Military Engineer Services-MES has published Repair / Renewal Of Defective Building Internal Electric Fittings And Fixtures , Wiring , Earthings At Zone-9 And Allied Works In Naval Dockyard , Visakhapatnam. Submission Date for this Tender is 03-12-2020. Electrification Work Tenders in Naval Dockyard Visakhapantam Andhra Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 20-Nov-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-11-2020 |
2 | 27-Nov-2020 | Corrigendum No 1 | Date | 03-12-2020 |
Name of Work: REPAIR / RENEWAL OF DEFECTIVE BUILDING INTERNAL ELECTRIC FITTINGS AND FIXTURES, WIRING, EARTHINGS AT ZONE-9 AND ALLIED WORKS IN NAVAL DOCKYARD, VISAKHAPATNAM | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Supply & Fix 5 Amp switch piano flush type single pole one way including dismantling taking down unsv one complete all as specified and as directed | 603 | Each | |
2 | 2 | Supply & Fix 15 Amp switch piano, flush type single pole one way including dismantling taking down unsv one complete all as specified and as directed | 10 | Each | |
3 | 3 | Supply & Fix bell push piano type one way 5Amp, 240 volt including dismantling taking down unsv one complete all as specified and as directed | 6 | Each | |
4 | 4 | Supply & Fix switch socket combination 5 pin 5 amps, 230 volt including dismantling taking down unsv one complete all as specified and as directed | 147 | Each | |
5 | 5 | Supply & Fix switch socket combination multipurpose 2-in-1 flush type 3 pin 15 amps and 3 pin 5 amps, 230 volt including dismentling taking down unsv one complete all as specified and as directed | 143 | Each | |
6 | 6 | Supply & Fix flush type electronic fan regulator with 5 step type,120 W, AC 240 Volts, two module, 50 Hz including dismantling taking down unsv one complete all as specified and as directed. | 100 | Each | |
7 | 7 | Supply & Fix ceiling rose surface Bakelite three terminal including dismantling taking down unsv one complete all as specified and as directed. | 142 | Each | |
8 | 8 | Supply & Fix bell electric AC 240 volt, 50 HZ. incl dismantling taking down unsv one complete all as specified and as directed. | 8 | Each | |
9 | 9 | Material & labour for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including FRLS PVC Conduit medium grade or PVC casing capping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including galvanised sunk metal terminal box fixed flush to wall with 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer for mounting of switch, regulators or bell push, ceiling rose/ holders etc., incl dismantling taking down old unserviceable point wiring and making good to disturbed surfaces complete all as specified and as directed. | 195 | Point | |
10 | 10 | All as per item No 9.00 above but for one 5 amps socket point independent complete all as specified and as directed. | 49 | Point | |
11 | 11 | All as per item No 9.00 above but for one 5 amps socket point in same board complete all as specified and as directed. | 24 | Point | |
12 | 12 | All as per item No 9.00 above but for one 15 amps socket point independent with 4.0 sqmm cable and 4.0 sqmm earth wire complete all as specified and as directed. | 76 | Point | |
13 | 13 | Supply & Fix modular switch 5 amp flush type,230v including dismantling taking down unsv one complete all as specified and as directed. \nMake- Anchor Roma/ Schneider/Legrand/Kona | ` | 5 | Each |
14 | 14 | Supply & Fix modular switch 15 amp flush type, 230v, one module including dismantling taking down unsv one complete all as specified and as directed. \nMake- Anchor Roma/ Schneider/Legrand/Kona | 5 | Each | |
15 | 15 | Supply & Fix modular bell push piano type one way 5Amp, 240 volt, one module including dismantling taking down unsv one complete all as specified and as directed.\nMake- Anchor Roma/ Schneider/Legrand/Kona | 5 | Each | |
16 | 16 | Supply & Fix modular socket multipurpose 15 amp and 5 amp flush type, 230v, two module, including dismantling taking down unsv one complete all as specified and as directed. \nMake- Anchor Roma/ Schneider/Legrand/Kona | 5 | Each | |
17 | 17 | Supply & Fix modular electronic fan regulator two module with 5 step type,120 W, AC 240 Volts, 50 Hz including dismantling taking down unsv one complete all as specified and as directed. \nMake- Anchor Roma/ Schneider/Legrand/Kona | 5 | Each | |
18 | 18 | Supply & Fix Modular white back plate with cover plate of 8 module complete with metal flush box fixed to wall, complete all as specified and as directed\nMake- Anchor Roma/ Schneider/Legrand/Kona | 4 | Each | |
19 | 19 | Supply & Fix Modular white back plate with cover plate of 12 module complete with metal flush box fixed to wall, complete all as specified and as directed\nMake- Anchor Roma/ Schneider/Legrand/Kona | 4 | Each | |
20 | 20 | Supply & Fix Modular white back plate with cover plate of 16 module complete with metal flush box fixed to wall, complete all as specified and as directed\nMake- Anchor Roma/ Schneider/Legrand/Kona | 4 | Each | |
21 | 21 | Supply & Fix Hylam Sheet 3mm thick on existing concealled MS/CI ractangular or Squar or round box with 04 nos cadmium coated screws and cup washer including cutting slots for mounting switch/socket/fan regulator/ batten holder etc including dismentling taking down unsv one complete all as specified and as directed | 3 | Sqm | |
22 | 22 | Supply & Fix PVC rectangular switch board of size 200mmx 150mm x50mm incl necessary cutting slots for mounting switch sockets etc including dismentling taking down unsv one complete all as specified and directed. \nMake- Presto Teak/Press Fit/Plaza. | 20 | Each | |
23 | 23 | Material & labour for surface wiring with 2 x 2.5 sqmm (Nominal area) single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable drawn through in and including FRLS PVC Conduit medium grade with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly incl dismantling taking down old unserviceable wiring and making good to disturbed surfaces complete all as specified and as directed. \nNote:- (a) Two run of cable with one run of earth wire and one run of casing capping/conduit shall be measured as one length.\n(b) working hight upto roof level of wksp buildings for item No- 5 only | 95 | RM | |
24 | 24 | All as per item No 23.00 above but cable of size 2 x 6.0 sqmm and earth wire 1x 6 sqmm | 335 | RM | |
25 | 25 | All as per item No 23.00 above but cable of size 4 x 10.0 sqmm and earth wire 1 x 10 sqmm | 96 | RM | |
26 | 26 | Supply & Fix MCB distribution board, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts, 8 way including dismantling taking down unsv one complete all as specified and directed. \nMake- Schneider, Cat Part No- A9HSND08 or equivalent of Legrand/L&T/ABB. | 15 | Each | |
27 | 27 | Supply & Fix MCB distribution board, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way including dismantling taking down unsv one complete all as specified and directed. \nMake- Schneider, Cat Part No- A9HTND04 or equivalent of Legrand/L&T/ABB. | 5 | Each | |
28 | 28 | Supply & Fix Vertical MCB distribution board suitable for MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way including dismantling taking down unsv one complete all as specified and as directed. \nMake- Schneider, Cat Part No- A9HVD04L or equivalent of Legrand/L&T/ABB. | 2 | Each | |
29 | 29 | Supply & Fix Vertical MCB distribution board suitable for MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 8 way including dismantling taking down unsv one complete all as specified and as directed. \nMake- Schneider, Cat Part No- A9HVD08L or equivalent of Legrand/L&T/ABB. | 1 | Each | |
30 | 30 | Supply & Fix MCCB, 25KA, 4 pole, with thermal magnetic trip unit, rated current 160 Amps complete with spider link including dismentling taking down unsv one complete all as specified and as directed (Suitable for MCCB incomer DB). \n[Make : Schneider, cat No- LV430321 Compact NSX] | 4 | Each | |
31 | 31 | Supply & Fix MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve including dismantling taking down unsv one complete all as specified and as directed. \n[Make- Schneider, Cat Part No- A9N1P06C - 32C or equivalent of Legrand/L&T/ABB]. | 275 | Each | |
32 | 32 | Supply & Fix MCB, Double Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve including dismantling taking down unsv one complete all as specified and as directed. \n[Make- Schneider, Cat Part No- A9N2P06C - 32C or equivalent of Legrand/L&T/ABB]. | 54 | Each | |
33 | 33 | Supply & Fix RCBO, 2 pole, rated current 16 amps, Sensitivity 300 mA, 240 Volts incl dismantling taking down unsv one complete all as specified and as directed.\n[Make- Schneider, Cat Part No- A9N19668 or equivalent of Legrand/L&T/ABB]. | 9 | Each | |
34 | 34 | Supply & Fix MCB, three Pole, 40 to 63 amps, 415 Volts including dismantling taking down unsv one complete all as specified and as directed. \n[Make- Schneider, Cat Part No- A9N3P40C - 63C or equivalent of Legrand/L&T/ABB]. | 24 | Each | |
35 | 35 | Supply & Fix MCB, Four Pole, 40 to 63 amps, 415 Volts including dismentling taking down unsv one complete all as specified and as directed. \n[Make- Schneider, Cat Part No- A9N4P40C - 63C or equivalent of Legrand/L&T/ABB]. | 23 | Each | |
36 | 36 | Supply & Fix Metal plug and socket board with MCB SP 20 amp, 16 KA including dismentling taking down unsv one complete all as specified and as directed. \n[Make- Schneider, Cat Part No- A9HMS220 or equivalent of Legrand/L&T/ABB]. | 29 | Each | |
37 | 37 | Supply & Fix Metal Plug 20amps, 2 pole, 230V complete all as specified and as directed, \n[Make- Schneider, Cat No-AP10 or equivalent of Legrand/L&T/ABB]. | 10 | Each | |
38 | 38 | Supply & Fix LED tube light fitting with LED tube, 2'long, 10 watt, CDL, 230 Volts , complete with all accssories internally pre wired including dismantling taking down unsv FTL/CFL fiitings complete all as specified and as directed. \n[Make-CG, Cat Part No-LDL-10-CDL (Trimline) or equivalemt in Havells/ Philips/ Bajaj] | 30 | Each | |
39 | 39 | Supply & Fix LED recessed round or square polycarbonate housing down lighter with superior light output and integral driver , 12 watt, warm white, complete with fixing spring clip 2 nos, fixed flush to gypsum/grid ceiling including dismantling taking down unsv one any type complete all as specified and as directed\n[Make- CG, cat-LCDEP-12-WW , Quartz +R or LSDEP-12-WW, \nQuartz +Sor equivelent of Philips/ Bajaj/ Havells] | 4 | Each | |
40 | 40 | Supply & Fix LED recessed round or square polycarbonate housing down lighter with superior light output and integral driver , 18 watt, warm white, complete with fixing spring clip 2 nos, fixed flush to gypsum/grid ceiling including dismantling taking down unsv one any type complete all as specified and as directed \n[Make- CG, cat-LCDEP-18-WW , Quartz +R or LSDEP-18-WW, \nQuartz +Sor equivelent of Philips/ Bajaj/ Havells] | 5 | Each | |
41 | 41 | Supply & Fix LED recessed square polycarbonate housing down lighter with superior light output and integral driver , 36 watt, warm white, complete with fixing spring clip 4 nos, fixed flush to gypsum/grid ceiling including dismantling taking down unsv one any type complete all as specified and as directed\n[Make- CG, cat-LCTRNE-36-FO-WW equivelent of Philips/ Bajaj/ Havells] | 5 | Each | |
42 | 42 | Supply & Fix LED recessed (4'x1') polycarbonate housing down lighter with superior light output and integral driver , 40 watt complete with fixing spring clip 4 nos, fixed flush to gypsum/grid ceiling including dismantling taking down unsv one any type complete all as specified and as directed\n[Make- CG, cat-LSTLRN-40-CDL (1x4) equivelent of Philips/ Bajaj/ Havells] | 40 | Each | |
43 | 43 | Supply & Fix LED flame proof batten suitable for twin T-8 tube of 20 watt, IP-65, 230V, CIMFR certified including necessary connection complete all as specified and as directed\n[Make-CG, Cat-EXTN2LT8-20 or equivelent of Sudhir/Shyam]\n[Note : LED retro Tube shall be issued under Sch B free for fixing] | 4 | Each | |
44 | 44 | Supply & Fix LED building security light 90 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener including dismantling taking down unsv fitting any type complete all as specified and as directed. \n[Make-CG, Cat Part No LSTP-90-CDL-M or equivalent in Philips/Havells/Havells] | 5 | Each | |
45 | 45 | Supply & Fix LED engagement light Red & Green including dismantling taking down unsv one complete all as specified and as directed. | 4 | Each | |
46 | 46 | Fixing only LED Tube light baten, 18/20 watt, 230 Volts, 4 feet long, complete with all accssories internally pre wired including dismantling taking down unsv FTL/CFL fiitings complete all as specified and as directed. \n[Note : LED fitting shall be issued under Sch B free for fixing] | 200 | Each | |
47 | 47 | Fixing only Square shaped recess mounted LED slim panel down lighter, 18/36 watt (1'X1' or 2`x2`), to POP/grid celing complete with all fixing accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable including dismantling taking down unsv FTL/CFL fiitings any type complete all as specified and as directed. \n(Note : LED fitting shall be issued under Sch B free for fixing] | 100 | Each | |
48 | 48 | Fixing only Retro LED tube 20 watt to new/existing single/twin box type industrial fitting with addition / alteration to existing wiring for retro LED connection complete all as specified and as directed.\n(Note : Retro LED tube shall be issued under Sch B free for fixing) | 666 | Each | |
49 | 49 | Fixing only LED high bay light 150/200 watt at roof truss level of wksp buildings and other places including dismantling taking down unsv one any type complete all as specified and as directed.\n(Note : LED down lighter 150/200 watt shall be issued under Sch B free for fixing) | 30 | Each | |
50 | 50 | Supply and fix to round block or double stiff pandent, industrial box type LED Batten with CRCA body, pre coated with white and prewired suitable for LED tube 1x18/20 watt 4' long including dismantling taking down unsv FTL/CFL fiitings complete all as specified and as directed. \n[Make-Bajaj, Cat Part No-BLRB-DB 118 or equivelent of Philips/CG/Havells] | 30 | Each | |
51 | 51 | Supply and fix to round block or double stiff pandent, industrial box type LED Batten with CRCA body, pre coated with white and prewired suitable for LED tube 2x18/20 watt 4' long including dismantling taking down unsv FTL/CFL fiitings complete all as specified and as directed. \n[Make-Bajaj, Cat Part No-BLRB-DB 218 or equivelent of Philips/CG/Havells] | 289 | Each | |
52 | 52 | Attending day to day complaint of No-light, circuit fault, non-functional of fan/light/switch/socket/regulator, frequent tripping of MCBs, realingnment/refixing of loose conduit/casing capping upto 5 mtr by providing suitable Electrician daily. Note: Work to be measured as unit specified. Contractor shall not claim for outsourcing. Work is to be carried out till rectification. Any material as in this schedule shall be measured as applicable. Required screws, shadles, nuts, bolts, insulation tapes shall be provided by the contractor. Complaint shall be collected from Online complaint cell and to be rectified within 2 hours else recovery shall be made double the quotaed rate. | 2000 | Each Job | |
53 | 53 | Supply & Fix Aluminium strip 25 x 3.15 mm laid in trench for earthing connection for various machines including dismantling taking down unsv strip complete all as specified and as directed. | 100 | RM | |
54 | 54 | Material & labour for Earthing complete with GI Pipe electrode, 40 mm bore, Medium grade, 2.5 mtr long buried directly and vertically in ground with top edge at ground level after making manual bore hole of size not less than 300 mm dia and 2.65 Mtr long near the specified bldg, connected with galvanised steel strip earthing lead of size 32mmx 6mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 80mm thick with handle for lifting made out of 8mm dia MS rod, wiremesh, charcoal and salt in alternate 150mm thick layers around CI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion after dismentling taking out unserviceable one.. | 73 | Each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy