Jaljeevan Mission 2020 21Thiruvananthapuram District Replacement Of Damaged Ac And Pvc Pipes Extension Of Pipe Line And Providing House Connection In Elakamon Grama Panchayath
Tender Value
2.38 Crore
Estimated cost
Bid Submission
02 Nov 2020
0 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
7500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Elakamon → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Jaljeevan Mission 2020 21Thiruvananthapuram District Replacement Of Damaged Ac And Pvc Pipes Extension Of Pipe Line And Providing House Connection In Elakamon Grama Panchayath
BOQ
| Name of Work: JALJEEVAN MISSION 2020-21- Replacement of damaged AC& PVC pipes,Extension of pipe line and providing house connections in Elakamon Grama panchayath -part 2 | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Appendix- A- Water connection to be given after line extension and Construction of valve chember | |||
| 2 | 1.01 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil (Ref. Item No. 2.10.1 of DSR) | BI01010001010000000000000515BI0100001115 | 3740 | cum |
| 3 | 1.02 | Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals. (Data Prepared based on PWD SDB - Item No.1009) | BI01010001010000000000000515BI0100001116 | 2000 | metre |
| 4 | 1.03 | Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 90 mm nominal outer dia pipes.\" | BI01010001010000000000000515BI0100001117 | 7500 | metre |
| 5 | 1.04 | Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work80 mm dia nominal bore | BI01010001010000000000000515BI0100001118 | 400 | metre |
| 6 | 1.05 | Supply of PVC Pipe, 6kg/cm2, 90mm Dia. | BI01010001010000000000000515BI0100001119 | 7500 | metre |
| 7 | 1.06 | Taking inter connection from 110/90/75/63 to 90mm line PVC distribution main a branch line using suitable size Tee (Tee connection only) and reducers including cost of materials labour charges etc complete | BI01010001010000000000000515BI0100001120 | 30 | No |
| 8 | 1.07 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix) | BI01010001010000000000000515BI0100001121 | 10 | cum |
| 9 | 1.08 | Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm. | BI01010001010000000000000515BI0100001122 | 9 | No |
| 10 | 1.09 | \"Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :80 mm diameter. Class I\"Observed Data derived from item no.18.31.of DAR | BI01010001010000000000000515BI0100001123 | 9 | Nos |
| 11 | 1.1 | Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. | BI01010001010000000000000515BI0100001124 | 1404 | Nos |
| 12 | 1.11 | Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers. | BI01010001010000000000000515BI0100001125 | 25272 | metre |
| 13 | 1.12 | Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers. | BI01010001010000000000000515BI0100001126 | 1404 | Nos |
| 14 | 1.13 | Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work15 mm dia nominal bore | BI01010001010000000000000515BI0100001127 | 600 | metre |
| 15 | 1.14 | Charges for Geo tagging | BI01010001010000000000000515BI0100001128 | 1404 | No |
| 16 | 1.15 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | BI01010001010000000000000515BI0100001129 | 15.21 | cum |
| 17 | 1.16 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | BI01010001010000000000000515BI0100001130 | 1.522 | cum |
| 18 | 1.17 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001131 | 7.333 | cum |
| 19 | 1.18 | Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | BI01010001010000000000000515BI0100001132 | 34.56 | sqm |
| 20 | 1.19 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001133 | 586.4 | kilogram |
| 21 | 1.2 | 12 mm cement plaster finished with a floating coat of neat cement of mix: | BI01010001010000000000000515BI0100001134 | 38.88 | sqm |
| 22 | 1.21 | Supplying and fixing CI MH Cover with frame (Heavy) with weight not less than 208 Kg | BI01010001010000000000000515BI0100001135 | 9 | No |
| 23 | 2 | Appendix- B-water connection given after renovation of the scheme(replacing damaged pipe) | BI01010001010000000000000515BI0100001136 | ||
| 24 | 2.01 | Dismantling of flexible pavement ( bituminous courses ) by mechanical means and disposal of dismantled material up to a lead of 1 kilo metre, as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001137 | 60 | cum |
| 25 | 2.02 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil (Ref. Item No. 2.10.1 of DSR) | BI01010001010000000000000515BI0100001138 | 673.04 | cum |
| 26 | 2.03 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :\"Ordinary Rock. (Ref. Item No. 2.13.1 of DSR) | BI01010001010000000000000515BI0100001139 | 120.96 | cum |
| 27 | 2.04 | Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals. (Data Prepared based on PWD SDB - Item No.1009) | BI01010001010000000000000515BI0100001140 | 1000 | metre |
| 28 | 2.05 | Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials :200 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.17 in DAR | BI01010001010000000000000515BI0100001141 | 1000 | metre |
| 29 | 2.06 | Labour for cutting C.I. pipe with steel saw.200 mm diameter C.I. pipe | BI01010001010000000000000515BI0100001142 | 12 | Each Cut |
| 30 | 2.07 | Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:200 mm dia pipes | BI01010001010000000000000515BI0100001143 | 132 | joint |
| 31 | 2.08 | Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 200 mm diameter. Class II\" Data derived from item no.18.31.4.2of DAR | BI01010001010000000000000515BI0100001144 | 1 | Nos |
| 32 | 2.09 | Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :100 mm diameter. Class II\" Data derived from item no.18.31.1.2of DAR | BI01010001010000000000000515BI0100001145 | 2 | Nos |
| 33 | 2.1 | Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately):50 mm Double acting Air Valve Data derived from item no.18.59.1 of DAR | BI01010001010000000000000515BI0100001146 | 2 | Nos |
| 34 | 3 | Construction of valve chember -Anchor block,culvert crossing and miscellaneous works | BI01010001010000000000000515BI0100001147 | ||
| 35 | 3.01 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil | BI01010001010000000000000515BI0100001148 | 21.348 | cum |
| 36 | 3.02 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) | BI01010001010000000000000515BI0100001149 | 1.807 | cum |
| 37 | 3.03 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001150 | 11.099 | cum |
| 38 | 3.04 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | BI01010001010000000000000515BI0100001151 | 46.851 | sqm |
| 39 | 3.05 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001152 | 647.2 | kilogram |
| 40 | 3.06 | 12 mm cement plaster finished with a floating coat of neat cement of mix: | BI01010001010000000000000515BI0100001153 | 25 | sqm |
| 41 | 3.07 | Supplying and fixing CI MH Cover with frame (Heavy) with weight not less than 208 Kg | BI01010001010000000000000515BI0100001154 | 5 | No |
| 42 | 3.08 | Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. | BI01010001010000000000000515BI0100001155 | 2 | cum |
| 43 | 4 | cost of pipe and specials | BI01010001010000000000000515BI0100001156 | ||
| 44 | 4.01 | Supply of DI K9 Pipe Conforming to IS 8329/2000, 200mm Dia. | BI01010001010000000000000515BI0100001157 | 1000 | metre |
| 45 | 4.02 | Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 50mm. | BI01010001010000000000000515BI0100001158 | 2 | No |
| 46 | 4.03 | Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.0, Size 100mm. | BI01010001010000000000000515BI0100001159 | 2 | No |
| 47 | 4.04 | Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.0, Size 200mm. | BI01010001010000000000000515BI0100001160 | 1 | No |
| 48 | 4.05 | Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 : | BI01010001010000000000000515BI0100001161 | 9.66 | quintal |
| 49 | 5 | Providing water connections | BI01010001010000000000000515BI0100001162 | ||
| 50 | 5.01 | Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. | BI01010001010000000000000515BI0100001163 | 750 | Nos |
| 51 | 5.02 | Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers. | BI01010001010000000000000515BI0100001164 | 13500 | metre |
| 52 | 5.03 | Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers. | BI01010001010000000000000515BI0100001165 | 750 | Nos |
| 53 | 5.04 | Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work15 mm dia nominal bore | BI01010001010000000000000515BI0100001166 | 200 | metre |
| 54 | 5.05 | Charges for Geo tagging | BI01010001010000000000000515BI0100001167 | 750 | No |
| 55 | 5.06 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001168 | 91.8 | cum |
AI Tender Summary
Tender Timeline
Oct 28, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedNov 02, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedNov 04, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender