| 1 | 1 | Providing Day to Day Running Maintenance and Operation of Sub-Station, DG Set, EI fittings and installations of stadium i/c compound/street lights i/c 42.5 mtr long high mast lights (Stadium lights) and semi high mast (i/c replacement of electrical accessories etc. on all days including Sundays & Holiday on monthly basis etc. as per the direction of Engineer-in-charge and whenever requried as per terms & condition attached.\n\n | 1 | 12 | Month |
|---|
| 2 | 2 | Providing services for operation & normal preventive maintenance on all days i/c Sunday & Holiday of RO Plant operator cum pump operator (water supply pump set i/c horticulure pump sets) i/c cleaning of pump sets panels /RO plant panels and water cooler, changing of gland dori with parts repair of pump sets with parts & pump control panel keeping the pump set in running position complete etc as reqd installed at Various location of Chattrasal Stadium. | 2 | 12 | Month |
|---|
| 3 | 3 | Pdg. Services of day to day operation i/c maintenance of complete fire alarm detection system, digital/mechanical evacuation system i/c fire fighting & sprinkler system etc. complete with associated control panel, motors, pumps, valves & fire fighting pumps on all days round the clock basis i/c supplying and replacement of all defective spare parts in fire panel i.e. switch, resistance, diode, mother board, card, glass covers etc. for maintaining and upkeep the complete system in healthy and functional condition i/c operation of water supply pumps/storm water pumps and submersible pump set etc. installed in the stadium campus by providing workmen and as per terms and conditions attached i/c cleaning of all equipments/machineries, pump house & all associated pipe lines, control switch gears, cleaning of fountain pond etc. in maintaining the system always good & healthy condition for work. \n | 3 | 12 | Month |
|---|
| 4 | 4 | Operation and Maintenance of fountain installed at Chhatarsal Stadium as and when reqd i/c Sundays & Holidays i/c preventive maintenance & cleaning of all control panels and other accessories i/c under water light fittings i/c cleaning of fountain ponds and all accessories with the help of necessary cleaning agents/materials as per terms & conditions attached). \n(a)Water fountain near statue complete with 2 nos 7.5 HP fountain pumps\nb) Water fountain 30 mtrs long with 5 nos 7.5 HP fountain pumps | 4 | 12 | Month |
|---|
| 5 | 5 | Pdg. Services of operation and upkeep of passenger lifts installed at Chattarsal Stadium, Delhi on all working days i/c Sundays & Holidays i/c watch & Ward and security of lift equipments and accessories i/c lodging the complaint of faults/defects with OEM of lift (for rectifcation of defects and healthiness & functionality of lifts) providing following workmen as per detail given below:- Lift Operator 2 Nos. (One for each lift) (8AM to 6PM) or when as reqd. as per requirement | 5 | 12 | Month |
|---|
| 6 | 6 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.\nGroup C | 6 | 100 | pt. |
|---|
| 7 | 7 | Supplying Installation Testing and Commissioning of following electrical accessories for day maintenance in the existing electrical installation /wiring -rewiring etc as reqd ( Labour already include in item No.1)\n1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable | 7 | 1000 | Mtr. |
|---|
| 8 | 7.01 | 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable | 8 | 500 | Mtr. |
|---|
| 9 | 7.02 | 6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable | 9 | 300 | Mtr. |
|---|
| 10 | 7.03 | 16/0.20 mm (0.5 sq.mm) twin core FRLS PVC sheathed, flat flexible copper cable | 10 | 500 | Mtr. |
|---|
| 11 | 7.04 | S.P. 5/6 A, one way modular switch, ISI marked | 11 | 100 | Each |
|---|
| 12 | 7.05 | S.P. 15/16 A, one way modular switch, ISI marked | 12 | 100 | Each |
|---|
| 13 | 7.06 | 3 pin 5/6 A modular socket outlet, ISI marked | 13 | 100 | Each |
|---|
| 14 | 7.07 | 6 pin 15/16 A modular socket outlet, ISI marked | 14 | 100 | Each |
|---|
| 15 | 7.08 | 3 pole MCCB, 100A, 16kA | 15 | 4 | Each |
|---|
| 16 | 7.09 | 3 pole MCCB, 150A, 16kA | 16 | 2 | Each |
|---|
| 17 | 7.1 | 3 pole MCCB, 200A, 25kA | 17 | 2 | Each |
|---|
| 18 | 7.11 | 63 A, 2 Pole isolator | 18 | 20 | Each |
|---|
| 19 | 7.12 | 40 A, 4 Pole isolator | 19 | 10 | Each |
|---|
| 20 | 7.13 | 63 A, 4 Pole isolator | 20 | 10 | Each |
|---|
| 21 | 7.14 | Capacitor 2.5 Microfarad | 21 | 100 | Each |
|---|
| 22 | 7.15 | Capacitor 3.15 Microfarad | 22 | 40 | Each |
|---|
| 23 | 7.16 | Ignitor for 70-400 W suitable for HPSV /MH Lamp | 23 | 20 | Each |
|---|
| 24 | 7.17 | 250 watt SE lamp | 24 | 10 | Each |
|---|
| 25 | 7.18 | 400 watt SE lamp | 25 | 10 | Each |
|---|
| 26 | 7.19 | 250 watt MH/SV Ballast | 26 | 10 | Each |
|---|
| 27 | 7.2 | 400 watt MH/SV Ballast | 27 | 10 | Each |
|---|
| 28 | 7.21 | 1 x 36 watt electronic choke | 28 | 100 | Each |
|---|
| 29 | 7.22 | 2 x 36 watt electronic choke | 29 | 100 | Each |
|---|
| 30 | 7.23 | 1 x 28 watt electronic choke | 30 | 100 | Each |
|---|
| 31 | 7.24 | 2 x 28 watt electronic choke | 31 | 100 | Each |
|---|
| 32 | 8 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.\n63 mm dia (OD-63 mm & ID-51 mm nominal) | 32 | 180 | Mtr. |
|---|
| 33 | 8.01 | 90 mm dia (OD-90 mm & ID-76 mm nominal) | 33 | 80 | Mtr. |
|---|
| 34 | 9 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.\n63 mm dia (OD-63 mm & ID-51 mm nominal) | 34 | 180 | Mtr. |
|---|
| 35 | 9.01 | 90 mm dia (OD-90 mm & ID-76 mm nominal) | 35 | 80 | Mtr. |
|---|
| 36 | 10 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. \nUpto 35 sq. mm | 36 | 160 | Mtr. |
|---|
| 37 | 10.01 | Above 35 sq. mm and upto 95 sq. mm | 37 | 100 | Mtr. |
|---|
| 38 | 10.02 | Above 95 sq. mm and upto 185 sq. mm | 38 | 160 | Mtr. |
|---|
| 39 | 11 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. \nUpto 35 sq. mm | 39 | 200 | Mtr. |
|---|
| 40 | 11.01 | Above 35 sq. mm and upto 95 sq. mm | 40 | 200 | Mtr. |
|---|
| 41 | 11.02 | Above 95 sq. mm and upto 185 sq. mm | 41 | 200 | Mtr. |
|---|
| 42 | 12 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. \nUpto 35 sq. mm (clamped with 1mm thick saddle) | 42 | 200 | Mtr. |
|---|
| 43 | 12.01 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) | 43 | 200 | Mtrs. |
|---|
| 44 | 12.02 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/ 40x3mm MS flat clamp) | 44 | 200 | Mtr. |
|---|
| 45 | 13 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.\n3 x 1.5 sq. mm | 45 | 100 | Mtr. |
|---|
| 46 | 13.01 | 6 x 1.5 sq. mm | 46 | 100 | Mtr. |
|---|
| 47 | 13.02 | 3 x 4 sq. mm | 47 | 200 | Mtr. |
|---|
| 48 | 13.03 | 6 x 4 sq. mm | 48 | 80 | Mtr. |
|---|
| 49 | 13.04 | 3 x 6 sq. mm | 49 | 80 | Mtr. |
|---|
| 50 | 13.05 | 6 x 6 sq. mm | 50 | 50 | Mtr. |
|---|
| 51 | 14 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.\n20 mm | 51 | 100 | Mtr. |
|---|
| 52 | 14.01 | 25 mm | 52 | 100 | Mtr. |
|---|
| 53 | 14.02 | 32 mm | 53 | 50 | Mtr. |
|---|
| 54 | 15 | Supplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s, with provision of 100 amps TP 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB’s/ MCCB) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)\n4 Way TP | 54 | 3 | Each |
|---|
| 55 | 16 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. | 55 | 5 | Each |
|---|
| 56 | 17 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. | 56 | 40 | Mtr. |
|---|
| 57 | 18 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. | 57 | 80 | Mtr. |
|---|
| 58 | 19 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.\n2 X 16 sq. mm | 58 | 4 | Each |
|---|
| 59 | 19.01 | 3½ X 25 sq. mm | 59 | 4 | Each |
|---|
| 60 | 19.02 | 3½ X 35 sq. mm | 60 | 4 | Each |
|---|
| 61 | 19.03 | 3½ X 50 sq. mm | 61 | 3 | Each |
|---|
| 62 | 19.04 | 3½ X 70 sq. mm | 62 | 3 | Each |
|---|
| 63 | 19.05 | 3½ X 95 sq. mm | 63 | 3 | Each |
|---|
| 64 | 19.06 | 3½ X 120 sq. mm | 64 | 3 | Each |
|---|
| 65 | 20 | Supplying and Installation of heavy duty exhaust fan alongwith aluminium louvers of 300 mm sweep 900 rpm in the existing opening, including making the hole suitable the size of the above fan making good the damage, connection testing commissioning etc as reqd. | 65 | 10 | Each |
|---|
| 66 | 21 | Servicing and overhauling of HT 400/630/800 Amp VCB/OCB complete etc. as required i/c routine yearly check up and reports etc. as well as testing & calibration of micro processor controlled relay of HT panel routine test etc. as reqd. with the help of relay testing machine etc. as required (a) O/C relay-2 nos. (b) Earth fault relay-1 no. (c) Master relay-1 no. (d) Trip circuit supervision relay-1 no | 66 | 2 | Job |
|---|
| 67 | 22 | Servicing of draw out type 800 amp/1000 amp/1600 amp/2000 amp, ACB 3 Phase 415 volt 50 Hz from the MV Panel, complete cleaning lubricating of moving parts checking and testing of wiring system, replacment of minor space parts such as spring, nuts bolts and washer, setting right the mechanism and reassembling testing and commissioning etc as required. (The work involves replacement of worn-out part with material within quoted rate) | 67 | 6 | Job |
|---|
| 68 | 23 | Calibration of Over Current and earth fault numeric type relay cleaning checking of wiring system calibration with secondary injection test kit setting of tripping according to the load complete with testing and commissioning as require. | 68 | 6 | Job |
|---|
| 69 | 24 | Lifting of existing defective pump set from the sump and lowering the repaired pump of 3/5 HP Submersible / Borewell Submersible Pump, 3 Phase including rewinding of motor including dismantling , assembling, commissioning and testing the same on load after making electric connections at site i/c site visit by Engineer and to and fro cartage etc. complete as required. | 69 | 2 | Each |
|---|
| 70 | 25 | Providing & fixing following Gun metal gate valve in the existing line with accessories etc. as reqd.\n50 mm. | 70 | 3 | Each |
|---|
| 71 | 25.01 | 80 mm. | 71 | 3 | Each |
|---|
| 72 | 26 | Providing & fixing of following size G.M Non-return valve in the existing line with accessories complete etc. as reqd. \n50 mm | 72 | 3 | Each |
|---|
| 73 | 26.01 | 80 mm. | 73 | 3 | Each |
|---|
| 74 | 27 | Supplying and fixing 6 mm size steel wire rope nylon insulated i/c D locking arrangement at the end for holding submersible pump set complete etc as reqd. | 74 | 50 | Meter |
|---|
| 75 | 28 | Repairing of mono block pump set of 25HP/18.6 KW including rewinding kit of motor, replacement of mechanical seal TC/TC upper, mechanical seal TC/TC lower, ball bearing, 'O' Ring, stamping repairing, lowering and lifting of the pump-set from the sump with the help of including dismantling , assembling, commissioning and testing the same on load after making electric connections at site i/c to and for cartage etc. complete as required. | 75 | 1 | Job |
|---|
| 76 | 29 | Comprehensive maintenance of following LPH R.O. Plants i/c supplying and replacement of all defective parts, micron filter catridges, anti-scalent, membranes and pump-sets etc. complete as required .\n(A) 50 LPH Capacity\ni) Chhattrasal Stadium - 2 Nos.\n(B) 250 LPH Capacity\n(i) Chhattrasal Stadium - 2 Nos. | 76 | 12 | Month |
|---|
| 77 | 30 | S/I/T/C/ of Reverse Osmisis RO+UV+UF system designed to deliver min 50 liters of purified water per hour through a 6 stage purification process. Its membrane should have a pore size of 0.0001 micron size which prevents the passage the of micro organisms and total dissoved salts making the water lighter, taste natural and safe to drink with automated switching off device.\nTechnical Specification:-\nreservoir capacity - (Not provided)\nProduction capacity - (50)\nRO Member (Thin Film Composite)- (75 GPD*4 Nos)\nUF Membrane 0.1 - 0.01 Micron\nInput Power Rating (Single Phase 100 - 250 V AC, 50-60 Hz)\nSystem Operating Voltage ( 24 V DC)\nOperating Temprature (10 Degree C to 40)\nMin. /Max. Operating pH- 6.5-8.0\n% of rejection of TDS (90 % (Approx) \nRO Membrane Flushing - (Auto Flush @ Every Start, every stop and every one hour of working for 1 minute.)\nStage of filtration - (Particulate Filter Memberane Life Enhancer Filter Sediment Filter Pre-carbon Filter R.O. Membrane Filter Post Carbon Filter)\n(Make- Kent Elite Plus-199716/ or equivalent in approved make) | 77 | 1 | Each |
|---|
| 78 | 32 | Comprehensive Maintenance of 1 x 750 KVA DG Set complete with alternator AMF panel & battery charges including carrying out the periodic maintenance with 02 Nos. B-Check Kit, Oil, Coolant, 01 Sets of Air Filter including cartage charges except cost of the spares complete as required. (All the B-Check material shall be supplied by the agency). (Cummins Model: QSK23-G31, ESN-00319090) | 78 | 12 | Month |
|---|
| 79 | 33 | Supplying of following accessories for 1 x 750 KVA DG Set for 'B' Check etc. complete as required. (Labour charges of this item is included in item No. 32)\nSeparator Fuel Water (4095189) | 79 | 4 | Each |
|---|
| 80 | 33.01 | Element Lub Oil Filter (388931) | 80 | 4 | Each |
|---|
| 81 | 33.02 | Water Filter DCA4-23 (405896) | 81 | 4 | Each |
|---|
| 82 | 33.03 | Inhibitor Corrission (4926654) | 82 | 4 | Each |
|---|
| 83 | 33.04 | Element Outer (4957708) | 83 | 2 | Each |
|---|
| 84 | 33.05 | Element Inner (4957709) | 84 | 2 | Each |
|---|
| 85 | 34 | Comprehensive Maintenance of 1 x 750KVA DG Set complete with alternator AMF panel & battery charges including carrying out the periodic maintenance with 01 Nos. B-Check Kit, Oil, Coolant, 1 Sets of Air Filter including cartage charges except cost of the spares complete as required. (All the B-Check material shall be supplied by the agency). (Cummins Model: KTA-38G2, ESN-25347507) | 85 | 12 | Month |
|---|
| 86 | 35 | Supplying of following accessories for 1 x 750 KVA DG Set for 'B' Check etc. complete as required. (Labour charges of this item is included in item No. 34)\nElement Lub Oil Filter (3165) | 86 | 8 | Each |
|---|
| 87 | 35.01 | Seal Rectangular Ring | 87 | 8 | Each |
|---|
| 88 | 35.02 | Element Fuel Filter (4084133) | 88 | 4 | Each |
|---|
| 89 | 35.03 | GASKET, Fuel Filter Cover | 89 | 4 | Each |
|---|
| 90 | 35.04 | Element, Oil by Pass filter | 90 | 4 | Each |
|---|
| 91 | 35.05 | Seal O Ring | 91 | 4 | Each |
|---|
| 92 | 35.06 | Seal O Ring | 92 | 4 | Each |
|---|
| 93 | 35.07 | Element Air Cleaner (4020551) | 93 | 2 | Each |
|---|
| 94 | 35.08 | Element Air Cleaner (4020552) | 94 | 2 | Each |
|---|
| 95 | 35.09 | Inhibitor Corrission (3167218) | 95 | 2 | Each |
|---|
| 96 | 35.1 | Element CRN Resistor (3827423) | 96 | 8 | Each |
|---|
| 97 | 36 | Supplying & pouring of following quality engine oil in the existing DG Set as & when reqd.as premium blue 15W/40 | 97 | 630 | P/ltr |
|---|
| 98 | 37 | Comprehensive, running maintenance & Servicing of following capacity Window / Split installed under Chhattarsal Stadium i/c replacement all defective i.e. blower motor, compressor, Gas Charging, PCB, remote, Plug Top, Starting Capacitor, Running Capacitor, Starting Relay, Thermostat, Propeller Fan, Over load Relay i/c condenser unit, evaporative unit charging of refrigerant gas in case of leakage i/c refrigerant gas pipe with insulation, lead wire, plug Top, etc complete as per terms and conditions attached:-\na) Window type AC/ Split type AC of 1.5TR/2.0 TR capacity.\n(95 Nos. AC for 12 Months = 1140 Jobs) | 98 | 1140 | Job |
|---|
| 99 | 38 | SITC of energy efficient 3 star rated wall mounted split type AC Unit 2 TR capacity inverter type nominal capacity suitable for operation on single phase, 220v, 50hz, AC supply i/c electronic remote control, comprising of both indoor and outdoor unit with rotary compressor duly filled with suitable ecofriendly refrigerant, MS Angle iron stand for outdoor, 6 meter length. 4core 2.5 Sq mm wire, 4 mtr. copper tube of suitable size, wall thickness 0.8mm duly insulated with 9mm nitrile insulation, 5 mtr. PVC drain pipe of size 25mm i/c Elbow, Tee, Socket, Cement Solvent etc. complete as reqd. | 99 | 2 | Each |
|---|
| 100 | 39 | Supplying and fixing copper refrigerant pipe alongwith the accessories duly insulated with 9mm nitrile insulation for AC etc as reqd. | 100 | 10 | Mtr. |
|---|
| 101 | 40 | Providing and fixing of 12 Volt, 75 AH sealed maintenance free batteries for 40 KVA online UPS installed in Chattarsal Stadium i/c connection testing & commisioing etc as reqd. (i/c providing of connecting lead for batteries if reqd.) i/c credit to old existing | 101 | 70 | Each |
|---|
| 102 | 41 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required\na) 150 mm dia. \n | 102 | 20 | Mtrs |
|---|
| 103 | 41.01 | b) 80 mm dia. | 103 | 20 | Mtrs |
|---|
| 104 | 42 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. | 104 | 2 | Each |
|---|
| 105 | 43 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required.\nStainless Steel (Grade 304) | 105 | 10 | Each |
|---|
| 106 | 44 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :\n150 mm dia. | 106 | 2 | Each |
|---|
| 107 | 45 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :\n150 mm dia. | 107 | 2 | Each |
|---|
| 108 | 46 | Supplying and fixing single headed internal/external hydrant valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Stainless Steel cap and chain as required\nSingle headed Stainless steel | 108 | 2 | each |
|---|
| 109 | 47 | Providing & Fixing 20 mm nominal internal dia gun metal globe valve & nozzle for first aid horse real. | 109 | 20 | Each |
|---|
| 110 | 48 | S/I/T/C i/c Replacement of following wornout/defective accessories/spares i/c connections, testing etc. as reqd.\na) Sprinkler (UL listed) | 110 | 3 | Each |
|---|
| 111 | 48.01 | b) Pressure gauge150 mm dia | 111 | 2 | Each |
|---|
| 112 | 49 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. | 112 | 4 | Each |
|---|
| 113 | 50 | Refilling of following type (stored pressure) fire extinguisher of different capacity ISI marked ABC dry powder/Co2/Foam i/c hydraulic pressure testing painting etc as reqd.\nABC Type (5Kg) | 113 | 30 | Each |
|---|
| 114 | 50.01 | CO2 (4.5 Kg) | 114 | 20 | Each |
|---|
| 115 | 50.02 | Foam Type (50ltr) | 115 | 5 | Each |
|---|
| 116 | 51 | S/I/T/C of ABC Powder type (Stored Pressure) Fire Extinguisher 6 KG. Capacity ISI Mark IS: 15683 Operating temperature (+5)°C to (+55)°C for Class 3A type of fire filled with MAP Powder complete in all respect etc. as reqd.\n | 116 | 15 | Each |
|---|
| 117 | 52 | S/I/T/C of CO2 type fire extinguisher 4.5 Kg Capacity ISI Mark IS: 15683 operatng temperature (-30) °C to (55) °C for Class 13B type of fire fitted with 1 Mt. Hose & PVC Horn complete in all respect etc. as reqd. | 117 | 10 | Each |
|---|
| 118 | 53 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade one or more coats on old work) i.e. Painting of various metallic surface i/c scraping old paint from HT Panel, LT Panel, Transformer, Feeder Pillar, DB's, Loose Wire Box etc as reqd. | 118 | 100 | Sqmt. |
|---|
| 119 | 54 | Supplying and Fixing of hose cabinet of size 900 mm x 600 mm x 500 mm made of 1.6 mm thick MS sheet with 6 mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant 2 Nos. 15 mtr. Long Hose pipe, 1 No branch pipe, mounted on wall OR raised brick platform & duly painted with Post Office red externally and white internally with synthetic enamel paint complete in all respect, for external hydrant, as required. | 119 | 5 | each |
|---|
| 120 | 55 | Supplying and Fixing water proof LED lights made out of Stainless Steel suitable to be fitted with LED'S(Warm white) capacity 3x1 watt 24 volts including testing & commissioning complete as reqd. | 120 | 10 | each |
|---|
| 121 | 56 | Supply and fixing of Waterproof LED Lights (RGB Colour ) 3x3watt Forged stainless Steel construction with Stainless Steel top surface(Wall/floor recessed) including testing & commissioning etc. as required. | 121 | 15 | each |
|---|
| 122 | 57 | S/I/T/C of gun metal Geyser Jet compatible with the existing Geyser jet of size 25 mm with universal with GI fittings etc. as required. | 122 | 5 | each |
|---|
| 123 | 58 | S/F of following size PVC insulated PVC sheathed copper conductor submersible flat cables in existing pipe/on surface/recess along with GI pipes etc complete as reqd.\n3 x 1.5 sq mm size | 123 | 60 | mtr |
|---|
| 124 | 59 | Servicing and Overhauling of 7.5 HP induction 3 Phase Motor Pump set i/c varnishing ,greasing , oiling and making Coupling alignment i/c replacement of bearing, coupling etc and re- nstallation the same, testing and commissioning etc complete as reqd. | 124 | 1 | Job |
|---|
| 125 | 60 | Servicing and Overhauling of upto 7.5 HP induction 3 Phase Motor of jockey Pump set i/c varnishing ,greasing , oiling and making Coupling alignment i/c replacement of bearing, coupling etc and re-installation the same, testing and commissioning etc complete as reqd. | 125 | 1 | Job |
|---|
| 126 | 61 | Repairing of Mono submersible motor upto 7.5 HP complete dismentaling and carrying out the following works i/c cartage pf pump to and from site to workshop including testing & commissioning etc as required.\nRewinding of motor - 01 No.\nMotor bush bearing - 1 No.\nRotor sleeve polishing grinding - 1 No.\nMotor seal - 04 Nos.\nMotor Studs - 01 No. | 126 | 2 | Job |
|---|
| 127 | 62 | Supplying, laying/ fixing, testing and commissioning of following thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/ sq.m polythene sheet (vapour barrier) on existing pipe and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints etc. as per specifications and as required.\n75 mm | 127 | 60 | Sqmt. |
|---|
| 128 | 63 | Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. | 128 | 40 | Sqmt. |
|---|
| 129 | 64 | Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. | 129 | 5 | Sqmt. |
|---|
| 130 | 65 | Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. | 130 | 5 | Sqmt. |
|---|