| 1 | 1 | Providing, Installing, Testing and Commissioning of ‘Silent Type’ Diesel Generating set along with having Prime Power Rating of 380 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor with standard control panel and copper control cable of length upto 15 mtr from DG set to AMF panel and consisting of the followings: (a) Diesel Engine : Diesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fi tted complete with all the required accessories. (b) Alternator : Synchronous alternator rated at 380 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class- F/H insulation. (c) Engine mounted instrument panel As per OEM \n(d) Base Frame As per OEM. (e )Fuel Tank: As per OEM. (f) Exhaust System: As per OEM (g) Starting System: As per OEM (h) Acoustic & weather proof Enclosure As per OEM (CPCB-II Norms ) | BI01010001010000000000000515BI0100001113 | 1 | Set |
|---|
| 2 | 2 | Providing, Installing, Testing and Commissioning of ‘Silent Type’ Diesel Generating set along with having Prime Power Rating of 62.5 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor with standard control panel and copper control cable of length upto 15 mtr from DG set to AMF panel and consisting of the followings: \n(a) Diesel Engine : Diesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fi tted complete with all the required accessories. (b) Alternator : Synchronous alternator rated at 62.5 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class- F/H insulation. \n(c) Engine Mounted instrument Panel As per OEM. (d) Base Frame As per OEM. (e ) Fuel Tank: As per OEM (f) Exhaust System: As per OEM. (g) Starting System: As per OEM (h) Acoustic & weather proof Enclosure As per OEM (CPCB-II Norms ) | BI01010001010000000000000515BI0100001114 | 2 | Set |
|---|
| 3 | 3 | Providing, Installing, Testing and Commissioning of ‘Silent Type’ Diesel Generating set along with having Prime Power Rating of 45 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor with standard control panel and copper control cable of length upto 15 mtr from DG set to AMF panel and consisting of the followings: \n(a) Diesel Engine : Diesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fi tted complete with all the required accessories. (b) Alternator : Synchronous alternator rated at 45KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class- F/H insulation. \n(c) Engine mounted Instrument panel As per OEM (d) Base Frame \nAs per OEM (e )Fuel Tank: As per OEM (f) Exhaust System: As per OEM (g) Starting System: As per OEM (h) Acoustic & weather proof Enclosure As per OEM (CPCB-II Norms ) | BI01010001010000000000000515BI0100001115 | 2 | Set |
|---|
| 4 | 4 | SITC of AMF panels outdoor type (double door ) with manual by pass arrangement made out of CRCA sheet (2/1.6 mm thick) involving 9 tank process , powder coated (minimum 50-70 micron) in IVORY colour shade of semi gloss finish , EP DM gaskets of suitable shape & size at doors /windows /covers /joints to make the panel dust & vermin proof suitable to operate of 415 volts , 3 phase , 4 core wire, 50 Hz AC supply system of following rating /capacities :- \n380 KVA , AMF with manual by pass arrangment :- Supply/Incomer a) 630 Amp -36 KA , manually operated MCCB -01 No. b) 600 amp , four pole contactor ,(AC 1 duty )-01 No. DG/Incomer a) 630 amp , 36 kA manually operated MCCB -01 No. b) 600 amp , four pole contactor ,(AC 1 duty )-01 No. ON load changeover switch 630 amp four pole ON load changeover switch -02 Nos. (for By pass arrangement ) Metering & AMF logic a) 630 amp capacity four pole Aluminium bus bar -01 set b) Analog ammeter ,0-30 amp (DC) size 72 mm X 72 mm -01 No. c) Analog voltmeter ,0-30 volt (DC ) size 72 mm X 72 mm -01 No. d) Selector switch (ASS, VSS ) -2 Nos. e) SMPS based electonic battery charger 24 volt DC of 16 Amp capacity- 01 Nos. f) Voltage monitoring Relay --01 No. g) Push button (DG start /Stop) --03 No. h)Indication Lamp (LED type) -- 04 No. i) SPMCB 6/10 Amp 02 No. \nOUTGOING \na) 630 Amp -36 KA , manually operated MCCB -01 No. | BI01010001010000000000000515BI0100001116 | 1 | Each |
|---|
| 5 | 4.01 | 62.5 KVA , AMF with manual by pass arrangment :- Supply/Incomer a) 100 Amp -25 KA , manually operated MCCB -01 No. b) 100 amp , four pole contactor ,(AC 1 )-01 No. DG/Incomer a) 100 amp , 25 KA manually operated MCCB -01 No. b) 100 amp , four pole contactor ,(AC 1 Duty )-01 No. ON load changeover switch 100 amp four pole ON load changeover switch -02 Nos. ( for By pass arrangement ) Metering & AMF logic a) 100 amp capacity four pole Aluminium bus bar -01 set b) Analog ammeter ,0-30 amp (DC) size 72 mm X 72 mm -01 No. c) Analog voltmeter ,0-30 volt (DC ) size 72 mm X 72 mm -01 No. d) Selector switch (ASS, VSS ) -2 Nos. e) SMPS based electonic battery charger 12 volt DC of 10 Amp capacity- 01 Nos. f) Voltage monitoring Relay --01 No. g) Push button (DG start /Stop) --03 No. h)Indication Lamp (LED type) -- 04 No. i) SPMCB 6/10 Amp 02 No. \nOUTGOING \na) 100 Amp -25 KA , manually operated MCCB -01 No. | BI01010001010000000000000515BI0100001117 | 2 | Each |
|---|
| 6 | 4.02 | 45 KVA , AMF with manual by pass arrangment :- Supply/Incomer a) 80 Amp -25 KA , manually operated MCCB -01 No. b) 80 amp , four pole contactor ,(AC 1 )-01 No. DG/Incomer a) 80 amp , 25 KA manually operated MCCB -01 No. b) 80 amp , four pole contactor ,(AC 1 Duty )-01 No. ON load changeover switch 100 amp four pole ON load changeover switch -02 Nos. (for By pass arrangement ) Metering & AMF logic a) 80 amp capacity four pole Aluminium bus bar -01 set b) Analog ammeter ,0-30 amp (DC) size 72 mm X 72 mm -01 No. c) Analog voltmeter ,0-30 volt (DC ) size 72 mm X 72 mm -01 No. d) Selector switch (ASS, VSS ) -2 Nos. e) SMPS based electonic battery charger 12 volt DC of 10 Amp capacity- 01 Nos. f) Voltage monitoring Relay --01 No. g) Push button (DG start /Stop) --03 No. h)Indication Lamp (LED type) -- 04 No. i) SPMCB 6/10 Amp 02 No. \nOUTGOING \na) 80 Amp -25 KA , manually operated MCCB -01 No. | BI01010001010000000000000515BI0100001118 | 2 | Each |
|---|
| 7 | 5 | Supplying, installation, testing & commissioning of cubical type floor mounted Emergency Common panel suitable for 433 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for frame work and openable covers on front side, 3 mm thick for gland, plates i/c cleaning & fi nishing complete with 7 tank process for powder coating in approved shade, having 800 amp capacity TPN aluminium alloy bus bars of hight conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec.,with bottom at a height of 0.5m from floor lvl., fabricated with channel of MS section not less than 100 mm x 50 mm x 5 mm thick, entire panel shall have a common aluminium earth bar of size 25 mm x 10 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, 7 nos. cable gland plates in two half, i/c providing following switch gears. \nIncoming : (a) MCCBs 4 pole 1 cs = KA upto 433 volts 400 Amp 50 KA - 4 Nos. (for BSES supply) 630 Amp 50 KA - 1 Nos. (for DG supply) (b) Analog 96 mm square flush pattern / Digital type Voltmeter (0-500 V), with selector switch & back up HRC fuses/MCBs-5 sets. (c) Analog 96 mm. square fl ush pattern/Digital type Ammeter (0- 400 Amp), with selector switch and one set of 3 nos. CT’s of ratio 300/5A Class I accuracy and 15 VA burden- 4 sets. (d) Analog 96 mm. square fl ush pattern/Digital type Ammeter (0- 600 Amp), with selector switch and one set of 3 nos. CT’s of ratio 300/5A Class I accuracy and 15 VA burden- 1 sets. (e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 6 A HRC fuse/MCB, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 5 sets (f) Bus Bars : TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. Outgoing : (a) 400 Amp four pole ATS - 2 Nos. (b) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse/MCB, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 sets | BI01010001010000000000000515BI0100001119 | 1 | Set |
|---|
| 8 | 6 | Supply of XLPE PVC insulated PVC sheathed Aluminium armoured cable for working 7098 voltage upto 1.1 KV confirming to IS:1554 (Part-1) 1988 \n(a) 4.0 x 50 sqmm | BI01010001010000000000000515BI0100001120 | 200 | Mtr |
|---|
| 9 | 6.01 | (b) 3.5 x 300 sqmm | BI01010001010000000000000515BI0100001121 | 150 | Mtr |
|---|
| 10 | 7 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 3½ X 300 sqmm | BI01010001010000000000000515BI0100001122 | 4 | Each |
|---|
| 11 | 7.01 | (b) 4.0 x 50 sqmm | BI01010001010000000000000515BI0100001123 | 16 | Each |
|---|
| 12 | 8 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in on wall surface as required. \n(a) Above 185 sq. mm and upto 400 sq mm | BI01010001010000000000000515BI0100001124 | 100 | Mtr |
|---|
| 13 | 8.01 | (b) Above 35 sq. mm and upto 95 sq mm | BI01010001010000000000000515BI0100001125 | 150 | Mtr |
|---|
| 14 | 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. \n(a) Above 185 sq. mm and upto 400 sq. mm | BI01010001010000000000000515BI0100001126 | 100 | Mtr |
|---|
| 15 | 9.01 | (a) Above 35 sq. mm and upto 95 sq. mm | BI01010001010000000000000515BI0100001127 | 150 | Mtr |
|---|
| 16 | 10 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | BI01010001010000000000000515BI0100001128 | 4 | Set |
|---|
| 17 | 11 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) | BI01010001010000000000000515BI0100001129 | 15 | Mtr |
|---|
| 18 | 12 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. | BI01010001010000000000000515BI0100001130 | 15 | Mtr |
|---|
| 19 | 13 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. | BI01010001010000000000000515BI0100001131 | 20 | Mtr |
|---|
| 20 | 14 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | BI01010001010000000000000515BI0100001132 | 16 | Mtr |
|---|
| 21 | 15 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm). | BI01010001010000000000000515BI0100001133 | 60 | Mtr |
|---|
| 22 | 16 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. | BI01010001010000000000000515BI0100001134 | 60 | Mtr |
|---|
| 23 | 17 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. | BI01010001010000000000000515BI0100001135 | 60 | Mtr |
|---|