Public Health Engineering Department-PHED has published Supply , Installation And Management Of Sensor And Iot Control Unit In Village Piped Water Supply Scheme. Submission Date for this Tender is 13-11-2020. Pump Supply Tenders in ARUNACHAL PRADESH Arunachal Pradesh. Bidders can get complete Tender details and download the document.
Name of Work:supply, installation and management of sensor and IOT control unit in village piped water supply scheme | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 2 | IOT | |||
2 | 3 | Basic (Level 1):- Smart Flow meter at outlet of CWR | 1 | Nos | |
3 | 4 | Intermediate (Level 2):- Smart Flow meter at outlet of CWR, Pump automation set up for auto cutoff/dry run protection for back wash pump, 1 pressure sensor at tail end or farthest distance, Variable frequency drive (VFD), LED touch screen with HMI operating systems where parameters can be set even manually, fitted with anti-theft alarm system. | 1 | Nos | |
4 | 5 | Advanced (Level 3):- | |||
5 | 6 | i. All parameters covered under level 2 | 1 | Nos | |
6 | 7 | water quality testing parameters | |||
7 | 8 | Residual Chlorine | 1 | Nos | |
8 | 9 | pH | 1 | Nos | |
9 | 10 | Turbidity | 1 | Nos | |
10 | 11 | TDS | 1 | Nos | |
11 | 12 | Consumer level metering | 1 | Nos | |
12 | 13 | Where there is no reliable electricity; | |||
13 | 14 | Cost of solar power system for Level 1 | 1 | Nos | |
14 | 15 | Cost of solar power system for Level 2 | 1 | Nos | |
15 | 16 | Cost of solar power system for Level 3 | 1 | Nos | |
16 | 17 | Basic (Level 1):- Smart Flow meter at outlet of OHT/Pump | 1 | Nos | |
17 | 18 | Intermediate (Level 2):- Smart Flow meter at outlet of OHT/Pump, Pump automation set up for auto cutoff/dry run protection for pump, 1 pressure sensor at tail end or farthest distance, Variable frequency drive (VFD), LED touch screen with HMI operating systems where parameters can be set even manually, fitted with anti-theft alarm system. | 1 | Nos | |
18 | 19 | Advanced (Level 3):- | 1 | Nos | |
19 | 20 | i. All parameters covered under level 2 | 1 | Nos | |
20 | 21 | water quality testing parameters | |||
21 | 22 | Residual Chlorine | 1 | Nos | |
22 | 23 | pH | 1 | Nos | |
23 | 24 | Turbidity | 1 | Nos | |
24 | 25 | TDS | 1 | Nos | |
25 | 26 | Consumer level metering | 1 | Nos | |
26 | 27 | Where there is no reliable electricity; | |||
27 | 28 | Cost of solar power system for Level 1 | 1 | Nos | |
28 | 29 | Cost of solar power system for Level 2 | 1 | Nos | |
29 | 30 | Cost of solar power system for Level 3 | BI01010001010000000000000515BI0100001128 | 1 | Nos |