Bharat Sanchar Nigam Limited-BSNL has published Cmc Of Ea Sets Above 30Kva And Split Ac Units And Maintenance Of Ea Sets Below 30Kva On Call Basis In Ssa Latur Recalled 3Rd. Submission Date for this Tender is 19-11-2020. Electric Generator Tenders in LATUR SSA Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

25945447
Cmc Of Ea Sets Above 30Kva And Split Ac Units And Maintenance Of Ea Sets Below 30Kva On Call Basis In Ssa Latur Recalled 3Rd
Open Tender
Indian
Maharashtra
LATUR SSA
19-11-2020

Tender Details

Cmc Of Ea Sets Above 30Kva And Split Ac Units And Maintenance Of Ea Sets Below 30Kva On Call Basis In Ssa Latur Recalled 3Rd , Sub Head-I ( Cmc Of Ac Units ) , Comprehensive Maintenance Of Window / Split / High Sensible & Package Ac Units Of Following Capacity As Per The Terms And Conditions Enclosed . ( I ) Ac Units Completed Life Less Than 5 Years From The Date Of Commissioning I ) Split Ac ( 1 . 5Tr ) For First Year , Ii ) Split Ac ( 1 . 5Tr ) For Second Year , Sub Haed-Ii ( Cmc Of Ea Sets ) , Cmc Of Ea Sets Completed Life More Than 5 Years From Date Of Commissioning Of Following Ratings As Per The Terms And Conditions Enclosed . I ) More Than 20 Kva To 45 Kva Ea A ) 1St Year , B ) 2Nd Year , Ii ) More Than 45 Kva To 75 Kva Ea A ) 1St Year , B ) 2Nd Year , Iii ) More Than 75 Kva To 100 Kva Ea A ) 1St Year , B ) 2Nd Year , Iv ) 125 Kva Ea A ) 1St Year , B ) 2Nd Year , Servicing & Routine Maintenance ( B Check ) Of Following Capacity Of Ea Set Complete With Cleaning Of Air Filter Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Replacement Of Lube Oil Filter Elements , Replacement Of Fuel Filter Elements , If Required Replacement Of Radiator Coolant With Distilled Water & Addition Of Coolant Additive Concentrate , Checking & Reset Injector Pressure , Injector Pump Timing , Tightening Of Cylinder Head Studs / Nuts , Adjustment Of Engine Valve Clearance , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Air Piping , Belt Tensions I / C Cleaning & De-Dusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc . Actual Load Testing Of Ea Set After Servicing As Directed . [ B Check Once In 12 Months ] I ) More Than 20 Kva To 45 Kva Ea , Ii ) More Than 45 Kva To 75 Kva Ea , Iii ) More Than 75 Kva To100 Kva Ea , Iv ) 125 Kva Ea , Supplying & Fixing Of Fully Charged 12 Volt Lead Acid Maintenance Free Battery Of Following Rating For Starting Of Ea Set Complete With End Lugs Etc Note:- Battery Replacement Once During Currency Of Contract After Considering Rebate For Old Battery For Quoting Rate . I ) 130 Ah , Ii ) 150 Ah , Sub Haed-Iii ( Mtce . Of Ea Sets On Call Basis ) , Attending Complaint And Checking Of Faults Of Ea Set By Skilled Technician , Rectification Of Minor Faults / Wiring / Lubricating Etc . As Reqd For The Following Distance Of One Side From Sub Divisional Office . This Item Shall Be Paid Once In 4 Months Period . Any Subsequent Visit Required Shall Be Borne By The Firm Within Stipulated Period Of 4 Months . ( I ) Upto 50 Kms , ( Ii ) Above 50 To 100 Kms , Servicing & Routine Maintenance ( B-Check ) Of Following Capacity Of Ea Set Complete With Cleaning Of Air Filter Element , Replacement Of Engine Lube Oil Of Proper Grade ( Seal Pack Of Reputed Make ) , Lube Oil Filter & Fuel Filter Elements , Radiator Coolant With Distilled Water & Addition Of Coolant Additive Concentrate , Checking & Reset Injector Pressure & Pump Timing , Tightening Of Cylinder Head Studs , Adjustment Of Engine Valve Clearance , Cleaning Of Radiator Fins , Drain Sediments From Water Separator , Check Inlet Air Restriction , Air Piping , Belt Tensions I / C Cleaning & De-Dusting Of Alternator , Control Panel , Fuel Tank , Tightening & Maintaining Of All Hose Connections , Electrical Connections , Battery Connections Etc . Actual Load Testing Of Ea Set After Servicing As Directed . [ B Check Once In 12 Months ] I ) Upto & Including 20 Kva Ea , Ii ) More Than 20 Kva To Below 30 Kva Ea , Supplying & Fixing Of Fully Charged 12 Volt 88Ah Battery For Starting Of Ea Set Complete With Lugs ( I / C Credit Of Old Battery ) Of Following Types:- ( I ) Lead Acid Maintenance Free Battery , ( Ii ) Super Capacitors 120F Battery Suitable Upto 25Kva Dg Cranking System , Replacement Of Following By New Components Of Ea Sets Below 30 Kva I / C Fixing / Connections , Testing Etc . I / C Credit For Old Material As Reqd . , Below 30 Kva Ea Set ( I ) Oil Top Up ( With Recommeded Grade & Make ) , ( Ii ) Pump Caliberation From Authorised Dealer ( With Out Nozzle Replacement ) , ( Iii ) Starter Repair I / C Replacement Of Spares , ( Iv ) Charging Alternator Repair I / C Replacement Of Spares , ( V ) Fuel Inlet / Outlet Pipe , ( Vi ) Gasket Kit Excluding Sump Kit , ( Vii ) Automatic Voltage Regulator ( Avr ) , ( Viii ) Mains / Dg Contactor , ( Ix ) 32 A Tpn Mcb C Curve , ( X ) 63 A Fp Isolator , ( Xi ) Led Lamp Indication Lamp , ( Xii ) Stop Solenoid , ( Xiii ) Push Button , ( Xiv ) Voltmeter , ( Xv ) Ampere Meter , ( Xvi ) Oil Pressure Meter , ( Xvii ) Water Temp Meter , ( Xviii ) Oil Temp Meter , ( Xix ) Oil Pressure Pipe , ( Xx ) Smps 12 Volt , 10 Amp Battery Charger , ( Xxi ) Hose Kit , ( Xxii ) Fan Belt , ( Xxiii ) Water Pump Assembly , ( Xxiv ) Llop Switch , ( Xxv ) Water Temperature Switch 96 Deg . , ( Xxvi ) Exhaust Below , ( Xxvii ) Door Hinges , ( Xxviii ) Relay Card ( Start & Stop ) , ( Xxix ) Key Switch , ( Xxx ) Air Filter

Key Value

Document Fees
INR 590 /-
EMD
INR 28449.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:-CMC of E/A sets above 30kVA & split AC units and maintenance of EA sets below 30kVA on call basis in SSA Latur.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 SUB HEAD-I(CMC OF AC UNITS) SHI
2 2 Comprehensive Maintenance of Window / Split / High Sensible & Package AC units of following capacity as per the terms and conditions enclosed. (i) AC units completed life less than 5 Years from the date of commissioning i) Split AC ( 1.5TR ) for First year SH1_1 54 Nos. Annual
3 2.01 ii) Split AC(1.5TR ) for Second year SHI_1a 54 Nos. Annual
4 3 SUB HAED-II (CMC OF EA SETS) SHI_1b
5 4 CMC of EA sets completed life more than 5 Years from date of commissioning of following ratings as per the terms and conditions enclosed. i) More than 20 kVA to 45 kVA EA a) 1st Year SHI-2 10 Set Annual
6 4.01 b) 2nd Year SHI-3 10 Set Annual
7 4.02 ii) More than 45 kVA to 75 kVA EA a) 1st Year SHI-4 2 Set Annual
8 4.03 b) 2nd Year SHI-5 2 Set Annual
9 4.04 iii) More than 75 kVA to 100 kVA EA a) 1st Year SHI-6 1 Set Annual
10 4.05 b) 2nd Year SHI-7 1 Set Annual
11 4.06 iv) 125 kVA EA a) 1st Year SHII 3 Set Annual
12 4.07 b) 2nd Year SHII-1 3 Set Annual
13 5 Servicing & Routine maintenance (B check) of following capacity of EA set complete with cleaning of Air Filter element, replacement of engine lube oil of proper grade (seal pack of reputed make), replacement of lube oil filter elements, replacement of fuel filter elements, if required replacement of radiator coolant with distilled water & addition of coolant additive concentrate, Checking & reset injector pressure, injector pump timing, tightening of cylinder head studs/nuts, adjustment of engine valve clearance, Cleaning of radiator fins, drain sediments from water separator, check inlet air restriction, air piping, belt tensions i/c cleaning & de-dusting of alternator, control panel, fuel tank, tightening & maintaining of all hose connections, electrical connections, battery connections etc. Actual load testing of EA set after servicing as directed.\n["B" check once in 12 months] i) More than 20 kVA to 45 kVA EA SHII-2 20 Job Each
14 5.01 ii) More than 45 kVA to 75 kVA EA SHII-3 4 Job Each
15 5.02 iii) More than 75 kVA to100 kVA EA SHII-4 2 Job Each
16 5.03 iv) 125 kVA EA SHII-5 6 Job Each
17 6 Supplying & fixing of fully charged 12 volt lead acid Maintenance Free battery of following rating for starting of EA set complete with end lugs etc\nNOTE:- Battery replacement once during currency of contract after considering rebate for old battery for quoting rate. i)130 AH SHII-6 13 Each
18 6.01 ii)150 AH SHII-7 6 Each
19 7 SUB HAED-III (MTCE. OF EA SETS ON CALL BASIS) SHII-8
20 8 Attending complaint and checking of faults of EA set by skilled technician, rectification of minor faults/wiring/lubricating etc. as reqd for the following distance of one side from Sub Divisional Office. This item shall be paid once in 4 months period. Any subsequent visit required shall be borne by the firm within stipulated period of 4 months. (i) Upto 50 kms SHIII 15 Nos. Job
21 8.01 (ii) Above 50 to 100 kms SHIII-1 10 Nos. Job
22 9 Servicing & Routine maintenance (B-Check) of following capacity of EA set complete with cleaning of Air Filter element, replacement of engine lube oil of proper grade (seal pack of reputed make), lube oil filter & fuel filter elements, radiator coolant with distilled water & addition of coolant additive concentrate, Checking & reset injector pressure & pump timing, tightening of cylinder head studs, adjustment of engine valve clearance, cleaning of radiator fins, drain sediments from water separator, check inlet air restriction, air piping, belt tensions i/c cleaning & de-dusting of alternator, control panel, fuel tank, tightening & maintaining of all hose connections, electrical connections, battery connections etc. Actual load testing of EA set after servicing as directed.\n["B" check once in 12 months] i) Upto & including 20 kVA EA SHIII-2 20 Nos. Job
23 9.01 ii) More than 20 kVA to below 30 kVA EA SHIV 10 Nos. Job
24 10 Supplying & fixing of fully charged 12 volt 88AH battery for starting of EA set complete with lugs (i/c credit of old battery) of following types:- (i) Lead acid Maintenance Free battery SHIV-1 5 Each
25 10.01 (ii) Super Capacitors 120F battery suitable upto 25kVA DG cranking system SHIV-2 5 Each
26 11 Replacement of following by new components of EA sets below 30 kVA i/c fixing/connections, testing etc. i/c credit for old material as reqd. SHIV-3
27 12 Below 30 kVA EA set (i) Oil top up ( with recommeded grade & make) 30 Ltrs
28 12.01 (ii) Pump caliberation from authorised dealer (with out nozzle replacement) SHIV-4 5 Each
29 12.02 (iii)Starter repair i/c replacement of spares SHIV-5 5 Each
30 12.03 (iv) Charging alternator repair i/c replacement of spares SHIV-6 5 Each
31 12.04 (v)Fuel inlet / outlet pipe SHIV-7 5 Each
32 12.05 (vi)Gasket kit excluding sump kit SH-V 5 Each
33 12.06 (vii)Automatic voltage regulator (AVR) SH-V-1 5 Each
34 12.07 (viii)Mains / DG contactor 5 Each
35 12.08 (ix)32 A TPN MCB 'C' curve 5 Each
36 12.09 (x)63 A FP isolator 5 Each
37 12.1 (xi)LED Lamp indication lamp 5 Each
38 12.11 (xii)Stop solenoid 5 Each
39 12.12 (xiii)Push button 5 Each
40 12.13 (xiv)Voltmeter 5 Each
41 12.14 (xv) Ampere Meter 5 Each
42 12.15 (xvi)Oil pressure meter 5 Each
43 12.16 (xvii)Water temp meter 5 Each
44 12.17 (xviii) Oil temp meter SH-V-2 5 Each
45 12.18 (xix) Oil pressure pipe SH-V-3 5 Each
46 12.19 (xx)SMPS 12 volt, 10 Amp Battery Charger SH-V-4 5 Each
47 12.2 (xxi)Hose kit SH-V-5 5 Each
48 12.21 (xxii)Fan belt SH-V-6 5 Each
49 12.22 (xxiii)Water pump assembly 3 Each
50 12.23 (xxiv)LLOP switch 3 Each
51 12.24 (xxv)Water Temperature Switch 96 Deg. 3 Each
52 12.25 (xxvi)Exhaust Below SH-V-8 3 Each
53 12.26 (xxvii)Door Hinges SH-V-9 3 Each
54 12.27 (xxviii)Relay Card (Start & Stop) 3 Each
55 12.28 (xxix)Key Switch SH-V-10 3 Each
56 12.29 (xxx)Air Filter SH-V-11 3 Each