Project Description
Installation Of Street Lights For Chavakkad Municipality , Thrissurdistrict Installation Of Street Lights For ChavakkadMunicipality , Thrissurdistrict
BOQ
| Name of Work: INSTALLATION OF STREET LIGHTS FOR CHAVAKKAD MUNICIPALITY,THRISSUR DISTRICT | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | CIVIL WORK | BI01010001010000000000000515BI0100001113 | ||
| 2 | 1.01 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation\ntrenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil(2.8.1) | BI01010001010000000000000515BI0100001114 | 7.228 | cum |
| 3 | 1.02 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and\nshuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)(4.1.3) | BI01010001010000000000000515BI0100001115 | 2.369 | cum |
| 4 | 1.03 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of\ncentering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).(5.1.3) | BI01010001010000000000000515BI0100001116 | 6.624 | cum |
| 5 | 1.04 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete(5.9.1) | BI01010001010000000000000515BI0100001117 | 63.36 | sqm |
| 6 | 1.05 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more(5.22.6) | BI01010001010000000000000515BI0100001118 | 264.96 | kg |
| 7 | 1.06 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes(10.16.1) | BI01010001010000000000000515BI0100001119 | 493.058 | kg |
| 8 | 1.07 | Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work32 mm dia nominal bore(18.12.4) | BI01010001010000000000000515BI0100001120 | 5 | metre |
| 9 | 2 | ELECTRICAL WORKS | BI01010001010000000000000515BI0100001121 | ||
| 10 | 2.01 | Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 6 sq mm(90.12.37.32) | BI01010001010000000000000515BI0100001122 | 150 | metre |
| 11 | 2.02 | Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /recess conduit as required including giving necessary connections of the following sizes.2 core 1.50 sqmm(90.6.5.4) | BI01010001010000000000000515BI0100001123 | 320 | metre |
| 12 | 2.03 | Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 2core 2.5 sq mm(od187957/2020_2021) | BI01010001010000000000000515BI0100001124 | 1300 | metre |
| 13 | 2.04 | Supplying and making brass compression gland for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 6 sq. mm(od188029/2020_2021) | BI01010001010000000000000515BI0100001125 | 2 | set |
| 14 | 2.05 | Supplying and making brass compression gland for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 2.5 sq. mm(od188067/2020_2021) | BI01010001010000000000000515BI0100001126 | 74 | set |
| 15 | 2.06 | supply installation testing and commissioning of SMC IP-65 junction box of size 150x100x150mm (od188100/2020_2021) | BI01010001010000000000000515BI0100001127 | 32 | each |
| 16 | 2.07 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker\nsuitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole(2.10.1) | BI01010001010000000000000515BI0100001128 | 40 | each |
| 17 | 2.08 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 8 way, Double door(2.3.2) | BI01010001010000000000000515BI0100001129 | 1 | each |
| 18 | 2.09 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps(2.14.2) | BI01010001010000000000000515BI0100001130 | 1 | each |
| 19 | 2.1 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker\nsuitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole(2.10.3) | BI01010001010000000000000515BI0100001131 | 2 | each |
| 20 | 2.11 | Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required(od190716/2020_2021) | BI01010001010000000000000515BI0100001132 | 4 | set |
| 21 | 2.12 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)(90.16.1.3) | BI01010001010000000000000515BI0100001133 | 750 | metre |
| 22 | 2.13 | Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)(90.15.4.1) | BI01010001010000000000000515BI0100001134 | 32 | each |
| 23 | 2.14 | Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)(90.15.4.2) | BI01010001010000000000000515BI0100001135 | 32 | each |
| 24 | 2.15 | Supply, conveyance and errection of hot dip galvanized lamp pole fabricated of suitable size of 80 mm dia 'B' class GI pipe with suitable nuts, bolts & washers as required. The length of pole shall be 7 mtrs welded with base plate and 5 mtrs of 40 mm G.I circular tube may also be placed. The plate should be fixed in the proposed bed concrete and painting the entire post with 2 coats of matching colour synthetic enamel paint over a coat of zinc chromate primer as required(od127854/2020_2021) | BI01010001010000000000000515BI0100001136 | 32 | each |
| 25 | 2.16 | Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic meter box of following size suitable for fixing KSEB meter, fuse units, CT etc hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit. (Make: Safetek or equivalent)(od123253/2020_2021) | BI01010001010000000000000515BI0100001137 | 1 | each |
| 26 | 2.17 | KSEB charges for obtaining single phase service connection Including paper works and required the\nactual amount shall be reimbursed to the contractor only after obtaining single phase service connection\nand producing the original KSEB receipts.(od132151/2020_2021) | BI01010001010000000000000515BI0100001138 | 1 | job |
AI Tender Summary
Tender Timeline
Oct 28, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedNov 04, 2020