Civil And Electrical Works For Flood Re-Construction Works At Sub Centre Melangadi , Malappuram, Sub Centre Melangadi-Kerala

Hll Lifecare Limited-HLL has published Civil And Electrical Works For Flood Re-Construction Works At Sub Centre Melangadi , Malappuram. Submission Date for this Tender is 28-10-2020. Electrical Maintenance Tenders in Sub Centre Melangadi Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

25785475
Corrigendum : Civil And Electrical Works For Flood Re-Construction Works At Sub Centre Melangadi , Malappuram
Open Tender
Indian
Kerala
Sub Centre Melangadi
28-10-2020

Tender Details

Civil And Electrical Works For Flood Re-Construction Works At Sub Centre Melangadi , Malappuram

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Oct-2020 Financial Bid Corrigendum Financial Bid 28-10-2020

Key Value

Document Fees
INR 2800 /-
EMD
INR 50000.0 /-
Tender Value
INR 37.32 Lakhs /-

BOQ Items

Name of Work: SETTING UP FLOODRESTORATION WORK AT MELANGADI SUB CENTRE -MALAPPURAM DIST.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Civil Work
2 1.01 Earth Work
3 1.02 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation\ntrenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and\nramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 42.48 Cum
4 1.03 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 375.14 Cum
5 1.04 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 80 Sqm
6 2 Dismantling and Demolishing
7 2.01 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 13.861 Cum
8 2.02 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 54.257 Cum
9 2.03 Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar 21.85 Cum
10 3 CEMENT CONCRETE
11 3.01 Providing and laying in position cement concrete of specified grade excluding the cost of centering and\nshuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 21.901 Cum
12 4 MASONRY WORKS
13 4.01 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:4 ( 1 cement : 4 coarse sand) 46.126 Cum
14 4.02 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in\nsuperstructure above plinth level up to floor V level.Cement mortar 1:3 (1 cement : 3 coarse sand) 118.85 Cum
15 4.03 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 35.341 Cum
16 4.04 Constructing brick masonry circular type manhole 0.91 m internal dia at bottam and 0.56 m dia at to[ in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size ), and making necessary channel in cement concrete 1:2:4 ( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design:With Sewer bricks conforming to IS:4885 1 Each
17 4.05 Extra depth circular type manhole 0.91 m internal dia ( at bottom) beyound 0.91 m to 1.67 mWith Sewer bricks conforming IS: 4885 1.5 M
18 5 R.C.C. Work
19 5.01 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of\ncentering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size 21.634 Cum
20 5.02 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 26.304 Cum
21 6 Form Work
22 6.01 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 189.36 Sqm
23 6.02 Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) 173.868 Sqm
24 6.03 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 5828.26 Kg
25 7 PLASTERING
26 7.01 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 711.983 Sqm
27 8 ALUMINIUM WORKS
28 8.01 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing,\npaneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 130.806 Kg
29 8.02 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 138.217 Kg
30 8.03 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 8.4 Sqm
31 8.04 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 21.191 Sqm
32 8.05 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with S.S. screws etc. complete as per direction of Engineer -in-Charge.Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar 16 Each
33 8.06 Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making goods etc.. Complete 9 Each
34 8.07 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc.\ncomplete. 7 Each
35 8.08 Providing and fixing PTMT Butt hinges with necessary screws etc. complete.100x75x10 mm fitted with 5.5 mm dia MS Bright Bar Rod weighing not less than 53 gms 16 Each
36 8.09 Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc.,\ncomplete.202x42x18 mm weighing not less than 78 gms 14 Each
37 9 Steel Work
38 9.01 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 428.4 Kg
39 9.02 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.,\nincluding welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the\nsame with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary\naccessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 16.12 Kg
40 10 Wall Tile
41 10.1 Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be\nspecified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 29.401 Sqm
42 11 Floor Tile
43 11.01 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be\nspecified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete. 5.57 Sqm
44 11.02 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 93 Sqm
45 11.03 Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand):Dark shade pigment using ordinary cement 3.345 Sqm
46 11.04 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm\n1 2.87 Sqm
47 12 Pavor Block
48 12.01 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 70 Sqm
49 13 Wooden Panels
50 13.01 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood 0.946 Cum
51 13.02 Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and\nclerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shutters 6.301 Sqm
52 13.03 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside\ngrooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood 2.52 Sqm
53 14 Painting
54 14.01 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 527.182 Sqm
55 14.02 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 103.68 Sqm
56 14.03 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per\nmanufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 527.182 Sqm
57 14.04 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per\nmanufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of\napproved brand and manufacture 8.821 Sqm
58 14.05 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per\nmanufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 17.45 Sqm
59 15 FRP Door
60 15.01 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 15 M
61 15.02 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and olyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge. 5.041 Sqm
62 16 Water Supply & Sanitary Works
63 16.01 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold\nwater supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mmnominal outer dia pipes 45 M
64 16.02 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold\nwater supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 45 M
65 16.03 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold\nwater supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes 45 M
66 16.04 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow operated levers 6 Each
67 16.05 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and\nstainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm 1 Each
68 16.06 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm\nnominal bore 1 Each
69 16.07 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and\ncolour.Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms 14 Each
70 16.08 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 3 Each
71 16.09 Providing and fixing brass bib cock of approved quality :20 mm nominal bore 3 Each
72 16.1 Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid150 mm nominal size square 100 mm diameter of the inner hinged round grating 3 Each
73 16.11 Providing and fixing rectangular high density polyethylene water storageloft tank with cover, conforming to ISI : 12701, colour of opaque white or asapproved by Engineer-in-charge. The rate includes making necessary holesfor inlet, outlet & over flow pipes. The base support i/c fittings & fixtures fortank shall be paid separately. 2000 Ltr
74 16.12 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge 3 No
75 16.13 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This\nincludes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2 30 M
76 16.14 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 30 M
77 17 Electrical Work
78 18 POINT WIRING
79 18.01 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point 17 Point
80 18.02 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point 7 Point
81 19 PLUG POINTING
82 19.01 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box\nincluding connections but excluding modular plate etc. as required.5/6 amps switch 15 Each
83 19.02 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box\nincluding connections but excluding modular plate etc. as required.15/16 amp switch 10 Each
84 19.03 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box\nincluding connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 15 Each
85 19.04 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box\nincluding connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 10 Each
86 19.05 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 8 Each
87 19.06 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modula switches in recess etc as required.6 Module 200mmX75mm) 6 Each
88 19.07 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) 4 Each
89 20 SUB/CIRCUIT MAINS
90 20.01 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated\ncopper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire 265 M
91 20.02 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated\ncopper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 120 M
92 20.03 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated\ncopper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 25 M
93 20.04 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 220 M
94 21 POWER CIRCUITRY
95 21.01 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,\non surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,\ninterconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door 1 Each
96 21.02 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker\nsuitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 12 Each
97 21.03 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete\nwith connections, testing and commissioning etc. as required.40 amps 1 Each
98 21.04 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 1 Each
99 22 EARTHING
100 22.01 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry\nenclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required 1 Set
101 22.02 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing asrequired. 25 M
102 23 FITTINGS
103 23.01 20W LED TUBE TYPE FIXTURE<br>SITC OF Modular type 20W LED tube type fixture directly on to wall including drilling and fixing, making necessary connections and make as approved by engineer in Charge or Electrical Engineer 14 Each
104 23.02 CFL LAMP<br>Supply and installation of 18 W CFL with its all accessories.[ISI MAKE] 5 Each
105 23.03 Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extendedoriginal wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C 7 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail