Water Resources and Irrigation Local Bodies Closing in 0 days TDR #25850224

Jaljeevan Mission 2020 21Thiruvananthapuram District Replacement Of Damaged Ac And Pvc Pipes Extension Of Pipe Line And Providing House Connection In Elakamon Grama Panchayath

Issued by Local Bodies · Elakamon, Kerala
Tender Value
2.38 Crore
Estimated cost
Bid Submission
02 Nov 2020
0 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
7500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Elakamon → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Jaljeevan Mission 2020 21Thiruvananthapuram District Replacement Of Damaged Ac And Pvc Pipes Extension Of Pipe Line And Providing House Connection In Elakamon Grama Panchayath

BOQ

Name of Work: JALJEEVAN MISSION 2020-21- Replacement of damaged AC& PVC pipes,Extension of pipe line and providing house connections in Elakamon Grama panchayath -part 2
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Appendix- A- Water connection to be given after line extension and Construction of valve chember
21.01Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil (Ref. Item No. 2.10.1 of DSR)BI01010001010000000000000515BI01000011153740cum
31.02Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals. (Data Prepared based on PWD SDB - Item No.1009)BI01010001010000000000000515BI01000011162000metre
41.03Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 90 mm nominal outer dia pipes.\"BI01010001010000000000000515BI01000011177500metre
51.04Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work80 mm dia nominal boreBI01010001010000000000000515BI0100001118400metre
61.05Supply of PVC Pipe, 6kg/cm2, 90mm Dia.BI01010001010000000000000515BI01000011197500metre
71.06Taking inter connection from 110/90/75/63 to 90mm line PVC distribution main a branch line using suitable size Tee (Tee connection only) and reducers including cost of materials labour charges etc completeBI01010001010000000000000515BI010000112030No
81.07Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)BI01010001010000000000000515BI010000112110cum
91.08Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm.BI01010001010000000000000515BI01000011229No
101.09\"Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :80 mm diameter. Class I\"Observed Data derived from item no.18.31.of DARBI01010001010000000000000515BI01000011239Nos
111.1Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.BI01010001010000000000000515BI01000011241404Nos
121.11Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers.BI01010001010000000000000515BI010000112525272metre
131.12Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers.BI01010001010000000000000515BI01000011261404Nos
141.13Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work15 mm dia nominal boreBI01010001010000000000000515BI0100001127600metre
151.14Charges for Geo taggingBI01010001010000000000000515BI01000011281404No
161.15Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soilBI01010001010000000000000515BI010000112915.21cum
171.16Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)BI01010001010000000000000515BI01000011301.522cum
181.17Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI01000011317.333cum
191.18Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.BI01010001010000000000000515BI010000113234.56sqm
201.19Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI0100001133586.4kilogram
211.212 mm cement plaster finished with a floating coat of neat cement of mix:BI01010001010000000000000515BI010000113438.88sqm
221.21Supplying and fixing CI MH Cover with frame (Heavy) with weight not less than 208 KgBI01010001010000000000000515BI01000011359No
232Appendix- B-water connection given after renovation of the scheme(replacing damaged pipe)BI01010001010000000000000515BI0100001136
242.01Dismantling of flexible pavement ( bituminous courses ) by mechanical means and disposal of dismantled material up to a lead of 1 kilo metre, as per direction of Engineer-in-charge.BI01010001010000000000000515BI010000113760cum
252.02Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil (Ref. Item No. 2.10.1 of DSR)BI01010001010000000000000515BI0100001138673.04cum
262.03Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :\"Ordinary Rock. (Ref. Item No. 2.13.1 of DSR)BI01010001010000000000000515BI0100001139120.96cum
272.04Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals. (Data Prepared based on PWD SDB - Item No.1009)BI01010001010000000000000515BI01000011401000metre
282.05Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials :200 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.17 in DARBI01010001010000000000000515BI01000011411000metre
292.06Labour for cutting C.I. pipe with steel saw.200 mm diameter C.I. pipeBI01010001010000000000000515BI010000114212Each Cut
302.07Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:200 mm dia pipesBI01010001010000000000000515BI0100001143132joint
312.08Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 200 mm diameter. Class II\" Data derived from item no.18.31.4.2of DARBI01010001010000000000000515BI01000011441Nos
322.09Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :100 mm diameter. Class II\" Data derived from item no.18.31.1.2of DARBI01010001010000000000000515BI01000011452Nos
332.1Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately):50 mm Double acting Air Valve Data derived from item no.18.59.1 of DARBI01010001010000000000000515BI01000011462Nos
343Construction of valve chember -Anchor block,culvert crossing and miscellaneous worksBI01010001010000000000000515BI0100001147
353.01Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soilBI01010001010000000000000515BI010000114821.348cum
363.02Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)BI01010001010000000000000515BI01000011491.807cum
373.03Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI010000115011.099cum
383.04Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concreteBI01010001010000000000000515BI010000115146.851sqm
393.05Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI0100001152647.2kilogram
403.0612 mm cement plaster finished with a floating coat of neat cement of mix:BI01010001010000000000000515BI010000115325sqm
413.07Supplying and fixing CI MH Cover with frame (Heavy) with weight not less than 208 KgBI01010001010000000000000515BI01000011545No
423.08Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.BI01010001010000000000000515BI01000011552cum
434cost of pipe and specialsBI01010001010000000000000515BI0100001156
444.01Supply of DI K9 Pipe Conforming to IS 8329/2000, 200mm Dia.BI01010001010000000000000515BI01000011571000metre
454.02Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 50mm.BI01010001010000000000000515BI01000011582No
464.03Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.0, Size 100mm.BI01010001010000000000000515BI01000011592No
474.04Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.0, Size 200mm.BI01010001010000000000000515BI01000011601No
484.05Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :BI01010001010000000000000515BI01000011619.66quintal
495Providing water connectionsBI01010001010000000000000515BI0100001162
505.01Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.BI01010001010000000000000515BI0100001163750Nos
515.02Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers.BI01010001010000000000000515BI010000116413500metre
525.03Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers.BI01010001010000000000000515BI0100001165750Nos
535.04Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work15 mm dia nominal boreBI01010001010000000000000515BI0100001166200metre
545.05Charges for Geo taggingBI01010001010000000000000515BI0100001167750No
555.06Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI010000116891.8cum

AI Tender Summary

OUR REF NO 25850224
AUTHORITY Local Bodies
TENDER VALUE 2.38 Crore
LAST DATE 02-11-2020
Authority
Authority Name Kerala Water Authority
Work Description Jaljeevan Mission 2020 21Thiruvananthapuram District Replacement Of Damaged Ac And Pvc Pipes Extension Of Pipe Line And Providing House Connection In Elakamon Grama Panchayath
Basic Detail
Tender No 87/2020-21/KWA/PHC/D1/TVM
Bidding Type Tender
Location
City Elakamon
State Kerala
Key Dates
Publish Date 28 Oct 2020
Submission Date 02 Nov 2020
Open Date 04 Nov 2020
Finance
Tender Value 2.38 Crore
Tender Fee 7500
EMD 1 Lakhs
Exemption Not Available
Document List
BOQ_562940.xls
C529F8E1-357B-48D6-B68D-C7EE9FA8AD73.html
nit87.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 28, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 04, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_562940.xls

html

C529F8E1-357B-48D6-B68D-C7EE9FA8AD73.html

pdf

nit87.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail