution System And Energisation Including Power Supply Work

Issued by Government Departments · GOLAMUNDA, Odisha
Tender Value
Ref. Documents
Estimated cost
Bid Submission
26 Nov 2020
0 days left
EMD
24755
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
GOLAMUNDA → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Installation And Energisation Of Mahaling Vi Of New Lift Irrigation Project Under Golamunda Block In Kalahandi District Construction Of Head Works , Distribution System And Energisation Including Power Supply Work

BOQ

Name of Work: INSTALLATION AND ENERGISATION OF MAHALING-VI OF NEW LIFT IRRIGATION PROJECT UNDER GOLAMUNDA BLOCK IN KALAHANDI DISTRICT
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Earthwork in excavation of foundation in hard soil including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-incharge.1802.13CUM
22Filling the foundation and plinth with excavated material as directed by the Engineer-incharge.1794.39CUM
33Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge.74.49CUM
44Cement concrete (1:4:8) with 4cm size h.g.b. hand broken metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. complete as per the direction of the Engineer-incharge.6.99CUM
55Cement concrete (1:2:4) with 12mm size black C.B. hand broken chips of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc complete as per the direction of the Engineer-incharge.1.55CUM
66R.C.C. work in C.C. (1:2:4) including hoisting & laying & curring for 28 days using 12mm. Size clean black hard granite crusher broken chips of approve quality and from approve quarry including cost taxes conveyance charges of all materials to the worksite with supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.16.43CUM
77Brick work with Fly Ash Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge.4.71CUM
8812mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.28.86SQM
99Cement punning over plastering including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.7.35SQM
1010Rigid smooth centering & shuttering for R.C.C. Works walls & fins including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-incharge.252.74CUM
111125mm thick A.S. flooring with C.C. (1:2:4) using 12mm size black hard granite crusher broken chips of approve quality for approve quorry including water and curring with cost taxes royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.0.49SQM
1212Labour charge for M.S. reinforcement for R.C.C. work including cutting, bending & typing the grills & placing in position including cost of binding wire 18 to 20 guage per Qntl. Including cost of HYSD Steel Bar (FE 415/ FE 500)12.87Qntl
1313Painting of enamel paint of approved quality and colour for painting over iron work including cost taxes etc. complete as per the direction of the Engineer-incharge.1SQM
1414White washing 2 coat with approve good stone lime including cost conveyance charges of materials including supply of labour, gum, indigo etc. required for the work complete as directed by the Engineer-incharge.103.24SQM
1515MS Pannel Door double leaf with MS frame overall size including frame of height 1.2mt x 1.98 mt. Door & Window of size 1.2 Mtr X 0.9 Mtr with shutter of 20 gauge CR sheet pannel as per approved size & specification etc. complete including cost of all materials fitting and fixing the door etc. complete as per the direction of the Engineer-incharge.1SQM
1616Cost of outlet20NO
17175/8 ' x12\" Nut bolt & washer F.T. for foundation5KG
18185/8 ' x3\" Nut bolt F.T. as per IS specification5KG
19191/2\" x2 1/2\" Nut bolt F.T.as per IS specification5KG
2020?\" thick Rubber Insertion as per IS specification10KG
2121Provision for wiring to the Pump Chamber1NO
2222Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge.1NO
2323Cost of 300 mm R.C.C. hum pipe( NP 3 )as per specifications including laying & fitting5MTR
2424Supplying of 200mm dia unplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.40 to 1.46 gms/cc of straight length of 6 (six) meter for portable water supplies conforming to IS - 4985 / 2000 of BIS - Amendment - 2 read with Table - 1 of IS - specification bearing ISI marks for working pressure CI - I UPVC pipe to withstand pressure of 2.5 kgf/sqcm & the specification and manufacturer name should be prominently marked on body of each pipe as per the latest Amendment of IS - 4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transportation to work site in complete shape.528MTR
2525Fitting of un plasticised 200mm dia PVC Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non-head application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from factory to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge.528MTR
2626Supplying of 160mm dia unplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.40 to 1.46 gms/cc of straight length of 6 (six) meter for portable water supplies conforming to IS - 4985 / 2000 of BIS - Amendment - 2 read with Table - 1 of IS - specification bearing ISI marks for working pressure CI - I UPVC pipe to withstand pressure of 2.5 kgf/sqcm & the specification and manufacturer name should be prominently marked on body of each pipe as per the latest Amendment of IS - 4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transportation to work site in complete shape.996NO
2727Fitting of un plasticised 160mm dia PVC Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non-head application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from factory to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge.996MTR
2828160X160X100mm dia M.S outlet Tee made with 151mm ID and 159 mm OD M.S Pipe of 8mm thick 400mm long fitted with 1 mtr long 100mm dia M.S.Pipe welded with 2 nos of 100mm dia M.S.Flange in between the 1 mtr M.S.Pipe and 0.25 mtr long 100 mm dia M.S.Pipe fitted horizentally with 2 mtrs of 100mm dia M.S.Elbow with water locking arrangement made out of 1 no. of 100mm dia open flange and 1 no. of 100mm dia blind flange and with hinges gaskets arrangement that UPVC pipe should be inserted directly 100mm long inside the 151mm dia ID M.S.Pipe at the both ends painted with two coats of anti corosive paints in complete set.20NO
2929Cost of 200 mm x200 mm x200 mm Ø PVC Tee12NO
3030Monoblock pump set total head of 21 mtrs capable to discharge 1700 LPM with 12.5HP/9.5KW squirrel cage induction motor fitted with bronze impeller TB-2 of IS 318/1981, companion flanges & Class \"F\"insulation suitable for operation 415 volt +6%-15% 3 phase, 50Hz AC poweer supply suction/deliveery = 100mmx100mm with BEE Star rated energy efficiency Pump & as per IS-9079/2002 with overall efficiency 62 to 65% of reputed brand having wide dealership net work for easy availability of spares.1NO
3131Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 10 HP with 16 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 6.00 to 9.50 Amp & no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The Starter should provide dependable protection against over load and single phasing fitted with Volt meter,Ameter,MCB in complete shape including Indicator Lamp1NO
323263 Amp Main Switch Triple pole & neutral of voltage range 440 volt of re-wirable fuse and shall confirm to IS 4064 part I & with ISI mark.1NO
3333Motor hood size (0.45mx0.45mx0.60m) made with 18 SWG (cold rolled M.S.Sheet with one coat of red oxide primer and two coats of smoke gray / navey blue enamel n both side (inside & outside) suitable to cover centrifugal monoblock Pump Set from 10 HP to 15 HP and having provision for attachement with the groves on rear side of the pannel board.1NO
3434Base Plate made of MS Channel with holes1NO
35356 KVAR Power Shunt Capacitor1NO
3636Earthing installation with required earthing materials like charcoal, common salt, conduit pipe, soft solder alcaps ,nuts & bolts, cable socket etc. including excavation of earth pits 2 Nos of size 1200mm X1200mm X 3200mm for fixing of earthing pipe 2 Nos of size 40mm dia X 3000 mm length with required slotting in pipes & fittings with 40 mm dia G.I.Flange etc. includidng excavation of earthing trench for laying of earthing G.I.Wire & filling the Trench Pits after fixing of pipes on completion on earthing work and pannel wiring with required 4mm2/2.5mm2 PVC coper wire including supply & transportation of materials to work site as per the direction of site Engineer in-charge2NO
37373x 16 sqmm Tarpodar cable XLPE (Cross link polyethylin) conforming to IS: 7098 (Part-II) including laying below 0 .9mtr. of the ground and filling the excavated materials including watering and ramming.20MTR
38384mm² 3 core submersible flat cable of ISI50MTR
3939100 mm Ø nominal bore G.I. pipe having wall thickness 4.5 mm electrical resistance welded of medium class confirming to IS - 1239 (pt-1 of 2004) with socketed at one end and the other end protected with plastic thread protector. The socket confirming to IS-1239 (pt-II/1992) with latest amendmewnts in random length of 4 to 7 mtrs. Each pipe should bear ISI certification & manufacturers name / Trade mark.12MTR
4040100 mm dia G.I. bend IS No.1239(Part-II/1992)4NO
4141100 mm Ø C.I. Foot Valve should be of swing type friction less with single disc confirming to IS – 4038/1979 of reputed brand1NO
4242100 mm dia G.I. flange IS No.6392 / 197112NO
4343100 mm Ø Sluice Valve Flanged type of Manufacturing Standard - BS 5163 / IS14846 Pressure Ratings PN10.1NO
4444100mm Non-return valve C I double flanged swing type PN - 1.0 as per IS:5312 part-I with by-pass arrangement1NO
4545200 mm M.S. pipes with plain ends in random length of 4 to 7 mtrs. Confirming to BIS 3589 with minimum wall thickness of pipes should be 5.5 mm each pipe should bear ISI specification and manufacturers name / Trade mark. Steel grade of the pipe should be Fe33072MTR
4646Cost of 200mm MS/Steel slipon flange24NO
4747Cost of 200 mm Ø PVC Bend1NO
4848200 mm Ø PVC End Cap (W.P. 10 kgf/cm2) confirming to IS-4995/1988 with latest ammendment1NO
4949200 mm Ø PVC coupler (4 kg/cm2) Agricultural PVC fittings confirming to IS-4995/1988 with latest ammendment6NO
5050Cost of River Bank cutting & shaping for const. of P.F.1NO
5151Cost of 160 mm PVC Equal Tee2NO
5252160 mm Ø PVC End Cap (W.P. 10 kgf/cm2) confirming to IS-4995/1988 with latest ammendment14NO
5353160 mm Ø PVC coupler (4 kg/cm2) Agricultural PVC fittings confirming to IS-4995/1988 with latest ammendment10NO
545450 mm Ø Air release valve with saddle & Raiser pipe. The air release valve shall confirm to IS 14845 with ISI mark.2NO
5555Cost of 160mm Butterfly Valve13NO
5656Cost of 160mm PVC Tail piece with flange26NO
5757Cost of 160mm dia PVC Bend1NO
5858100x100x25mm G.I. Tee with Plug1NO
5959Cost of 200 mmx160 mm PVC Reducer13NO
6060200 mmx100 mm M.S. Reducer Fabricated1NO
6161Welding, laying and fitting of 200 mm Ø MS pipe72MTR
6262Labour charges for installation of 10HP Motor including fitting & fixing of base frame, fitting & fixing suction and delivery pipe to motor, NR Valve, Foot Valve, Sluice Valve and other fitting materials including cutting, welding and construction of supporting pillar etc. complete as per the direction of the Engineer-incharge.1NO
6363Supply of solvent cement of approve quality for joiniting of PVC Pipe with all cost and all tax etc. complete as per the direction of the Engineer-incharge.15LTR
6464Installation of 63 KVA,11/.4 KV Pole mounted Sub-Station using 9 Mtr long PSC pole with Stare Ratted Transformer as per the specification & estimate of DISCOM1NO
6565Construction of 11 K.V.Line 3 Ph 3 Wire with 9 Mtr long 300kg PSC pole using 55 sq.mm insulated Conductor 80 mtr span with all materials required for the same as per the specification & estimate of DISCOM0.15KM
6666L.T.Line 3ph 4w using 3x50+1x35sq.mm XLPE ABC & 8 mtr long PSC poles with fittings with all materials required for the same as per the specification & estimate of DISCOM0.35KM
67673P 3W 11Kv line DP with 400Amp AB switch on 9M X 300Kg PSC pole as per the specification & estimate of DISCOM1NO

AI Tender Summary

OUR REF NO 26006727
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 26-11-2020
Authority
Authority Name Orissa Lift Irrigation Corporation Limited
Work Description Installation And Energisation Of Mahaling Vi Of New Lift Irrigation Project Under Golamunda Block In Kalahandi District Construction Of Head Works , Distribution System And Energisation Including Power Supply Work
Basic Detail
Tender No OLIC-BPT-05/2020-21
Bidding Type Tender
Location
City GOLAMUNDA
State Odisha
Key Dates
Publish Date 16 Nov 2020
Submission Date 26 Nov 2020
Open Date 27 Nov 2020
Finance
Tender Value Ref. Documents
Tender Fee 6000
EMD 24755
Exemption Not Available
Document List
29MahalingVI.pdf
BOQ_333754.xls
B25EB9F3-61F4-4A0F-B674-7F7A81BB65C1.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 16, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 26, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 27, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

29MahalingVI.pdf

xls

BOQ_333754.xls

html

B25EB9F3-61F4-4A0F-B674-7F7A81BB65C1.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders