Structural Repair Work Of Buildings Located At Varunapuri I Ii Iii Map Area And Ram Mandir Area Under Age Br Ii Area Of Ge Nw Vasco, CWE NAVY VASCO-Goa

Military Engineer Services-MES has published Structural Repair Work Of Buildings Located At Varunapuri I Ii Iii Map Area And Ram Mandir Area Under Age Br Ii Area Of Ge Nw Vasco. Submission Date for this Tender is 07-01-2021. Structural Work Tenders in CWE NAVY VASCO Goa. Bidders can get complete Tender details and download the document.




Tender Notice

25978284
Corrigendum : Structural Repair Work Of Buildings Located At Varunapuri I Ii Iii Map Area And Ram Mandir Area Under Age Br Ii Area Of Ge Nw Vasco
Open Tender
Indian
Goa
CWE NAVY VASCO
07-01-2021

Tender Details

Structural Repair Work Of Buildings Located At Varunapuri I Ii Iii Map Area And Ram Mandir Area Under Age Br Ii Area Of Ge Nw Vasco

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Nov-2020 DATECORRI Date 09-12-2020
2 02-Dec-2020 DATECORRI2 Date 19-12-2020
3 12-Dec-2020 DATECORRI3 Date 26-12-2020
4 18-Dec-2020 BOQCORRI BOQ 31-12-2020
5 18-Dec-2020 BOQCORRI Other 31-12-2020
6 31-Dec-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-01-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 98600.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK :- STRUCTURAL REPAIR WORK OF BUILDINGS LOCATED AT VARUNAPURI-I, II, III, MAP AREA & RAM MANDIR AREA UNDER AGE B/R-II AREA OF GE (NW) VASCO
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for taking down loose and damaged concrete cement plaster from soffit of ceiling floor/slab, vertical surfaces of column beams,slab etc including exposing and removing rust from reinforcement by rubbing with wire brush and plenty of water so as to remove the loose particles,dust,laitance etc. and removal of debris to a distance n.exc 50m and deposited where directed all as specified and as directed. 2100 Sqm
2 2 M&L for applying one layer of cement concrete 40mm thick comprises composition 50 Kg cement ,3 to 6mm chips 100 Kg, sand 50 Kg mixed with spray set SL 3 to 2.5 by weight of cement and 12.5 to 16.5 litres of water mixed with admixture including bonding agent and applying rust remover and gunitting with pressure nozzle with a delivery capacity of 2.5 Kg/Sqm including use of welded steel wire fabric as required all as specified and as directed.\nNote : Welded steel wire fabric shall be measured and paid as "Supply Only" 1100 Sqm
3 3 All as per item No 2 here in before, but 30mm thick as in beam all as specified and as directed. 500 Sqm
4 4 All as per item No 2 here in before, but 20mm thick as in ceiling all as specified and as directed. 500 Sqm
5 5 Supply only welded steel wire fabric weight n exc 4 kg per sqm all as specified and as directed. 3000 Kg
6 6 M&L for TMT steel bars 8mm dia, cut to length, bent to shape required and welded to existing reinforcement of any description and any position of RCC structure after binding with mild steel wire annealed not less than 0.9 mm dia ss an addl bar complete all as specified and as directed. 300 Kg
7 7 M& L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed. 300 Kg
8 8 M& L for providing 10mm thick plaster in cement mortar 1:6 finished to even & smooth without using extra cement over gunniting surface all as specified and as directed. 1600 Sqm
9 9 M& L for rendering 5mm thick on ceiling in cement mortar 1:3 finished even and smooth without using extra cement over gunniting surface all as specified and as directed. 500 Sqm
10 10 Taking up/down old GI tubing and connection of size 15mm bore complete all as specified and as directed. 100 RM
11 11 Taking up/down old GI tubing and connection of size 20mm bore, complete all as specified and as directed. 100 RM
12 12 S & F CPVC water tubing 15mm bore, (20mm outer dia) SDR-11 grade with all fittings and fixed complete to wall/Ceilings or laid in floors all as specified and as directed. 100 RM
13 13 S & F CPVC water tubing 20mm bore, (25mm outer dia) SDR-11 grade with all fittings and fixed complete to wall/Ceilings or laid in floors all as specified and as directed. 100 RM
14 14 M&L for preparation of old surface of ceiling and applying one coat of oil bound distemper all as specified and as directed. 2000 Sqm
15 15 M & L for preparing the old treated surfaces of wall and applying one coat of exterior grade weather proof antifungal paint complete all as per manufacturers instructions and as directed. 4000 Sqm
16 16 Taking down cement plaster of any description on brick or stone walls including racking out joint, hacking for key, scrubbing down with water etc all as specified and as directed. 3100 Sqm
17 17 M & L for preparing newly plastered surfaces of wall and applying two coats of OBD over a coat of alkali resistant primer all as specified and as directed. 500 Sqm
18 18 M & L for rendering 5mm thick on ceiling in cement mortar 1:3 finished even and smooth without using extra cement all as specified and as directed. 300 Sqm
19 19 M & L for preparing newly plastered surface of ceiling and applying two coats of oil bond distemper over a coat of alkali resistant primer all as specified and as directed. 300 Sqm
20 20 M & L for rendering 10 mm thick on wall in cement mortar 1:6 on stone/masonry surfaces finished even and smooth without using extra cement all as specified and as directed. 500 Sqm
21 21 M&L for 3mm thick wall care putty on wall all as specified and as directed. 500 Sqm
22 22 M & L for rendering 15mm thick plaster in cement mortar 1:4 in two coats (10 mm thick backing coat + 5mm thick finishing coat) finished even and smooth without using extra cement including water proofing compound (200 ml per bag of cement ) etc complete all as specified and as directed. 2300 Sqm
23 23 M&L for preparation of old painted surfaces of wall and applying one coat of oil bound distemper all as specified and as directed. 8500 Sqm
24 24 M & L for preparation of newly plastered surface and applying two coats of raincoat. Prime the surface with a coat of PRIMESEAL diluted with potable water in ratio 2:1 by volume prior to application of raincoat and allow it to dry for 2 to 3 hrs. Apply first coat of raincoat. Apply second coat of raincoat with an interval of 5 to 6 hrs and allow to cure for 7 days all as directed and as per manufactures instruction.\nNote:- Priming coat and raincoat used shall be same Make/Manufactures. 4300 Sqm
25 25 Dismantling CI drain pipe 75/110 mm dia and taking out from walls/ trenches if required all as specified and as directed. 300 RM
26 26 S & F PVC (SWR) pipe 110 mm dia single socketed in any length with rubber ring jointed, fixed to wall with necessary clamping all as specified and as directed. 150 RM
27 27 S & F PVC (SWR) pipe 75 mm dia single socketed in any length with rubber ring jointed, fixed to wall all as specified and as directed. 150 RM
28 28 S & F PVC (SWR) bends any radius 110 mm bore all as specified and as directed. 20 Each
29 29 S & F PVC (SWR) bends any radius 75 mm bore all as specified and as directed. 20 Each
30 30 S & F PVC (SWR) branch piece, single (Single Y) equal or unequal, 110 mm bore all as specified and as directed. 20 Each
31 31 S & F PVC (SWR) branch piece, single (Single Y) equal or unequal, 75 mm bore all as specified and as directed. 20 Each
32 32 S & F PVC (SWR) vent cowl 110mm bore all as specified and as directed. 20 Each
33 33 Disconnecting existing tanks of exc 250 Ltr capacity and n exc 500 Ltr capacity setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position. Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc, all as specified and as directed. 3 Each
34 34 Disconnecting existing tanks of exc 500 Ltr capacity and n exc 1000 Ltr capacity setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position. Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc, all as specified and as directed. 3 Each
35 35 M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the mother slab, filling the crack upto 2mm wide with suitable crack filler, maintaining a suitable slope for water drainage and reinstate damaged portion with polymer modified mortar as recommended and allow it to cure for 24 hrs. Brush apply the 1st Priming coat on prepared concrete/plastered surface and allow to dry for 04 (four) hours. Apply the first coat of waterproofing coating over the primed surface. On the wet surface of 1st coat overlay a open-woven fibre glass mesh, min 40 GSM of size 2mm x 2mm and allow it to soak completely. Immediately apply the second coat with a roller, to ensure complete coverage of the fibre mesh. Apply the third coat after 6 to 8 hrs once the second coat is dry. Drying time between coats will be 6 to 8 hours all as directed and as per manufacturers instructions. \nNotes: (i) Crack filler, priming coat and water proofing coat used shall be of same Make/Manufacturer.\n(ii)The quoted rate deemed to be inclusive of crack filling,minor repair required for making the surface smooth,repair mortar for damaged portion.\n(iii)Application to be done through authorized applicator of the manufacturers only 80 Sqm
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail