| 1 | 0 | SCHEDULE 'A' | BI01010001010000000000000515BI0100001112 | | |
|---|
| 2 | 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and as directed by Engineer-in-charge. | | 50 | Cum |
|---|
| 3 | 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm hard/dense soil all complete all as specified and as directed by Engineer-in-charge. | | 28 | Cum |
|---|
| 4 | 3 | Removal of surplus soil of distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and as directed by Engineer-in-charge. | | 22 | Cum |
|---|
| 5 | 4 | M&L Plain Cement concrete type D-2, (1:4:8 using 40mm graded stone aggregates) as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge. | | 12 | Cum |
|---|
| 6 | 5 | M&L Plain Cement concrete type C-1, (1:3:6, using 20mm graded stone aggregates) as in Coping complete all as specified and as directed by Engineer-in-charge. | | 3 | Cum |
|---|
| 7 | 6 | M&L Pre-cast cement concrete block masonry type C1 (1:3:6, using 20 mm graded stone aggregates) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and as directed by Engineer-in-charge. | | 42 | Cum |
|---|
| 8 | 7 | All as per Item No-06 but except concrete block complete all as specified and as directed by Engineer-in-charge. | | 2 | Cum |
|---|
| 9 | 8 | M&L 12mm thick Plywood, grade BWP, type BB fixed with screws to timber framework complete all as specified and as directed by Engineer-in-charge. | | 170 | Sqm |
|---|
| 10 | 9 | M&L 25 mm thick Plain Cement concrete type B-0, (1:2:4,using 12.50mm graded stone aggregates) as in sub base of flooring complete all as specified and as directed by Engineer-in-charge. | | 250 | Sqm |
|---|
| 11 | 10 | M&L 20 mm thick Granite as in floors, machine cut, bedded and jointed with laid and jointed with grey cement slurry, 15mm thick screed bed of cement mortar (1:4) and pointed with white cement with admixture of pigment to match the shade of granite slab including dismantling of old broken stone slab complete all as specified and directed by EIC\n | | 150 | Sqm |
|---|
| 12 | 11 | M&L Glazed coloured ceramic tiles in vertical surfaces 300 x 450 x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 10mm thick rendering on fair faces of brick work in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. | | 720 | Sqm |
|---|
| 13 | 12 | M&L Non-skid Joint free Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchand including 15mm screed bed or bedding layer in 1:6 CM complete all as specified and as directed by Engineer-in-Charge. | | 250 | Sqm |
|---|
| 14 | 13 | M&L Rendering 15 mm thick in cement mortar 1:4 on fair faces of PCC block masonry and finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. | | 910 | Sqm |
|---|
| 15 | 14 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed by Engineer-in-charge.. | | 1310 | Sqm |
|---|
| 16 | 15 | M&L Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of Chalk whiting, complete all as specified and as directed by Engineer-in-charge.. | | 200 | Sqm |
|---|
| 17 | 16 | M&L Preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of Chalk whiting, complete all as specified and as directed by Engineer-in-charge.. | | 200 | Sqm |
|---|
| 18 | 17 | S&F 5mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and as directed by Engineer-in-charge.. | | 60 | Sqm |
|---|
| 19 | 18 | M&L Granules textured homogeneous wall finishing system consisting of a two component system of dry granules (25 Kg per Pack) made of 92% silica particles coated with fade resistant pigment, 100% acrylic polymer bonding agent (5 Kg per pack) with the applied thickness of the coating being between 0.8mm -1.2mm to be applied on curved, smooth level plaster without key, as per manufacture directions, for usages to be applied and approved applicator of the manufacture as per the direction/ supervision of the Engineer-in-charge, all complete. The above textured coating should conform to surface spread of flame class one of BS 476:Part 7:1971 and pull off strength of the coating to meet JISA 6909 on smooth plastered surfaces complete all as specified and as directed by Engineer-in-charge.\nMake:- Bakelite Hylam Limited or equivalent make approved by the GE.\n | | 240 | Sqm |
|---|
| 20 | 19 | M&L One mm thick decorative laminate/sunmica exotic design and superior quality and durability fixed on plywood with adhesive complete all as specified and as directed by Engineer-in-charge.\nNote: The colour of lamination shall be as selected by the Engineer-in-charge | | 170 | Sqm |
|---|
| 21 | 20 | S&F Stainless steel pipe of grade 316, of any dia for railling / balusters over existing parapet including base, collars, caps, head caps and anyother specials etc including necessary welding, polishing and drilling in masonary and filling with epoxy grout etc complete all as specified and directed by Engineer in charge. | | 1950 | Kg |
|---|
| 22 | 21 | Demolition of Brickwork or stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and as directed by Engineer-in-charge.. | | 14 | Cum |
|---|