| 1 | 1 | Demolition of cement Concrete (unreinforced in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. | | 2 | Cum |
|---|
| 2 | 2 | Demolition of cement Concrete (Reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. | | 5 | Cum |
|---|
| 3 | 3 | Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings complete all as specified and directed. | | 5 | Cum |
|---|
| 4 | 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. | | 2.5 | Qtl |
|---|
| 5 | 5 | M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work including pintle hinges, stops, hand made sliding bolts etc with ornamental and intricate design con- forming to Fe.290.Gde-E-165 Complete all as specified and as directed. | | 450 | Kg |
|---|
| 6 | 6 | M&L for Mild steel, plain, black sheet 1mm thick in wall cladding, steel gates and similar work, cut to size, holes punched, including round headed screws, clout mails or rivets and fixed to steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles etc as required Complete all as specified and as directed by Engineer-in-Charge. | | 40 | Sqm |
|---|
| 7 | 7 | M&L for preparation of new surfaces of steel or iron over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer Complete all as specified and as directed. | | 120 | Sqm |
|---|
| 8 | 8 | M&L for preparation of old painted surfaces of steel and iron over 10cm width or grith and applying one coat of synthetic enamel paint complete all as specified and directed. | | 110 | Sqm |
|---|
| 9 | 9 | M&L for writing letters or figures (Block, Roman, Italic or Indian) n.exc. 30 cm high on building/ board with synthetic enamel paint. Complete all as specified and as directed. | | 8 | 10 Nos |
|---|
| 10 | 10 | M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite Complete all as specified and as directed. | | 20 | Sqm |
|---|
| 11 | 11 | M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations | | 50 | RM |
|---|
| 12 | 12 | S&F Indian Air force logos of approximate size 0.60 m diameter made with stainless steel complete all as specified and as directed by Engineer-in-Charge. | | 4 | Each |
|---|
| 13 | 13 | M & L for welding in repair not exc 2.5cm in length and thickness of metal to be welded exc 6mm and not exc 9mm incl repair to iron gate roller complete all as specified and directed. | | 30 | Each |
|---|
| 14 | 14 | M & L for welding in repair exc 2.5cm and not exc 5cm in length and thickness of metal to be welded exc 6mm and not exc 9mm incl repair to iron gate roller complete all as specified and directed. | | 20 | Each |
|---|
| 15 | 15 | M&L for Hard core with broken stone of gauge not exc. 63mm deposited spread and levelled in layers not exc.15cm thick complete all as specified and directed. | | 5 | Cum |
|---|
| 16 | 16 | M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and directed. | | 12 | Cum |
|---|
| 17 | 17 | M&L for reinforced cement concrete (design mix) (M-25) using 20mm graded stone aggregate as in slabs supported on walls, beams and coloumns in floor, roof, landing, balconies, canopies, deck slabs and in shelves and similar work complete all as specified and directed. | | 4 | Cum |
|---|
| 18 | 18 | M&L for reinforced cement concrete (design mix) (M-25) using 20mm graded stone aggregate as in foundations, including rafts, footings, foundation beams, bases for coloumn, etc basement slabs, under-reamed piles and mass concrete complete all as specified and directed. | | 8 | Cum |
|---|
| 19 | 19 | M&L for reinforced cement concrete (design mix) (M-25) using 20mm graded stone aggregate as in columns, pillars, pier posts etc complete all as specified and directed. | | 2 | Cum |
|---|
| 20 | 20 | M&L for reinforced cement concrete (design mix) (M-25) using 20mm graded stone aggregate as in beam, cantilevers, bressummers, lintel over 1.5m span and similar work complete all as specified and directed. | | 2 | Cum |
|---|
| 21 | 21 | M&L for reinforced cement concrete (design mix) (M-25) using 20mm graded stone aggregate as in chajjas complete all as specified and directed. | | 1 | Cum |
|---|
| 22 | 22 | Formwork to sides of concrete foundations,footings, base of columns, raft and raft beams, side and soffits of foundations ,plinth beams and similar work vertical or to batter complete all as specified and directed. | | 85 | Sqm |
|---|
| 23 | 23 | Formwork to side of pillars, posts struts, piers, columns and stanchions complete all as specified and directed. | | 40 | Sqm |
|---|
| 24 | 24 | Formwork to sides and soffits of floor or roof beams haunchings, girders, bressummers, bands, cantilevers, shelves including sup-ports overhangs, etc also splays between floor and beams etc complete all as specified and directed. | | 15 | Sqm |
|---|
| 25 | 25 | Formwork to sides and soffits of suspended slabs such as roof slabs, floor slabs,, landings and similar works, not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. | | 10 | Sqm |
|---|
| 26 | 26 | Formwork to sides and soffits of chajjas, troughs and similar items including edges complete all as specified and directed. | | 5 | Sqm |
|---|
| 27 | 27 | M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal for sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. | | 10 | RM |
|---|
| 28 | 28 | M&L for TMT bars, 10mm dia and over, cut to length, bend to shape required including cranking bending spirally for hooping for columns hooking and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. | | 800 | Kg |
|---|
| 29 | 29 | All as per item No 28.00 above but 6mm to 8mm dia bars. | | 75 | Kg |
|---|
| 30 | 30 | All as per item No 28.00 above but 5mm dia and over upto and including 10mm dia in strirrups | | 160 | Kg |
|---|
| 31 | 31 | M&L for precast cement concrete block masonry with solid blocks of type C-1, 1:3:6 using 20mm graded aggregate, exc 10cm in width and setting in CM 1:6 complete all as specified and directed. | | 15 | Cum |
|---|
| 32 | 32 | M&L for 10mm thick cement plasters in CM 1:6 on concrete or brick wall surfaces including finishing even & smooth with out using extra cement complete all as specified and directed. | | 50 | Sqm |
|---|
| 33 | 33 | M&L for 15 mm rendering in two layers with first layer of 10 mm thick in CM 1:6 & second layer of 5 mm thick in CM (1:4) with using water proffing compound on fair face of wall or on concrete surfaces including finishing even and smooth without using extra cement complete all as specified and directed.\nNote : WPC will be measured and paind seprately. | | 40 | Sqm |
|---|
| 34 | 34 | M&L for 5 mm thick cemet plaster on ceilling surfaces in CM 1:3 finished even and smooth complete all as specified and directed. | | 10 | Sqm |
|---|
| 35 | 35 | Supply only Water Proofing Compound ISI Marked complete all as specified and directed. | | 10 | Kg |
|---|
| 36 | 36 | M&L for preparing plastered surfaces of walls/ceiling and applying two coats of birla white cement putty for finishing the surfaces to even and smooth and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and directed. | | 20 | Sqm |
|---|
| 37 | 37 | M&L for Preparation of newly plastered or unplastered wall surfaces and applying two coats of exterior ACRYLIC Emulsion paint (Colour or shade as approved by GE) over and including one coat of primer as per manufactures instruction complete including claeaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and keeping premise clean and tidy complete all as specified and directed by Engineer-in-Charge. | | 50 | Sqm |
|---|
| 38 | 38 | M&L preparing the new plaster surface of ceiling, soffits of chajjas and applying 3 coats of white wash complete all as specified and directed. | | 10 | Sqm |
|---|
| 39 | 39 | S&F PVC (SWR) pipes 110 mm bore single socketed in any lengths with rubber ring joints laid in trenches or in floors or on walls complete all as specified and directed. | | 40 | RM |
|---|
| 40 | 40 | All as per item No 39.00 above but 75 mm bore pipes | | 2 | RM |
|---|
| 41 | 41 | S&F PVC (SWR) bends of any radius 110 mm bore complete all as specified and directed. | | 5 | Each |
|---|
| 42 | 42 | S&F PVC (SWR) floor trapplain with grating incl jointing with solvent cement, 75 mm dia outlet complete all as specified and directed. | | 2 | Each |
|---|
| 43 | 43 | S&F PVC (SWR) Gully trap 125/110 mm setting & jointing with solvent and cement complete all as specified and directed. | | 2 | Each |
|---|
| 44 | 44 | Providing and fixing of Sign board made out of 3mm thick aluminium composite panel of size 90x90 cms. Octagon as per the design of IRC-67-2010, reslectorised with retro Micro Prismatic non metalic polycaorbonate base sheeting as per latest M.O.S.T specification, 3.1m long stand post and frame fabricated from suitable size angle of 35x35x4mm /NB 65MS pipe as required, painted with best quality epoxy coating in black and white bands. The details of symbol for each boards shall be as per the instruction of Engr-in-Charge. The fixing at site shall be in (1:2:4) PCC block size 45x45x60cms for eadh leg including excavation curing etc as specified and as directed by Engr-in-Charge. | | 2 | Each |
|---|
| 45 | 45 | M&L writing letters or figures (Block, Roman, Italic or Indian) exc. 30 cm and exc 40 cm height 7.5 cm wide and 3cm thick made of polished brass metal sheet 2mm thick including fixing with chemical solution on vertical concrete/stone surface all as specified and as directed. | | 30 | Each |
|---|
| 46 | 46 | M/L PCC (1:4:8) type D2 using 40 mm graded aggregate as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they laid and tested for bore of pipe 110 mm complete all as specified and directed. | | 30 | RM |
|---|
| 47 | 47 | M/L PCC (1:3:6) type C1 using 20 mm graded aggregate as in coping, benching and similar works including forms etc and finishing the surface even and smooth complete all as specified and directed. | | 0.5 | Cum |
|---|
| 48 | 48 | S&F Steel porta cabin consisting one room of size (6.00x3.00x2.90m), one toilet of size (1.80x1.20x2.90m) and one pantry of size (1.20x1.20x2.90m). The portable cabins shall consist wall/side panel, false ceiling and roof sheet with framed steel structure. The bottom frame stracture shall be of MS section 100x50x4mm thick. Side panel frame made of MS section 40x20x3.2mm thick placed at c/c distance not exceeding 3m. The roof frame made of MS section 40x20x3.2mm thick. Two coats of synthetic enamel paint over a coat of primer to be applied on exposed structure of MS items after installation. Wall panel shall have consist of 4mm thick water proof board on both sides with 30 mm thick high density thermocol insulation in between and shall be fire retardant, termite and pest proof, eco friendluy, 100% recyclable. External surface of wall panels shall be covered with 1.25mm thick prepainted Galvanized steel sheet and internal surface of wall panel shall be painted with two coats of OBD over a coat of primer. The roof sheet is of 1.25mm thick prepainted Galvanized steel sheet properly sloped and water tight. False ceiling shall be of 4mm waterproof board aluminium composite panel fire retardant, termite and pest proof, eco friendly, 100% recyclable all as specified and as directed by Engineer-in-Charge.\nNote : The porta steel cabins shall be fixed on RCC columns / brick work as per manufacturer instructions.\nMake : Reliable cabin/ Zinto cabin/ Rida portable cabin | | 2 | Each |
|---|
| 49 | 49 | Surface excavation not exc 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed by engr-in charge. | | 80 | Sqm |
|---|
| 50 | 50 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m deep and getting out in hard /dense soil complete all as specified and directed by engr-in charge. | | 15 | Cum |
|---|
| 51 | 51 | Returning, filling in excavated soil including spreading leveling, watering and well ramming in layers n.exc 25cm thick each complete all as specified and directed. | | 5 | cum |
|---|
| 52 | 52 | Removing excavated surplus soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting points complete all as specified and directed by engr-in charge. | | 10 | cum |
|---|
| 53 | 53 | M&L for shingle filling in floors or pavings, laid in layers n.exc 15 cm thick spread, levelled and blinded with earth and rammed incl watering complete all as specified and directed. | | 4 | Cum |
|---|
| 54 | 54 | M&L for 25mm thick cement concrete type BO 1:2:4 using 12.5mm graded aggregate as in floors complete all as specified and directed. | | 200 | Sqm |
|---|
| 55 | 55 | M&L for 75 mm thick cement concrete type B2 1:2:4 (using 40 mm graded aggregate) in sub base of floors complete all as specified and directed. | | 200 | Sqm |
|---|
| 56 | 56 | M&L for 75 mm thick cement concrete type C2 1:3:6 ( using 40 mm graded aggregate) as in plinth protection complete all as specified and directed. | | 90 | Sqm |
|---|
| 57 | 57 | M&L Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished (doubly charged), area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 20mm thcik screed bed in CM 1:6 complete all as specified and directed. | | 40 | Sqm |
|---|
| 58 | 58 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification complete all as specified and directed. | | 10 | RM |
|---|
| 59 | 59 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC 'C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plan colour PVC sheets for top rail, lock rai & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site complete all as specified and directed. | | 3 | Sqm |
|---|
| 60 | 60 | S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, and both faces covered with decorative face veneer with lipping/frame to match complete all as specified and directed. | | 8 | Sqm |
|---|
| 61 | 61 | M&L for anodised aluminium sections in frames and shutters powder coated for windows, ventilators with one or more rebates including joining cleat for fixing complete all as specified and directed. | | 40 | Kg |
|---|
| 62 | 62 | S&F 4mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares n exc 0.5 sqm in each pane complete all as specified and directed. | | 5 | Sqm |
|---|
| 63 | 63 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with Aluminium beads to aluminium shutter, tinned tacks, or galvanised wire staples or wooden beads complete all as specified and directed. | | 3 | Sqm |
|---|
| 64 | 64 | S&F 150mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. | | 8 | Each |
|---|
| 65 | 65 | S&F 100mm Butt hinges medium weight, cold rolled mild steel complete all as specified and directed. | | 12 | Each |
|---|
| 66 | 66 | S&F 75mm size anodised aluminium handle cast type complete all as specified and directed. | | 8 | Each |
|---|
| 67 | 67 | S&F mortice lock Mild steel vertical type size 100mm 2 levers fixed to wooden or Aluminium door shutters complete all as specified and directed. | | 4 | Each |
|---|
| 68 | 68 | S&F SS tubular towel rail 20mm dia 60cm long with brackets complete all as specified and directed. | | 2 | Each |
|---|
| 69 | 69 | S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor over all length 150mm complete all as specified and directed. | | 4 | Each |
|---|
| 70 | 70 | S&F Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. | | 4 | Each |
|---|
| 71 | 71 | S&F Rotational moulded polyethylene water storage tanks 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. | | 2 | Each |
|---|
| 72 | 72 | S&F in repair 25mm size Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. | | 2 | Each |
|---|
| 73 | 73 | Supply and laying of CPVC 20mm dia pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. | | 30 | RM |
|---|
| 74 | 74 | S&F 20mm CPVC Brass Elbow complete all as specified and as directed. | | 8 | Each |
|---|
| 75 | 75 | S&F 20mm CPVC Brass Elbow (3/4 X ½) complete all as specified and as directed. | | 10 | Each |
|---|
| 76 | 76 | S&F 20mm CPVC Brass Tee complete all as specified and as directed. | | 6 | Each |
|---|
| 77 | 77 | S&F 20mm CPVC Male Brass Threaded Adaptor (MTA/ MBTA) complete all as specified and as directed. | | 2 | Each |
|---|
| 78 | 78 | S& F 20mm CPVC Female Brass Threaded Adaptor (FTA/ FBTA) complete all as specified and as directed. | | 2 | Each |
|---|
| 79 | 79 | S& F 20mm CPVC Tank Adaptor complete all as specified and as directed. | | 2 | Each |
|---|
| 80 | 80 | S&F 20 mm CPVC UNION complete all as specified and as directed. | | 2 | Each |
|---|
| 81 | 81 | S&F 25mm bore tubes medium grade galvanised with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed. | | 30 | RM |
|---|
| 82 | 82 | S&F 15 mm bore bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. | | 4 | Each |
|---|
| 83 | 83 | S&F 15 mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. | | 6 | Each |
|---|
| 84 | 84 | S&F in repairs, grating square 150mm size of PTMT (minimum weight 100 gms ) complete all as specified and directed. | | 2 | Each |
|---|
| 85 | 85 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. | | 4 | Each |
|---|
| 86 | 86 | S&F 15mm Angular stop cock cast coper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed | | 4 | Each |
|---|
| 87 | 87 | S&F Vitreous China wash basin, white flat back, size 580x450mm including waste coupling, waste pipe and bracket for erecting stand complete all as specified and directed. | | 2 | Each |
|---|
| 88 | 88 | S&F 15mm dia pillar taps fancy type with capstan heads chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shank and fly-nut, screwed for iron pipe and fixed for 15mm dia of pipe complete all as specified and directed. | | 2 | Each |
|---|
| 89 | 89 | S&F PVC connection 15mm dia with PTMT nut of length 450mm long complete all as specified and directed. | | 4 | Each |
|---|
| 90 | 90 | Supply & fixing cast iron nahani trap 75mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B-1(1:2:4) complete all as specified and directed. | | 2 | Each |
|---|
| 91 | 91 | S&F Vitreous China soap tray of approximate size 160x160x90mm embedded in the wall complete all as specified and directed. | | 2 | Each |
|---|
| 92 | 92 | S&F Vitreous China wash down water closet pan (pedestal pattern), white with plastic water closet seat closed pattern and cover and chromium plated hinging device including fixing bolts, and flush pipe complet all as specified and directed. | | 2 | Each |
|---|
| 93 | 93 | S&F 10 litres capacity PVC low level, valveless. Syphonic action type, flushing cistern, with inlet, ball valve, float and handles and brackets complete all as specified and directed. | | 2 | Each |
|---|
| 94 | 94 | S&F flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed. | | 2 | Each |
|---|
| 95 | 95 | Material and labour for concrete bed to drain pipes of 200 mm bore in cement concrete (1:3:6) type C2, (using 40mm graded stone aggregate) including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. | | 42 | RM |
|---|
| 96 | 96 | Material and labour extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/stopped ends etc complete all as specified and directed.(Inner girth shall only be measured). | | 20 | RM |
|---|
| 97 | 97 | M&L for cutting into existing manholes for connectng new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate)smooth finished and reforming benching as required for 150mm bore pipe complete all as specified and directed by engr-in charge. | | 4 | Each \nPipe |
|---|
| 98 | 98 | Material and labour for point wiring with using 1.5 Sq mm (nominal area) stranded copper conductor single core, PVC insulated & unsheathed cable, (FRLS) 1100 volts grade with and including PVC surface conduit (medium grade) of suitable size all as specified and directed with using new sunken type pressed steel box/terminal boxes for mounting fittings not less than 1.6 mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer with and incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable (FRLS) as in earth wire connected to common earth dolly complete all as specified and directed for the following:-\nNote : (i) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for seperatly of Sch’A’. \n(ii) The size of conduits shall be determined on permissible No of runs of wires as specified in SSR part I (2010) However minimum size of conduits shall be 20 mm dia (medium grade). \n\n | | | |
|---|
| 99 | 98.01 | One light point controlled by one one/way switch. | | 34 | Point |
|---|
| 100 | 98.02 | One Fan point controlled by one one/way switch. | | 8 | Point |
|---|
| 101 | 98.03 | One 3 pin 5 Amps socket outlet on same board with other switch. | | 4 | Point |
|---|
| 102 | 98.04 | One 3 pin 5 Amps socket outlet on independent board | | 8 | Point |
|---|
| 103 | 98.05 | One bell point controlled by one way switch/ bell push | | 2 | Point |
|---|
| 104 | 99 | All as per item No. 98.00 above but using 2.5 Sqmm PVC insulated, unsheathed cable (FRLS) for one 3 pin socket outlet 15 Amps on independent board. | | 4 | Point |
|---|
| 105 | 100 | All as per item No. 98.00 above but using 4.0 Sqmm PVC insulated, unsheathed cable (FRLS) for one earth plug and socket on independent board. | | 2 | Point |
|---|
| 106 | 101 | S&F piano switch flush type 5 Amps single pole, one way, 230 volts AC circuit complete all as specified & directed. | | 54 | Each |
|---|
| 107 | 102 | S&F piano switch, bell push, 6 Amps, flush type, 230/250 Volts, 50 Hz supply. | | 2 | Each |
|---|
| 108 | 103 | S&F piano switch flush type 15 Amps single pole, one way 230 volts complete all as specified and directed. | | 4 | Each |
|---|
| 109 | 104 | S&F socket out let 2 in 1, 3 pin 5 Amps flush type, 230 volts complete all as specified and directed. | | 12 | Each |
|---|
| 110 | 105 | S&F socket out let 2 in 1 multipurpose three pin, 15 Amps & three pin 5 Amps, flush type 230 volts complete all as specified & directed. | | 4 | Each |
|---|
| 111 | 106 | S&F ceiling rose PVC polycarbonate isolated body 63.5x20 mm three terminal complete all as specified and directed. | | 44 | Each |
|---|
| 112 | 107 | Supply & fixing surface mounting type bulk head luminaries on wall with LED 10 watt lamp comprising of deep drawn anodized aluminium body epoxy sheet powder coated and connecting with suitable size copper conductor flexible cable from ceiling rose to connector of light fitting complete with accessories all as specified and directed. | | 8 | Each |
|---|
| 113 | 108 | Supply and fixing indoor decorative channel housing fitting slim LED batten 10 Watt (Mirror Light) 2 Feet with polycarbonate housing and diffuser AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable from ceiling rose to connector of the light fitting, fixing the same with two Nos PVC square box complete all as per specified and directed. | | 2 | Each |
|---|
| 114 | 109 | supply and fixing indoor decorative channel housing fitting slim LED batten 20 Watt with polycarbonate housing and diffuser AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable from ceiling rose to connector of the light fitting, fixing the same with two Nos PVC square box complete all as per specified and directed. | | 12 | Each |
|---|
| 115 | 110 | S&F Fan Regulator two module 5 step FSC Modular type 240 Volts complete all as specified and directed. | | 4 | Each |
|---|
| 116 | 111 | S & F sheet metal enclosure MCB DB 8 way, SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified and directecd.\nNote : Copper thimble shall be used for connection of cable . | | 2 | Each |
|---|
| 117 | 112 | Supply and fix MCB, single pole 240 volts 6 to 32 Amps capacity B series fixed in DB's complete all as specified and directed. | | 12 | Each |
|---|
| 118 | 113 | Supply and fix MCB, single pole and neutral link 240 volts 40 to 63 Amps capacity B series fixed in DB's complete all as specified and directed. | | 2 | Each |
|---|
| 119 | 114 | Supply and fixing sheet metal enclosure SP with two pin and earth plug and socket with one single pole MCB 20 Amps ,'B Curve 240 Volts complete all as specified and directed. | | 2 | Each |
|---|
| 120 | 115 | Earthing complete with galvanised steel pipe electrode, 40 mm bore, medium grade, 2.5 metres length, burried directly and preferably vertically in ground wtih top edge not less than 1.5 m deep below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No. 3 of SSR Part-I. Connected to earthing test point all as specified and including necessary earth pit PCC 1:3:6 chamber, 50mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 15mm dia upto 7.5m length from the earth plate electrode including necessary excavation & earth work in any strata complete all as specified and directed by Engr-in-Charge. | | 2 | Each |
|---|
| 121 | 116 | M&L galvanised tubing light grade 15 mm dia complete with all accessories buried under floor , or on wall all as directed for earth lead protection . | | 10 | RM |
|---|
| 122 | 117 | S&F door bell ding dong, multi tune, Chime and Buzzer complete all as specified and directed.\n | | 2 | Each |
|---|
| 123 | 118 | S&F Ceiling Fan 1400 mm sweep 230 Volts AC complete including clamp, down rod, canoopy and provisioning of flexible cord copper of size 23/0.0076 from ceiling rose to fan complete all as specified and directed.\n | | 4 | Each |
|---|
| 124 | 119 | Supply and fixing exhaust fan with louvers of size 250 mm sweep, 900 RPM 230 volts single phase AC supply complete with, bolt, nuts and washers, suitably embedded in the wall including making suitable opening and provisioning of flexible cord copper of size 23/0.0076 from ceiling rose to exhaust fan for giving connection complete all as specified and directed by Engineer-in-Charge, | | 4 | Each |
|---|
| 125 | 120 | Supply, installation, testing & commissioning of split type air conditioner units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality of capacity 1.5 TR 230 volt AC 50 c/s of BEE 5 star rating with minimum EER 3.5 as comprising of the following:- (a) 1.5 Ton capacity Eco friendly refrigerant cooling unit wall mounting type complete with remote control and draining out arrangement etc all as specified and directed. (b) One No condensing unit of 1.5 ton capacity comprising of all fitting such as single phase electric driven compressor, condensing fan motor, condensor with fixing of stand on wall and all necessary controls and accessories all as specified and directed. Note :- The rate quoted includes complete length of concealed copper tubbing required at site | | 2 | Each |
|---|