Supply And Installation Of Modern Scientific And Electronic Instruments For Operation Of Telengiri Dam Instrumentation Of Dam, Ranigada-Odisha

Water Resources Department-WRD has published Supply And Installation Of Modern Scientific And Electronic Instruments For Operation Of Telengiri Dam Instrumentation Of Dam. Submission Date for this Tender is 21-11-2020. Storage Chests and Cabinets and Trunks Tenders in Ranigada Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

25901966
Supply And Installation Of Modern Scientific And Electronic Instruments For Operation Of Telengiri Dam Instrumentation Of Dam
Open Tender
Indian
Odisha
Ranigada
21-11-2020

Tender Details

Supply And Installation Of Modern Scientific And Electronic Instruments For Operation Of Telengiri Dam Instrumentation Of Dam - 1 Providing, Fixing, Testing & Commissioning Electro Digital Water Level Recorder ( Laser Technology With Sms Facility ) Tag To Server Installed At Dam Safety Office, Bhubaneswar With Following Instruments And Structures For Level And Storage Measurement In Reservoir And Opening Depth / Discharge Measurements From Telengiri Dam, Providing Training To The Field Staff Including Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. 2 M.S. Structure: - Providing, Fabricating & Fixing M.S. Structure Of Required Length To Suit The Site Protected From Reservoir At Top Of The Dam, Made Of 50 Mm X 50 Mm X 6 Mm M.S. Angle Frame Fixed At Dam Front And At Every 0.5 Meter Distance, Fitting In Power Fastener, Painting With Three Coats Of Epoxy Anticorrosive Paint Including Providing & Fixing Pvc Pipe Of 6 Diameter As Per Site Condition From Dam Fsl To Required Lowest Level Of Water Etc; All Complete As Directed By The Engineer-In-Charge. 3 M.S. Platform: - Providing, Fabricating & Fixing M.S. Platform Of Size 1.25 Meter X 1.25 Meter, Fixed In Power Fasteners, Painting With Two Coats Of Epoxy Paint, M.S. Chequered Sheet For Base Plate Including Installation Of Frp Cabinet And Laser Unit Box, M.S. Railing From Three Sides Etc; All Complete As Directed By The Engineer-In-Charge. N 4 Electroray Unit:- Providing & Fixing Electroray Unit With Laser Beam Mounted On M.S. Plate, Provision For Adjustment In Both Axis, Foundation Frame Of 40 Mm X 6 Mm Strip Foundation Bolts, Frp Float For Buoyantly Thrust, Powder Coating, Electronic Sensor Holding Mechanism Mounted In Base Plate And Covered With Frp Security Plate And Security Box With Key & Lock Arrangement, Capacity Measurement For Water Head Zero To 100 Meters Etc; All Complete As Directed By The Engineer-In-Charge. 5 Programme Unit:- Supply Of Data Storage Unit Built In Ip 65 Cabinet From Environment Protection With 64 Kbe2 From Data Storage Memory, Transfer Port With Electronic Cartridge [ Dongle ] For Powerless Automatic Data Transmission And / Or Instant Data Transmission [ Like Blue Tooth ] , 6V Lithium-Ion Battery For Life More Than 15 Months, Two Lines Display, Time Stamping At Ten Different Modes, Maxim Rs 485 / 422 Line Drivers With High Esd Protection For Rs 485 / 422 Communications, Microcontroller Internal 13 Bit Khz Watch Crystal, Two Lines Lcd Display On Mains Supply, Wireless Data Transmission Port Etc; All Complete As Directed By The Engineer-In-Charge. 6 Frp Cabinet:- Supply And Installation Of Fiberglass Reinforced Plastic ( Frp ) Cabin Of Size 1.20 Meter X 1.20 Meter X 2.10 Meter, Both Side Finish, One Side Door And Sliding Aluminum Windows, Frp Roof At Top Of Cabin, Installation On M.S. Platform Etc; Complete As Directed By The Engineer-In-Charge. 7 Software :- Supply Of Dl-Meter Software ( Version 2.0 ) & Loading On Computer For Following Analysis: A )      Log-In Operation B )     Administration Menu C )      System Information About Name Of Govt., Organization, Office, Place, Signing Authority Etc. D )     Master Menu Content For Relative Head E )      Measuring Station Configurations About Ms Code, Consumer Code, Name, Jurisdiction, Location, Sample, Interval Etc. F )      View Station Settings G )     Transactions For Data Capture, Head Content Table Etc. H )      Reports For List Of Measuring Station, Authorized Users, Daily / Fortnightly / Monthly Schedule Time Interval History Etc. I )       Charts Numerical And Graphical For Monthly / Yearly Head / Content Consumption Distribution Etc. J )       Help For Operation And Maintenance Of System. 8 Fixing & Commissioning Of Dl-Meter Unit And Programme Unit On Pvc Pipe, Foundation Template, Nut-Bolts And Cabinet In Line & Level Completed Item As Directed By The Engineer-In-Charge. 9 Testing & Training For Dl-Meter To Field Staff And Operator For Handling Troubleshooting, Data Transmission, Software Operation Etc; Complete As Directed By The Engineer-In-Charge. 10 Providing And Fixing Fencing To Recorder Cabin For Extra Protection Including 50 Mm X 50 Mm X 6 Mm M.S. Angle Structure Covered With M.S. Mesh Of Size 2.5 Cm X 2.5 Cm With Two Coats Of Anticorrosive Epoxy Painting Etc; All Complete As Directed By The Engineer-In-Charge. 11 Inverter :- Supplying, Fixing, Testing And Commissioning Inverter For Power Back Up To Recorder, Luminous Brand 12 V 500 W Capacity Operating On Mains On Solar Energy With Auto On / Off Switch Over With M. S. Bracket Luminous Brand Lithium Battery Of Capacity 150 Ah Lpt 12150 Htt With Power Connection, Battery Stand, Brackets, Wooden Planks & Rubber Sheets, Led Candle Light Of 5 Watt Bulb, Cover With Packing, Forwarding, Transportation And Installation At Site With All Electrical Fittings, Cable, Switches, Plugs For Battery & Inverter, Recorder And Light Including Testing & Training To Field Staff Etc; All Complete As Directed By The Engineer-In-Charge. 12 Providing & Fixing V-Notch ( 15 Ltr. / Sec ) Made Of Glass Fibre Improved “Venturi” Plate Conforming To Is: 9108 For Accurate Measurement Of Water Flowing Through Channels Comprising Of Masonry Construction Provided With Pre-Fabricated Glass Fibre Lining On Both Sides, A Side Chamber Provided In One Side Masonry Wall Of The Said V-Notch On The Upstream Side, A Pipe Provided At The Bottom Of The Chamber Connecting The Said Chamber With The Water Flowing Through The Flume, A Float Means Provided In The Said Chamber, Enabling Recording The Rising Or Falling Level Of Water In The Said Chamber Such As A Scale Provided In The Said Chamber, Moulded Engraved Gauge Marking In Lit / Sec And Also In Centimeter Including Moulded And Engraved Discharge Table, Capacity Marking, Flow Direction, Manufacturer Name And M.S Pipe Stiffeners, Hold Fasts, Sand Treatment On The Backside Of Plate Etc; Complete Including Concrete Foundation 2.0 M ( L ) X 0.50 M ( W ) X 0.15M ( D ) With Verticlal Concrete Wall Behind V-Notch Of Thickness 0.10 M And Transition Wall For Up-Stream & Down-Stream For 25 M Length With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. 13 Providing & Fixing Polymer Composite Improved Calibration Marks With Contact Moulding Process, Both Side Finish, M.S. Strip Embedded Inside, Engraved And Molded Marking For Bands And Figures Covered With Radium And Covered With Two Coats Of Polyurethane For Surface Protection With Marking Of Reduced Levels, Sill, Fsl, Frl, Mwl Etc; With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. 14 Providing & Fixing Polymer Composite Improved Calibration Marks With Contact Moulding Process, Both Side Finish, M.S. Strip Embedded Inside, Engraved And Moulded Marking For Bands And Figures Covered With Radium And Covered With Two Coats Of Polyurethane For Surface Protection With Engraved Marking Of Salient Features, Chainages, Numbers And Instructions In Eye Pleasant Colour Combinations As Per Demand For Given Size And Location Including M.S. Frame And Concrete Work With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge ( For Salient Feature Board / Chainage Board / Instruction Board / Data Board Etc. ) 15 Providing, Fixing, Testing And Commissioning Of Vibrating Wire Type Standard Piezometer Of Following Specification To Measure Ground Water Pressure Along With Required Accessories Including Drilling, Boring, Pipe And All Other Statutory Charges Etc; As Per Requirement With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge But Excluding Periodical Read Out Unit & Stop Watch. Specification: *Standard Range : 5-200Ksc *Over Range : 2 X Rated Pressure *Sensitivity : 0.1 % F.S. *Accuracy + / - 0.5 % F.S> * Temp. Range -20ºc To +70º C *Length X Diameter ( 140 Mm X 20 Mm ) / ( 194 Mm X 25.4 Mm ) / ( 140 Mm X 25.4 Mm ) 16 Supplying Periodical Read Out Unit For Piezometer Complete Set With Required Software, Specification And Commissioning With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. Vibrating Wire Read Out Box Shall Be Portable Unit Designed For The Read Out Of All Vibrating Wire Gages And Transducers And Shall Be Capable Of Displaying The Reading In Digits, Frequency ( Hz ) , Period ( Us ) , Or Microstrain ( Μ£ ) . The Read Out Shall Also Display The Temperature Of The Transduer ( Embedded Thermistor ) With A Resolution Of 0.1°C. All Readings Shall Be Transmitted To A Host Computer And Imported Into Spread Sheet And Database Applications. Suitable For All Vibrating Wire Pp Meter To Take The Data From Sensors Directly In Engineering Units. The Unit Shall Store 750 Data With Date & Time And With Rs 232 / Rj45 Port ( Wi-Fi Optional ) To Down Load The Data In A Pc. The Unit Shall Be Rechargeable Battery Operated . Specifications : * Excitation Range : 5 Volt Square Wave * Measuring Resolution: 0.5 Ms. * Memorry: 64K Eprom * Reading Storage : 750 Data In Engineering Mode 17 Supplying & Fixing Digital Display Portable Isi Marked Stop Watch With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. 18 Supplying & Fixing High Resonance Cc Tv Camera System, Gorilla Type, With 8 Ch 4 K Net Work Video Recorder, 8 Channel Ip Camera Input, H.265 / H.264 Dual Video Formats, Support 4 K Resolution Up To 8 Mp Recording, 80 Mbps Incoming / Outgoing Bandwidth, Support 1Sata Hdds Up To 8Tb, 3Usb Ports, Support Multi-Brand Network Cameras, Mobile Software: Android, Ios, Cms Software : Ivms Etc; With Following Accessories With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge 19 Cp Plus 8 Ch Nvr 2Sata 20 Cp Plus 2 Mp Ip Ptz ( Moving Camera ) 21 Cp Plus 3 Mp Ip Motorised Verry Focal ( Fixed Camera ) 22 8 Port Poe Switch 23 Survilance Hdd 4 Tb 24 Point To Point Antena 25 Cat 6 Cable 26 Rj 45 Clips 27 Metal Box At Each Camera & Antena 28 Power Point At Each Camera 29 Pole At Each Camera 30 Display Unit And Installation Charges 31 Providing, Fixing, Testing, Training And Commissioning Total Weather Station Tag To Server With Sms Facility Installed At Dam Safety Office, Bhubaneswar With Gsm Interface Metrological Station, Imd Approved Monitoring Of Hourly Data Of Temperature, Humidity, Wind Velocity And Rain Gauge Of Data Transfer Through Sms For Ten Mobile Numbers, Gsm Recharge By Department And Memory Card And Tag To Code Analyser. Server With Software, Mounting Tripod 3 Meter, Earthling Kit, Usb Weather Link With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. Parameters : In Sms A ) Location, Date, Time B ) Rainfall In Pre-Decided Time And Cumulative Rain Fall C ) Temperature Minimum And Maximum In A Day D ) Relative Humidity Minimum And Maximum In A Day E ) Wind Speed Minimum And Maximum In A Day F ) Wind Direction At Pre-Decided Time 32 Providing & Fixing Joint Meter Of Following Specification With All Required Accessories Including Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. A ) Range: 0 - 50 Mm. B ) Accuracy : + / - 0.5 % Fs. C ) Resolution: 0.05 Mm. D ) Emp Limit: 10 To 70 Deg C. E ) Thermister: Ysi-44005 Or Equivalent. Material: Stainless Steel F ) Materials: Stainless Steel ( To Be Installed Between Block No. 2 & 3; 4 Nos. At Each Block Joint To Monitor The Joint Opening ) 33 Providing & Fixing Ph Meter ( Portable ) 3 1 / 2 Digit Lcd Display In Abs Plastic Body With Touch Switches And Combination Ph Electrode Of Following Salient Features With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. A ) Measurers Ph, Mv And Temperature 5 Point Calibration. B ) 16 X 2 Line Alphanumeric Lcd With Backlit. C ) Auto Buffer Recognition Facility. D ) Storage Up To 1000 Samples. E ) Attachment For Centronics Dot Matrix Printer 34 Supply, Installation & Monitoring Of Seismograph Of Following Specification & Parameters From Sl. No. 10.1 To 10.9 Below With Cost, Conveyance, Labour Charges, Tools & Plants, Taxes ( Excluding Gst ) Etc; All Complete As Per Relevant Specification & Direction Of The Engineer-In-Charge. 35 * Performance Tested By University Of Technology Sydney, University Of Melbourne, Ce Certified. * Records Triaxial Data From Integrated Seismometer Continuously To Sd Card Storage. * Fault Detection - Sd Card Full / Error, Power, Temperature * Real-Time Alarm Output To Relay Circuit During Earthquake * Internal Battery Available ( Optional ) . * Designed For Minimum 10 Years Operation. Kelunji Prism Used In Structural Monitoring Have Operated For Over 20 Years, Producing An Aggregate Mtbf Of Greater Than 5 Years 36 Recorder: * Type : 32-Bit Adc * Data Channels : Three, Synchronously Sampled * Full-Scale Signal ( Standard ) 40 Vpp ( Voltas Peak-To-Peak ) * Sensitivity ( Standard ) 419430.4 Counts Per Volt * Preamplifier Gains Available ( User Selectable ) X1, X2, X4, X8, X16, X32, X64, X128, X256. * Frequency Reasonse Dc To 2000 Hz Sampling Rates Available ( Samples Per Second ) 40, 100, 200, 250, 400, 500, 800, 1000, 1600, 2000 37 Sensor: * Type : Velocity * Data Channels : Triaxial ( East-West, North-South, Up-Down ) . * Sensitivity : 868 V / M / S. * Noise Performance Below Nlnm Between 2 And 9 Second Period, Freqency Response 30 Second Period To 80 Hz. 38 Timing: * Reference Time Stamp With Every Pps ( Pulse Per Second ) From Gps Receiver Accuracy: Rms 30 Nano Seconds. 39 Recording: *File Recording Options: Continuous ( Always On ) * Trigger / Alarm: Algorithms Sta / Lta ( Any / All Channels ) , Level ( Any / All Channels ) , System ( Voltage, Memory, Temperature ) . * Storage Memory Type : Sd Card ( Sdhc Or Micro Sd Using Adaptor. Included Storage 32 Gb ) . * Continuous Triaxial Recording Capacity @ 100 Sps Over 1 Year Of Data Stored In A Ring Buffer ( Oldest Data Over Written When Full ) . * File System Format: Fat32, Readable By Windows, Mac & Linux Operating Systems * Data Format: Mini Seed ( With Companion Text Files Containing Station Data ) 40 Power: * Dc Charger Voltage Input Range 10-36 Vdc. * Consumption ( When Recording Continuous Data ) 1.1W * Runtime On Internal 12 V Battery 12 + Hours 41 Physical: * Housing Cnc Milled From Solid Alumimum, Hard Anodized. * Dust And Water Ingression Protection: Ip 67. * Operating Temperature Range ( Up To 100% R / H ) - 20 Deg. C To + 70 Deg. C * Size ( Excluding Connectors ) Ø 135Mm, 225Mm High * Weight ( Standard, With Internal Battery ) 3.1 Kg. 42 User Interface: * Configuraton Interface In-Built Lcd With 4-Line Text Display And 4- Button Input * Data Telemetry Ip Streaming Over Optional Ethernet Adaptor Or 3G Cellular Modem * Remote Set Up And Communications Via Live Stream Application Or Eqserver Web Interface 43 Connectors & Cables: * Power 2 Pin Circular Push / Pull Lock * On-Off Switch : External Push Button * Power Cable 2 M Length With Bare Wire Ends

Key Value

Document Fees
INR 10000 /-
EMD
INR 52800.0 /-
Tender Value
INR 52.74 Lakhs /-

BOQ Items

Name of Work: Supply and Installation of Modern Scientific & Electronic Instruments for Operation of Telengiri Dam
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Providing, fixing, testing & commissioning Electro Digital Water Level Recorder (Laser Technology with SMS facility) tag to server installed at Dam Safety Office, Bhubaneswar with following instruments and structures for level and storage measurement in reservoir and opening depth / discharge measurements from Telengiri Dam, providing training to the field staff including cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge.
2 1.01 M.S. Structure: - Providing, fabricating & fixing M.S. structure of required length to suit the site protected from reservoir at top of the dam, made of 50 mm x 50 mm x 6 mm M.S. angle frame fixed at dam front and at every 0.5 meter distance, fitting in power fastener, painting with three coats of epoxy anticorrosive paint including providing & fixing PVC pipe of 6 " diameter as per site condition from dam FSL to required lowest level of water etc; all complete as directed by the Engineer-in-charge. BI01010001010000000000000515BI0100001113 1 Each
3 1.02 M.S. Platform: - Providing, fabricating & fixing M.S. platform of size 1.25 meter x 1.25 meter, fixed in power fasteners, painting with two coats of epoxy paint, M.S. chequered sheet for base plate including installation of FRP cabinet and laser unit box, M.S. railing from three sides etc; all complete as directed by the Engineer-in-charge.\n BI01010001010000000000000515BI0100001114 1 Each
4 1.03 Electroray Unit:- Providing & fixing Electroray Unit with laser beam mounted on M.S. plate, provision for adjustment in both axis, foundation frame of 40 mm x 6 mm strip foundation bolts, FRP float for buoyantly thrust, powder coating, electronic sensor holding mechanism mounted in base plate and covered with FRP security plate and security box with key & lock arrangement, capacity measurement for water head zero to 100 meters etc; all complete as directed by the Engineer-in-charge. 1 Each
5 1.04 Programme Unit:- Supply of Data Storage Unit built in IP 65 cabinet from environment protection with 64 Kbe2 from data storage memory, transfer port with electronic cartridge [dongle] for powerless automatic data transmission and/or instant data transmission [like blue tooth], 6V Lithium-ion battery for life more than 15 months, two lines display, time stamping at ten different modes, MAXIM RS 485/422 line drivers with high ESD protection for RS 485/422 communications, microcontroller internal 13 bit KHz watch crystal, two lines LCD display on mains supply, wireless data transmission port etc; all complete as directed by the Engineer-in-charge. 1 Each
6 1.05 FRP Cabinet:- Supply and installation of fiberglass reinforced plastic (FRP) cabin of size 1.20 meter x 1.20 meter x 2.10 meter, both side finish, one side door and sliding aluminum windows, FRP roof at top of cabin, installation on M.S. platform etc; complete as directed by the Engineer-in-charge. 1 Each
7 1.06 Software :- Supply of DL-Meter software (version 2.0) & loading on computer for following analysis: a)     Log-in operation b)    Administration menu c)     System information about name of Govt., organization, office, place, signing authority etc. d)    Master menu content for relative head e)     Measuring station configurations about MS code, consumer code, name, jurisdiction, location, sample, interval etc. f)     View station settings g)    Transactions for data capture, head content table etc. h)     Reports for list of measuring station, authorized users, daily/fortnightly/monthly schedule time interval history etc. i)      Charts numerical and graphical for monthly / yearly head / content consumption distribution etc. j)      Help for operation and maintenance of system. 1 Each
8 1.07 Fixing & commissioning of DL-Meter unit and Programme unit on PVC pipe, foundation template, nut-bolts and cabinet in line & level completed item as directed by the Engineer-in-charge. 1 Each
9 1.08 Testing & training for DL-Meter to field staff and operator for handling troubleshooting, data transmission, software operation etc; complete as directed by the Engineer-in-charge. 1 Each
10 1.09 Providing and fixing fencing to recorder cabin for extra protection including 50 mm x 50 mm x 6 mm M.S. Angle structure covered with M.S. mesh of size 2.5 cm x 2.5 cm with two coats of anticorrosive epoxy painting etc; all complete as directed by the Engineer-in-charge. 1 Each
11 1.1 Inverter :- Supplying, fixing, testing and commissioning Inverter for power back up to recorder, Luminous Brand 12 V 500 W capacity operating on mains on solar energy with Auto ON/OFF switch over with M. S. Bracket Luminous brand Lithium battery of capacity 150 AH LPT 12150 HTT with power connection, battery stand, brackets, wooden planks & rubber sheets, LED candle light of 5 Watt bulb, cover with packing, forwarding, transportation and installation at site with all electrical fittings, cable, switches, plugs for battery & inverter, recorder and light including testing & training to field staff etc; all complete as directed by the Engineer-in-charge. 1 Each
12 2 Providing & fixing V-Notch (15 Ltr./Sec) made of glass fibre improved “Venturi” plate conforming to IS: 9108 for accurate measurement of water flowing through channels comprising of masonry construction provided with pre-fabricated glass fibre lining on both sides, a side chamber provided in one side masonry wall of the said V-Notch on the upstream side, a pipe provided at the bottom of the chamber connecting the said chamber with the water flowing through the flume, a float means provided in the said chamber, enabling recording the rising or falling level of water in the said chamber such as a scale provided in the said chamber, moulded engraved gauge marking in lit/sec and also in centimeter including moulded and engraved discharge table, capacity marking, flow direction, manufacturer name and M.S pipe stiffeners, hold fasts, sand treatment on the backside of plate etc; complete including concrete foundation 2.0 m (L) x 0.50 m (W) x 0.15m (D) with verticlal concrete wall behind V-Notch of thickness 0.10 m and transition wall for up-stream & down-stream for 25 m length with cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge. 3 Each
13 3 Providing & fixing polymer composite improved calibration marks with contact moulding process, both side finish, M.S. strip embedded inside, engraved and molded marking for bands and figures covered with radium and covered with two coats of polyurethane for surface protection with marking of reduced levels, SILL, FSL, FRL, MWL etc; with cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge. 11.88 Sqm
14 4 Providing & fixing polymer composite improved calibration marks with contact moulding process, both side finish, M.S. strip embedded inside, engraved and moulded marking for bands and figures covered with radium and covered with two coats of polyurethane for surface protection with engraved marking of salient features, chainages, numbers and instructions in eye pleasant colour combinations as per demand for given size and location including M.S. frame and concrete work with cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge (For Salient Feature Board/Chainage Board/Instruction Board/ Data Board etc.) 15.3 Sqm
15 5.1 Providing, fixing, testing and commissioning of vibrating wire type standard piezometer of following specification to measure ground water pressure along with required accessories including drilling, boring, pipe and all other statutory charges etc; as per requirement with cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge but excluding Periodical Read Out Unit & Stop Watch. Specification: *Standard Range : 5-200Ksc *Over Range : 2 x rated pressure *Sensitivity : 0.1 % F.S. *Accuracy +/- 0.5 % F.S> * Temp. Range -20ºC to +70º C *Length x Diameter (140 mm x 20 mm) / ( 194 mm x 25.4 mm) / (140 mm x 25.4 mm) 2 Each
16 5.2 Supplying Periodical Read Out Unit for Piezometer complete set with required software, specification and commissioning with cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge. Vibrating Wire Read out Box shall be portable unit designed for the read out of all vibrating wire gages and transducers and shall be capable of displaying the reading in digits, frequency (Hz), period (us), or microstrain (µ£). The read out shall also display the temperature of the transduer (embedded thermistor) with a resolution of 0.1°C. All readings shall be transmitted to a host computer and imported into spread sheet and database applications. Suitable for all vibrating wire PP meter to take the data from sensors directly in engineering units. The unit shall store 750 data with date & time and with RS 232/RJ45 Port (Wi-Fi optional) to down load the data in a PC. The unit shall be rechargeable battery operated . Specifications : * Excitation Range : 5 Volt Square wave * Measuring Resolution: 0.5 ms. * Memorry: 64K EPROM * Reading Storage : 750 data in engineering mode 1 Each
17 5.3 Supplying & fixing Digital Display Portable ISI marked Stop Watch with cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge. 1 Each
18 6 Supplying & fixing High Resonance CC TV Camera system, Gorilla Type, with 8 Ch 4 K net work video recorder, 8 channel IP camera input, H.265/H.264 dual video formats, support 4 K resolution up to 8 MP recording, 80 Mbps incoming/ outgoing bandwidth, support 1SATA HDDs up to 8TB, 3USB ports, support multi-brand network cameras, mobile software: Android, iOS, CMS Software : IVMS etc; with following accessories with cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge
19 6.01 CP PLUS 8 CH NVR 2SATA 1 Each
20 6.02 CP PLUS 2 MP IP PTZ ( Moving camera) 1 Each
21 6.03 CP PLUS 3 MP IP MOTORISED VERRY FOCAL (Fixed camera) 2 Each
22 6.04 8 PORT POE SWITCH 1 Each
23 6.05 SURVILANCE HDD 4 TB 1 Each
24 6.06 POINT TO POINT ANTENA 3 Each
25 6.07 CAT 6 CABLE 2000 Rmt
26 6.08 RJ 45 CLIPS 15 Each
27 6.09 METAL BOX AT EACH CAMERA & ANTENA 8 Each
28 6.1 POWER POINT AT EACH CAMERA 5 Each
29 6.11 POLE AT EACH CAMERA 5 Each
30 6.12 DISPLAY UNIT AND INSTALLATION CHARGES 1 Set
31 7 Providing, fixing, testing, training and commissioning Total Weather Station Tag to Server with SMS facility installed at Dam Safety Office, Bhubaneswar with GSM Interface Metrological Station, IMD Approved monitoring of hourly data of temperature, humidity, wind velocity and rain gauge of data transfer through sms for ten mobile numbers, GSM recharge by Department and memory card and tag to Code Analyser. Server with software, mounting tripod 3 meter, earthling kit, USB weather link with cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge. Parameters : In SMS a) Location, date, time b) Rainfall in pre-decided time and cumulative rain fall c) Temperature Minimum and Maximum in a day d) Relative Humidity Minimum and Maximum in a day e)Wind Speed Minimum and Maximum in a day f) Wind direction at pre-decided time 1 Each
32 8 Providing & fixing Joint Meter of following specification with all required accessories including cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge. a) Range: 0 - 50 mm. b) Accuracy : +/- 0.5 % FS. c) Resolution: 0.05 mm. d) emp limit: 10 to 70 deg C. e) Thermister: YSI-44005 or equivalent. Material: Stainless steel f) Materials: Stainless steel (To be installed between block No. 2 & 3; 4 Nos. at each block joint to monitor the joint opening) 8 Each
33 9 Providing & fixing PH Meter ( Portable) 3 1/2 digit LCD display in ABS plastic body with touch switches and combination PH electrode of following salient features with cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge. a) Measurers PH, MV and Temperature 5 point Calibration. b) 16 x 2 line Alphanumeric LCD with backlit. c) Auto Buffer Recognition Facility. d) Storage Up to 1000 samples. e) Attachment for Centronics Dot Matrix Printer 1 Each
34 10 Supply, installation & monitoring of SEISMOGRAPH of following specification & parameters from Sl. No. 10.1 to 10.9 below with cost, conveyance, labour charges, tools & plants, taxes (Excluding GST) etc; all complete as per relevant specification & direction of the Engineer-in-charge. 1 Each
35 10.1 * Performance tested by University of Technology Sydney, University of Melbourne, CE Certified. * Records triaxial data from integrated seismometer continuously to SD Card Storage. * Fault detection - SD card full / error, power, temperature * Real-time alarm output to relay circuit during earthquake * Internal battery available (Optional). * Designed for minimum 10 years operation. Kelunji PRISM used in structural monitoring have operated for over 20 years, producing an aggregate MTBF of greater than 5 years
36 10.2 Recorder: * Type : 32-bit ADC * Data Channels : Three, Synchronously sampled * Full-scale signal ( Standard) 40 VPP ( Voltas Peak-to-Peak) * Sensitivity ( standard) 419430.4 counts per Volt * Preamplifier gains available ( user selectable ) x1, x2, x4, x8, x16, x32, x64, x128, x256. * Frequency reasonse DC to 2000 Hz sampling rates available (samples per second) 40,100, 200, 250, 400, 500, 800, 1000, 1600, 2000
37 10.3 Sensor: * Type : Velocity * Data Channels : Triaxial ( East-West, North-South, Up-Down). * Sensitivity : 868 V/m/s. * Noise performance below NLNM between 2 and 9 second period, Freqency response 30 second period to 80 Hz.
38 10.4 Timing: * Reference Time stamp with every PPS ( pulse per second) from GPS receiver Accuracy: RMS 30 nano seconds.
39 10.5 Recording: *File recording options: Continuous ( always on) * Trigger/alarm: Algorithms STA/LTA ( Any/all channels), Level (Any / all channels), System (Voltage, memory, temperature ). * Storage memory type : SD Card ( SDHC or micro SD using adaptor. Included storage 32 GB). * Continuous triaxial recording capacity @ 100 sps over 1 year of data stored in a ring buffer (Oldest data over written when full). * File system format: FAT32, readable by Windows, Mac & Linux operating systems * Data format: Mini SEED ( with companion text files containing station data)
40 10.6 Power: * DC charger voltage input range 10-36 VDC. * Consumption ( when recording continuous data) 1.1W * Runtime on internal 12 V battery 12 + hours
41 10.7 Physical: * Housing CNC milled from solid alumimum, hard anodized. * Dust and Water Ingression Protection: IP 67. * Operating Temperature Range ( up to 100% R/H) - 20 deg. C to + 70 deg. C * Size (excluding connectors ) Ø 135mm, 225mm high * Weight ( standard, with internal battery) 3.1 Kg.
42 10.8 User Interface: * Configuraton Interface In-built LCD with 4-line text display and 4- button input * Data Telemetry IP streaming over optional Ethernet adaptor or 3G cellular modem * Remote set up and communications via live stream application or eqserver web interface
43 10.9 Connectors & Cables: * Power 2 Pin Circular Push/Pull Lock * On-Off Switch : External push button * Power cable 2 m length with bare wire ends