Scdd Electrification For Communitty College At Vadakkumcherry In Palakkad District Electrification
Tender Value
Ref. Documents
Estimated cost
Bid Submission
13 Nov 2020
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
vyttila → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Scdd Electrification For Communitty College At Vadakkumcherry In Palakkad District Electrification
BOQ
| Work Name:SCDD –Electrification for Community College at Vadakkanchery in Palakkad District | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | SPECIFICATIONS | BI01010001010000000000000515BI0100001113 | ||
| 2 | 2 | od77792/2020_2021 : Supply and wiring points according to IS 732-1989 using rigid medium gauge PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Single Control light point with 6A, plate ceiling rose - Short point | BI01010001010000000000000515BI0100001114 | 223 | point |
| 3 | 3 | od77793/2020_2021 : Supply and wiring points according to IS 732-1989 using rigid medium gauge PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Twin Control light point with 6A, plate ceiling rose - Short point | BI01010001010000000000000515BI0100001115 | 4 | point |
| 4 | 4 | od77794/2020_2021 : Supply and wiring points according to IS 732-1989 using rigid medium gauge PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls,fixing the conduit concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Single control light point without ceiling rose - Short point | BI01010001010000000000000515BI0100001116 | 180 | point |
| 5 | 5 | od77795/2020_2021 : Supply and wiring points according to IS 732-1989 using rigid PVC medium gauge conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point | BI01010001010000000000000515BI0100001117 | 175 | point |
| 6 | 6 | od77796/2020_2021 : Supply and wiring points according to IS 732-1989 using rigid medium gauge PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Call bell point with 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Short point | BI01010001010000000000000515BI0100001118 | 5 | point |
| 7 | 7 | od77797/2020_2021 : Supply and wiring points according to IS 732-1989 using rigid PVC medium gauge conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, cutting the walls, fixing the conduit concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.50 sq mm green coloured FRLS PVC insulated stranded single core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points | BI01010001010000000000000515BI0100001119 | 12 | point |
| 8 | 8 | od77798/2020_2021 : Supply and wiring points according to IS 732-1989 using rigid PVC medium gauge conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,cutting the walls, fixing the conduit concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with 1.5 sqmm green coloured FRLS PVC insulated stranded single core copper conductor ,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). Independent plug - Short point | BI01010001010000000000000515BI0100001120 | 12 | point |
| 9 | 9 | 1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | BI01010001010000000000000515BI0100001121 | 500 | metre |
| 10 | 10 | 1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm | BI01010001010000000000000515BI0100001122 | 500 | metre |
| 11 | 11 | 1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm | BI01010001010000000000000515BI0100001123 | 200 | metre |
| 12 | 12 | 1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) | BI01010001010000000000000515BI0100001124 | 10 | each |
| 13 | 13 | 1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) | BI01010001010000000000000515BI0100001125 | 36 | each |
| 14 | 14 | 1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) | BI01010001010000000000000515BI0100001126 | 20 | each |
| 15 | 15 | 1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) | BI01010001010000000000000515BI0100001127 | 20 | each |
| 16 | 16 | 1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | BI01010001010000000000000515BI0100001128 | 800 | metre |
| 17 | 17 | 1.17.6 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm | BI01010001010000000000000515BI0100001129 | 300 | metre |
| 18 | 18 | 1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | BI01010001010000000000000515BI0100001130 | 300 | metre |
| 19 | 19 | 1.17.15 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm | BI01010001010000000000000515BI0100001131 | 200 | metre |
| 20 | 20 | 1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm | BI01010001010000000000000515BI0100001132 | 200 | metre |
| 21 | 21 | 1.17.22 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm | BI01010001010000000000000515BI0100001133 | 50 | metre |
| 22 | 22 | 1.17.30 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm | BI01010001010000000000000515BI0100001134 | 300 | metre |
| 23 | 23 | 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch | BI01010001010000000000000515BI0100001135 | 60 | each |
| 24 | 24 | 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch | BI01010001010000000000000515BI0100001136 | 36 | each |
| 25 | 25 | 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet | BI01010001010000000000000515BI0100001137 | 100 | each |
| 26 | 26 | 1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet | BI01010001010000000000000515BI0100001138 | 42 | each |
| 27 | 27 | od77838/2020_2021 : Supply and Fixing 20A DP Switch & accessories in the existing front plates and giving necessary connections as required (Group B) | BI01010001010000000000000515BI0100001139 | 6 | no |
| 28 | 28 | 1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet | BI01010001010000000000000515BI0100001140 | 7 | each |
| 29 | 29 | 1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet | BI01010001010000000000000515BI0100001141 | 2 | each |
| 30 | 30 | 1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. | BI01010001010000000000000515BI0100001142 | 64 | each |
| 31 | 31 | 90.9.2.1 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid | BI01010001010000000000000515BI0100001143 | 60 | metre |
| 32 | 32 | 90.9.2.2 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable devider | BI01010001010000000000000515BI0100001144 | 60 | metre |
| 33 | 33 | 90.9.2.3 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree | BI01010001010000000000000515BI0100001145 | 6 | each |
| 34 | 34 | 90.9.2.4 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree | BI01010001010000000000000515BI0100001146 | 6 | each |
| 35 | 35 | 90.9.2.5 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree | BI01010001010000000000000515BI0100001147 | 6 | each |
| 36 | 36 | 90.9.2.7 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat cross | BI01010001010000000000000515BI0100001148 | 6 | each |
| 37 | 37 | 90.9.2.8 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap | BI01010001010000000000000515BI0100001149 | 12 | each |
| 38 | 38 | 90.9.2.10 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Joint cover | BI01010001010000000000000515BI0100001150 | 6 | each |
| 39 | 39 | 90.9.2.11 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Cable retainer | BI01010001010000000000000515BI0100001151 | 60 | each |
| 40 | 40 | 90.9.2.12 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.1 to 3 module mounting box | BI01010001010000000000000515BI0100001152 | 27 | each |
| 41 | 41 | 90.9.2.13 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.4 to 5 module mounting box | BI01010001010000000000000515BI0100001153 | 27 | each |
| 42 | 42 | od78364/2020_2021 : Supply, testing and installation of Wall Mount 9U x 550 W x 450 D, Front Glass Door with Lock with 2 pairs of 19\" Mounting Rails with accessories 1. 1U Cable Manager - 1 No, 2. Roof Mounted Fan Unit / 90 CFM /230V AC 1 No., 3. 6 Way 5 Amp Power Distribution Unit 1 No and 4. Mounting Hardware 1 pkt. Make - NWR-9U-5045-GR | BI01010001010000000000000515BI0100001154 | 3 | no |
| 43 | 43 | od78366/2020_2021 : Supply, testing and installation of 24 10/100/1000Base-T ports + 4 SFP ports Web Smart Switch Make - D Link DGS-1210-28 | BI01010001010000000000000515BI0100001155 | 3 | no |
| 44 | 44 | od78368/2020_2021 : Supply, testing and installation of Patch panel Cat6 UTP Keystone Type-24port-fully Loaded Make - D Link NPP-C61BLK241 | BI01010001010000000000000515BI0100001156 | 3 | no |
| 45 | 45 | od78370/2020_2021 : Supply, testing and installation of Jack Cat6 Keystone UTP with Collapsible Shutter-White Make - D Link NKJ-C6WHI1B21 | BI01010001010000000000000515BI0100001157 | 60 | no |
| 46 | 46 | od78372/2020_2021 : Supply, testing and installation of Face Plate-Single(Keystone jack,square) Make - D Link NFP-OWHI11 | BI01010001010000000000000515BI0100001158 | 60 | no |
| 47 | 47 | od78374/2020_2021 : Supply, testing and installation of Back Box Make - D Link NBB-011 | BI01010001010000000000000515BI0100001159 | 60 | no |
| 48 | 48 | od78376/2020_2021 : Supply, testing and installation of Cat6 UTP 24AWG PATCH CHORD:1M,Plug 30U'Make - D Link NCB-C6UGRYR1-1 | BI01010001010000000000000515BI0100001160 | 60 | no |
| 49 | 49 | od78378/2020_2021 : Supply, testing and installation of Cat6 UTP 24AWG PATCH CHORD:2M,Plug 30U' Make - D Link NCB-C6UGRYR1-2 | BI01010001010000000000000515BI0100001161 | 60 | no |
| 50 | 50 | od78380/2020_2021 : Supply, testing and installation of Horizontal. Cable Manager-Metal Make - D LInk NCM-XX01-B | BI01010001010000000000000515BI0100001162 | 3 | no |
| 51 | 51 | od78382/2020_2021 : Supplying & drawing Cat 6 UTP 24AWGSolid cable to relevant standards through the existing conduit and giving connections as required | BI01010001010000000000000515BI0100001163 | 1400 | metre |
| 52 | 52 | 1.22.1 : Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.75 mm X 75 mm X 60 mm deep | BI01010001010000000000000515BI0100001164 | 5 | each |
| 53 | 53 | 1.22.4 : Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.150 mm X 150 mm X 60 mm deep | BI01010001010000000000000515BI0100001165 | 2 | each |
| 54 | 54 | 90.5.1.3 : Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell | BI01010001010000000000000515BI0100001166 | 3 | each |
| 55 | 55 | 90.5.1.4 : Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Musical bell with bird sound | BI01010001010000000000000515BI0100001167 | 2 | each |
| 56 | 56 | 90.5.1.8 : Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Gong bell 150mm-without MS box | BI01010001010000000000000515BI0100001168 | 1 | each |
| 57 | 57 | 90.5.1.7 : Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Gong bell 100mm-without MS box | BI01010001010000000000000515BI0100001169 | 1 | each |
| 58 | 58 | 90.3.20.3 : Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture | BI01010001010000000000000515BI0100001170 | 12 | each |
| 59 | 59 | 90.3.21.3 : Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture | BI01010001010000000000000515BI0100001171 | 120 | each |
| 60 | 60 | od77799/2020_2021 : Supply and fixing low glare high efficiency square surface mounted LED flat panel 230V 50Hz 36 w light fitting complete with all required accessories etc. as required | BI01010001010000000000000515BI0100001172 | 60 | no |
| 61 | 61 | od77800/2020_2021 : Supply and fixing low glare high efficiency square surface mounted LED flat panel 230V 50Hz Compton make LCDSPLN-S-18-CDL 18 w light fitting complete with all required accessories etc. as required | BI01010001010000000000000515BI0100001173 | 40 | no |
| 62 | 62 | od77840/2020_2021 : Supply of Decorative LED suspended mounting 2x2 fitting with UGR <19 Suitable for diagonal luminous emittance surface for vertical and horizontal volumetric lighting, 20 % upward light distribution to customizable center plate suitable to keep open or give creative zoning, naming etc, 3600 lumens light output, CRCA Body and Poly carbonate diffuser including suspension kit, 50,000 burning hours, 140-270 v Voltage range and 2.5 KV Surge Protection. The total power consumption of the fitting shall be not more than 43 W | BI01010001010000000000000515BI0100001174 | 28 | each |
| 63 | 63 | 90.15.3.1 : Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete 5 Meters | BI01010001010000000000000515BI0100001175 | 10 | each |
| 64 | 64 | 90.15.4.1 : Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | BI01010001010000000000000515BI0100001176 | 24 | each |
| 65 | 65 | 90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | BI01010001010000000000000515BI0100001177 | 10 | each |
| 66 | 66 | od77801/2020_2021 : Supply , installation, testing and commissioning of 40 w LED Post top lantern with IP 65 protection make Compton LPTO-40-CDL on existing GI post.(gate light) | BI01010001010000000000000515BI0100001178 | 2 | no |
| 67 | 67 | 90.3.17.1 : Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.32 mm dia GI pipe | BI01010001010000000000000515BI0100001179 | 2 | metre |
| 68 | 68 | 90.3.18.1 : Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps | BI01010001010000000000000515BI0100001180 | 48 | metre |
| 69 | 69 | od77802/2020_2021 : Supply and providing outdoor ,water proof junction box suitable to mount MCB as termination box for gate/street light suitably mounted on pillar. | BI01010001010000000000000515BI0100001181 | 12 | no |
| 70 | 70 | od77803/2020_2021 : Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9 W LED light to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required. | BI01010001010000000000000515BI0100001182 | 12 | no |
| 71 | 71 | od77804/2020_2021 : Supply and fixing angle / straight brass lined skirt type, bakelite batten holder with aluminium shade, 9W LED bulb and giving connection etc as required | BI01010001010000000000000515BI0100001183 | 80 | no |
| 72 | 72 | 90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. | BI01010001010000000000000515BI0100001184 | 175 | each |
| 73 | 73 | 90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C | BI01010001010000000000000515BI0100001185 | 175 | each |
| 74 | 74 | 90.4.8 : Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. | BI01010001010000000000000515BI0100001186 | 30 | each |
| 75 | 75 | od77806/2020_2021 : Supply, conveyance, installation, testing and commissioning of 225mm light duty exhaust fan in metal frame in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. | BI01010001010000000000000515BI0100001187 | 19 | no |
| 76 | 76 | od77842/2020_2021 : Supply, conveyance, installation, testing and commissioning of 305 mm, single phase, heavy duty, 1400 rpm exhaust fan in metal frame in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. | BI01010001010000000000000515BI0100001188 | 11 | no |
| 77 | 77 | od77807/2020_2021 : Supply, conveyance, installation, testing and commissioning 400mm sweep wall mounting fan using mounting brackets supplied along with the fan and giving connection with existing wire. | BI01010001010000000000000515BI0100001189 | 1 | no |
| 78 | 78 | 90.14.1.1 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame) | BI01010001010000000000000515BI0100001190 | 16 | sqm |
| 79 | 79 | 90.14.2.5 : Supply and providing 6mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. | BI01010001010000000000000515BI0100001191 | 3 | sqm |
| 80 | 80 | 90.14.3.1 : Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet | BI01010001010000000000000515BI0100001192 | 60 | metre |
| 81 | 81 | 90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC) | BI01010001010000000000000515BI0100001193 | 24 | metre |
| 82 | 82 | 90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required. | BI01010001010000000000000515BI0100001194 | 3000 | Cum cm |
| 83 | 83 | 90.14.7 : Supply and providing copper earth bus in the panel board | BI01010001010000000000000515BI0100001195 | 1000 | Cum cm |
| 84 | 84 | 90.14.10.7 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC | BI01010001010000000000000515BI0100001196 | 1 | no |
| 85 | 85 | od78333/2020_2021 : Carrying out control wiring for panel with normal meters and indication lamps alone with 1.50 sq mm single run 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipment's including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. | BI01010001010000000000000515BI0100001197 | 60 | metre |
| 86 | 86 | 2.1.1 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N | BI01010001010000000000000515BI0100001198 | 17 | each |
| 87 | 87 | 2.1.3 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N | BI01010001010000000000000515BI0100001199 | 2 | each |
| 88 | 88 | 2.1.4 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.125 Amp TP & N | BI01010001010000000000000515BI0100001200 | 1 | each |
| 89 | 89 | od78384/2020_2021 : Three phase multifunction meters to read V, A and F, accuracy class 1(Digital type) | BI01010001010000000000000515BI0100001201 | 1 | no |
| 90 | 90 | od78386/2020_2021 : LED indicators for all voltage ranges - Red, Green, Yellow or Orange Colour | BI01010001010000000000000515BI0100001202 | 3 | no |
| 91 | 91 | 90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43) | BI01010001010000000000000515BI0100001203 | 13 | each |
| 92 | 92 | 90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) | BI01010001010000000000000515BI0100001204 | 2 | each |
| 93 | 93 | 90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) | BI01010001010000000000000515BI0100001205 | 2 | each |
| 94 | 94 | 90.11.1.18 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) | BI01010001010000000000000515BI0100001206 | 1 | each |
| 95 | 95 | 2.3.1 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door | BI01010001010000000000000515BI0100001207 | 1 | each |
| 96 | 96 | 2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door | BI01010001010000000000000515BI0100001208 | 1 | each |
| 97 | 97 | 2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door | BI01010001010000000000000515BI0100001209 | 2 | each |
| 98 | 98 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | BI01010001010000000000000515BI0100001210 | 300 | each |
| 99 | 99 | 2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole | BI01010001010000000000000515BI0100001211 | 8 | each |
| 100 | 100 | 2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral | BI01010001010000000000000515BI0100001212 | 13 | each |
| 101 | 101 | 2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | BI01010001010000000000000515BI0100001213 | 30 | each |
| 102 | 102 | 2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | BI01010001010000000000000515BI0100001214 | 26 | each |
| 103 | 103 | 2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps | BI01010001010000000000000515BI0100001215 | 4 | each |
| 104 | 104 | 2.13.3 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps | BI01010001010000000000000515BI0100001216 | 2 | each |
| 105 | 105 | 2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps | BI01010001010000000000000515BI0100001217 | 2 | each |
| 106 | 106 | 2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps | BI01010001010000000000000515BI0100001218 | 11 | each |
| 107 | 107 | 2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | BI01010001010000000000000515BI0100001219 | 4 | each |
| 108 | 108 | 2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps | BI01010001010000000000000515BI0100001220 | 4 | each |
| 109 | 109 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | BI01010001010000000000000515BI0100001221 | 4 | each |
| 110 | 110 | 2.2.13 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 30 KA 4 Pole | BI01010001010000000000000515BI0100001222 | 1 | cartridge |
| 111 | 111 | 90.14.10.10 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16A -100A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC | BI01010001010000000000000515BI0100001223 | 3 | no |
| 112 | 112 | 90.14.10.11 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC | BI01010001010000000000000515BI0100001224 | 1 | no |
| 113 | 113 | 90.14.10.12 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC | BI01010001010000000000000515BI0100001225 | 1 | no |
| 114 | 114 | 2.16 : Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. | BI01010001010000000000000515BI0100001226 | 18 | each |
| 115 | 115 | od77844/2020_2021 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof FP enclosure for independent mounting of MCB/ RCCB/ RCBO including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required | BI01010001010000000000000515BI0100001227 | 15 | no |
| 116 | 116 | 90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp | BI01010001010000000000000515BI0100001228 | 200 | metre |
| 117 | 117 | 90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp | BI01010001010000000000000515BI0100001229 | 120 | metre |
| 118 | 118 | 90.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp | BI01010001010000000000000515BI0100001230 | 20 | metre |
| 119 | 119 | 90.12.7.45 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 70 sq mm | BI01010001010000000000000515BI0100001231 | 30 | metre |
| 120 | 120 | 90.12.5.2 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm | BI01010001010000000000000515BI0100001232 | 200 | metre |
| 121 | 121 | 90.12.5.27 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 25 sq mm | BI01010001010000000000000515BI0100001233 | 120 | metre |
| 122 | 122 | 90.12.24.3 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm | BI01010001010000000000000515BI0100001234 | 50 | each |
| 123 | 123 | 90.12.24.4 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm | BI01010001010000000000000515BI0100001235 | 88 | each |
| 124 | 124 | 90.12.24.5 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.16 sq mm | BI01010001010000000000000515BI0100001236 | 56 | each |
| 125 | 125 | 90.12.24.6 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.25 sq mm | BI01010001010000000000000515BI0100001237 | 16 | each |
| 126 | 126 | 90.12.24.9 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.70 sq mm | BI01010001010000000000000515BI0100001238 | 12 | each |
| 127 | 127 | 90.16.1.2 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) | BI01010001010000000000000515BI0100001239 | 200 | metre |
| 128 | 128 | 90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) | BI01010001010000000000000515BI0100001240 | 440 | metre |
| 129 | 129 | 90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) | BI01010001010000000000000515BI0100001241 | 340 | metre |
| 130 | 130 | 9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) | BI01010001010000000000000515BI0100001242 | 18 | set |
| 131 | 131 | 9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) | BI01010001010000000000000515BI0100001243 | 8 | set |
| 132 | 132 | 9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) | BI01010001010000000000000515BI0100001244 | 4 | set |
| 133 | 133 | 9.1.1 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) | BI01010001010000000000000515BI0100001245 | 24 | set |
| 134 | 134 | 9.1.20 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm) | BI01010001010000000000000515BI0100001246 | 2 | set |
| 135 | 135 | od77814/2020_2021 : Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for 4sqmm-16 sq mm sizes of cables with 12 mm wide x 1 mm thick clip as required. | BI01010001010000000000000515BI0100001247 | 26 | no |
| 136 | 136 | od77815/2020_2021 : Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for 25 sq - 95sq mm sizes of cables with 20 mm wide x 1.20 mm thick clip as required. | BI01010001010000000000000515BI0100001248 | 14 | no |
| 137 | 137 | 5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | BI01010001010000000000000515BI0100001249 | 4 | set |
| 138 | 138 | od77816/2020_2021 : Supply and laying bare earthing conductors of size3.15 mm copper conductor (10 SWG) laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil). | BI01010001010000000000000515BI0100001250 | 30 | metre |
| 139 | 139 | od78317/2020_2021 : Supply and laying bare earthing conductors of size4.00 mm copper conductor (8 SWG) laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil). | BI01010001010000000000000515BI0100001251 | 20 | metre |
| 140 | 140 | od77817/2020_2021 : Supply and providing test joint for the earthing system using 2 Nos of 2x25x3mm of GI strip including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. | BI01010001010000000000000515BI0100001252 | 1.2 | metre |
| 141 | 141 | od77818/2020_2021 : Supply and providing 25 x 6 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required | BI01010001010000000000000515BI0100001253 | 30 | no |
| 142 | 142 | od77819/2020_2021 : Supply and providing 12 x 6 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required | BI01010001010000000000000515BI0100001254 | 30 | no |
| 143 | 143 | od77820/2020_2021 : Supply and providing 25 x 3 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required | BI01010001010000000000000515BI0100001255 | 30 | no |
| 144 | 144 | od77821/2020_2021 : Supply and providing 25 x 3 mm GI strip earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. | BI01010001010000000000000515BI0100001256 | 20 | no |
| 145 | 145 | 90.16.2.2 : Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.20 mm dia. G.I pipe ( medium class) | BI01010001010000000000000515BI0100001257 | 30 | metre |
| 146 | 146 | 90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) | BI01010001010000000000000515BI0100001258 | 20 | each |
| 147 | 147 | 90.16.5.4 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) | BI01010001010000000000000515BI0100001259 | 10 | each |
| 148 | 148 | 2.1.2 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N | BI01010001010000000000000515BI0100001260 | 3 | each |
| 149 | 149 | od78388/2020_2021 : Supply of 5 KVA on line UPS (HYKON make), single phase(72V), with 10 nos 120 AH ,12V,Tubular battery with 3 hours backup (HYKON make) | BI01010001010000000000000515BI0100001261 | 2 | no |
| 150 | 150 | od78360/2020_2021 : Fabricating and fixing enclosure for TP&N dis-connector fuse switch unit with handle assembly and HRC fuse as required. | BI01010001010000000000000515BI0100001262 | 1 | each |
| 151 | 151 | od77822/2020_2021 : Supply and fixing 2 -80A, DIN type fuse link of size 000 in the existing meter board and giving connections etc. | BI01010001010000000000000515BI0100001263 | 17 | no |
| 152 | 152 | od77823/2020_2021 : Supply and fixing 63 A, 415 V, 2 way neutral link mounted on DMC/ SMC base in the existing meter board and giving connections etc. | BI01010001010000000000000515BI0100001264 | 3 | no |
| 153 | 153 | od77824/2020_2021 : Supply and fixing 63 A, 415 V, DIN type fuse base in the existing meter board and giving connections etc. | BI01010001010000000000000515BI0100001265 | 17 | no |
| 154 | 154 | od77825/2020_2021 : \"Supply and Installation / Fixing / Provision of Outdoor type HENSEL make (600X300x214 mm Mi 2410) suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with complete tamper proof SEALING facility. \" | BI01010001010000000000000515BI0100001266 | 1 | no |
| 155 | 155 | od77826/2020_2021 : Supply, testing and installation of single phase 1/2 HP mono block open well pump (CRI / Texmo) | BI01010001010000000000000515BI0100001267 | 2 | Day |
| 156 | 156 | od77827/2020_2021 : Supply, testing and installation of 3 phase 3 HP submersible Bore well pump & motor with head range 35-121 mtrs having maximum flow rate of 7200 LPH at 72 Mtrs (make Texmo/Crompton/Kirloskar/CRI) | BI01010001010000000000000515BI0100001268 | 2 | each |
| 157 | 157 | od77828/2020_2021 : Supply and installation of 50 mm green hose, Well Flex or equivalent make on the delivery side of pump including giving connection to the existing pipe line. | BI01010001010000000000000515BI0100001269 | 240 | metre |
| 158 | 158 | od77829/2020_2021 : Supply of SS rope 6 mm | BI01010001010000000000000515BI0100001270 | 240 | metre |
| 159 | 159 | od77830/2020_2021 : Supply, and erection of C channel 75x50 mm | BI01010001010000000000000515BI0100001271 | 60 | kg |
| 160 | 160 | 90.12.10.2 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size | BI01010001010000000000000515BI0100001272 | 350 | metre |
| 161 | 161 | 90.14.28.2 : S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor | BI01010001010000000000000515BI0100001273 | 2 | each |
| 162 | 162 | 90.6.6.3 : Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm | BI01010001010000000000000515BI0100001274 | 300 | metre |
| 163 | 163 | od77832/2020_2021 : Supply and installation of K Class 4L Fire Extinguisher- Extinguishing Agent - Wet Chemical Propellant - Dry Nitrogen Operating Temp - +5 C to +55 Test Pressure - 35 bar for 30 sec Burst pressure - 55 bar at body, 80 bar at weld Filling Tolerance - ± 5% by volume Fire Test - As per UL 711 & EN 3 Material Cylinder body - SS 304L- Control valve - Brass-Dip Tube - PVC.Nozzle - brass with Ni-Cr plating-Hose - EPDM.Batch Test - As per IS 15683.Marking - As per IS 15683:2006 | BI01010001010000000000000515BI0100001275 | 1 | each |
| 164 | 164 | od77833/2020_2021 : Supply and installation of FIRE EXTINGUISHER - MAINTENANCE AND CORROSION FREE WITH MAGNET 2KG ABC POWDER (Fire Rating 13A/55B, C Flammable Gas and can be used on live current. - HSN Code - 8424 | BI01010001010000000000000515BI0100001276 | 6 | each |
| 165 | 165 | 2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. | BI01010001010000000000000515BI0100001277 | 1 | each |
| 166 | 166 | od77834/2020_2021 : Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required. | BI01010001010000000000000515BI0100001278 | 2 | no |
| 167 | 167 | od77835/2020_2021 : Supply & providing First Aid Chart duly framed and placed ina conspcious location for clear vision | BI01010001010000000000000515BI0100001279 | 2 | no |
| 168 | 168 | od77837/2020_2021 : Painting letters or figures of size 2.50 cm, 4 cm or 5 cm height with enamel paint as identification mark to SB, DB, panel board etc as required | BI01010001010000000000000515BI0100001280 | 300 | no |
AI Tender Summary
Tender Timeline
Nov 02, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedNov 13, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedNov 16, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender