Annual Repair Maintenance Of Electrical And Mechanical Installations Of Cisf Barracks , Outer Marker And Solar Obstruction Lights On Hills At International Airport , Jaipur 2020-21

Tender Notice

25783354
Annual Repair Maintenance Of Electrical And Mechanical Installations Of Cisf Barracks , Outer Marker And Solar Obstruction Lights On Hills At International Airport , Jaipur 2020-21
Indian
Rajasthan
20-10-2020
29-10-2020
02-11-2020

Tender Details

annual repair maintenance Of Electrical And Mechanical Installations Of Cisf Barracks , Outer Marker And Solar Obstruction Lights On Hills At International Airport , Jaipur 2020-21

Key Value

Document Fees
INR 1180 /-
EMD
INR 98307.00 /-
Tender Value
Refer document

BOQ Items

Name of Work: ARMO of E&M Installations of CISF Barracks, Outer Marker and Solar Obstruction Lights on Hills at International Airport, Jaipur (2020-21).
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Providing one number skilled manpower in one shift of 8 hour on all days including sundays and holidays (excluding weekly off day) for one month for operation & maintenance of electrical & mechanical installations. item1 72 Job
2 2 Providing one number semi-skilled manpower in one shift of 8 hour on all days including sundays and holidays (excluding weekly off day) for one month for operation & maintenance of electrical & mechanical installations. item2 48 Job
3 3 Providing one number un-skilled manpower in one shift of 8 hour on all days including sundays and holidays (excluding weekly off day) for one month for operation & maintenance of electrical & mechanical installations. item3 96 Job
4 4 Comprehensive maintenance of 02 nos. solar powered obstruction light comprising of battery bank, charger, light assembly, solar panel, controls cards, PV panels, flashers unit, ammeter, voltmeter etc. installed at Jagatpura & Jhalana Hills including replacement/ repairs of all consumables, spares, materials etc. complete as required. item4 12 Month
5 5 Repairing and rewinding of fan motor of desert cooler/room cooler with super enamelled copper wire of required grade insulation including dismantling, re-installation, testing etc. as required. item5 30 Each
6 6 Repairing and rewinding of fan motor of 300 mm dia exhaust fan with super enamelled copper wire of required grade insulation including dismantling, re-installation, testing etc. as required. item6 15 Each
7 7 Repairing and rewinding of fan motor of 450 mm dia exhaust fan with super enamelled copper wire of required grade insulation including dismantling, re-installation, testing etc. as required. item7 15 Each
8 8 Repairing and rewinding of fan motor of ceiling fan/wall fan with super enamelled copper wire of required grade insulation including dismantling, re-installation, testing etc. as required. item8 30 Each
9 9 Repairing and rewinding of 7.5 HP (discharge capacity- 5.5LPS & head 33-50m) submersible pump set suitable for 415V volts, 3 phase, 50 Hz AC including dismantling, re-installation, testing etc. as required. item9 2 Each
10 10 Lifting and lowering of 3/5/7.5/10/12.5 HP submersible pump from existing borewell upto 100 meter depth. item10 2 Each
11 11 Callibration of following Protection Relays (Make Alstom) installed on 03 nos 11 KV VCB Breaker Panel (01 Incomer + 02 Outgoing) by OEM/ Authorized dealer/ specialized agency inculding cleaning, repairing, testing, submission of reports etc. complete as required.\na) Numerical Communicable IDMT Relay (3 OC + 1 EF) - 03 Nos.\nb) Electromechnical type Master trip Relay -03 Nos.\nc) Tranformer Fault Aux. Relay - 02 Nos item11 1 Job
12 12 Supply of Transformer oil for top up the existing transformer including transportation, loading & unloading etc. as required. item12 100 Ltr
13 13 Dehydration of Transformer oil at site i/c transportation of dehydration machine at site and submisstion of report as required. item13 1520 Ltr
14 14 Collecting transformer oil sample and testing for di-electric strength (BDV value) of oil from authorised testing laboratory and submission of test report as required. item14 4 Each
15 15 Overhauling of Schneider make, HVX model Vacuum Circuit Breakers of 11KV, 630 Amps capacity by OEM/ Authorized dealer/ specialized agency including cleaning, inspection, servicing, repairing, testing etc. complete as required. Cost of spare (if required) shall be paid extra by AAI. item15 3 Each
16 16 Visit charges of service engineer from specialized firm for attending the break down in AMF panel of DG set / LT Panel complete as required. item16 2 Each
17 17 Comprehensive maintenance of different make 1.5 TR Split type airconditioner including comprehensive maintenance of voltage stablizer for one unit per month. item17 36 Job
18 18 Comprehensive maintenance of 5.0 Tr ductable split-type air-conditioner including replacement/ repairs of parts like compressor, gas refilling, capacitor etc. for one unit per month complete as per site requirement. item18 24 Job
19 19 Comprehensive maintenance of different make water cooler of different capacity including replacement/ repairs of parts like compressor, gas refilling, capacitor etc. for one unit per month complete as per site requirement. item19 24 Job
20 20 Comprehensive maintenance of Reverse Osmosis Unit of 10 LPH capacity including replacement/ repairs of parts like filter, membrane, motor etc. for one unit per month complete as per site requirement. item20 12 Job
21 21 Comprehensive maintenance of 50 LPH (Nominal) Reverse Osmosis unit including replacement/ repairs of parts like sediment filter, carbon filter, booster pump, membrane,bacteria's removing system, water level sensor for one unit per month complete as per site requirement. \n(Make : ION Exchange, Model : Zero, B RO Skid 50L) item21 12 Job
22 22 Carrying out D.G. set stack monitoring for parameters like PM, SO2, NO2, CO & HC including taking samples, testing and submission of analysis reports with mandatory parameters from Govt authorized lab, complete as required. item22 4 Each
23 23 Carrying out D.G. set noise monitoring for minimum and maximum including testing, recording data and submission of analysis reports with mandatory parameters from Govt authorized lab, complete as required. item23 4 Each
24 24 Providing & Fixing DOL Starter suitable for 3 phase, 50 Hz, 7.5 HP/10 HP Submersible Pump Set i/c provision for voltage, amp. & ON/OFF Metering also i/c minor civil work complete as per site requirement. (Make : L & T, MU-G15 or equivalent) item24 2 Each
25 25 Supply and fixing of ISI marked Carbon Dioxide (CO2) type fire extinguisher of 4.5 Kg capacity with all accessories conforming to IS-15683:2006 including wheel type release valve, discharge hose not less than 1 meter and 10mm dia, bracket, locking arragement etc. complete with initial filling with CO2 gas as required. item25 3 Each
26 26 Supply, installation, testing and commissioning of ABC type 6 kg Fire Extinguisher confirm to IS 15683:2006 fitted with squeeze grip release valve, locking arrangement, pressure gauge, bracket and other required accessories complete with initial filling as required. item26 3 Each
27 27 Supply of 60 Watt LED Stree/ Roadway Lighting Luminaire with IP65 Protection, die cas aluminium housing suitable for single phase 240 V, 50 Hz AC supply complete as required. item27 10 Each
28 28 Supply of 36 Watt LED Stree/ Roadway Lighting Luminaire with IP65 Protection, die cas aluminium housing suitable for single phase 240 V, 50 Hz AC supply complete as required. item28 10 Each
29 29 Supply of Driver suitable for Gears Energy Make 72 W LED Street Light Fitting suitable for 230 V, 50 Hz AC Power Supply. item29 10 Each
30 30 Supply of Driver suitable for Gears Energy Make 24/25 W LED Street Light Fitting suitable for 230 V, 50 Hz AC Power Supply. item30 10 Each
31 31 Supply of metal Almirah of size approximate 48" x 30" x 18" of thickness 18 G of approved color and make as per direction of Engineer In Charge (Make: Godrej/ Durian/ Evok/ Usha Lexus Wipro/ Hoff) item31 1 Each
32 32 Supply of Mechanic Tool Kit including drill machine, drill bit, hammer, plier etc (BOSCH GSB 550). item32 1 Each
33 33 Supply of variable speed Air-Blower including all accessories. (BOSCH GBL 800E). item33 1 Each
34 34 Supply of 1 x 1.5 Sqmm size FRLS, PVC insulated copper conductor wires suitable for operation of 230 volt single phase 50 Hz AC Supply. item34 100 Mtr
35 35 Supply of 1 x 2.5 Sqmm size FRLS, PVC insulated copper conductor wires suitable for operation of 230 volt single phase 50 Hz AC Supply. item35 100 Mtr
36 36 Supply of 1 x 4.0 Sqmm size FRLS, PVC insulated copper conductor wires suitable for operation of 230 volt single phase 50 Hz AC Supply. item36 100 Mtr
37 37 Supply of 3 x 1.5 Sqmm size FRLS, PVC insulated copper conductor wires suitable for operation of 230 volt single phase 50 Hz AC Supply. item37 50 Mtr
38 38 Supply of 3 x 2.5 Sqmm size FRLS, PVC insulated copper conductor wires suitable for operation of 230 volt single phase 50 Hz AC Supply. item38 50 Mtr
39 39 Supply of 2.5 MFD capacitor suitable for ceiling fan operation on 230 volt 50 Hz single phase AC supply. item39 50 Each
40 40 Supply of 12 V, 180 AH lead acid battery suitable for DG set. item40 2 Each
41 41 CPWD- DSR 2018 (E&M)\nNote: The guidelines for quoting the rate for this item is mentioned in clause 25 (b) of Page GTT-4. item41 75000 Rs.
42 42 CPWD- DSR 2018 (CIVIL)\nNote: The guidelines for quoting the rate for this item is mentioned in clause 25 (b) of Page GTT-4. item42 25000 Rs.