Water Resources and Irrigation Government Departments Closing in 0 days TDR #25767268

Revival Of Sarapal-Ii Rl Project Under Reamal Block In Deogarh District Revival Of Sarapal-Ii Rl Project Under Reamal Block In Deogarh District

Issued by Government Departments · Reamal, Odisha
Tender Value
13.63 Lakhs
Estimated cost
Bid Submission
03 Nov 2020
0 days left
EMD
13636
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Reamal → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Revival Of Sarapal-Ii Rl Project Under Reamal Block In Deogarh District Revival Of Sarapal-Ii Rl Project Under Reamal Block In Deogarh District

BOQ

Name of Work : Revival and Energisation of Sarapal-II L.I. Project under Reamal Block in Deogarh District of L.I. Division, Sambalpur
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Part-ABI01010001010000000000000515BI0100001112
22Earthwork in excavation of foundation in hard soil including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-in-charge.699.58cum
33Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge.321.75cum
44Cement concrete (1:4:8) with 4cm size h.g.b. crusher broken metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. complete as per the direction of the Engineer-incharge.2.25cum
55Brick work with K.B. Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6)in foundation & plinth complete as per the Engineer-incharge4.13cum
66Cement concrete (1:2:4) with 12mm size black h.g.b. crusher broken chips of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc complete as per the direction of the Engineer-incharge.0.19cum
77Rigid smooth centering & shuttering for R.C.C. works including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-incharge\n(a) Roof slab, chajja, carnice etc3.48sqm
88(b) Walla & fins58.38sqm
99Labour charges for MS reinforcement for RCC work including cutting, bending & tying the grills and placing in position including cost of binding wire 18 to 20 gauge & HYSD steel bar ( FE 415/ FE 500 )4.98qnttl.
1010R.C.C. work in C.C. (1:2:4) including hoisting & laying & curring for 28days using 12mm. Size clean black hard granite crusher broken chips of approve quality and from approve quarry including cost taxes conveyance charges of all materials to the worksite with supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.5.56cum
111112mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.88.34sqm
1212Cement punning over plastering including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.83.85sqm
1313Fitting of un plasticised 160 mm dia meter dia PVC Pipe for all classes including jointing the pipe with solvent cement by non-head application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. including cost of PVC Pipe, cost of Solvent Cement, transportation of Pipe complete including conveyance pipe from village to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge.408Mtr.
1414Fitting of un plasticised 200 mm dia meter dia PVC Pipe for all classes including jointing the pipe with solvent cement by non-head application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. including cost of PVC Pipe, cost of Solvent Cement, transportation of Pipe complete including conveyance pipe from village to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge.444Mtr.
1515Supplying of 160 mm dia unplasticised rigid UPVC pipe ivory grey in colour having specific gravity of 1.40 to 1.46 gms/ cc of straight length of 6 (six) meter for potable water supplies conforming to IS - 4985/ 2000 of BIS - Ammendment - 2 read with Table - 1 of IS - specification bearing ISI marks for working pressure Cl - 1 UPVC pipe to withstand pressure of 2.5 kgf/cm² & the specification and manufacturer's name should be prominently marked on body of each pipe as per the latest Ammendment of IS - 4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be conducted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubanweswar, necessary approval of authority including transportation to work site in complete shape408Mtr.
1616Supplying of 200 mm dia unplasticised rigid UPVC pipe ivory grey in colour having specific gravity of 1.40 to 1.46 gms/ cc of straight length of 6 (six) meter for potable water supplies conforming to IS - 4985/ 2000 of BIS - Ammendment - 2 read with Table - 1 of IS - specification bearing ISI marks for working pressure Cl - 1 UPVC pipe to withstand pressure of 2.5 kgf/cm² & the specification and manufacturer's name should be prominently marked on body of each pipe as per the latest Ammendment of IS - 4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be conducted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubanweswar, necessary approval of authority including transportation to work site in complete shape444Mtr.
1717Filling the foundation and plinth with excavated material as directed by the Engineer-incharge. A) Hard Soil662.08100 Cum
1818Filling the foundation and plinth with excavated material as directed by the Engineer-incharge. A) Hard Soil14.9Cum
1919Rough stone dry packing in approns & revetments with hard granite stone (15cm to 30cm)25.5Sqm
2020Monoblock pumpset total head of 20 mtr capable to discharge 1700 LPM with 12.5 HP/9.4 KW squirrel cage induction motor fitted with bronze impeller TB-2 of iS 318/1981, companion flanges & class 'F' insulation suitable for operation 415 volt + 6% - 15%, 3 phasde, 50 Hz aC power supply, suction/delivery = 100x100 mm with BEE star rated energy efficiency pump & as per IS-9079/2002 with overall efficiency 62 to 65% of reputed brand having wide dealership network for easy availibility of spares1No.
2121Control panel with automatic star delta starter sheet steel enclosure vsuitable for operation of squirrel cage induction motor up to 15 HP with 16 Amp.(AC-3) duty contractor at 415 volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 8.9 to 13.5 Amp & No volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The starter should provide dependable protection against over load and single phasing fitted with Volt meter, Ammeter, MCB in complete shape including indicator lamp1No.
2222Motor Hood (size 0.45x0.45x0.60 mtr ) made with 18 SWG cold rolled mS sheet with one coat of red oxide primer and two coats of smoke gray / navy blue enamel paint both side (inside & outside) suitable to cover centrifugal monoblock Pump set from 10 to 15 HP and having provision for attachment with the groves on rear side of the panel board1No.
2323Base frame for panel ( size 0.40x0.20 m )and for Motor ( size 0.50x0.27 m ) made with 3\" size MS channel having suitable holes for fitting of Panel board and different size & make 3 phase centrifugal monoblock pumpset from 10 to 15 HP, coloured with one coat of red oxide primer and two coats of smoke gray enamel paint1No.
24243 x 16 mm² Tarpedore cable XLPE ( cross link polyethylin ) confirming to IS: 7098 (Part-II) including laying below 0.90 mtr of the ground and filling the excavated materials including watering and ramming60Mtr.
2525100 mm dia nominal bore GI pipe having wall thickness 4.5 mm electrical resistance welded of medium class confirming to IS - 1239 (pt - 1 of 2004) with socketed at one end and the other end protected with plastic thread protector. The socket confirming to IS - 1239 (pt - II / 1992) with latest amendments in random length of 4 to 7 mtrs. Each pipe should bear ISI certification & manufacturer's name/ trademark36Mtr.
2626100 mm dia GI Bend IS No. 1239(pt-II/1992)4No.
2727100 mm dia GI flange IS No. 6392 / 197122No.
2828100x100x25 mm GI Tee with plug for priming1No.
2929200 mmx100 mm PVC/G.I./M.S. Reducer1No.
3030100mm C.I. Foot Valve should be of swing type friction less with single disc confirming to iS - 4038/1979 of reputed brand1No.
3131100mm C.I. N.R. Valve double flanged swing type PN - 1.0 as per IS:5312 part - I with by-pass aarrangement1No.
323250 mm dia CI AR valve with saddle and riser pipe confirming to IS 14845 with ISI mark2No.
3333200 mm dia PVC Equal tee ( 4 kgf/cm²) confirming to IS - 4995 / 1988 with latest ammendment4No.
3434200 mm dia PVC Bend ( 135?/90?) ( 4 kgf/cm²) agricultiral PVC fittings confirming to IS - 4995/1988 with latest ammendment1No.
3535200 mm dia PVC end cap ( 10 kgf/cm²) confirming to IS - 4995/1988 with latest ammendment2No.
3636160 mm dia PVC End cap (10 kgf/cm²) confirming to IS - 4995/1988 with latest ammendment4No.
3737160x160x110 mm PVC/GI Raiser tee set with bend closing and opening arrangement8No.
3838160 mm dia PVC coupler ( 4 kgf/cm²) agricultiral PVC fittings confirming to IS - 4995/1988 with latest ammendment4No.
3939200 mm dia PVC coupler ( 4 kgf/cm²) agricultiral PVC fittings confirming to IS - 4995/1988 with latest ammendment4No.
4040200 X 160 mm PVC Reducer4No.
4141200 mm dis MS pipe (Medium Duty ) 5.4 mm thick12Mtr.
4242200 mm dia MS slippon flange4No.
4343Construction of out let for Tee Tank8No.
4444Supply of small T & P Kit comprising of hand gloves - 1 pair, tester - 1 no, 8\" cutting plier - 1 no, 12\" sly wrench - 1 no, 12\" screw driver - 1 no, 24/27 & 21/23 DE spanner - 2 nos, 24/27 & 21/23 Ring spanner - 2 nos of Taparia make1No.
4545Labour charges for installation of 15 HP MB Motors including transportation from village to work site, fitting & fixing of base frame, fitting & fixing suction and delivery pipe to motor, other fitting materials including cutting, welding etc. complete as per the direction of the Engineer-incharge.1No.
4646Labour charges for installation of 12.5 HP MB/Open wll submersible Motors including fitting & fixing of base frame, fitting & fixing suction and delivery pipe to motor, NR Valve, Foot Valve and other fitting materials including cutting, welding etc. complete as per the direction of the Engineer-incharge.1No.
4747Part-BBI01010001010000000000000515BI0100001161
4848Construction of 3 phase 11 KV Line as per REC standard confirming to RE Rules 1956 with 300Kg. 9 mtrs.long PSC Pole ( cost excluded ) support in 80Mtrs. Span 55 sqm. AAA Conductor, 11 KV \"V\" cross arm with required nos.of 11KV T &C disc.Insulators and 11KV Pin insulator,carping & padding of poles, danger board at each pole,anticlimbing devices. Stay set at each bending Point and double stay at end point with 18mm G.I. H.T. Stay, concreting of stay with anchor plate,guarding at road crossing etc. including cost of materials,labours, transportation, inspection and commissionng etc. complete.0.2K.M.
4949Cost of materials for 11/0.4 KV, 25 KVA Sub-Station without pole & Transformer.1No.
5050Cost of 11/0.4 KV, 25 KVA Transformer BIS Level-II1No.
51519 mtr 300 kg PSC pole4No.
5252Barbed wire fencing with metal spreading1No.
5353Spike provisin2No.
5454Electrical Earthing2No.

AI Tender Summary

OUR REF NO 25767268
AUTHORITY Government Departments
TENDER VALUE 13.63 Lakhs
LAST DATE 03-11-2020
Authority
Authority Name Orissa Lift Irrigation Corporation Limited
Work Description Revival Of Sarapal-Ii Rl Project Under Reamal Block In Deogarh District Revival Of Sarapal-Ii Rl Project Under Reamal Block In Deogarh District
Basic Detail
Tender No EEOLICSBP-05/2020-21
Bidding Type Tender
Location
City Reamal
State Odisha
Key Dates
Publish Date 20 Oct 2020
Submission Date 03 Nov 2020
Open Date 04 Nov 2020
Finance
Tender Value 13.63 Lakhs
Tender Fee 6000
EMD 13636
Exemption Not Available
Document List
BOQ_331336.xls
Tendernotice_1.pdf
78FA572E-B26F-487B-848B-0F20F4291562.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 20, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 03, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 04, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_331336.xls

pdf

Tendernotice_1.pdf

html

78FA572E-B26F-487B-848B-0F20F4291562.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders