Military Engineer Services-MES has published Repair/Replacement/Maintenance Of Lt Cable , Lt Panels/Control Ears/Glowsign Boards , Paintingof Electrical Machineries/Transformers At Zakhama And Refrigerators , Acs , Deep Freezer , Voltage Stablizer And Geyser At Chakabama Mil Stn. Submission Date for this Tender is 03-12-2020. Voltage Stabiliser Tenders in ZAKHAMA AND CHAKABAMA Nagaland. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 26-Nov-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-12-2020 |
Name of Work : REPAIR/REPLACEMENT/MAINT OF LT CABLE, LT PANELS/CONTROLGEARS/GLOWSIGN BOARDS,PAINTING OF ELECTRICAL MACHINERIES/TRANSFORMERS AT ZAKHAMA AND REFRIGERATORS,ACs, DEEP FREEZER,VOLTAGE STABLIZER AND GEYSER AT CHAKABAMA MIL STN | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Unit | |
1 | 1 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil. complete all as specified and directed. | 100 | Cum | |
2 | 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed. | 68 | Cum | |
3 | 3 | Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. | 2 | Cum | |
4 | 4 | M & L for sand cushioning with fine dry unwashed sand in trenches for protection of cableswith cable duct complete all as specified and directed. | 30 | Cum | |
5 | 5 | S&F XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) of 16 sqmm 2 core with aluminium conductor, 1100 volts, grade cross sectional area laid in trenches / ducts / pipe or on poles complete all as specified and directed. | 150 | RM | |
6 | 6 | S&F in repair for XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) of 95sqmm 3.5 core with aluminium conductor, 1100 volts, grade cross sectional area laid in trenches / ducts / pipe or on poles complete all as specified and directed. | 45 | RM | |
7 | 7 | S&F in repair for XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) of 240 sqmm 3.5 core with aluminium conductor, 1100 volts, grade cross sectional area laid in trenches / ducts / pipe or on poles complete all as specified and directed. | 25 | RM | |
8 | 8 | S&F for P.C.C Cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm with gaps not exceeding 10mm complete all as specified and directed. | 600 | Each | |
9 | 9 | M&L in repair for Earthing complete with copper earth plate electrode 60cmx60cmx3.15mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to copper strip of size 20 x 3mm by means of nuts, bolts, check nuts & washers made of galvanized iron or steel and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 pre-cast RCC cover slab 30cmx30cmx10cm with one handle for lifting made out of 8mm dia MS bar, watering pipe 20mm bore galvanized iron pipe (medium grade) with MS funnel for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in hard/dense soil complete all other accessories as shown on electrical plate No 5 of MES Sch Pt-I all as specified and directed by Engr in Charge. | 1 | Each | |
10 | 10 | S & F in repair LED street light 45 watts pressure dia cast aluminium IP 66 roadway luminaire with power LEDs as light source and electronic driver including taking out the U/S light and complete all as specified and directed..Make- Havells,ordering code LHETAXU7PN6J045 or equivalent make of Bajaj/Philips | 12 | Each | |
11 | 11 | S&F in repair LED bollard with opal acrylic diffuser and IP 65 protection , makee -Bajaj Model BGBOM 650 9W LED or as equivalent and complete all as specified and directed. Note : The rates are inclusive of required PCC foundation , 4sqmm 2C + 1.5 Sqmm siingle core as earthwire incl 20 mm dia PVC conduit pipe and earth work not more than 10 mtr length between two fittings. | 2 | Each | |
12 | 12 | S & F in repair AC voltmeter of range 0- 500V, 415 Volt, 50 Hz alongwith making all electrical connections by using suitable size of copper wire in between CT coil and meter complete all as specified and directed. | 2 | Each | |
13 | 13 | S & F in repair AC Ammeter of range 0- 200 A, 415 Volt, 50 Hz with & including 01 set (3 Nos) of CT of ratio 200/5 insulated ring type alongwith making all electrical connections by using suitable size of copper wire in between CT coil and meter complete all as specified and directed. | 2 | Each | |
14 | 14 | S & F selector switch for Voltmeter rotary type RY, YB,RB, complete all as specified and directed. | 2 | Each | |
15 | 15 | S & F selector switch for ammeter rotary type R, Y,B, complete all as specified and directed. | 2 | Each | |
16 | 16 | Taking up or down 80 mm bore steel tubing and connections, including cleaning for refixing or removal complete all as specified and directed. | 10 | Each | |
17 | 17 | M&L for Tubes, 'light grade' 80 mm bore galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors for cable protection complete all as specified and directed. | 10 | RM | |
18 | 18 | Taking up or down 50 mm bore steel tubing and connections, including cleaning for refixing or removal, complete all as specified and directed. | 10 | Each | |
19 | 19 | M&L for Tubes, 'light grade' 50 mm bore galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors for cable protection, complete all as specified and directed. | 10 | RM | |
20 | 20 | S&F in repair LED security light Driver kit suitable for 25-40 Watt LED security light (havells endura series) to make U/S light to serviceable complete all as specified and directed. | 20 | Each | |
21 | 21 | S&F in repair MCCB TPN, 415V, 160 Amps with min. breaking capacity 16 KA and complete all as specified and directed. | 1 | Each | |
22 | 22 | S&F in repair MCCB 4pole, 415V, 63 Amps with breaking capacity 16 KA and complete all as directed. | 1 | Each | |
23 | 23 | M & L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. | 5 | Cum | |
24 | 24 | M&L for preparation old surface and applying two coats of synthetic enamel paint of colour as directed over the electrical machinaries Transformers, VCBs, Panels, Stablizers etc after scraping old damaged painting using spray machines or manually complete all as specified and directed. | 300 | Sqm | |
25 | 25 | M&L for Bracket made of 32 mm dia GI pipe (light grade) 1.20 meter long, bent to shape as required on the pole and supporting of MS clamp made of flate iron of size 32 x 5 mm including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size including two coat of synthetic enamel aluminium paint complete all as specified and directed. | 12 | Each | |
26 | 26 | S & F MS Clamp made out of flat iron size 40 x5 mm of suitable size fixed with nuts bolts and washers etc including two coat of synthetic enamel paint over one coat of red oxide primer for fixing of bracket in pole complete incl taking down complete all as specified and directed. | 12 | Each set | |
27 | 27 | M&L for manufacture, supply and installation of the Back lit Glow sign board as per following Specifications:-:\n(a) Box:\n1 The box size is approx 09 x 2 feet.\n2 The board frame should be made of MS Pipe 25x25x1.5 mm painted with one coat red oxide primer and 2 coat synthetic enamel paint.\n3 Top, Bottom and Side cover shall be made of 26 SWG GI sheet with powder coating and Back side of the board shall be covered with 26 SWG plain GI sheet fixed with rivet and screws.\n(b) Lighting/Illumination:\n1. Minimum one LED tube light set is to be provided per Six Square feet of board area.\n2. Complete tube light set is to be provided. Tube lights shall be of reputed make.\n3. Only copper wiring will be used.\n(c) Flex:1\n1. Backlit Flex should be of LG Hi-Flex.\n2. Writing work etc. should be digitally printed. Printing details will be provided by the department.\n(d) Installation:\n1 No separate installation charge will be given. Glow Sign Boards are required to be installed at frong Floor Level of power house/pump house/ office complex etc..\n2 Installation shall be done using MS Fabrication (Brackets, Flats etc.). \n\n | 3 | Each | |
28 | 28 | Taking down unserviceable Air-Conditioner split Type of any capacity and make from its existing location by disconnecting electrical lines for maintenance/servicing/ overhauling and dismantling the same for repair/ replacement of unserviceable parts, cleaning , taking out sludge from inner parts and washing wih cleaning solution and reassembling and refixing the same in its original location /position , connecting all electrical connection and testing complete all as specified and directed by Engineer-in-charge.\n(Note : (a) New parts shall be measured and paid separately under "Supply only" rates here-in-after. \n(b) Minor Part if any , not mentioned in the schedule but required for smooth functionng of split type AC are deemed to be included in the unit rate of the item. | 2 | Each Job | |
29 | 29 | Supply only hermetically/rotary type sealed compressor suitable for 1.5 TR (4500 KCAL/hr) split type Air conditioner complete all as specified and directed..(Note : Compressor oil for initial charging will be measured and paid separately). | 1 | Each | |
30 | 30 | Supply only starting capacitor, paper impregnated of capacity 80/100 mfd AC 240 volts (for 1.5 Ton AC). (Make-Univarshal/sarada/power) | 1 | Each | |
31 | 31 | Supply only running capacitor, paper impregnated di-electric type of capacity 36-45 mfd AC 240 volt, complete all as specified and directed.(Make : Univarshal/sarada/power) | 2 | Each | |
32 | 32 | Supply only thermostat switch to match with the existing Air conditioner of capacity 1.5 Ton , complete all as specified and directed. (Make : Infoss/Ranutrol) | 2 | Each | |
33 | 33 | Supply only over load protector AC 230 volt single phase for 1.5TR AC (Make : Ranutrol/Sriram). | 2 | Each | |
34 | 34 | Supply and charging of compressor oil, complete all as specified and directed. Make: Freezol/bajaj (Capila-D) | 3 | Ltr | |
35 | 35 | Supply only PCB (electronic control circuit board) of split type AC 1.5 TR capacity of (make:- carrier/voltas), complete all as specified and directed. | 2 | Each | |
36 | 36 | Taking out worn-out suction/discharge copper tube for Air-Conditioner and supply and fixing of new copper tube of appropriate quality and size to match in existing including jointing, brazing and testing,suitable for split type ACs of 1.5 TR capacity. complete all as specified and as directed | 6 | RM | |
37 | 37 | Dismantling of unserviceable fan motor from the Air conditioner of 1.5 Ton capacity and re-winding of fan motor with existing gauge of super enameled copper conductor to match with the existing design including heat varnishing, overhauling, testing and re-fixing complete all as specified and as directed. | 2 | Each Job | |
38 | 38 | Supply and charging of refrigerant R-22 after vaccumaziming the system thoroughly, sealing and leak testing complete all as specified and as directed. | 5 | Kg | |
39 | 39 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps capacity SP, complete all as specified and as directed. | 3 | Each | |
40 | 40 | Taking down parts of Refrigerator of any capacity and make from its existing location by disconnecting and sealing all electrical lines for maintenance/servicing/ overhauling and dismantling the same for repair/ replacement of unserviceable parts, cleaning , taking out sludge from inner parts and washing wih cleaning solution and reassembling and refixing the same in its original location /position , connecting all electrical connection and testing complete all as specified and directed.\nNote : (a) New parts shall be measured and paid separately under "Supply only" rates here-in-after.\n(b) Minor Part if any , not mentioned in the schedule but required for smooth functionng of Refrigerator are deemed to be included in the unit rate of the item. | 5 | Each Job | |
41 | 41 | Supply only hermatically sealed compressor for refrigerator of capacity. Upto 310 Ltrs , complete all as specified and as directed. | 2 | Each | |
42 | 42 | Supply only open type relay as per existing one upto 310 Ltr capacity refrigerator. complete all as specified and as directed. | 3 | Each | |
43 | 43 | Supply only thermostat switch to match with the existing item suitable for refrigerator of any capacity. complete all as specified and as directed. | 3 | Each | |
44 | 44 | Supply only over load protector suitable for refrigerator to match with the existing design. complete all as specified and as directed. | 2 | Each | |
45 | 45 | Taking down parts of Deep freezer of any capacity and make from its existing location by disconnecting and sealing all electrical lines for maintenance/servicing/ overhauling and dismantling the same for repair/ replacement of unserviceable parts, cleaning , taking out sludge from inner parts and washing wih cleaning solution and reassembling and refixing the same in its original location /position , connecting all electrical connection and testing complete all as specified and directed by Engineer-in-charge.\nNote : (a) New parts shall be measured and paid separately under "Supply only" rates here-in-after.\n(b) Minor Part if any , not mentioned in the schedule but required for smooth functionng of Refrigerator are deemed to be included in the unit rate of the item. | 3 | Each Job | |
46 | 46 | Supply only hermatically sealed compressor for Deep freezer of capacity. Upto 425 Ltrs , complete all as specified and as directed. | 1 | Each | |
47 | 47 | Supply only open type relay as per existing one upto 310 Ltr capacity Deep freezer, complete all as specified and as directed. | 2 | Each | |
48 | 48 | Supply only thermostat switch to match with the existing item suitable for Deep freezer of any capacity. complete all as specified and as directed. | 3 | Each | |
49 | 49 | Supply only over load protector suitable for Deep freezer to match with the existing design. complete all as specified and as directed. | 2 | Each | |
50 | 50 | Taking down voltage stablizer and removing of burnt coil winding with new super enammeled copper winding as per existing gauge including varnishing drying alongwith replacement of unsv minor spares parts of voltage stablizer complete upto rating of 05 KVA reassembling complete all as speciied and directed. | 2 | Each | |
51 | 51 | Taking down unserviceable Geysers of any capacity from its location by disconnecting and sealing all electrical and water lines for painting/maintenance/servicing/overhauling , opening the same for repair/ replacement of unserviceable parts, including cleaning , taking out sludge from inner tank and washing wih cleaning solution and reassembling and refixing the same in its original location /position , connecting all electrical and water connection and testing complete all as specified and directed.\nNote : (a) New parts shall be measured and paid separately under "Supply only" rates here-in-after.\n(b) Minor Part if any , not mentioned in the schedule but required for smooth functionng of geyser are deemed to be included in the unit rate of the item. | 20 | Each Job | |
52 | 52 | Supply only autocut thermostate of any type suitable for 25/50 Ltr capacity Geyser. complete all as specified and as directed. (Make- Venus/Bajaj/Racold/Remson) | 15 | Each | |
53 | 53 | Supply only heating element 1500/2000 Watts with round/triangular base, push and clamp fixing type suitable for 25/50 Ltrs capacity geysers. complete all as specified and as directed. (Make- Venus/Bajaj/Racold/Remson) | 17 | Each | |
54 | 54 | Supply only indicator lamp (Red/ green) of any shape/ size as per existing pattern suitable for geysers of any capacity, complete all as specified and as directed. | 9 | Each | |
55 | 55 | Supply only PVC steel braided inlet & outlet connection pipe, 15 mm bore, 450 mm long with chromium plated check nuts & washers, complete all as specified and as directed. | 16 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy