Hiring Of Consultancy For Setting Up Of Centre For Intermediate Level Maintenance ( Cilm ) Of Lm 2500 Gas Turbines At Ins Eksila Hiring Of Consultancy For Setting Up Of Centre For Intermediate LevelMaintenance Cilm Of Lm 2500 Gas Turbines At Ins Eksila , Consultancy Services For Preparation Of Detailed Architectural/Structural Drawing For The Following Buildings ( Plinth Area ) Etc Including Preparation Of Site Plan Showing Various Entities As Per Bps , Geo Tech Investigation , Detailed Structural Drgs For Foundation , Super Structure And Pile Foundation Etc Duly Vetted By Any Iit/Nit/Andhra University Etc With Prior Approval Of Accepting Officer Including Feasibility Of Construction At Location Considering All Constructual Parameters , Preparation Of Drg For Internal E/M Services ( Including Internal Electrification , Lan & Telephone ) , Preparation And Submission Of Bill Of Quantities ( Boq ) Along With Detail Estimation Of Each Item Of Quantities As Per Format Given By Ssw / Dgnp ( V ) Including Calculation Of Steel Including Bar Binding Schedule , Concrete Item ( Ie Cement , Sand , Aggregate Etc ) For Each Buildings , Including B/R & E/M Services ( Such As Sewage Disposal , Compound Wall/Gate , Air Conditioning ( Havc ) , Eot Crane , Lightening Protection , Fire Fighting System ( Fire Detection & Fire Alarm ) And , Item No . 1 ( Contd . . , ) Road/Path/Culvert/Area Drainage Along The Building Etc ) , Preparation Of Specification And Tender Documents For Buildings And Services ( B/R & E/M ) , Preparation Of Yard Stick For All Bldgs Based On Mes Ssr Part Ii , Clarification/Technical Details Required During Execution Of Work On Ground And Clearances From Navy/State/Central Govt Deptt In Vizag/Delhi/Elsewhere As Applicable As Per Policy In Vogue . Preparation Of Tender Documents As Per Format Given By Ssw , Dgnp ( V ) For Uploading By Dgnp ( V ) :- , ( A ) Cilm Bay ( I ) Workshop Area 15Mtr Height = 1375 Sqm ( Ii ) Eot Cranes ( 10/2 Ton - 01 , 40/5 Ton - 01 ) Hook Height - 10 Mtrs ( Iii ) Main Technical Building = 825 Sqm ( Gf+ Ff ) ( B ) Auxiliary Rooms ( I ) Compressor Room = 61 . 25 Sqm , 6 Mtr Height ( Ii ) Ac Plant With Ramp = 292 Sqm , 6 Mtr Height ( Iii ) Ahu = 242 . 50Sqm , 6 Mtr Height ( Iv ) Cooling Towers ( V ) Sub Station Building With Ramp = 73 . 25Sqm , 6 Mtr Height ( Vi ) Dg Room With Ramp = 125 . 75Sqm , 6 Mtr Height ( Vii ) Equipment Room With Ramp = 134 . 50 Sqm , 6 Mtr Height ( Viii ) Toilets Block = 61 . 25 Sqm ( C ) Fire Fighting Arrangement - Comply With Cfees Recommendations ( I ) Static Water Tank - 75000 Ltrs Capacity ( Ii ) Pump Room = 61 . 25 Sqm , 6 Mtr Height ( Iii ) Over Head Water Tank - 30000 Ltrs Capacity - Min Height 18M ( Iv ) Rcc Sump - 3000 Ltrs Capacity ( V ) Fire Alarm & Fire Detection ( Vi ) External Fire Fighting , ( D ) Security Requirements ( I ) Guard Room Including Toilet = 47 . 60 Sqm ( Ii ) Security Room = 42 . 50 Sqm ( Iii ) Qrt Room Including Toilet = 96 . 05 Sqm ( Iv ) Dsc Watch Towers - 4 Nos = 60 Sqm , 15 Mtrs Height ( Incl Rest Room With Toilet ) ( E ) Two Wheeler Parking Shed = 178 . 71 Sqm ( F ) Layout And Design Of Roads Upto And Around Cilm Bldg As Shown In Bps . ( G ) Boundary Wall/Compound Wall Of Height 3 . 00 Mtr Approximate 60 Mtr Length Including 3 Nos Of Security Gate 8 Mtr With Rcc Arched Entrance Of Height 8 Mtrs As Shown In Bps , Notes :- ( A ) Rcc Design Mix ( Rmc ) Shall Be Considered . ( B ) Reinforcement Tmt Bars ( Crs ) Fe-500D Shall Be Considered . ( C ) Aac Blocks Shall Be Used . ( D ) All Requirement As Per Bps To Be Incorporated In The Drawing , Estimate , Specification & Tender Etc . ( E ) All Specification Shall Be Followed As Mes Ssr Part I And Rates Shall Be As Per Mes Ssr Part Ii ( F ) All Architectural/Structural Drawing And E/M Services Drawing Before Finalisation Shall Be Submitted To E-6 Section / E-2 Design Section And Dir ( Utility ) Of Dgnp ( V ) For Necessary Approval Including Submission Of Drawing For User Approval . , Notes ( Contd . . , ) :- ( G ) Presentation On Final Document Of The Subject Work Alongwith Sample Modules Showing Orientation Of Building And Internal/External Services , Alongwith 3D Rendered Views And 3D Animated Walkthrough Presentation Including Submission Of Presentation Documents In Soft/Hard Copies Will Be Arranged By The Contractor At Dgnp ( V ) Office As Directed . ( H ) Adequate Numbers Of Visit Of Consultants Expertise To Site Of Work/Office Of Dgnp ( V ) To Be Provided As And When Directed At Least 1-2 Visits Be Planned In A Quarter . ( J ) All State Govt Compliances Shall Be Taken As Per The Law Of The Land . ( K ) Local Office With At Least One Civil Engineer And One E&M Engineer To Be Established Within 15 Days Of Getting The Work Order Till Finalisation Of The Contract . Thereafter , Minimum One Rep To Be Available For Griha-3 Star Rating . , Preparation Of Tender Documents For Workshop And Main Technical Building Only ( Area 2200 Sqm ) With An Aim To Obtain Griha Registration , Pre-Certification And Griha Certification To Achieve Griha 3-Star Rating Including Organising , Conducting , Monitoring Of Site Visits By Griha Experts For Griha Rating Assessment , During Currency Of The Project And After Completion Till Handing Over Of Certification As Per Griha Policy .