| 1 | 1 | Providing one number skilled manpower in one shift of 8 hour on all days including sundays and holidays (excluding weekly off day) for one month for operation & maintenance of electrical & mechanical installations. | item1 | 72 | Job |
|---|
| 2 | 2 | Providing one number semi-skilled manpower in one shift of 8 hour on all days including sundays and holidays (excluding weekly off day) for one month for operation & maintenance of electrical & mechanical installations. | item2 | 48 | Job |
|---|
| 3 | 3 | Providing one number un-skilled manpower in one shift of 8 hour on all days including sundays and holidays (excluding weekly off day) for one month for operation & maintenance of electrical & mechanical installations. | item3 | 96 | Job |
|---|
| 4 | 4 | Comprehensive maintenance of 02 nos. solar powered obstruction light comprising of battery bank, charger, light assembly, solar panel, controls cards, PV panels, flashers unit, ammeter, voltmeter etc. installed at Jagatpura & Jhalana Hills including replacement/ repairs of all consumables, spares, materials etc. complete as required. | item4 | 12 | Month |
|---|
| 5 | 5 | Repairing and rewinding of fan motor of desert cooler/room cooler with super enamelled copper wire of required grade insulation including dismantling, re-installation, testing etc. as required. | item5 | 30 | Each |
|---|
| 6 | 6 | Repairing and rewinding of fan motor of 300 mm dia exhaust fan with super enamelled copper wire of required grade insulation including dismantling, re-installation, testing etc. as required. | item6 | 15 | Each |
|---|
| 7 | 7 | Repairing and rewinding of fan motor of 450 mm dia exhaust fan with super enamelled copper wire of required grade insulation including dismantling, re-installation, testing etc. as required. | item7 | 15 | Each |
|---|
| 8 | 8 | Repairing and rewinding of fan motor of ceiling fan/wall fan with super enamelled copper wire of required grade insulation including dismantling, re-installation, testing etc. as required. | item8 | 30 | Each |
|---|
| 9 | 9 | Repairing and rewinding of 7.5 HP (discharge capacity- 5.5LPS & head 33-50m) submersible pump set suitable for 415V volts, 3 phase, 50 Hz AC including dismantling, re-installation, testing etc. as required. | item9 | 2 | Each |
|---|
| 10 | 10 | Lifting and lowering of 3/5/7.5/10/12.5 HP submersible pump from existing borewell upto 100 meter depth. | item10 | 2 | Each |
|---|
| 11 | 11 | Callibration of following Protection Relays (Make Alstom) installed on 03 nos 11 KV VCB Breaker Panel (01 Incomer + 02 Outgoing) by OEM/ Authorized dealer/ specialized agency inculding cleaning, repairing, testing, submission of reports etc. complete as required.\na) Numerical Communicable IDMT Relay (3 OC + 1 EF) - 03 Nos.\nb) Electromechnical type Master trip Relay -03 Nos.\nc) Tranformer Fault Aux. Relay - 02 Nos | item11 | 1 | Job |
|---|
| 12 | 12 | Supply of Transformer oil for top up the existing transformer including transportation, loading & unloading etc. as required. | item12 | 100 | Ltr |
|---|
| 13 | 13 | Dehydration of Transformer oil at site i/c transportation of dehydration machine at site and submisstion of report as required. | item13 | 1520 | Ltr |
|---|
| 14 | 14 | Collecting transformer oil sample and testing for di-electric strength (BDV value) of oil from authorised testing laboratory and submission of test report as required. | item14 | 4 | Each |
|---|
| 15 | 15 | Overhauling of Schneider make, HVX model Vacuum Circuit Breakers of 11KV, 630 Amps capacity by OEM/ Authorized dealer/ specialized agency including cleaning, inspection, servicing, repairing, testing etc. complete as required. Cost of spare (if required) shall be paid extra by AAI. | item15 | 3 | Each |
|---|
| 16 | 16 | Visit charges of service engineer from specialized firm for attending the break down in AMF panel of DG set / LT Panel complete as required. | item16 | 2 | Each |
|---|
| 17 | 17 | Comprehensive maintenance of different make 1.5 TR Split type airconditioner including comprehensive maintenance of voltage stablizer for one unit per month. | item17 | 36 | Job |
|---|
| 18 | 18 | Comprehensive maintenance of 5.0 Tr ductable split-type air-conditioner including replacement/ repairs of parts like compressor, gas refilling, capacitor etc. for one unit per month complete as per site requirement. | item18 | 24 | Job |
|---|
| 19 | 19 | Comprehensive maintenance of different make water cooler of different capacity including replacement/ repairs of parts like compressor, gas refilling, capacitor etc. for one unit per month complete as per site requirement. | item19 | 24 | Job |
|---|
| 20 | 20 | Comprehensive maintenance of Reverse Osmosis Unit of 10 LPH capacity including replacement/ repairs of parts like filter, membrane, motor etc. for one unit per month complete as per site requirement. | item20 | 12 | Job |
|---|
| 21 | 21 | Comprehensive maintenance of 50 LPH (Nominal) Reverse Osmosis unit including replacement/ repairs of parts like sediment filter, carbon filter, booster pump, membrane,bacteria's removing system, water level sensor for one unit per month complete as per site requirement. \n(Make : ION Exchange, Model : Zero, B RO Skid 50L) | item21 | 12 | Job |
|---|
| 22 | 22 | Carrying out D.G. set stack monitoring for parameters like PM, SO2, NO2, CO & HC including taking samples, testing and submission of analysis reports with mandatory parameters from Govt authorized lab, complete as required. | item22 | 4 | Each |
|---|
| 23 | 23 | Carrying out D.G. set noise monitoring for minimum and maximum including testing, recording data and submission of analysis reports with mandatory parameters from Govt authorized lab, complete as required. | item23 | 4 | Each |
|---|
| 24 | 24 | Providing & Fixing DOL Starter suitable for 3 phase, 50 Hz, 7.5 HP/10 HP Submersible Pump Set i/c provision for voltage, amp. & ON/OFF Metering also i/c minor civil work complete as per site requirement. (Make : L & T, MU-G15 or equivalent) | item24 | 2 | Each |
|---|
| 25 | 25 | Supply and fixing of ISI marked Carbon Dioxide (CO2) type fire extinguisher of 4.5 Kg capacity with all accessories conforming to IS-15683:2006 including wheel type release valve, discharge hose not less than 1 meter and 10mm dia, bracket, locking arragement etc. complete with initial filling with CO2 gas as required. | item25 | 3 | Each |
|---|
| 26 | 26 | Supply, installation, testing and commissioning of ABC type 6 kg Fire Extinguisher confirm to IS 15683:2006 fitted with squeeze grip release valve, locking arrangement, pressure gauge, bracket and other required accessories complete with initial filling as required. | item26 | 3 | Each |
|---|
| 27 | 27 | Supply of 60 Watt LED Stree/ Roadway Lighting Luminaire with IP65 Protection, die cas aluminium housing suitable for single phase 240 V, 50 Hz AC supply complete as required. | item27 | 10 | Each |
|---|
| 28 | 28 | Supply of 36 Watt LED Stree/ Roadway Lighting Luminaire with IP65 Protection, die cas aluminium housing suitable for single phase 240 V, 50 Hz AC supply complete as required. | item28 | 10 | Each |
|---|
| 29 | 29 | Supply of Driver suitable for Gears Energy Make 72 W LED Street Light Fitting suitable for 230 V, 50 Hz AC Power Supply. | item29 | 10 | Each |
|---|
| 30 | 30 | Supply of Driver suitable for Gears Energy Make 24/25 W LED Street Light Fitting suitable for 230 V, 50 Hz AC Power Supply. | item30 | 10 | Each |
|---|
| 31 | 31 | Supply of metal Almirah of size approximate 48\" x 30\" x 18\" of thickness 18 G of approved color and make as per direction of Engineer In Charge (Make: Godrej/ Durian/ Evok/ Usha Lexus Wipro/ Hoff) | item31 | 1 | Each |
|---|
| 32 | 32 | Supply of Mechanic Tool Kit including drill machine, drill bit, hammer, plier etc (BOSCH GSB 550). | item32 | 1 | Each |
|---|
| 33 | 33 | Supply of variable speed Air-Blower including all accessories. (BOSCH GBL 800E). | item33 | 1 | Each |
|---|
| 34 | 34 | Supply of 1 x 1.5 Sqmm size FRLS, PVC insulated copper conductor wires suitable for operation of 230 volt single phase 50 Hz AC Supply. | item34 | 100 | Mtr |
|---|
| 35 | 35 | Supply of 1 x 2.5 Sqmm size FRLS, PVC insulated copper conductor wires suitable for operation of 230 volt single phase 50 Hz AC Supply. | item35 | 100 | Mtr |
|---|
| 36 | 36 | Supply of 1 x 4.0 Sqmm size FRLS, PVC insulated copper conductor wires suitable for operation of 230 volt single phase 50 Hz AC Supply. | item36 | 100 | Mtr |
|---|
| 37 | 37 | Supply of 3 x 1.5 Sqmm size FRLS, PVC insulated copper conductor wires suitable for operation of 230 volt single phase 50 Hz AC Supply. | item37 | 50 | Mtr |
|---|
| 38 | 38 | Supply of 3 x 2.5 Sqmm size FRLS, PVC insulated copper conductor wires suitable for operation of 230 volt single phase 50 Hz AC Supply. | item38 | 50 | Mtr |
|---|
| 39 | 39 | Supply of 2.5 MFD capacitor suitable for ceiling fan operation on 230 volt 50 Hz single phase AC supply. | item39 | 50 | Each |
|---|
| 40 | 40 | Supply of 12 V, 180 AH lead acid battery suitable for DG set. | item40 | 2 | Each |
|---|
| 41 | 41 | CPWD- DSR 2018 (E&M)\nNote: The guidelines for quoting the rate for this item is mentioned in clause 25 (b) of Page GTT-4. | item41 | 75000 | Rs. |
|---|
| 42 | 42 | CPWD- DSR 2018 (CIVIL)\nNote: The guidelines for quoting the rate for this item is mentioned in clause 25 (b) of Page GTT-4. | item42 | 25000 | Rs. |
|---|