| 1 | 1 | P & Laying XLPE insulated IS:7098/II/85 of Group1 and approved make H.T.cable for working voltage 11 K.V.Earthed direct in ground including excavation of 30cmx100cm size trench, 25cm layer of river sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc.as required of size. 3 core 185.0 Sq.mm | | 680 | Mtr. |
|---|
| 2 | 2 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/joint kit of Group1 and approved make suitable for XLPE insulated 11 KV / 33 KV cable, with required components, prepration of cable ends,testing etc. as required of following sizes . 11 KV End Termination Kit Outdoor type 3 core 120/150/185/225 Sq.mm | | 16 | Set |
|---|
| 3 | 3 | P , Laying &Jointing R.C.C. class NP-2 (Non pressure) pipes (IS:458) with collars. Jointed with cement mortar of ratio 1:2 including excavation etc. as required. 300 mm dia internal. | | 50 | Mtr. |
|---|
| 4 | 4 | P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 185.0 Sq.mm 3.5 core Armoured | | 770 | Mtr |
|---|
| 5 | 5 | P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 10.0 Sq.mm 2 core Armoured | | 100 | Mtr. |
|---|
| 6 | 6 | P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 16.0 Sq.mm 4 core Armoured | | 100 | Mtr. |
|---|
| 7 | 7 | Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. 4 x 16.0 sq.mm | | 28 | Set |
|---|
| 8 | 8 | Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size 3.5 x 185.0 sq.mm | | 29 | Set |
|---|
| 9 | 9 | P / L of Double wall corrugated HDPE pipe confirming to IS : 14930 P - 1 & 2 with HDPE Coupler at 1 mtr. Depth below the ground for laying cable and back filling the trench , compaction of earth as required of Gemini or IS:14930 marked make. Outer Dia. / Inner dia. 50 /55 mm | | 100 | Mtr. |
|---|
| 10 | 10 | P / L of Double wall corrugated HDPE pipe confirming to IS : 14930 P - 1 & 2 with HDPE Coupler at 1 mtr. Depth below the ground for laying cable and back filling the trench , compaction of earth as required of Gemini or IS:14930 marked make. Outer Dia. / Inner dia. 120 / 103.5 mm | | 200 | Mtr. |
|---|
| 11 | 11 | Pipe Earthing as per IS:3043 with perforated 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300 mm and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance as required. | | 20 | Set |
|---|
| 12 | 12 | Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 25 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. | | 2 | Set |
|---|
| 13 | 13 | S & Laying following size' B ' class G.I. Pipe confirming to IS : 1239 P - 1 ( 1990 ) with accessories for laying earth conductor/strip / cable in ground/surface/recess as required 100 mm dia. | | 90 | Mtr. |
|---|
| 14 | 14 | SITC of 11 KV, 400/630 A, 20kA / 3 sec, Out door / Indoor, Extensible / Non Extensible type Ring main unit (RMU) in suitable RCC foundation with 2 no. Load break switch & 1 no. VCB / SF6 circuit breaker with over load, Earth fault, short circuit relay, copper bus bar, ring core protection & metering CT, Auxiliary relay for WTI, OTI ,Bucholz alarm & trip along with annuciator panel , master trip relay, mechanical ON / OFF / Earth indication, Voltage presence indicator, 24 V DC Shunt trip coil with power pack, Anti reflex operating handle, right angle boots etc. as required. | | 1 | Set |
|---|
| 15 | 15 | Add @ 50/- p.m. if trench excavation in C.C. flooring / Tar road | | 1000 | Each |
|---|
| 16 | 16 | S & F of IP - 65 protected impact resistant polycarbonate / Polysterene enclosures of following sizes. 300 x 450 x 132 mm | | 11 | Each |
|---|
| 17 | 17 | S & F of IP - 65 protected impact resistant polycarbonate / Polysterene enclosures of following sizes. 320 x 640 x 179mm | | 11 | Each |
|---|
| 18 | 18 | P&F following size aluminium bus bar on insulators at approved spacing in existing bus bar chamber including making holes etc. as required 50 x 6 mm\n | | 60 | Mtr. |
|---|
| 19 | 19 | Supply and erection of P.C.C./R.C.C. pole as per REC manual no 15/1979 conforming to IS: 2905/1966 including excavation of pit and back filling with stone aggregate/boulders and soil in 0.45m consolidating each deposited layer of 0.45m by ramming and watering etc complete in all respect. 9.0 Mtr long (200 Kg ) as per Discom specification | | 11 | Each |
|---|
| 20 | 20 | ?????:- \n1) ????? ??? (????) ?????? ??? ???? ?? ????? ?? ????? ???? ?? ?????? ?? ???? ???? ?? ?????????? ?????? ?? ?????\n2) ????? ?? ????? ????? ?? ???? ??.??.??. ?? ????? ??? ????? \n3) ????? ?? ????? ???? ?? ?????? ?? ???? ?? ???? ???? ????? ???? ?? ?????? ?????? ?? ?????????? ?????? ?? ????? ????? ?????? ??? ??? ????? \n3) ??.??. ?? ???? ??? ?? ??? ?? ???? ???? ???\n | | | |
|---|