}

Purchase Of Different Types Of Consumable Valves,Rings &Conduits Items For Ctvs Department On 2 Year Rate Contract Basis Part Ii, CNC AIIMS, NEW DELHI-Delhi

All India Institute Of Medical Sciences-AIIMS has published Purchase Of Different Types Of Consumable Valves,Rings &Conduits Items For Ctvs Department On 2 Year Rate Contract Basis Part Ii. Submission Date for this Tender is 07-12-2020. Valve Tenders in CNC AIIMS, NEW DELHI Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

25779623
Corrigendum : Purchase Of Different Types Of Consumable Valves,Rings &Conduits Items For Ctvs Department On 2 Year Rate Contract Basis Part Ii
National Competitive Bid
Indian
Delhi
CNC AIIMS, NEW DELHI
07-12-2020

Tender Details

Purchase Of Different Types Of Consumable Valves, Rings &Conduits Items For Ctvs Department On 2 Year Rate Contract Basis Part Ii-2 Bovine Jugular Vein Conduit ( Size 22 ) N• Suitable For Reconstruction Or Replacement Of The Natural Right Ventricular Outflow Tract ( Rvot ) . N• Un-Stented N• Preserved In Buffered Glutaraldehyde N• No Thawing Or Preclotting Should Be Required N• Trileaflet Venous Valve N 3 Bio Prosthesis Stented Porcine ( Mitral ) ( All Sizes ) N N• Should Be Latest Generation Native Asymmetrical Porcine Tissue Valve, N• Should Have More Than Fifteen-Year Durability Clinical Data, N• Should Have Aoa Tissue Treatment To Mitigate Calcification & Physiological Fixation N• Should Have Flexible Acetyl Homopolymer Stent& Cinch Ii Implant System N 4 Bio Prosthesis Stented Porcine ( Aortic ) ) ( All Sizes ) N N• Should Be Latest Generation Native Asymmetrical Porcine Tissue Valve, N• Should Have More Than Fifteen-Year Durability Clinical Data, N• Should Have Aoa Tissue Treatment To Mitigate Calcification & Physiological Fixation N• Should Have Flexible Acetyl Homopolymer Stent& Cinch Ii Implant System N 5 Bovine Pericardial, Suprannular Aortic Valve ( All Sizes ) N• Should Have Aoa Tissue Treatment To Mitigate Calcification & Physiological Fixation N• Should Have Three Laser Cut Pericardial Leaflets. N• Soft And Pliable Sewing Cuff. N• Lower Valve Profile And Narrow Commissure Posts N• Streamlined Valve Holder To Improves Visibility In Both Standard And Minimally Invasive Approaches. N• Simple One-Cut Release N• Base Frame Impregnated With Barium Sulphate N 6 Artificial Heart Valve, Bileaflet, Mechanical, Mitral, All Sizes N• Rotatable Design, Leaflets Made Up Of Pyrolytic Carbon / Standard Durable Alloy And Polyester Sewing Cuff. N• Should Have Low Profile Height. N• Should Have Minimum Vertical Leaflet Exposure To Result In No Lvot Obstruction N• Should Have Greater Posterior Wall Clearance N• Wide Range Of Sizes. N• Long-Term Clinical Data Should Be Available, Establishing Durability & Consistency In Hemodynamic Performance. N 7 Artificial Heart Valve, Bileaflet, Mechanical, Aortic, All Sizes N• Rotatable Design, Leaflets Made Up Of Pyrolytic Carbon / Standard Durable Alloy And Polyester Sewing Cuff. N• Should Have Low Profile Height. N• High Performance Index. N• Wide Range Of Sizes. N• Long-Term Clinical Data Should Be Available, Establishing Durability & Consistency In Hemodynamic Performance. N 8 Artificial Heart Valve, Bileaflet, Mechanical, Supra-Annular, Aortic, All Sizes N• Rotatable Design, Leaflets Made Up Of Pyrolytic Carbon / Standard Durable Alloy And Polyester Sewing Cuff. N• Should Have Low Profile Height. N• High Performance Index. N• Wide Range Of Sizes.Size 16 Or Smaller Should Be Available. N• Long-Term Clinical Data Should Be Available, Establishing Durability & Consistency In Hemodynamic Performance. N 9 Artificial Heart Valve, Bileaflet, Mechanical, Intra-Suprannular, Aortic, ( Sizes 17-25 ) N• Rotatable Design, Leaflets Made Up Of Pyrolytic Carbon / Standard Durable Alloy And Polyester Sewing Cuff. N• Should Have Low Profile Height. N• High Performance Index. N• Wide Range Of Sizes. N• Long-Term Clinical Data Should Be Available, Establishing Durability & Consistency In Hemodynamic Performance. N 10 Bileaflet Mechanical Aortic Valve With Dacron Conduit ( All Sizes ) N• Should Have Double Velour Woven Graft. N• Should Be Collagen Impregnated To Control Haemostasis And Reduce The Haemorrhagic Complications. N• Should Have Mechanical Heart Valve With Low-Pressure Gradients. With Pivot Guard Design And Leaflet Opening And >75 Degrees. N• Cuff Design Should Enhance Implantability. N• Should Have Minimum Taper Conduit To Facilitate Strong Coronary Anastomosis. N• Should Not Have Any Pleats To Allow Easier Positioning And Attachment Of The Coronary Arteries. N• Wide Range Of Sizes From 19Mm- 33Mm. N 11 Expanded Cuff, Bileaflet Mechanical Aortic Valve With Dacron Conduit ( All Sizes ) N• Should Have Double Velour Woven Graft. N• Should Be Collagen Impregnated To Control Haemostasis And Reduce The Haemorrhagic Complications. N• Should Have Mechanical Heart Valve With Low-Pressure Gradients. N• Expanded Cuff For Ease Of Suturing. N• Should Have Minimum Taper Conduit To Facilitate Strong Coronary Anastomosis. N• Should Not Have Any Pleats To Allow Easier Positioning And Attachment Of The Coronary Arteries. N 12 Monoleaflet, Tilting Disc, Mechanical, Mitral, All Sizes. N• A Monolithic Frame Carved Out Of A Single Block Of Chrome Cobalt Alloy. N• An Occluder Made From Touch And Durable Ultra High Molecular Weight Polyethylene. N• Should Provide Silent Operation And Low Cavitation. N• A Sewing Ring Made From Knitted Polyester. N• Supra-Annular Design. N• Rotatable N• Rotatable N 13 Monoleaflet, Tilting Disc, Mechanical, Mitral, All Sizes N• A Monolithic Frame Carved Out Of A Single Block Of Chrome Cobalt Alloy. N• An Occluder Made From Touch And Durable Ultra High Molecular Weight Polyethylene. N• Should Provide Silent Operation And Low Cavitation. N• A Sewing Ring Made From Knitted Polyester. N• Intra-Annular Design. N• Rotatable N 14 Percutaneous Aortic Valve System Of Size 23-34Mm With Supra-Annular Self Expanding Nitinol Frame With Porcine Pericardium With Compatible Delivery Catheter And Loading System ( Prototype Evolut R, Medtronic ) 15 Percutaneous Aortic Valve System Of Size 23-34Mm With Supra-Annular Self Expanding Nitinol Frame With Porcine Pericardium& External Skirt With Compatible Delivery Catheter And Loading System ( ( Prototype Evolut Pro, Medtronic ) 16 Percutaneous Aortic Valve Of Size 20- 29 Mm With Intra-Annular Balloon Expandable Cobalt-Chromium Frame With Bovine Pericardial Tissue With Compatible Delivery Catheter And Loading System ( Prototype: Sapien 3 / Myval ) N N

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Nov-2020 Corrigendumafterprebid Date 07-12-2020

Key Value

Document Fees
Refer document
EMD
INR 50000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Purchase of Diff.types of consumable valves,rings &conduits items for CTVS Department on 2 year Rate Contract Basis Part II
Sl. No. Item Description Item Code / Make Quantity Units
1 1.001 Purchase of Diff.types of consumable valves,rings &conduits items for CTVS Department on 2 year Rate Contract Basis Part II
2 1.01 Bovine Jugular Vein Conduit (Size 22)\n• Suitable for reconstruction or replacement of the natural right ventricular outflow tract (RVOT).\n• Un-stented\n• Preserved in buffered glutaraldehyde\n• No thawing or preclotting should be required\n• Trileaflet venous valve\n item1 16 pices
3 2 Bio prosthesis Stented Porcine (Mitral) (All sizes)\n \n• Should be latest generation Native asymmetrical Porcine tissue valve,\n• Should have more than fifteen-year durability clinical data, \n• Should have AOA tissue treatment to mitigate calcification & Physiological fixation \n• Should have Flexible acetyl homopolymer stent& Cinch II Implant system\n item2 200 pices
4 3 Bio prosthesis Stented Porcine (Aortic)) (All sizes)\n \n• Should be latest generation Native asymmetrical Porcine tissue valve,\n• Should have more than fifteen-year durability clinical data, \n• Should have AOA tissue treatment to mitigate calcification & Physiological fixation \n• Should have Flexible acetyl homopolymer stent& Cinch II Implant system\n item3 200 pices
5 4 Bovine Pericardial, Suprannular Aortic Valve (all sizes)\n• Should have AOA tissue treatment to mitigate calcification & Physiological fixation \n• Should have three laser cut pericardial leaflets.\n• Soft and pliable sewing cuff.\n• Lower valve profile and narrow commissure posts \n• Streamlined valve holder to improves visibility in both standard and minimally invasive approaches.\n• Simple one-cut release\n• Base frame impregnated with Barium Sulphate \n item4 20 pices
6 5 Artificial heart valve, bileaflet, mechanical, mitral, all sizes\n• Rotatable design, leaflets made up of pyrolytic carbon / standard durable alloy and polyester sewing cuff. \n• Should have low profile height. \n• Should have minimum vertical leaflet exposure to result in NO LVOT obstruction \n• Should have greater posterior wall clearance \n• Wide range of sizes.\n• Long-term clinical data should be available, establishing durability & consistency in hemodynamic performance.\n item5 30 pices
7 6 Artificial heart valve, bileaflet, mechanical, aortic, all sizes\n• Rotatable design, leaflets made up of pyrolytic carbon / standard durable alloy and polyester sewing cuff. \n• Should have low profile height. \n• High performance index.\n• Wide range of sizes.\n• Long-term clinical data should be available, establishing durability & consistency in hemodynamic performance.\n item6 30 pices
8 7 Artificial heart valve, bileaflet, mechanical, supra-annular, aortic, all sizes\n• Rotatable design, leaflets made up of pyrolytic carbon / standard durable alloy and polyester sewing cuff. \n• Should have low profile height. \n• High performance index.\n• Wide range of sizes.Size 16 or smaller should be available.\n• Long-term clinical data should be available, establishing durability & consistency in hemodynamic performance.\n item7 20 pices
9 8 Artificial heart valve, bileaflet, mechanical, intra-suprannular, aortic, (Sizes 17-25)\n• Rotatable design, leaflets made up of pyrolytic carbon / standard durable alloy and polyester sewing cuff. \n• Should have low profile height. \n• High performance index.\n• Wide range of sizes.\n• Long-term clinical data should be available, establishing durability & consistency in hemodynamic performance.\n item8 20 pices
10 9 Bileaflet mechanical aortic valve with Dacron conduit (All sizes)\n• Should have double velour woven graft. \n• Should be collagen impregnated to control haemostasis and reduce the haemorrhagic complications. \n• Should have mechanical heart valve with low-pressure gradients. With pivot guard design and leaflet opening and >75 degrees.\n• Cuff design should enhance implantability. \n• Should have minimum taper conduit to facilitate strong coronary anastomosis. \n• Should not have any pleats to allow easier positioning and attachment of the coronary arteries. \n• Wide range of sizes from 19mm- 33mm. \n item9 140 pices
11 10 Expanded cuff, Bileaflet mechanical aortic valve with Dacron conduit (All sizes)\n• Should have double velour woven graft. \n• Should be collagen impregnated to control haemostasis and reduce the haemorrhagic complications. \n• Should have mechanical heart valve with low-pressure gradients. \n• Expanded cuff for ease of suturing.\n• Should have minimum taper conduit to facilitate strong coronary anastomosis. \n• Should not have any pleats to allow easier positioning and attachment of the coronary arteries. \n item10 20 pices
12 11 Monoleaflet, tilting disc, mechanical, Mitral, All sizes.\n• A monolithic frame carved out of a single block of Chrome Cobalt alloy.\n• An occluder made from touch and durable Ultra High Molecular Weight Polyethylene.\n• Should provide silent operation and low cavitation.\n• A sewing ring made from knitted Polyester. \n• Supra-annular design. \n• Rotatable\n• Rotatable\n item11 30 pices
13 12 Monoleaflet, tilting disc, mechanical, Mitral, All sizes\n• A monolithic frame carved out of a single block of Chrome Cobalt alloy.\n• An occluder made from touch and durable Ultra High Molecular Weight Polyethylene.\n• Should provide silent operation and low cavitation.\n• A sewing ring made from knitted Polyester. \n• Intra-annular design. \n• Rotatable\n item12 20 pices
14 13 Percutaneous Aortic Valve system of size 23-34MM with Supra-Annular Self Expanding Nitinol frame with Porcine Pericardium with compatible delivery catheter and loading system (Prototype Evolut R, Medtronic) item13 30 pices
15 14 Percutaneous Aortic Valve system of size 23-34MM with Supra-Annular Self Expanding Nitinol frame with Porcine Pericardium& external skirt with compatible delivery catheter and loading system ((Prototype Evolut Pro, Medtronic) item14 20 pices
16 15 Percutaneous Aortic Valve of Size 20- 29 MM with Intra-annular Balloon Expandable cobalt-chromium frame with bovine pericardial tissue with compatible delivery catheter and loading system (Prototype: SAPIEN 3 / Myval )\n\n item15 20 pices
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail