Kochi Metro Rail Limited has published Supply , Installation , Testing And Commissioning Of Street Light Poles Including Led Luminaries And Bollards As Part Of Construction Of Redevelopment Of Kunaara Park And Metro Station Connectivity From Thykoodam To Petta . Supply , Installation , Te. Submission Date for this Tender is 31-12-2020. LED Light Tenders in Kochi Kerala. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 19-Nov-2020 | Corrigendum 2 | Date | 21-12-2020 |
2 | 07-Dec-2020 | Corrigendum 3 | Technical Bid | 21-12-2020 |
3 | 16-Dec-2020 | Date Corrigendum 2 | Date | 31-12-2020 |
4 | 28-Dec-2020 | Corrigendum 4 | Other | 31-12-2020 |
Name of Work: Fabrication, Supply and Installation of Metro Station Interior works including all transportation, loading and unloading, etc. for Ernakulam South, Vyttila & Petta Metro Station of Kochi Metro Rail Limited Project. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Electrical Items : | |||
2 | 1.01 | RCC Foundation for Lighting Pole including shuttering works and reinforcement (unit in cubic meter). Foundation: adequate size M20 grade RCC foundation with Raft including excavation shall be done by the contractor. Contractor/Pole manufacturer shall submit design calculation in support of size of RCC foundation for external lighting poles for approval. | item1 | 100 | CUM |
3 | 1.02 | Supply , erection,Testing and commissiong of square type Lighting pole. Upper arm length shall be min 1100mm and lower arm length shall be min 700 mm. Square Lighting pole asymmetrical Arm – 7 meter total height .The upper arm 6.4 meter and second arm at 5 meter. Pole has a built-in control box with service door including lock and safety chain. Dimension of Square type lighting pole 100mm x 100mm x 2.5mm thick and height of 7000 mm. Pole shall be coated with epoxy zinc phosphate primer of 40 microns and finished using environmentally stable polyurethane based paint of 40 microns. Pole with base plate GI of dimension 300mm x300mm x 16mm thick. Wind speed consideration in pole design shall be minimum 50 m/sec. Steel of grade YSt 210 to IS 4923:1997 in galvanized condition to be used for manufacturing square hollow sections. Steel used for manufacturing base plate is of Grade E250 to IS 2062:2011 in galvanized condition and foundation bolt is of Grade 5.6 in galvanized condition. Pole is hot dip galvanized to 80 microns to IS 2629:1985 / IS 4759:1996 / IS 2633:1986. The pole shall include 4 Nos. of hot dip galvanized M20 x 500mm foundation bolts. .The weather proof control gear tray shall be prewired with 2.5 sq. mm cable, Siemens / Crabtree / equivalant MCB, terminal connectors for loop-in loop-out arrangement suitable of terminating aluminium armoured cables up to 25 Sq.m size. The pole shall be integrated with LED module of 60W and 30W. The luminaire shall have an Integral power supply along with an earth connection and 10KV surge protection. - Luminaire shall be pre-wired. The pole shall be with foundation bolt, fittings, internal cabling, painting and printing of KMRL logo on Poles by consultation with KMRL. The LED luminaire shall meet the following details.\nSystem Lumens: Min 6000 Lumens for 60 w and 3000 lumens for 30 W, Luminaire Efficacy: 110 Lumen/Watt or above , CCT: 4000K, CRI: 70,a driver with surge protection of 10/10 kv, THD<=15%, PF:>=0.95, Life Span: 50000 Hrs, Degree of Protection for LED module and Driver shall be minimum IP66 rating (Refer Annexure-I for drawing) | item2 | 6 | NOS |
4 | 1.03 | Supply , Erection.testing & Commissioing of square cross section pole and 30w LED with the following details. Total height of the pole shall be 3.5 metre.Pole has a built-in control box with service door including lock and safety chain. The weather proof control gear tray shall be prewired with 2.5 sq. mm cable, Siemens / Crabtree or equivalent make MCB, terminal connectors for loop-in loop-out arrangement. Dimension of Square type cross section lighting pole 100mm x 100mm x 2.5mm thick and height of 3500 mm. Pole shall be coated with epoxy zinc phosphate primer of 40 microns and finished using environmentally stable polyurethane based paint of 40 microns. Pole with base plate GI of dimension 300mm x300mm x 16mm thick. Wind speed consideration in pole design shall be minimum 50 m/sec. Steel of grade YSt 210 to IS 4923:1997 in galvanized condition to be used for manufacturing square hollow sections. Steel used for manufacturing base plate is of Grade E250 to IS 2062:2011 in galvanized condition and foundation bolt is of Grade 5.6 in galvanized condition. Pole is hot dip galvanized to 80 microns to IS 2629:1985 / IS 4759:1996 / IS 2633:1986. The pole shall include 4 Nos. of hot dip galvanized M20 x 500mm foundation bolts. .The weather proof control gear tray shall be prewired with 2.5 sq. mm cable, Siemens / Crabtree / equivalant MCB, terminal connectors for loop-in loop-out arrangement suitable of terminating Al armoured cables up to 25 Sq.m size. The pole shall be integrated with LED module of 30W. The luminaire shall have an Integral power supply along with an earth connection and 10KV surge protection. - Luminaire shall be pre-wired. The pole shall be with foundation bolt, fittings, internal cabling, painting and printing of KMRL logo on Poles by consultation with KMRL. The LED luminaire shall meet the following details.\nSystem Lumens: Min 3000 lumens for 30 W, Luminaire Efficacy: 110 Lumen/Watt or above , CCT: 4000K, CRI: 70,a driver with surge protection of 10/10 kv, THD<=15%, PF:>=0.95, Life Span: 50000 Hrs, Degree of Protection for LED module and Driver shall be minimum IP66 rating .(Refer annexure-II for drawing) | item3 | 180 | NOS |
5 | 1.04 | Supply, Erection,testing & Commissioning of tubular pole and 40w LED with the following details. Total height of the pole shall be 4 metre,Symmetric optics with aluminium body having two sections ,bottom section of minimum 1000mm(L) x 140mm dia and the top section with minimum of 3000mm(L) x 76mm dia.Pole shall have a built-in control box with service door including lock and safety chain. Dimension of bottom section(1000 mm height) lighting pole shall be 140mm dia x 2.5mm thick and Dimension of top section(3000 mm height) lighting pole shall be 76mm dia and 2.5mm thick. Pole shall be coated with epoxy zinc phosphate primer of 40 microns and finished using environmentally stable polyurethane based paint of 40 microns. Pole with base plate GI of dimension 250mm x250mm x 12mm thick. Wind speed consideration in pole design shall be minimum 50 m/sec. Steel of grade YSt 210 to IS 4923:1997 in galvanized condition to be used for manufacturing square hollow sections. Steel used for manufacturing base plate is of Grade E250 to IS 2062:2011 in galvanized condition and foundation bolt is of Grade 5.6 in galvanized condition. Pole is hot dip galvanized to 80 microns to IS 2629:1985 / IS 4759:1996 / IS 2633:1986. The pole shall include 4 Nos. of hot dip galvanized M16 x 450mm foundation bolts.The weather proof control gear tray shall be prewired with 2.5 sq. mm cable, Siemens / Crabtree / equivalant MCB, terminal connectors for loop-in loop-out arrangement suitable of terminating Al armoured cables up to 25 Sq.m size. The LED luminaire shall meet the following details.\nSymmetric optics with aluminium body .System Lumens: Min 3000 Lumens, Luminaire Efficacy: Minimum 70 Lumen/Watt, CCT: 4000K, CRI: 70,a driver with surge protection of 10/10 kv, THD<=15%, PF:>=0.95, Life Span: 50000 Hrs, Degree of Protection for LED module and Driver shall be minimum IP66 rating (Refer annexure-IV for drawing) | item4 | 16 | NOS |
6 | 1.05 | Supply , Erection,testing & Commissioning of Bollard light fixture for landscape area including min16W LED integrated mode Dimension: Height shall be min 1000 mm. Light emission 360 degree. Built in 4 KV surge protection device. The luminaire body shall be provided with mild steel ,cadmium plate with paint .The bollard shall be provided with connectors for loop-in loop-out arrangement. Cast Iron base plate of size min 200mm x 200mm x 8 mm thickness having 4 holes of the bollard with noncorrosive stainless steel grub screws. The supply shall include hot dip galvanized foundation bolts as per design and manufacture recommendation.. The bollard shall be finished with polyester powder coated with suitable foundation. The LED luminaire shall meet the following details.\nSystem Lumens: Min 350 lumens for 16 W, Luminaire Efficacy: 20 Lumen/Watt or above , CCT: 4000K, CRI: 70,a driver with surge protection of 4 kv, THD<=15%, PF:>=0.95, Life Span: 50000 Hrs, Degree of Protection for LED module and Driver shall be minimum IP66 rating .(Refer annexure V for drawing) | item5 | 34 | NOS |
7 | 1.06 | Supply , erection,tesing and commissioing of Step light fixture for landscape area in kunnara park including min 15 W LED integrated mode. Built in 4 KVA surge protection device. The light fixture shall be provided with connectors for loop-in loop-out arrangement. The light fixture shall be made of aluminium and toughened glass protector . The LED luminaire shall meet the following details.\nSystem Lumens: Min 100 lumens for 15 W, Luminaire Efficacy: 10 Lumen/Watt or above , CCT: 3000K, CRI: 70,a driver with surge protection of 4 kv, THD<=15%, PF:>=0.95, Life Span: 50000 Hrs, Degree of Protection for LED module and Driver shall be minimum IP65 rating . | item6 | 27 | NOS |
8 | 1.07 | Supply ,installation,testing and commissioning of 3 Phase 4 Way DB (outdoor type,IP 54)with suitable MCB with timer and contactor. | item7 | 5 | NOS |
9 | 1.08 | Making loop in loop out connection at connection terminals provided in street light pole for 4c 16 sqmm PVC sheathed/XLPE aluminium conductor cable of 1.1kv grade with all accessories required. | item8 | 472 | NOS |
10 | 1.09 | Supply and erection of KSEBL approved make LT energy meter with metering kiosk. | item9 | 5 | NOS |
11 | 1.1 | Supply,laying of XLPE insulated armoured cable with aluminium conductor size 4C 16 sq. mm for working voltage up to 1100v confirming to IS specification in the cable through supply,laying of 40mm dia /4KG pressure PN4 HDPE pipe ISI marked along with all accessories like socket, bend,couplers etc. conforming to IS 14930,Part II complete with fitting and cutting , jointing including cost of material and labour for excavation and laying backfilling and favour block restoration etc.Complete as required. | item10 | 4750 | MTR |
12 | 1.11 | Supply, installation,Testing and commissioning of copper bonded pressed pipe filling with conductive & anti-corrosive minerals 48mm dia,1200mm long, 100 micron with 10Kg Highly conductive carbon based backfill compound suitable for areas with soil resisitivity(dry/rock area) complete including cost of all materials,labour and transportation as per standards and directions of officers.(Refer annexure-VI for drawing) | item11 | 236 | NOS |
13 | 1.12 | Wiring for light/fan point/exhaust fan point/exhaust fan point/call bell point with 1.5sqmm FRLS PVC insulated copper conductor single core cable insurface/recessed medium class PVC conduit,with modular switch,modular plate,suitable GI box and earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc as required Group C | item12 | 50 | NOS |