Military Engineer Services-MES has published Replacement Of Conventional Light Fittings To Led Lights Of Internal Electrification And Special Repair To Oh To Underground Cable At 22 P And S U , Mccf , Aksta And Vsn Nagpur. Submission Date for this Tender is 18-11-2020. Electrification Work Tenders in GE AF NAGPUR Maharashtra. Bidders can get complete Tender details and download the document.
Name of Work: REPLACEMENT OF CONVENTIONAL LIGHT FITTINGS TO LED LIGHTS OF INTERNAL ELECTRIFICATION AND SPECIAL REPAIR TO OH TO UNDERGROUND CABLE AT 22 P&S (U), MCCF, AKSTA AND VSN NAGPUR | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down the existing any type fittings from ceilings and S & F 18 Watt LED round recessed flat panel light pearl model with locking arrangement in ceiling with a nominal system lumen output of 1800 lumens and a minimum system efficacy of 100 lumen/watt. The luminaire shall have rated system lifetime of 50,000 burning hours at L70 all as specified and directed. Make : CG Cat Part No. LSCRM-18W-CDL/NW, Wipro Cat Part No. LD95-221, Bajaj Cat Part No. BGSLO SLEEK 18 WH RD. | 20 | Each | |
2 | 2 | Taking down old unserviceable any type fittings, Supply & Fixing Decorative LED light 18 watt round surface mounting flat panel type complete with all accessories & connector etc internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, all as specified and directed. Make : CG Cat Part No. LCDSPLN-R-18W-CDL, Wipro Cat Part No. LD80-171, Bajaj Cat Part No. BGSLO SLEEK SURFACE 18W WH RD. | 110 | Each | |
3 | 3 | Taking down the existing any type fittings on ceilings and S & F 36 Watt LED Luminaire suitable for 600x600mm modular ceiling grid including frame of suitable size of above LED light with high efficiency PMMA diffuser gives soft glare free light with available lumen output from 3600 total lumen.The 36 W system shall be operating at 220-240v AC supply having internal driver .IP20,surge protection 2KV ,ambient temperature -20 to 45 degree C, frequency 50 to 60 Hz ,The system efficacy must be between80-100 lumen /watt ,with 70% lumen maintenance upto 50000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread , CRI minimum 80. PF should be greater than 0.95 , THD < 10% . Indivisual LED's should not be visible for glare free output ,colour temperature 6500k all as specified and directed. Make : CG Cat Part No. LCTLRN-36-FO-CDL, Wipro Cat Part No. CRCO10R038HP57GL, Bajaj Cat Part No. BZRSQL 36W GZi WH. | 18 | Each | |
4 | 4 | Taking down the existing any type fittings FTL industrial box type and S & F LED batten industrial box type luminare suitable for single T8 LED tube all as specified and directed. Make : Make : CG Cat Part No. IGP131LT8-16, Wipro, Bajaj. | 40 | Each | |
5 | 5 | Supply and fix master led tube 4ft 20 W LED Tube polycarbonate type . nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70.The luminaire should have a color temperature of 6500K and CRI>83. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. The total power consumption should not exceed 20 W (including driver) including taking down old unserviceable fittings any type including 2 nos PVC square block complete all as specified and as directed. Make : CG Cat Part No. LT8-20-865-2, Wipro Cat Part No. LL13-181-65SE, Bajaj Cat Part No. BLRB 18W CW LED | 1090 | Each | |
6 | 6 | Taking down the existing any type fittings FTL type and S & F decorative box type fitting with blue coloured end caps pre wired for LED tube energy of 20 Watt all as specified and directed. Make : CG Cat Part No. DMLN1LT8-16, Wipro Cat Part No. WIO921208, Bajaj Cat Part No. BLRB-DB 118. | 1050 | Each | |
7 | 7 | S & F Surface mounting 9 Watt LED Luminaries complete 2 core flexible cord of compatible size and testing complete including LED lamp, including taking down old unserviceable fittings any type including 2 nos PVC round block complete all as specified and as directed . Make : CG Cat Part No. LCTL-9-CDL, Wipro Cat Part No. LL20-111, Bajaj Cat Part No. BCLSB 10 WH. | 800 | Each | |
8 | 8 | Taking down the existing any type building security light and S & F 25 Watt LED Bldg security light alongwith fitting with a nominal system lumen output of 2500 lumens and a minimum system efficacy of 100 lumen/watt. The luminaire shall have rated system lifetime of 50,000 burning hours at L70. The luminaire should have cool white colour temperature (CCT>5000K) and a CRI>70. The luminaire shall meet IP66 rating with THD<20% & Pf>0.9. The luminaire housing should be made of pressure die cast aluminium fitted on GI pipe light grade (25 mm) bracket of 1500 mm length in required shape for roadway lighting luminaire with suitable clamp for fixing bracket and fittings complete with one coat of Aluminium paint over coat of redoxide all as specified and directed. The total power consumption should not exceed 25 W (including driver)Including taking down old unserviceable fittings all as specified and as directed . Make : CG Cat Part No. LSTS-25-CDL, Wipro Cat Part No. LR06-311, Bajaj Cat Part No. BRLEP 25W LED WH. | 20 | Each | |
9 | 9 | Taking down old unserviceable any type spot light fittings and S&F 6 watt round recessed LED spot light ideal for wardrobes, displays with locking arrangement in ceiling with a nominal system lumen output of 600 lumens and a minimum system efficacy of 100 lumen/watt. The luminaire shall have rated system lifetime of 50,000 burning hours at L70 all as specified and directed. Make : CG Cat Part No. LCSRR-6-CDL/TL/WW, Wipro, Bajaj. | 8 | Each | |
10 | 10 | Taking down old unserviceable any type flame proof light and S&F 2 x 20 watt flame proof LED tube light fixture complete with all accessories & connector etc internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed. Make : CG Cat Part No. EXTN2LT8-20, Wipro, Bajaj. | 3 | Each | |
11 | 11 | Dismantling ACSR squirel conductor complete all as specified and directed | 2 | Qtl | |
12 | 12 | Dismantling cross-arms of MS channel or angle section complete | 1 | Qtl | |
13 | 13 | Dismantling insulators any type and any size | 30 | EACH | |
14 | 14 | Supply and laying LT UG PVC insulated 1100 volt grade heavy duty cable multi stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel strip wire or tape and connecting up to the electrical system with suitable size of aluminium lugs of size 35 sq mm 3.5 core complete all as specified and directed. | 120 | RM | |
15 | 15 | Supply and laying LT UG PVC insulated 1100 volt grade heavy duty cable multi stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel strip wire or tape and connecting up to the electrical system with suitable size of aluminium lugs of size 10 sq mm 4 core complete all as specified and directed. | 430 | RM | |
16 | 16 | Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed by Engineer-in-Charge | 113 | CUM | |
17 | 17 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipes have been laid and tested complete all as specified and directed by Engineer-in-Charge | 106 | CUM | |
18 | 18 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed by Engineer-in-Charge | 7 | CUM | |
19 | 19 | M & L for Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 of size 40 mm dia laid in trenches for passing of LT cable complete all as specified and directed. | 450 | RM | |
20 | 20 | Supplying and fixing un-reinforced precast concrete cable cover class LV type 1 with peak, size 250mm x 150mm x 40mm all as specified and directed by Engr-in-Charge | 1600 | EACH | |
21 | 21 | M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed . | 18 | RM | |
22 | 22 | Dismantling and Taking out old unserviceable cable junction boxes and Supply and fixing thermoplastic cable junction boxes IP 66 "halogen free and weather proof" for outdoor Installation with metric knockout for cable entry of size139 x119x70mm fixing on pole with MS clamps, nut bolts, washers and glands suitable for 6 Sq mm 02 core cable including taking down old unserviceable cable junction boxes all as specified and directed. Make : HENSEL Cat No K-9065 ( ISI marked/Sintex marked/ Rittel ISI marked ) | 14 | Each | |
23 | 23 | Dismantling and Taking out old unserviceable main switch and M & L for switching ON and OFF the street lights based on astro time controlling switch for automatic controller of street light on 2.0 mm thick sheet metal enclosure consist of 230 Volt astro Time Switch, MCB TPN 32 Amp. 440 volt contactor 25 Amp, selector switch for auto and manual and internally pre wired, terminal blocks mounting brackets, cable glands and openable door with lock and key and manual setting features complete all as specefied and directed. Make: L&T, Legrand, Indo asian | 1 | Each | |
24 | 24 | Supply and fix 3 core 1.5 sqmm PVC insulated PVC sheathed weather proof multistranded Copper conductor cable 1100 volts grade drawn through in GI conduit, pole etc with MS clamps from junction box to street light fitting all as specified and directed. \nNote- GI tube shall be measured and paid separately | 100 | RM | |
25 | 25 | Supply and fix 15 mm dia GI tubes light grade with all fitting from looping box to street light fittings with clamps, nuts & bolts complete all as specified and as directed | 50 | RM | |
26 | 26 | Supply and fix 40 mm dia GI tubes medium grade with all fitting from looping box to street light fittings with clamps, nuts & bolts complete all as specified and as directed | 18 | RM | |
27 | 27 | M&L for preparing surfaces of LT electric poles of any type size including street light brackets, bracket clamps, cable protection pipe, terminal box, stay etc of any sizes and shape & dusting, cleaning the surface complete and applying one coat of aluminium paint completely including painting strips on poles with one coats of sky blue and white synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge. | 14 | Each | |
28 | 28 | M&L for stickering of pole No. with letters of size 25 mm height on pole/ plate complete all as specified and as directed by engineer in charge. | 14 | Each | |
29 | 29 | Dismantling and Taking out old unserviceable street Light fittings and Supply, Installation, Testing and Commissioning of Integral LED street light luminarie 45 Watt die cast aluminium housing designed to act as heat sink for efficient dissipation of heat. Elecrochemically brightened and anodized aluminium reflector. Heat resistant toughened glass is provided with die cast aluminium frame. (IK 08) luminarie provided with a mounting bracket for aiming adjustment. Driver is provided with input voltage surge (10kV), open and short circuit protection. system wattage 45 W and power factor 0.90. \nMake CG LSTS-45-CDL-M, Philips, Bajaj | 14 | EACH | |
30 | 30 | Dismantling and Taking out old unserviceable flood Light fittings and Supply, Installation, Testing and Commissioning of Integral LED flood light luminarie 50 Watt die cast aluminium housing designed to act as heat sink for efficient dissipation of heat. Elecrochemically brightened and anodized aluminium reflector. Heat resistant toughened glass is provided with die cast aluminium frame. (IK 08) luminarie provided with a mounting bracket for aiming adjustment. Driver is provided with input voltage surge (10kV), open and short circuit protection. system wattage 60 W and power factor 0.90. \nMake CG LFL-50-CDL/60-M, Philips, Bajaj | 4 | EACH | |
31 | 31 | Dismantling and Taking out old unserviceable flood Light fittings and Supply, Installation, Testing and Commissioning of Integral LED flood light luminarie 120 Watt die cast aluminium housing designed to act as heat sink for efficient dissipation of heat. Elecrochemically brightened and anodized aluminium reflector. Heat resistant toughened glass is provided with die cast aluminium frame. (IK 08) luminarie provided with a mounting bracket for aiming adjustment. Driver is provided with input voltage surge (10kV), open and short circuit protection. system wattage 135 W and power factor 0.90. Make CG Cat No LFLN-120-CDL/60-M, Philips, Bajaj | 3 | EACH | |
32 | 32 | Dismantling and Taking out old unserviceable Post Top Light fittings and Supply and fixing in replacement for Post Top latern fitting 20 Watt LED Decorative indirect posttop for garden,Gate,landscape lighting. IP 65 protection.Resistant to impact and corrosion. Glare-free and better uniformilty and complete all as directed by Engineer-in-Charge Make : Bajaj Cat No BGCT W4 LED WW, Philips, CG | 2 | Each | |
33 | 33 | Supply and fix bracket for street light fittings made out of 40 mm bore GI pipe of light grade bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 32 x 6 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with one coat of aluminium paint over a coat of red oxide primer and fittings bracket to street light fitting including taking down old unserviceable bracket of any shape and size all as specified and as directed. | 14 | Each | |
34 | 34 | M & L for New earthing complete with Copper plate earth electrode 600X600X3.0 mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to 20x3mm copper strip at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete. \n | 2 | Each Job | |
35 | 35 | M & L for New earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 25X4mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete. \n | 2 | Each Job | |
36 | 36 | Repair/Maintenance of LT Panel board any type and size by taking shut down,cleaning and removing of carbon particles, rubbing of heated portion of bus bar and cleaning complete and fine setting, tightening of all joints in bus bar, earthing etc and welding of broken doors including replacement of u/s nuts/bolts/washers and replacement of corroded glands, lugs/ thimbles and tightening them properly and testing all as directed.\nNote:- Spare parts for LT will be measured and paid separately. \n | 2 | Each Job | |
37 | 37 | (a) Digital ammeter flush type 96 sqmm with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring. Make L&T, Cat No WDS301OCA00 | 1 | Each | |
38 | 38 | (b ) Digital voltmeter flush type 96 sqmm with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring. Make L&T, Cat No WDV303FC000 | 1 | Each | |
39 | 39 | (c) Indicator lamp assembly LED type (RYB) in existing LT panel with suitable wiring and volts. | 6 | Each | |
40 | 40 | M & L for sub main wiring (concealed) complete with two single core 4 Sqmm FR PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 4 Sqmm FR PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Make of cable : Polycab, Finolex,Havells Note: 3 run of 4 sqmm&one run of PVC conduit shall be measured as single unit | 20 | RM |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy