Repair/Replacement Of Lt Distribution Panel With Connected Unserviceable Items In Wac Line , Mh, Cod, Lalkurti Etc Under Ge (E) Agra, AGRA-Uttar Pradesh

Military Engineer Services-MES has published Repair/Replacement Of Lt Distribution Panel With Connected Unserviceable Items In Wac Line , Mh, Cod, Lalkurti Etc Under Ge (E) Agra. Submission Date for this Tender is 09-11-2020. Electrical Panel Tenders in AGRA Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

25793209
Repair/Replacement Of Lt Distribution Panel With Connected Unserviceable Items In Wac Line , Mh, Cod, Lalkurti Etc Under Ge (E) Agra
Open Tender
Indian
Uttar Pradesh
AGRA
09-11-2020

Tender Details

Repair / Replacement Of Lt Distribution Panel With Connected Unserviceable Items In Wac Line , Mh, Cod, Lalkurti Etc Under Ge ( E ) Agra - 2 Excavation In Trenches In Soft / Loose Soil N. Exc 1.5 Mtr Wide And Not Exc. 1.5 Meter Deep And Getting Out Including Forming Bottom Surface For Laying Of Cable Complete All As Specified And Directed. 3 All As Per Item No 1 Above But Depth Exceeding 1.5 Mtr Deep & Not Exc.3.0Mtr Complete All As Specified And Directed. 4 Returning Filling Including Spreading, Leveling, Watering And Well Ramming In Layers Not Exc 25 Cm Thick Complete All As Specified And Directed. 5 Removing Surplus Soil To A Distance N.Exc 50 Mtr And Depositing Where Directed At A Level N.Exc 1.5 Mtr Above The Starting Point Complete All As Specified And Directed. 6 Supplying And Laying Sand Cushioning For Cable Protection In Trenches / Filling In Ducts At Sub Stations Complete All As Specified And Directed. 7 Supplying And Laying Bricks Old Size Sub Class ‘B’ Laid Flat Across The Cable With Length Of Whole Brick For Protection Of Cable Complete All As Specified And Directed. 8 Laying Only Old Retrieved Bricks Old Size Sub Class ‘B’ Laid Flat Across The Cable With Length Of Whole Brick For Protection Of Cable Complete All As Specified And Directed. 9 M&L For Plain Cement Concrete Type D-2 1:4:8 ( Using 40Mm Stone Aggregate ) In Foundations, Filling And Mass Concrete For Pole & Stay Etc Complete All As Specified And Directed. 10 M&L For Plain Cement Concrete Type C-1 1:3:6 ( Using 20Mm Stone Aggregate ) In Coping Of Pole Etc Including Necessery Form Work Complete All As Specified And Directed. 11 Taking Out From Trenches Or Wall / Pole Or Pipe Cable Lt 1100 Volts Grade Heavy Duty , Armoured With Steel Strip Of Wire , With Stranded Aluminium Conductor Of Any Size Upto 25 Sqmm , Any Core , For Rectification Of Faults Or Replacement. Seggregating Serviceable Cable And Unserviceable Lenght By Meggering Or Any Other Suitable And Recommended Method. Removing Unserviceable From Site And Keeping Aside Serviceable For Reuse At Same Location Or Any Other Location Under Age E / M All As Rquired At Site Or Directed. N ( Earth Work Will Be Measured And Paid Separately Under Respective Item ) . 12 All As Per Srl Item 10 Here In Above But Of Size Of Cable 35 Sqmm To 95 Sqmm Complete All As Specified And Directed. 13 Laying Only In Trenches Or Fixed To Wall / Pole Or Passing Through Pipe Cable Lt 1100 Volts Grade Heavy Duty, Armoured With Aluminium Conductor Of Any Size Upto 25 Sqmm Any Core. ( Serviceable Cables Retrieved Against Srl Item 10.00 Above Will Be Used ) . 14 Laying Only In Trenches Or Fixed To Wall / Pole Or Passing Through Pipe Cable Lt 1100 Volts Grade Heavy Duty, Armoured With Aluminium Conductor Of Any Size 35 Sqmm To 95 Sqmm Any Core. ( Serviceable Cables Retrieved Against Srl Item 11 Above Will Be Used ) . 15 Supply And Laying In Trenches / Pipe / On Wall And Connecting And Testing Xlpe Insulated Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured Heavy Duty Electric Cable With Aluminium Conductor 1100V Grade Isi Marked Is 7098 ( Pt-I ) Of Size 16 Sq Mm 2 Core Complete All As Specified And Directed. Make Havells / Gloaster / Polycab / Grandlay 16 All As Per Item No 14 Above But 25 Sq Mm 3.5 Core Complete All As Specified And Directed. 17 All As Per Item No 14 Above Bu 35 Sq Mm 3.5 Core Complete All As Specified And Directed. 18 All As Per Item No 14 Above Bu 50 Sq Mm 3.5 Core Complete All As Specified And Directed. 19 All As Per Item No 14 Above Bu 70 Sq Mm 3.5 Core Complete All As Specified And Directed. 20 All As Per Item No 14 Above Bu 95 Sq Mm 3.5 Core Complete All As Specified And Directed. 21 All As Per Item No 14 Above Bu 120 Sq Mm 3.5 Core Complete All As Specified And Directed. 22 All As Per Item No 14 Above Bu 185 Sq Mm 3.5 Core Complete All As Specified And Directed. 23 All As Per Item No 14 Above Bu 240 Sq Mm 3.5 Core Complete All As Specified And Directed. 24 Supply And Fix Cable End Termination Jointing Kit Suitable For 1100 Volts Grade Lt Cable For Indoor / Outdoor Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3.5 Core Xlpe Armoured Aluminium Conductor Cable Of Size 25 To 50 Sqmm Complete All As Specified And Directed. Make : 3M / M-Seal / Denson / Reychem 25 All As Per Item No 23 Above But 70 Sq Mm To 150 Sqmm Complete All As Specified And Directed. 26 All As Per Item No 23 Above But 185 Sq Mm To 300 Sqmm Complete All As Specified And Directed. 27 M&L For Cable Jointing Kit Straight Through, Heat Shrinkable Type Suitable For Xlpe / Pvc Cables Of Size 25 Sqmm To 50 Sqmm 3½ Core Core With Working Voltage 1100 Volts Complete All As Specified And Directed. Make: Raychem / Denson / M Seal. 28 M&L For Cable Jointing Kit Straight Through, Heat Shrinkable Type Suitable For Xlpe / Pvc Cables Of Size 70 Sqmm To 150 Sqmm 3½ Core Core With Working Voltage 1100 Volts Complete All As Specified And Directed.Make: Raychem / Denson / M Seal. 29 M&L For Cable Jointing Kit Straight Through, Heat Shrinkable Type Suitable For Xlpe / Pvc Cables Of Size 185 Sqmm To 300 Sqmm 3½ Core Core With Working Voltage 1100 Volts Complete All As Specified And Directed.Make: Raychem / Denson / M Seal. 30 Material And Labour For Gi Tubing Light Grade 50Mm Bore With Fittings Laid For Protection Of Cable Under Road Crossing Fixed To Walls Or Pole Complete All As Specified And As Directed. ( Clamps For Fixing Pipe, Nuts, Bolts Washers Shall Be Measured Separately ) 31 Taking Down Carefully Aluminium Conductor Of Any Size From Lt Oh Lines After Unbinding From Insulators For Replacement Of Multijointed / Undersize Conductors Complete All As Specified And As Directed 32 Supplying, Fixing, Stringing Of Aluminum Conductor Steel Reinforced ( Acsr ) Including Binding Wire For Binding To Aluminum Conductor Properly On Insulators At Least 50Mm On Existing / New Pole Over Head Lines, Jumpring, Connection And Jointing And Testing Complete All As Specified And Directed. Make:Indial Alluminium Co / Bharat Conductor / Alind Nnote : ( I ) Cost Of Jumper Is Deemed To Be Included In The Rate 33 Restringing And Restretching Aluminium Conductor Reterived Under Item Srl 30 Above Including Necessary Binding With Insulators Using Alunimium Binding Wire, Connections Of Incoming And Out Going Cables Complete All As Specified And Directed. 34 Restringing Of Existing Oh Line, Of Acsr Of Any Size / Type On Existing Oh Line Restraching Properly And Fixing On Existing Insulators On Oh Cross Arms Of Poles Including Disconnection Service Connection Street Light Fitting Etc And Reconnecting The Same After Restraching Complete All As Specified And Directed N 35 M&L In Replacement For Gi Wire 4Mm Dia Drawn Straight Horizontal As Continuous Earth Wire On Poles Or Fabrication Of Cradles Complete All As Specified And Directed. 36 M&L For Aluminium Strip Of Any Size Cut To Length As Required At Site Including Drilling Holes, Bend To Shape For Repairing Of Lt Panels / Gods All As Required Or Directed By Engr-In-Charge. 37 M&L For Copper Strip Of Any Size Cut To Length As Required At Site Including Drilling Holes, Bend To Shape For Repairing Of Lt Panel / God Switches All As Required Or Directed By Engr-In-Charge. 38 M&L For Shackle Type Insulators Of 100Mm High, 115Mm Dia Porcelain, Vitreous, White, Brown Or Green Insulators For Working Pressure 1100 Volts Complete All As Specified, Required At Site Or Directed. 39 M&L For Pin Insulators 75 Mm Height And 90Mm Dia Size Porcelain, Vitreous, White, Brown Or Green Insulators For Working Pressure 1100 Volts Complete All As Specified, Required At Site Or Directed. 40 M&L For Stay Assembly Using Gi Stay Rod 20Mm Dia Complete With Stay Plate Mild Steel Of Size 300X300x6.00Mm Thick, Stay Bow Complete All As Specified And Shown In Electrical Plate No 1 . ( Necessary Earth Work, Stay Wire, Loop Insulator, Clamps And Pcc Shall Be Measured And Paid Seperately ) Complete All As Specified And Directed. 41 M&L For Galvanised Stay Wire Of Size 7 / 4Mm All As Specified And Directed. 42 M&L For Loop Type Insulator Large Size Porcelain Vitirious Of Size 90 X 140 Mm Clearence Of Hole 16Mm Complete All As Specified And Directed. 43 M&L For Steel Tubular Swaged Pole 9 Mtr Long With Cast Iron Base Plate, Finial Taper Plug, Bolts, Nuts And Screws As Specified Type 410 Sp 31, Including Painting With Anti Corrosive Paint Internally Complete And Externally Up To Planting Depth, Alternative Green & White Strips Of 30 Cm Width Upto 1.5 Mtr Above Ground Level, Balance Lenght To Be Painted With Two Coats Of Aluminium Paint Externally All As Required At Site Or Directed By Engr-In-Charge. 44 Supply And Fixing In Replacement Mccb Having Current Ratings 63 Amps With Rupturing Cap 16 Ka , Ac 415 Volts Three Pole With Microprocessor Release Complete With Spreader Links All As Specified And Directed Including Dismentling The Existing U / S Mccbs With All Connections & All As Required At Site Or Directed By Engr-In-Charge. Make Legrand / C&S / L&T / Siemens 45 Supply And Fixing In Replacement Mccb Having Current Ratings 100 Amps With Rupturing Cap 16 Ka , Ac 415 Volts Three Pole With Microprocessor Release Complete With Spreader Links All As Specified And Directed Including Dismentling The Existing U / S Mccbs With All Connections & All As Required At Site Or Directed By Engr-In-Charge. Make Legrand / C&S / L&T / Siemens 46 Supply And Fixing In Replacement Mccb Having Current Ratings 160 Amps With Rupturing Cap 25 Ka , Ac 415 Volts Three Pole With Microprocessor Release Complete With Spreader Links All As Specified And Directed Including Dismentling The Existing U / S Mccbs With All Connections & All As Required At Site Or Directed By Engr-In-Charge. Make Legrand / C&S / L&T / Siemens 47 Supply And Fixing In Replacement Mccb Having Current Ratings 250 Amps With Rupturing Cap 25 Ka , Ac 415 Volts Three Pole With Microprocessor Release Complete With Spreader Links All As Specified And Directed Including Dismentling The Existing U / S Mccbs With All Connections & All As Required At Site Or Directed By Engr-In-Charge. Make Legrand / C&S / L&T / Siemens 48 Supply And Fixing In Replacement Mccb Having Current Ratings 400 Amps With Rupturing Cap 36 Ka , Ac 415 Volts Three Pole With Microprocessor Release Complete With Spreader Links All As Specified And Directed Including Dismentling The Existing U / S Mccbs With All Connections & All As Required At Site Or Directed By Engr-In-Charge. Make Legrand / C&S / L&T / Siemens 49 Supply And Fixing In Replacement Mccb Having Current Ratings 630 Amps With Rupturing Cap 50 Ka , Ac 415 Volts Three Pole With Microprocessor Release Complete With Spreader Links All As Specified And Directed Including Dismentling The Existing U / S Mccbs With All Connections & All As Required At Site Or Directed By Engr-In-Charge. Make Legrand / C&S / L&T / Siemens 50 Removing All Connections From Lt Panel Having Feeders Upto 04 Nos ( Total Of Incoming And Outgoing ) , Any Capacity, Indoor Or Outdoor Type, Fpr Repairs / Servicing. Cleaning Properly All Parts And Removing Dust, Carbon Deposits Etc. Removing U / S Thimbles If Any Of Connections. Refixing Serviceable Items To The Panel And Making All Connections Including Testing For Proper Functioning Of The Panel As Per Standard Engineering Pactice. ( U / S Items Will Be Provided Against Respective Items Separately.. 51 Removing All Connections From Lt Panel Having Feeders Above 04 Nos Upto 08 Nos ( Total Of Incoming And Outgoing ) , Any Capacity, Indoor Or Outdoor Type, Fpr Repairs / Servicing. Cleaning Properly All Parts And Removing Dust, Carbon Deposits Etc. Removing U / S Thimbles If Any Of Connections. Refixing Serviceable Items To The Panel And Making All Connections Including Testing For Proper Functioning Of The Panel As Per Standard Engineering Pactice. ( U / S Items Will Be Provided Against Respective Items Separately. 52 Supply And Fix In Replacement Epoxy Based Post Insulators Lt 440V For Mounting Bus Bar All As Required Or Directed. 53 Supply, Installation , Commissiong And Testing Of Feeder Pillar Box, Kisok Outdoor Type, Cpri Approved Tested, Lt 440 Volts, 50 Hz , 3 Phase 4 Wire Supply , Floor Mounted Factory Fabricated Weather And Vermin Proof Protection Class Ip 54 Made Out Of 3 Mm Thick Ms Sheet Crca Sheet On Angle Iron 50X50x6mm Frame Of Size Suitable To Incorporate Following Accessories With Front And Rear Opening Doors, Handle Type Locking Arrangement Powder Coated Internally And Externally Shall Have Channel Base Of Appropriate Size And Mounted On Pcc Foundation Of Size As Required Or Approved By Manufacturers In Pcc 1:3:6 Type C-2 , Using 40 Mm Graded Crushed Stone Aggregate As Recommended By Manufacturer Or Directed By The Engr -In - Charge Including Earth Work Complete Comprising Of Following : Nincoming : ( A ) Bus Bar Chamber Comprising 4 Nos Copper Strip Bus Bars Pvc Insulated Made Of Copper Strip Of Size ( 50 X 6 ) Mm. Pvc Sheathed With Colour Coding. N ( B ) Mccb Having Current Ratings 400 Amps With Rupturing Cap 36 Ka , Ac 415 Volts Four Pole With Thermal Release Complete With Spreader Links. Make Legrand Or Equivalent Of Make / C&S / L&T / Siemens- 01 No Noutgoing : N ( A ) Mccb Having Current Ratings 250 Amps With Rupturing Cap 36 Ka , Ac 415 Volts Three Pole With Thermal Release Complete With Spreader Links. Make Legrand Or Equivalent Of Make / C&S / L&T / Siemens- 04 No N ( B ) Multifunctional Digital Panel Meter With Lcd Display Flush Mounting Type Of Size 96X96 Mm, Accuracy Class 1, Suitable For Cts With Secondary Current 5A, Make L&T Or Equivalent Of Make Schneider Or Ae:-01Nos Nall Accessories Pre-Wired With Suitable Size Pvc Insulated Copper Conductor Cables For Control Wiring And Pvc Insulated Copper Strips Of Appropriate Size For Power Circuits As Per Standard Engineering Practice And Required At Site And Suitable Foundation For Panel As Per Manufacturer Recommendation. 54 Supply, Installation , Commissiong And Testing Of Feeder Pillar Box, Kisok Outdoor Type, Cpri Approved Tested, Lt 440 Volts, 50 Hz , 3 Phase 4 Wire Supply , Floor Mounted Factory Fabricated Weather And Vermin Proof Protection Class Ip 54 Made Out Of 3.15 Mm Thick Ms Sheet Crca Sheet On Angle Iron 50X50x6mm Frame Of Size Suitable To Incorporate Following Accessories With Front And Rear Opening Doors, Handle Type Locking Arrangement Powder Coated Internally And Externally Shall Have Channel Base Of Appropriate Size And Mounted On Pcc Foundation Of Size As Required Or Approved By Manufacturers In Pcc 1:3:6 Type C-2 , Using 40 Mm Graded Crushed Stone Aggregate As Recommended By Manufacturer Or Directed By The Engr -In - Charge Including Earth Work Complete Comprising Of Following : Nincoming: ( A ) Bus Bar Chamber Comprising 4 Nos Copper Strip Bus Bars Pvc Insulated Made Of Copper Strip Of Size ( 50 X 5 ) Mm. Pvc Sheathed With Colour Coding. N ( B ) Mccb Having Current Ratings 630 Amps With Rupturing Cap 36 Ka , Ac 415 Volts Four Pole With Thermal Release Complete With Spreader Links. Make Legrand Or Equivalent Of Make L&T / C&S / Siemens- 01 No Noutgoing : ( A ) Mccb Having Current Ratings 400 Amps With Rupturing Cap 36 Ka , Ac 415 Volts Three Pole With Microprocessor Release Complete With Spreader Links. Make Legrand Or Equivalent Of Make / C&S / L&T / Siemens- 02 No N ( B ) Mccb Having Current Ratings 250 Amps With Rupturing Cap 36 Ka , Ac 415 Volts Three Pole With Microprocessor Release Complete With Spreader Links. Make Legrand Or Equivalent Of Make / C&S / L&T / Siemens- 02 No N ( B ) Mccb Having Current Ratings 250 Amps With Rupturing Cap 36 Ka , Ac 415 Volts Three Pole With Microprocessor Release Complete With Spreader Links. Make Legrand Or Equivalent Of Make / C&S / L&T / Siemens- 02 No Nall Accessories Pre-Wired With Suitable Size Pvc Insulated Copper Conductor Cables For Control Wiring And Pvc Insulated Copper Strips Of Appropriate Size For Power Circuits As Per Standard Engineering Practice And Required At Site And Suitable Foundation For Panel As Per Manufacturer Recommendation. 55 Disconnecting Electrically, Dismantling From Foundation Lt Panel Any Type And Removing From Site.

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail