| 1 | 1 | Taking down the Carefully unserviceable lights from Blast Pen /Hangers /road /bldgs mounted on poles and perimeter mounted on poles /walls of any capaciy /size and for HID lamp based lights any type and capacity and refixing after repair complete all as specified and directed by Engineer in Charge.\n(Note:- (i) After completion of contract, contractor shall hand over all the security/perimeter lights conventional type\" in perfect running/functioning condition to the department.\n(ii) Contractor shall provide his authorised Cell/mobile No. and local address to contact and communicate the message for any break down and contractor's rep will visit the office twice a day (0930 Hrs and 1430 Hrs) to collect the day to day complaints of any nature/type. \n(iii) Penalty for not rectifying the defect in time(within 72 hrs)will be charged to contractor and the amount of penalty @ Rs 1000/- per complaint will deducted from the due payment of contract.\n(iv) Complaints will be treated as rectified only after user's \"Satisfactory slip \"will be produced by contractor to concerned JE E/M.\n(v) Cost of attending day by day complaint is included in the rate quoted under this item, no extra payment for attending complaint shall be made.\n(vi) Old material obtained from spares replaced under this item shall be contractor's property and will be measured as per credit schedule.\n(vii) Cost of minor spares i.e, wirnig inside light fittng, connecting wire upto terminal box, nut bolts washers or accessories as required for fixing light on pole, connector blocks are deemed to be included in the item rate, items other than mentioned will be measured and paid seperately under respective item of work,\n(viii) Cost of T&P i.e, ladders, tools, brazing, welding, soldering required and transportation is deemed to be included in quoted rates\n(ix) Area cleaning if required within vicininty of lighing poles is to be done by contractor only and rate for area cleaning is deemed to be included in quoted rates .\n (X) Contractor will be take proper shutdown before repaire with communation of IPSS team / Security section for repaire of perimeter lights. \n | | 550 | Each Job |
|---|
| 2 | 1.01 | All as per item No 1.00 above but for LED lamp based lights any type and capacity complete all as specified and directed by Engineer-In-Charge. | | 2500 | Each Job |
|---|
| 3 | 1.02 | All as per item No 1.00 above but for CFL/Tublar lamp based lights any type and capacity complete all as specified and directed by Engineer-In-Charge. | | 50 | Each Job |
|---|
| 4 | 1.03 | All as per item No 1.00 above but forflame proof based lights any type and capacity complete all as specified and directed by Engineer-In-Charge. | | 75 | Each Job |
|---|
| 5 | 2 | Supply only following items 2.00 to 2.24 be fixed under Item No.1.00 to 1.03 above:-\nLED outdoor driver for 45 to 90 W LED light complete all as specified and directed by Engineer-In-Charge. | | 680 | Each |
|---|
| 6 | 2.01 | LED outdoor driver for 100 to 150 W LED flood/ street light complete all as specified and directed by Engineer-In-Charge. | | 150 | Each |
|---|
| 7 | 2.02 | Voltage surge protection device for LED lights of wattage upto 75 W of rating 5 KV complete all as specified and directed by Engineer-in-Charge. | | 300 | Each |
|---|
| 8 | 2.03 | Voltage surge protection device for LED lights of wattage 75W to 150 W of rating 5KV complete all as specified and directed by Engineer-in-charge. | | 220 | Each |
|---|
| 9 | 2.04 | Single core flexible multistranded copper conductor of size 1.5 sqmm complete all as specified and directed by Engr-In-Charge. | | 1350 | RM |
|---|
| 10 | 2.05 | Two core flexible multistranded aluminum conductor 16 sqmm complete all as specified and directed by Engineer-in-Charge. | | 300 | RM |
|---|
| 11 | 2.06 | MCB SP 6-32 Amps as per site requirement complete all as specified and directed by Engineer-In-Charge. | | 250 | Each |
|---|
| 12 | 2.07 | MCB SPN 6-32 Amps as per site requirement complete all as specified and directed by Engineer-In-Charge. | | 60 | Each |
|---|
| 13 | 2.08 | Electromagnetic choke suitable for HID Lamps of 70 watt, 240 volts complete all as specified and directed by Engineer-In-Charge. | | 5 | Each |
|---|
| 14 | 2.09 | Electromagnetic choke suitable for HID Lamps of 150 watt, 240 volts complete all as specified and directed by Engineer-In-Charge. | | 5 | Each |
|---|
| 15 | 2.1 | Electromagnetic choke suitable for HID Lamps of 250 watt, 240 volts complete all as specified and directed by Engineer-In-Charge. | | 2 | Each |
|---|
| 16 | 2.11 | Electromagnetic choke suitable for HID Lamps of 400 watt, 240 volts complete all as specified and directed by Engineer-In-Charge. | | 2 | Each |
|---|
| 17 | 2.12 | HPSV/MH Lamps 70 Watt with E-27 base complete all as specified and directed by Engr-In-Charge | | 5 | Each |
|---|
| 18 | 2.13 | HPSV/MH Lamps 150 Watt with E-40 base complete all as specified and directed by Engr-In-Charge\n | | 5 | Each |
|---|
| 19 | 2.14 | HPSV/MH Lamps 250 Watt with E-40 base complete all as specified and directed by Engr-In-Charge | | 2 | Each |
|---|
| 20 | 2.15 | HPSV/MH Lamps 400 Watt with E-40 base complete all as specified and directed by Engineer-In-Charge. | | 2 | Each |
|---|
| 21 | 2.16 | Tubular Lamp T5 14 Watt, 6500k complete all as specified and directed by Engr-In-Charge. | | 10 | Each |
|---|
| 22 | 2.17 | Tubular Lamp T5 24 Watt, 6500k complete all as specified and directed by Engr-In-Charge. | | 50 | Each |
|---|
| 23 | 2.18 | Electronic Choke suitable for 2x24Watt complete all as specified and directed by Engr-In-Charge. | | 10 | Each |
|---|
| 24 | 2.19 | Electronic Choke suitable for 2x14Watt complete all as specified and directed by Engr-In-Charge. | | 30 | Each |
|---|
| 25 | 2.2 | PVC 15 mm dia complete all fixing arrangement from Junction box to any type of fitting complete all as directed by Engr-In - Charge. | | 180 | RM |
|---|
| 26 | 2.21 | Steel conduit 15/20 mm dia complete all fixing arrangement from Junction box to any type of fitting complete all as directed by Engr-In - Charge. | | 120 | RM |
|---|
| 27 | 2.22 | Two core flexible multistranded aluminum conductor 10 sqmm complete all as specified and directed by Engr-In-Charge | | 540 | Each |
|---|
| 28 | 2.23 | MCB TPN 63 Amps, 415 volts, 10kA compllete all as specified and directed by Engr-In-Charge. | | 5 | Each |
|---|
| 29 | 2.24 | CFL retrofit 65 watt, 6500k with E-27/B-22 base as required at site and directed by Engr-In-Charge. | | 10 | Each |
|---|
| 30 | 3 | Supply and fix in replacement air break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 250 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engineer-in-Charge. | | 1 | Each |
|---|
| 31 | 4 | Supply and fix in replacement air break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 300 amps (normal life) with operating coil voltage 230 complete all as specified and directed by Engineer-in-Charge. | | 1 | Each |
|---|
| 32 | 5 | Supply and fix AC coil suitable for Power contactor 250 to 300 Amp exciting voltage 240/415 Volt complete all as specified and directed by Engineer-in-Charge. | | 2 | Each |
|---|
| 33 | 6 | Writing No of wall with letters/ figures of size not exc 30 mm with black paint on a yellow circle of dia 75 mm complete all as specified and directed by Engineer-in-Charge. | | 1200 | Job |
|---|
| 34 | 7 | Excavation in trenches in any type of soil exc 1.5 Mtr in width and not exc 1.5Mtr in depth and getting out for laying of cable complete all as specified and directed by Engineer-in-Charge. | | 810 | Cum |
|---|
| 35 | 8 | Returning filling in, including spreading leveling,watering and well ramming in layers not exc 1.5cm each layer complete all as specified and directed by Engineer-in-Charge. | | 519 | Cum |
|---|
| 36 | 9 | Removal of surplus soil to distance not exc 50mtr and depositing where directed at level not exc 1.5 mtr above the starting point complete all as required at site and directed by Engr-in-Charge. | | 291 | Cum |
|---|
| 37 | 10 | Sand cushioning to underground cable 8cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable complete all as specifed and directed by Engr-in-Charge. | | 241 | Cum |
|---|
| 38 | 11 | Reuse old Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as required at site and directed by Engr-in-Charge. | | 13000 | Each |
|---|
| 39 | 12 | Sub class “B” bricks laid dry flat cover the cable with width equal to the length of cable, abutting each other for protection of cable complete all as required at site and directed by Engr-in-Charge. | | 12.6 | Per 1000 Nos |
|---|
| 40 | 13 | Disconnecting electrically, taking out from trenches and removing from site/LT cable any size upto185sqmm 2/3.5 core.( Earth work will be measured seperatelly under respective items) complete all as specified and directed by Engr-in-Charge. | | 4865 | RM |
|---|
| 41 | 14 | Relaying only LT cable taking out aganist item No- 13 above or passing through pipe 1100 volts grade heavey duty cable with PVC insulated multistand alumn conductor of size 6 to 240 Sqmm 2/3.5 core , armoured with galvanized steel strip or wire complete all as specified and directed by Engr-in-Charge. | | 3000 | RM |
|---|
| 42 | 15 | Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 25 sq mm, 2 core complete all as specified and directed by Engr-in-Charge. | | 640 | RM |
|---|
| 43 | 16 | All as per item No. 15.00 above but of size 16 sq mm, 2 core complete all as specified and directed by Engr-in-Charge. | | 210 | RM |
|---|
| 44 | 17 | All as per item No. 15.00 above but of size 50 sq mm, 3.5 core complete all as specified and directed by Engr-in-Charge. | | 200 | RM |
|---|
| 45 | 18 | Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 185 sq mm, 3.5 core complete all as specified and directed by Engr-in-Charge. | | 845 | RM |
|---|
| 46 | 19 | Supply and fix LT cable jointing kit for 1100 V grade cable for end box heat shrink type joint indoor /outdoor complete with jointing material and accessories suitable for 2/4 core XLPE armoured Aluminium conductor cable of size 185 Sq mm 3.5 core complete all as specified and directed by Engr-in-Charge. | | 2 | Each |
|---|
| 47 | 20 | Supply and fix LT cable jointing kit for 1100 V grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Aluminium conductor cable of size 185-240 Sq mm 3.5 core complete all as specified and directed by Engr-in-Charge. | | 2 | Each |
|---|
| 48 | 21 | Supply and fix MCCB 3 pole 415 volts with rupturing cap 16 KA , 100 Amps thermal magnetic release of all as required at site and complete all as specified and directed by Engr-in-Charge. | | 6 | Each |
|---|
| 49 | 22 | Supply and fix MCCB 3 pole 415 volts with rupturing cap 16 KA 160 Amps thermal magnetic release complete all as specified and directed by Engr-in-Charge. | | 1 | Each |
|---|
| 50 | 23 | Supply and fix MCCB 3 pole 415 volts with rupturing cap 16 KA 320 Amps thermal magnetic release complete all as specified and directed by Engr-in-Charge. | | 1 | Each |
|---|
| 51 | 24 | Supply and fix in replacement on load change over switch of capacity 400 amps front operated four pole 415 volts 50 Hz for integrating electrically and connecting with existing panel all complete all as specified and directed by Engr-in-Charge. | | 1 | Each |
|---|
| 52 | 25 | Fixing only Ignitor suitable for HID Lamps of capacity 70 to 400 Watt complete all as specified and directed by Engr-In-Charge.( Ignitor shall be issued under Sch 'B' ) | | 50 | Each |
|---|
| 53 | 26 | Supply and fix multifunctional digital Astro Rex3 D-21 of Legrand or equivalent of make L&T/GE including connecting electrically using copper conductor cable of appropriate size all as required or complete all as specified and directed by Engr-in-Charge. | | 5 | Each |
|---|
| 54 | 27 | Supply and fix in replacement air break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 50 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engr-in-Charge. | | 5 | Each |
|---|
| 55 | 28 | Supply and fix in replacement air break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 70 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engr-in-Charge. | | 4 | Each |
|---|
| 56 | 29 | Supply and fix in replacement air break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 110 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engr-in-Charge. | | 3 | Each |
|---|
| 57 | 30 | Supply and fix AC coil suitable for Power contactor 50 to 110 Amp exciting voltage 240/415 Volt as per site requirment complete all as specified and directed by Engr-in-Charge. | | 5 | Each |
|---|
| 58 | 31 | Scraping of old paint from the street light steel tubular pole with out removing accessories and preparation of surfaces for repainting . Repainting the pole with one coat of alternative white and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint .Repainting the remaining pole and clamps GI bkt etc above 1.5 mtr height by applying one coat of alumn paint all as required at site or directed. | | 600 | Job |
|---|
| 59 | 32 | Painting of street light PCC pole without removing accessories with one coat of alternative yellow and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint .Colour washing the pole above 1.5 mtr height using snowcem of approved colour including painting the steel parts i.e clamps GI bkt etc by applying one coat of alumn paint all as required at site or directed. | | 200 | Job |
|---|
| 60 | 33 | Supply and fix Pressure die-cast aluminium IP 65 cool white flood Light luminaire with rating not less than 150 Watt LED as light source including with Bracket , double clamps complete with nut bolts with pole and connection wire complete all as specified and directed by Engineer-in-Charge. | | 17 | Each |
|---|
| 61 | 34 | Supply and fix pressure die-cast aluminium IP 65 cool white flood Light luminaire with LED as Light source with rating not less than 120 Watt LED as light source including with Bracket , double clamps complete with nut bolts with pole and connection wire complete all as specified and directed by Engineer-in-Charge. | | 27 | Each |
|---|
| 62 | 35 | Supply and fix pressure die-cast aluminium IP 65 cool white road way luminaire with LED as Light source with rating not less than 72 Watt including with suitable GI Pipe Bracket , double clamps complete with nut bolts with pole and 2.5 sqmm 3 core copper wire multistrand for connection from DB to Light complete all as specified and directed by Engineer-in-Charge. | | 55 | Each |
|---|
| 63 | 36 | Supply and fix in repair street light control switch of size 40 x 40 x 30 cm made out of MS sheet 3.15 mm thick factory fabricated, duly powder coated with front door operable heaving pressure lock suitable for and including the followings :- (i) Air break contactor AC 415 volts, 50 HZ 3 phase 32 A with operating coil voltage 220 volts - 01 No \n(ii) Toggle switch 5 amps 230 volts for auto/manual operation – 01 No \n(iii) MCBs SP, 240 volts 63 Amps, 10 KA - 03 Nos complete all as specified and directed by Engineer-in-Charge. | | 1 | Each |
|---|
| 64 | 37 | Fixing only in truly vertical position steel tubular pole 9/11 mtr long any size issued under Schedule 'B' including painting with alternative yellow & black strips of 30 cm width upto 1.5 mtr above ground level and with one coat of alumn paint above 1.5 mtr complete all as specified and directed by Engineer-in-Charge. ( steel pole shall be issued under Sch 'B'.) | | 3 | Each |
|---|
| 65 | 38 | PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in benching including whethering slightly chamfered angles and finished exposed surfaces even and smooth including necessary form work for concrete eathing pit complete all as specified and directed by Engineer-in-Charge. | | 0.5 | Cum |
|---|
| 66 | 39 | Supply and fixing LT cable jointing kit for 1100 V grade cable for end box heat shrink type joint indoor /outdoor complete with jointing material and accessories suitable for 2/4 core XLPE armoured Aluminium conductor cable of size 10-25 Sq mm 2/4 core complete all as specified and directed by Engineer-in-Charge. | | 4 | Each |
|---|
| 67 | 40 | Supply and fixing LT cable jointing kit for 1100 V grade cable for end joint indoor/outdoor heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Aluminium conductor cable of size 25-50 Sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge. | | 5 | Each |
|---|
| 68 | 41 | Supply and fixing LT cable jointing kit for 1100 V grade cable for straight heat shrink type joint complete with jointing material and accessories suitable for 2/4 core XLPE armoured Aluminium conductor cable of size 10-25 Sq mm 2/4 core complete all as specified and directed by Engineer-in-Charge. | | 2 | Each |
|---|
| 69 | 42 | Supply and fixing LT cable jointing kit for 1100 V grade cable for end joint indoor/outdoor heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Aluminium conductor cable of size 25-50 Sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge. | | 5 | Each |
|---|
| 70 | 43 | Supply and fixing GI tubing light grade 40 mm dia with all fittings laid in trenches or fixed on wall along pole complete for proetection of electric cable complete all as specified by Engineer - in- charge. | | 20 | RM |
|---|
| 71 | 44 | Supply and fixing MCCB 3 pole 415 volts with rupturing cap 16 KA 63 Amps thermal magnetic release complete all as specified by Engineer - in- charge. | | 3 | Each |
|---|
| 72 | 45 | Supplying, installing and commissioning of LT feeder box, outdoor type of size 0.90m x 0.60m x 0.50m, made out of MS sheet 3.15mm thick, legs made out of angle iron 40mmX40mmX6mm, 1.50m long (1.00m above ground level and 0.50m embedded in PCC (1:2:4), with openable shutter on both side (front and rear) having locking arrangement with 300 Amp rated aluminium bus bar suitable for 3 phase, 4 wire supply, drilled holes for cable connection, mounted on epoxy based post insulators and MCB SPN 63 Amps, 230 volts -03 No's, complete all as specified by Engineer - in- charge. | | 1 | Each |
|---|
| 73 | 46 | Supplying, installing and commissioning of LT feeder box, outdoor type of size 0.90m x 0.60m x 0.50 m, made out of MS sheet 3.15mm thick, legs made out of angle iron 40mmX40mmX6mm, 1.50m long (1.00m above ground level and 0.50m embedded in PCC (1:2:4), with openable shutter on both side (front and rear) having locking arrangement with 300 Amp rated aluminium bus bar suitable for 3 phase, 4 wire supply, drilled holes for cable connection, mounted on epoxy based post insulators and MCCB 4 pole, 160 Amp, 415 volt, microprocessor release with rupturing capacity 36 KA, complete all as specified by Engineer - in- charge. | | 1 | Each |
|---|
| 74 | 47 | Supply, Installing testing & commissioning of street Light Pole Box two no Aluminium Bus Bar of capacity 63 amp including 6 Amp SP MCB.The Box should have auto Door lock facility with magnetic lock having size 260X120X230 mm and fixed to poles/ Wall using and nuts & bolts of required size all as required at site or directed by Engr-in-charges. | | 33 | Each |
|---|