| 1 | 0.01 | NOTE: Schedule ‘A’ Part I to XII are under Ser No. 1.00 to 12.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. | | | |
|---|
| 2 | 1 | Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I.\n\n | | 1 | Lumpsum |
|---|
| 3 | 2 | Lump sum price worked out for Earthwork & Excavation as listed in Sch `A’ Part II\n\n | | 1 | Lumpsum |
|---|
| 4 | 3 | Lump sum price worked out for Internal Water Supply as listed in Sch `A’ Part III\n | | 1 | Lumpsum |
|---|
| 5 | 4 | Lump sum price worked out for Internal Electrification as listed in Sch `A’ Part IV\n | | 1 | Lumpsum |
|---|
| 6 | 5 | Lump sum price worked out for Road/Path/Culvert as listed in Sch `A’ Part V\n | | 1 | Lumpsum |
|---|
| 7 | 6 | Lump sum price worked out for Sewage Disposal as listed in Sch `A’ Part VI\n | | 1 | Lumpsum |
|---|
| 8 | 7 | Lump sum price worked out for External Water Supply as listed in Sch `A’ Part VII\n | | 1 | Lumpsum |
|---|
| 9 | 8 | Lump sum price worked out for External Electrification as listed in Sch `A’ Part VIII\n | | 1 | Lumpsum |
|---|
| 10 | 9 | Lump sum price worked out for Lightening Protection in Sch `A’ Part IX | | 1 | Lumpsum |
|---|
| 11 | 10 | Lump sum price worked out for Fire Alarm and Fire Fighting System as listed in Sch `A’ Part X\n | | 1 | Lumpsum |
|---|
| 12 | 11 | Lump sum price worked out for Lifts in Sch `A’ Part XI | | 1 | Lumpsum |
|---|
| 13 | 12 | Lump sum price worked out for Fencing and Gate in Sch `A’ Part XII | | 1 | Lumpsum |
|---|
| 14 | 12.01 | INTERNAL ELECTRIFICATION | | | |
|---|
| 15 | 13 | Supply and fix ceilling fan 1200 mm sweep complete with blade, canopy and down rod and connecting up to and including provision of flexible three core copper conductor cable 23/0.0076 from ceilling rose to connector block complete all as specified and directed | | 208 | EACH |
|---|
| 16 | 14 | Supply and fix exhaust fan 300 mm sweep heavy duty 240 V AC single phase complete with louvers and shutters of any sweep including provision of flexible three core copper conductor cable of 23/ 0.0076 up to ceiling rose and grouting 04 Nos full threaded bolts and nuts etc. complete all as specified and directed (for toilets of JCO's & NCO's only)\n | | 76 | EACH |
|---|
| 17 | 15 | Supply and fix LED bulb 10 watts capacity cool day light (6500K) with B-22 base complete all as specified and directed. Make: Havells cat no. LHLDEBUEML8X010 or equivalent make mentioned in Appendix 'B' as approved by GE. | | 608 | EACH |
|---|
| 18 | 16 | Supply and fix LED batten single tube 1 x 18/20 W (4 feet long) 230v , 6000k Rated CCT energy efficient with atomic ballast bipin holders starter blocks , diffusers etc complete with all accessories intenally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. \nMake: Orient cat ref Model No.LIBT-118-DS or equivalent make mentioned in Appendix 'B' as approved by GE. | | 611 | EACH |
|---|
| 19 | 17 | Supply and fix LED batten single tube 1 x 10 W ( 2 feet long) 230v, 6000k Rated CCT energy efficient with atomic ballast bipin holders starter blocks , diffusers etc complete with all accessories intenally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. \nMake: Orient cat no LBLN 10-C-AL or equivalent make mentioned in Appendix 'B' as approved by GE. | | 12 | EACH |
|---|
| 20 | 18 | Supply and fix Building Security light luminaire LED 22 W 6000K, IP-65 with aesthetically designed sheet aluminium housing and UV stabilised acrylic cover complete with lamp and internal connection including bracket made of 40 mm dia GI ppe light grade fixed with MS clamp of suitable size grouted on wall with suitable nos of screws/bolts/nuts etc. complete all as specified and directed. \nMake: Orient cat no LSFS-022-C or or equivalent make mentioned in Appendix 'B' as approved by GE. | | 17 | EACH |
|---|
| 21 | 19 | Supply and fix MCCB TPN 415 volt 100 Amps, 16 KA, with adjustable thermal and magnetic vertical type including VTPN DB 4 way complete all as specified and directed. | | 9 | EACH |
|---|
| 22 | 20 | Supply and fix MCB Single pole and neutral 230 volt B curve 10 KA. 6 to 32 Amps capacity IP 20 complete all as specified and directed. | | 70 | EACH |
|---|
| 23 | 21 | Supply and fix MCB single pole, 5 to 16 Amp 240 volt 10 KA, IP 20 complete all as specified and directed. | | 432 | EACH |
|---|
| 24 | 22 | Material and labour for sub main wiring with 2 runs of 10 sqmm single core PVC insulated FRLSH multi stranded copper conductor cable dawn through rigid non metallic concealed PVC conduit heavy duty grade ISI marked 25mm dia (external) with wall thickness not less than 1.8mm with conduit accessories and one run of 10.0 sqmm PVC insulated FRLSH multi stranded copper conductor cable as earth continuity conductor and necessary connections for making connection from TPN DB to electric meter and electric meter to SPN DB at indl DU's all as directed.\nNote: 2 runs of 10 sqmm PVC insulated FRLSH multi stranded copper conductor and 1 run of 10.00 sqmm PVC insulated FRLSH multi stranded copper conductor and 1 run of conduit suitable size shall be measured and paid one meter of unit. | | 4615 | RUNNING METRE |
|---|
| 25 | 23 | Supply and fix direct operation electric energy meter single phase 230 volts of range 5-30 Amps,50 Hz, LCD display,accuracy class-1.0,physical port for local communication,load survey memory,calibration LED with event information and battery backup in PVC/synthetic clare transparent box suitable for mounting on wall complete all as specified and directed. \nMake: Secure Model No. S1A101 or equivalent make mentioned in Appendix 'B' as approved by GE. | | 68 | EACH |
|---|
| 26 | 24 | Supply and fix storage type water heater of capacity 25 litrs,copper inner tank,PVC outer cover,glass wool insulation,vertical wall mounted type with two nos. flexible PVC connection pipe 15 mm bore and 450mm long for hot and cold ware connection and one no. plug top 15 Amp complete all as specified and directed. \nMake: Havells Model No. PURO or equivalent make mentioned in Appendix 'B' as approved by GE. | | 68 | EACH |
|---|
| 27 | 24.01 | EXTERNAL WATER SUPPLY | | | |
|---|
| 28 | 25 | Supply and fix ductile iron pipe of 100mm dia, S/S including special class K-7 complete all as specified and directed. | | 450 | RUNNING METRE |
|---|
| 29 | 26 | Supply and fixing, testing and commissioning sluice valve, 100mm dia, heavy duty, class PN 1.6, flanged ends, any pattern, with head wheel and brass spindle, conforming to IS 14846-2000, ISI marked, with jointing material, flanged joint rubber gasket 6mm thick, including suitable size bolts, nuts, washer and rubber gasket complete including taking down of existing sluice valve of any size complete all as specified and directed. | | 2 | EACH |
|---|
| 30 | 27 | Supply and fix foot valve of 80mm dia conforming to IS 4038 heavy duty cast iron ISI marked and fixing up in cast iron water supply main complete all as specified and directed.\n | | 2 | EACH |
|---|
| 31 | 28 | Material and labour for cutting existing GI/DI/CI pipe line any size upto 100mm bore including excavation, earthwork and inserting GI/DI/CI special any side or shape complete all as specified and directed. \nNote : DI/CI special and lead joint to be measured seperately. Contractor to make arrangements to drain out/pump out accumulated water without any extra cost. | | 1 | EACH |
|---|
| 32 | 29 | Material and labour for construction of PCC block masonry valve pit chamber of size 900 x 900 x 750mm (Internal dimensions) with 150m thick PCC foundation 1:4:8 type D-2 using 40mm graded stone aggregate , with 150mm wide offsets alround, block masonry (1:3:6) built in CM 1:6, 150 mm thick coping in PCC 1:2:4 type B-1 finished even and smooth, rendering 15mm thick in cement mortar (1:4) finished even and smooth internally and rendering 15mm thick in cement mortar (1:6) finished fair and even externally including excavation earthwork in any type of soil, returning and filling, removal of surplus spoil to a distance not exceeding 50 metre, 3 mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame embedded in PCC coping with locking arrangement and mild steel hold fast, mild steel handles and painting to steel surfaces with two coats of black synthetic enamel paint over a coat of red oxide primer etc. complete all as specified and directed. | | 2 | EACH JOB |
|---|
| 33 | 30 | Material and labour for construction of PCC block masonry valve pit chamber of size 650 x 650 x 400mm (Internal dimensions) with 150m thick PCC foundation 1:4:8 type D-2 using 40mm graded stone aggregate , with 150mm wide offsets alround, block masonry (1:3:6) built in CM 1:6, 150 mm thick coping in PCC 1:2:4 type B-1 finished even and smooth, rendering 15mm thick in cement mortar (1:4) finished even and smooth internally and rendering 15mm thick in cement mortar (1:6) finished fair and even externally including excavation earthwork in any type of soil, returning and filling, removal of surplus spoil to a distance not exceeding 50 metre, 3 mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame embedded in PCC coping with locking arrangement and mild steel hold fast, mild steel handles and painting to steel surfaces with two coats of black synthetic enamel paint over a coat of red oxide primer etc. complete all as specified and directed. | | 5 | EACH JOB |
|---|
| 34 | 31 | Providing, fixing, testing and commissioning of centrifugal mono block pumpset suitable for operation on AC 3 phase 415 volts of capacity minimum 5LPS and 2880RPM, 50 HZ, 10HP pump and head 40 m and discharge with 1:3:6 PCC foundation and provision of suction pipe suitable medium grade GI pipe of required length complete all as specified and directed. | | 2 | EACH |
|---|
| 35 | 32 | Supply, install, testing and commisioning of LT electric panel board suitable for 3 phase 415 volt of suitable size outdoor type made out of 3mm thick CRCA sheet with angle iron frame of size 40 x 40x 6 mm cubical type complete with air circuit breaker, copper bus bar 400 Amps including multi- functional digital meters to read voltage, current, frequency and power factor, powder coated precoated and having separate compartment for all out going feeders including provision for mounting on suitable PCC platform made of PCC 1:2:4 type B-2 with 40mm graded stone aggregate complete all as specified and directed with and including the following : \n(a) MCCB TP 415 V,40 Amps,4pole,16KA -01 No. (incoming)\n(b) MCB 32 Amps,TPN -02 Nos. (Out going) \n(c) Star delta starter Automatic Suitable for 10 HP (d) Single phase prevetre - 02 Nos.\n(e) Volt meter digital Ammeter 0 to 500 Volt\n(f) Selector switch and LED indicator lamps | | 1 | EACH JOB |
|---|
| 36 | 32.01 | EXTERNAL ELECTRIFICATION | | | |
|---|
| 37 | 33 | Material and labour for stone slab/patti, 40 to 50mm thick, rough dressed, Jodhpur stone slab cover in trenches for protection of cables, 25mm to 35mm wide and 80 cm long, laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed. | | 458 | SQUARE METRE |
|---|
| 38 | 34 | Supply and fix LED street light fittings 25 watt 2m long 40mm dia light grade GI pipe bracket bend in shape fixed on wall with clamps bolt and nuts complete all as specified and directed.\nMake- Crompton Greaves cat no LSTO-25-CDL or equivalent make mentioned in Appendix 'B' as approved by GE. | | 20 | EACH |
|---|
| 39 | 35 | Supply and fix \"Olympus\" type pressure die cast aluminium housing heat rsistant toughened glass with frame IP 66 protection better optics for uniform distribution for street light luminaire 72 watt 230 volts 50 Hz including all necessary fittings accessories and LED lamps including 2.8m long 40mm dia light grade GI pipe bracket bend in shape fixed on wall with clamps bolt and nuts fixed on existing pole with FI clamps 40 x 6 mm complete all as specified and directed.\nMake- Crompton Greaves cat no LSTN-72-CDL or equivalent make mentioned in Appendix 'B' as approved by GE. | | 10 | EACH |
|---|
| 40 | 36 | Supply and fix HDPE junction box for street light central with linked door control including 10 Amp MCB SPN with aluminium bus bar four strip of 100 Amp capacity for controlling the street light complete all as specified and directed. | | 30 | EACH |
|---|
| 41 | 37 | Material and labour for sub main wiring with two runs of 2.5 Sqmm and one run of 2.5 Sqmm PVC insulated unsheathed multistranded copper conductor FRLSH 1100 Volts grade cable with colour code 3 runs drwan through and including rigid steel conduit 20 mm dia, heavy duty, ISI mark secured with the pole surfaces from junction box to street light fittings and HDPE box complete all as specified and as directed.\nNote: All runs of cable and one run of conduit shall be measured and paid as one metre length of unit. | | 200 | RUNNING METRE |
|---|
| 42 | 38 | Supply, install, testing and commisioning of LT electric panel (KIOSK) suitable for 3 phase 415 volt of suitable size outdoor type made out of 3.16mm thick CRCA sheet with angle iron frame of size 40 x 40x 6 mm cubical type complete with air circuit breaker, including multi- functional digital meters to read voltage, current, frequency and power factor, powder coated precoated and having separate compartment for all out going feeders including provision for mounting on suitable PCC platform made of PCC 1:2:4 type B-2 with 40mm graded stone aggregate complete all as specified and directed with and including the following : \n(a) Bus bar chamber of 3 phase and 1 neutral 4 strip 415 volt with 1000 Amps aluminium strip - 1 Set\n(b) MCCB 500 Amps, 4 pole,36 KA with thermal magnetic release- 01 No. \n(c) MCCB 250 Amps, 4 pole,16 KA - 01 No. \n(d) MCCB 100 Amps, 4 pole,16 KA - 08 Nos. \n(e) MCCB 40 Amps, 4 pole,16 KA - 01 No. \n(f) MCB, TPN, 32 Amp, 10KA - 02 Nos. (g) Digital voltmeter 0 to 500 Volts - 01 No.\n(h) Digital Ammeter 0 to 500 Amp - 01 No.\n(j) Selector switch & LED indicator lamps | | 1 | EACH JOB |
|---|
| 43 | 39 | Supply, install, testing and commisioning of LT electric panel suitable for 3 phase 415 volt of suitable size outdoor type made out of 3.16mm thick CRCA sheet with angle iron frame of size 40 x 40x 6 mm cubical type complete with air circuit breaker, including multi- functional digital meters to read voltage, current, frequency and power factor, powder coated precoated and having separate compartment for all out going feeders including provision for mounting on suitable PCC platform made of PCC 1:2:4 type B-2 with 40mm graded stone aggregate complete all as specified and directed with and including the following : \n(a) Bus bar chamber of 3 phase and 1 neutral 4 strip 415 volt with 1000 Amps aluminium strip - 1 Set\n(b) MCCB 500 Amps, 4 pole,36 KA with thermal magnetic release- 02 Nos (for incoming-01 & outgoing-01). (c) Digital voltmeter 0 to 500 Volts - 01 No.\n(d) Digital Ammeter 0 to 500 Amp - 01 No.\n(e) Selector switch & LED indicator lamps | | 1 | EACH JOB |
|---|
| 44 | 40 | Supply and fix aviation light fitting on OH water tank suitable for Double GLS lamp and all connection accessories as nuts, bolts, clamps, bulb 60W complete all as specified and directed. Make WIPRO, Phillips, CG or equivalent make mentioned in Appendix 'B' as approved by GE. | | 4 | EACH |
|---|
| 45 | 40.01 | SEWAGE DISPOSAL | | | |
|---|
| 46 | 41 | Supply and fix SFRC (Steel fibre reinforced concrete) cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter confirming to IS 12592, total weight of cover and frame to be not less than 182 kg fixed in cement concrete 1:2:4 type B-2 with 40mm graded stone aggregate complete all as specified and directed. | | 34 | EACH |
|---|
| 47 | 41.01 | FIRE ALARM AND FIRE FIGHTING SYSTEM | | | |
|---|
| 48 | 42 | Supply installation, testing and commissioning of manual call box (Pillar box) made from 16 SWC CRCA sheet having single LED indication and release type push button in case of FIRE BREAK GLASS printed on front cover and having hammer and chain (for 02 Nos NCO's block) complete all as specified and directed. | | 18 | EACH |
|---|
| 49 | 43 | Supply installation, testing and commissioning of medium intensity electronic hooter (Siren) cum speakeer made from 16 SWG CRCA sheet with circuit having put of 80 db and painted FIRE ALARM complete all as specified and directed. | | 2 | EACH |
|---|
| 50 | 44 | Supply installation, testing and commissioning of push button electronic telephone housed in box made out of 16 SWG CRCA sheet with locking arrangement complete all as specified and directed. | | 2 | EACH |
|---|
| 51 | 45 | Supply and drawing of PVC insulated FRLS, 2x1.5 Sqmm ads per PS conductor copper wire IN the conduit conforming to IS-694 and ISI marked cable complete all as specified and directed. | | 450 | RUNNING METRE |
|---|
| 52 | 46 | Supply and drawing of PVC insulated FRLS, 2x4 Sqmm ads per PS conductor copper wire IN the conduit conforming to IS-694 and ISI marked cable complete all as specified and directed. | | 125 | RUNNING METRE |
|---|
| 53 | 47 | Supply and fix steel conduit 25mm dia complete all as specified and directed. | | 50 | RUNNING METRE |
|---|
| 54 | 48 | Supply and fix self blowing photo signs for indicators complete all as specified and directed. | | 10 | EACH |
|---|
| 55 | 49 | Supply and fix fire hydrant landing valve type A (Single head outlet) of 63mm dia size conforming to IS-5290 complete all as speciifed and directed. | | 18 | EACH |
|---|
| 56 | 50 | Supply and fix branch pipe and nozzle for 20mm dia hose conforming to IS- 8090 including fusible plugs suitable for automatic operation at 135 degree temp complete all as specified and directed | | 18 | EACH |
|---|
| 57 | 51 | Supply and fix hose of 20mm dia and nozzle length 30 metre conforming to IS-5132 complete all as specified and directed. | | 18 | EACH |
|---|
| 58 | 52 | Supply and fix extinguisher having set of 5 Nos. one of dry chemical powder 09 Kg, Light weight squeeze CO2 type extinguiser -10 Nos and water stored pressure type 9 litre capacity-8 Nos, fire buckets with stand (dry sand)-02 Nos, mechanical foam type extinguisher 09 Kg capacity-01 No, fire beaters etc complete all as specified and directed. | | 4 | EACH SET |
|---|
| 59 | 53 | Material and labour for LT/HT cable route indicator including angle iron stand and PCC etc. complete all as speciifed and directed. | | 10 | EACH |
|---|
| 60 | 54 | Supply and fix pump motor set of capacity 900 LPM of 3.5 KG/Cm2 pressure pump complete all as speciifed and directed. | | 2 | EACH |
|---|
| 61 | 55 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including for laying of UG Cable and water pipe line complete all as specified and directed. | | 40 | RUNNING METRE |
|---|