Repair / Maintenance Of Unsv Lt Ug Cable Panels And Connected Wks In Tech Area At Mil Stn Dappar Under Ge ( P ) Dappar, GE (P) Dappar-Punjab

Military Engineer Services-MES has published Repair / Maintenance Of Unsv Lt Ug Cable Panels And Connected Wks In Tech Area At Mil Stn Dappar Under Ge ( P ) Dappar. Submission Date for this Tender is 07-11-2020. LT Cable Tenders in GE (P) Dappar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

25747704
Repair / Maintenance Of Unsv Lt Ug Cable Panels And Connected Wks In Tech Area At Mil Stn Dappar Under Ge ( P ) Dappar
Open Tender
Indian
Punjab
GE (P) Dappar
07-11-2020

Tender Details

Repair / Maintenance Of Unsv Lt Ug Cable Panels And Connected Wks In Tech Area At Mil Stn Dappar Under Ge ( P ) Dappar

Key Value

Document Fees
INR 500 /-
EMD
INR 76000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Repair / Maint of unsv LT UG cable panels and connected wks in Tech Area at Mil Stn Dappar under GE (P) Dappar
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Disconnecting & taking out old unserviceable LT cable of size 120 sq mm 3.5 core. 350 RM
2 2 Disconnecting & Taking out old unserviceable LT cableof size 70 sq mm 3.5 core 400 RM
3 3 Disconnecting & Taking out old unserviceable LT cable of size 50 sq mm 3.5 core 600 RM
4 4 Disconnecting & Taking out old unserviceable LT cable of size 35 sq mm 3.5 core 530 RM
5 5 Disconnecting & Taking out old unserviceable LT cable of size 25 sq mm 4 core 650 RM
6 6 Disconnecting & Taking out old unserviceable LT cable of size 16 sq mm 4 core 450 RM
7 7 Disconnecting & Taking out old unserviceable LT cable of size 10 sq mm 2 core 300 RM
8 8 Supply, laying, jointing, connecting, testing & commissioning UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty 1100 volts grade with standard aluminium conductor of cross sectional area 120 sqmm x 3.5 core all as specified and directed by Engr-in-Charge.\nNOTE - (a). The quoted rate is deemed to be inclusive of arranging respective shutdown, disconnection of cables, commissioning of feeder after the completion of job and inclusive of any minor spares and jobs required for the completion of the job. (c). The cost of excavation, returning, filling, removal and PCC cable covers will be measured and paid under relevant items of this schedule. 350 RM
9 9 Description all as per ser item No 8 here-in-before but size of LT under ground cable 70 sqmm 3.5 core. 400 RM
10 10 Description all as per ser item No 8 here-in-before but size of LT under ground cable 50 sqmm 3.5 core. 600 RM
11 11 Description all as per ser item No 8 here-in-before but size of LT under ground cable 35 sqmm 3.5 core. 530 RM
12 12 Description all as per ser item No 8 here-in-before but size of LT under ground cable 25 sqmm 4 core. 650 RM
13 13 Description all as per ser item No 8 here-in-before but size of LT under ground cable 16 sqmm 4 core. 450 RM
14 14 Description all as per ser item No 8 here-in-before but size of LT under ground cable 10 sqmm 2 core. 300 RM
15 15 Excavation in trenches in soft/loose/hard soil n exc 1.5 m wide and not exc 1.5 m in depth and getting out including forming bottom to required level or slope for laying pipes / laying of cable complete all as specified and as directed by Engineer-in-Charge. 886 Cum
16 16 Returning filling in soft / loose soil in trenches including spreading, leveling and well ramming in 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge. 561 Cum
17 17 Removal of surplus soil to a distance n exc in 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge. 325 Cum
18 18 Material and labour sand cushioning (dry sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness.). Complete all as specified and as directed by Engineer-in-Charge. (Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes). 236 Cum
19 19 M&L precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm. 17493 Each
20 20 Material and labour for galvanized iron tubing size 40 mm bore (Light grade) with all necessary fittings laid in trenches under road crossing or fixed on poles / walls / under floors for cable protectioncomplete all as specfied and as directed. Make:- Jindal. Complete all as specified and as directed by Engineer-in-Charge. 40 RM
21 21 M & L for earthing with galvanised iron earth plate of size 600x600x6mm thick buried directly in ground not less than 2.25m below normal ground level,earth plate packed on all sides with charcoal mixed with salt in alternate layers of 15 cm thickness connected by galvanised iron earth earth strip 32x6mm soldered & riveted toearth plate, galvanised iron earth strip will be provided by using 50mm bore galvanised iron pipe (light grade) earth plate to transformer body and neutral or test point of transformer, including flat iron clamp 25x3mm including bolts, nuts and washers complete including watering galvanised iron pipe 20 mm dia 'Light grade' 2.5mm long the earthing includes PCC pit including necessary earth works and disposal of surplus soil to a distance not less than 50m, chamber of PCC 1:4:8 type D-2 using 40mm graded stone aggregate, coping shall be of PCC 1:3:6 type C-I using 20mm graded stone aggregate, RCC pit cover 50mm thick in1:2:4 type B-I using 20mm graded stone aggregate, rein forced with 8mm dia @ 15cm c/c complete all as shown on sketch No 3 of SSR-I of 2009 and as specified and as directed by Engr-in-Charge. 30 Each
22 22 M & L earth continuity conductor GI of 32x6 mm of GI strip by means of bolts, nuts, check nuts and GI washers complete all as specified. 30 RM
23 23 M & L Synthetic insulating mat (rubber matting), ISI Marked suitable for 1100 Volts electrical grade 2mX1mX2mm thick chequered top, ISI marked to be laid in front of LT panel board complete all as specified and directed. 4 EACH
24 24 M&L for Danger notice boards of 1.6mm thick mild steel sheet, vitreous enamelled white,with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT 25x20cm size. 20 EACH
25 25 M&L for application of two coats of aluminium paint on steel tubular/rail pole of 9/11/13/15 M long externally after removal of old paint, rust, dust, oil, grease or any other foreign deposits by paint removers or burning off by blow lamps, cleaning with scrapers and chemicals for removal of rust for any number of coats of any width or girth incl. numbering of poles in blackbase & white letters paint and incld. painting five no. strips upto 30 cm on bottom of pole with black and yellow colour paint alternately all as specified and directed by Engr-in-Charge. 200 Each
26 26 Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 25 to 50 sqmm, core outdoor type and taking down fault complete all as specified and directed by Engr-in-Charge. Make : Denson/M Seal/Birla 12 Each
27 27 Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB FP, 36kA, 400 AMPS with Thermal - Magnetic Release Type Ics = 100% Icu, Adjustable Over Load setting: 0.4 -1.0 x In, Adjustable short circuit for each phase from 1.5 - 8 x In, Make - L&T, Cat No. - CM98401OOROOG including spreader terminals (Make-L&T, Cat No.-ST98066OOOO). NOTE - Quoted rate is deemed to be inclusive of minor jobs and minor spares required for fitment of MCCB in the existing panel. 1 Each
28 28 Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB TP, 25kA, 250 AMPS with Thermal - Magnetic Release Type, Ics = 100% Icu, Adjustable Over Load setting: 0.4 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, Make - L&T, Cat No. -CM90642OOPO including spreader terminals (Make-L&T, Cat No.-ST98066OOOO). 1 Each
29 29 Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, S&F MCCB TP, 25 kA, 200 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, Make - L&T, Cat No. - CM90642OONO including spreader terminals (Make-L&T, Cat No.-ST98066OOOO). 1 Each
30 30 Supply only fuse wire (Tin & Copper) 16/18/20 SWG complete all as specified and as directed by Engr-in-Charge. 6 Kgs
31 31 Taking down unserviceable ACSR conductor and supply and fixing aluminium conductor steel reinforced any type complete all as specified and as directed by Engr-in-Charge. 4 Qtl
32 32 Restringing and Fixing ACSR Conductor reinforced of any size to proper sag incl binding on insulator all as specified and as directed by Engr-in-Charge 3200 RM
33 33 Cutting & trimming of tree branches any girth and size around overhead lines to a clear distance 1.5 mtr both sides of overhead line with in a 25 to 40 mtrs span gap of HT/LT lines including clearing the site all as specified and directed by the Engr-in-Charge. 140 Per Span
34 34 M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending, cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide zinc chrome primer including removing old unserviceable rusted ones complete all as directed by Engineer-in-Charge 4 Qtls
35 35 M&L for stay assembly complete with accessories as shown in electric plate No.I including loop type insulator, stay clamps etc complete all as specified & directed with diameter of stay 20 mm of stay rod complete all as specified & directed. \nNote: - Loop type insulator, PCC foundation, Exc & earth work & GI stay strand will be measured and paid seperately under relevent items of Sch 'A' 25 Per Set
36 36 M&L for inspection of LT FPB all connected accessories/components like MCCB/MCB/ACB ON-OFF/Tripping operations, metering devices, cable lugs joints, bus bar connections, insulators, wiring, CTs, etc., cleaning of LT FPB using dry air pressure, vacuuming out all dust/foreign particles using vaccum cleaner complete, removing flash over/burnt carbon particles from cable lug joints, bus bars, etc. with CRC 226 or WD14 or equivalent cleaner, tightening of nuts/bolts and other electric connections, disconnecting all incoming and outgoing connected cables, cutting off burnt portions, crimping with suitable size aluminium/copper lugs and connecting up inclusive of replacement of cable glands (if any) all as directed at site by Engr-in-charge. Note:- (a). All spares like LED indicating lamps, ACB/MCCB/MCB, fuses with holders, voltmeter, ammeter, CTs, selector switches, copper/aluminium bus bar, control wiring, etc. required for replacement shall be measured and paid separately under relevant items of schedule here-in-after however the quoted rate is deemed to be inclusive of cost of cleaning agents, grease, cable lugs, cable glands, nut/bolt and washer combination all as approved by Engr-in-Charge. (b). The contractor has to arrange for electrical shutdown prior to carry own repairs. 15 EACH
37 37 M&L for sheet metal work for replacement of unsv. panel doors, bus bar cover, metering devices/relay mounting doors in complete alignment with panel's existing doors with 3mm thick CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032 or of shade as specified incld. necessary cutting of MS sheet so as to incorporate old serviceable panel accessories like LED indicating lamps, volt/ammeter, selector switches, MCCB/MCB handles, etc. welding and fixing jobs and dismantling of unsv./rusted doors to the complete satisfaction and as directed and specified by Engr-in-Charge. NOTE - (a). The contractor has to arrange for electrical shutdown prior to carry own repairs. (b). The quoted rate is deemed to be inclusive of cost of hinges, panel locks, accessories required for flush fitting of old serviecable LED indicating lamps, volt/ammeter, selector switches, MCCB/MCB handles, etc. on the new door or any other materials required for fixing and proper opereations of door. 120 Kg
38 38 Supply and relplace existing u/s indicating lamp LED type suitable to operate on 230 volts AC Supply of R/Y/B colour as per site requirement all as specified and directed. 35 Each
39 39 S&F in replacement Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO and including suitable size CTs (set of 3) - 04 Nos. (Outgoing feeders) 26 Each
40 40 S&F in replacement Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO and including suitable size CTs (set of 3) - 04 Nos. (Outgoing feeders) 25 Each
41 41 Supply and replace existing u/s selector switch for voltmeter. 30 Each
42 42 Supply and replace existing u/s selector switch for Ammeter 30 Each
43 43 supply and replace existing unserviceable CT as that of existing ratio and model suitable for 3 phase supply 20 Each
44 44 S&F in replacement Street light control junction box 280x170x130mm upto 16 sq mm 4 core cables made out of FRP sheet moulded and arrangement of incoming 3 phase 4 wire system and out going 3 phase 4 wire system with R.Y.B.& N studs and control for incoming & outgoing cables with MCB SP 2.5 Amps 230 volts with neutral link including flat iron 25x3 mm “D” clamps (2 Nos) suitable to pole of any size including bolts nuts & washers.”NOTE: - The rates includes incoming & outgoing cables glands & lugs of size up to 16 sq mm 4 core. 20 Each
45 45 M&L for dismantling old unserviceable LT panel along with disconnecting connected cables, supplying, installing, testing and commissioning of factory fabricated of size as per the existing IEC norms, floor mounted, IP 55 grade, outdoor type double door type LT cubical panel made out of 3mm thick CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032, dust and veremin proof with suitable size TPN PVC sleeved aluminium bus bar, incld. aluminium bus bars for incoming and outgoing connections supported on glass fiber reinforced thermosetting plastic insulated support with lifting lugs of suitable size. Panel should be mounted/grouted PCC (1:4:8) type D2 of size on as per the panel dimensions such that there should be 100 mm offsets complete. The bottom of the panel (space between bottom of panel and top of PCC foundation) shall be covered with 3 mm thick CRCA sheet covering all the sides of the base frame duly painted with two coats of synthetic enamel paint of approved shade over one coat of red oxide primer. The panel should have following accessories fitted in :- 1 Each Job
46 46 (i) MCCB 400 Amps ,415 V 4 pole 36 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make : Cat pat No : CM94106OOS1OG including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 01 No. - INCOMING
47 47 (ii) MCCB 320 Amps ,415 V 4 pole 36 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make : Cat pat No : CM98403OOQOOG including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 01 No. - OUTGOING
48 48 (iii) MCCB 200 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM90642OONO including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 02 Nos. - OUTGOING
49 49 (iv) MCCB 100 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM90642OOLO including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 01 No. - OUTGOING
50 50 (v) MCCB 63 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM91712OOHOOG including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 02 Nos. - OUTGOING
51 51 (vi) LED indicators - R/Y/B 240 V AC - 21 Nos. - 03 Nos per Incoming and outgoing feeders.
52 52 (vii) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as per L&T make, Cat No. - WL440010OOOO and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder)
53 53 (viii) Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL132010OOOO and including suitable size CTs (set of 3) - 06 Nos. (Outgoing feeders)
54 54 (ix) Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO and including suitable size CTs (set of 3) - 06 Nos. (Outgoing feeders)
55 55 (x) MCB SP 'C' series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 20 Nos.
56 56 (xi) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc.
57 57 All as per SL Item No. 45 above but panel with following components - 1 Each Job
58 58 INCOMER
59 59 ACB 630 Amps, manual draw out type, four pole, rapturing cap. 50kA, 415V AC, 50Hz incld. Suitable size, type and qty. of terminal adaptors all as per L&T Make, Model - 'C' Power, cat ref. no. - Make-L&T, SL95351 - 01 No.
60 60 OUTGOING
61 61 (i). MCCB 400 Amps ,415 V 4 pole 36 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make : Cat pat No : CM94106OOS1OG including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 02 Nos.
62 62 (ii) Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL132010OOOO and including suitable size CTs (set of 3) - 03 Nos. (Incoming and Outgoing feeders)
63 63 (iii) Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO and including suitable size CTs (set of 3) - 03 Nos. (Incoming and Outgoing feeders)
64 64 (iv). LED INDICATORS - L&T make, CAT NO - HB07E - 09 Nos.
65 65 (V). 6 Amp MCB SP, Legrand Make, CAT No. - 6032 31 - 06 Nos.
66 66 (vi). Locking of ACB in Isolated position (LIP) - Make - L&T, SL93146OOOA - 01 No.
67 67 (vii). Lockable Trip Push Button (LTPB) - Make - L&T, SL93148OOOA - 01 No.
68 68 (viii). Suitable size Al BUS BAR for interconnections.
69 69 Supply and erection of factory made & assembled Double door type LT panel Board of suitable size, dust and vermin proof, fabricated out of 1.6 mm thick CRCA sheet steel, powder coated with 7 tank process, for better environment protection. MCCB Panel Board should be manufactured and supplied by ISO-9001 certified OEM of MCCB. The panel board should be suitable for floor or wall mounting and should be of robust construction. The panel board should have cable alleys on both sides for easy cable termination and should be complete with ammeter, voltmeter, selector switches, fuses, indicating lamps, etc. all as per Havells Cat No- IHLG04000400 or equivalent in L&T Make Model - Emergy-S SMDB, Schneider Make Cat No- Blokset LV Switchboard. 2 Each
70 70 The panel board should comprises of the following items-
71 71 1) Copper Bus Bar of rating equal or higher than the incomer MCCB current rating
72 72 2) Incomer MCCB 400Amp, 4Pole, 36kA breaking capacity with adjustable thermal magnetic release- 1 No Havells Cat No- IHLG04000400 or equivalent in ABB, Schneider - INCOMING
73 73 3) Outgoing MCCB 200Amp, 3Pole, 25kA breaking capacity with adjustable thermal magnetic release - 01 No Make Havells/ABB/Schneider
74 74 4) Outgoing MCCB 160Amp, 3 Pole, 25kA breaking capacity with adjustable thermal magnetic release - 01 No Make Havells/ABB/Schneider
75 75 5) Outgoing MCCB 63Amp, 3 Pole, 25kA breaking capacity with adjustable thermal magnetic release - 01 No Make Havells/ABB/Schneider
76 76 6) Double door Cable Alley I/C 400 A,O/G 3P GF 2/4Way on both sides all as per Havells Cat No- ISSBOU0697 - 01 Set (Each set of Cable Alley consists of two numbers, one each on LHS and RHS) or equivalent in ABB, Schneider
77 77 7) Double door Pre-Wired digital Meter Module with Voltmeter, Ammeter, Selector Switch, Ct’s Control Fuse & Indicating Lights all as per Havells Make Cat No- ISSBOU0707 or equivalent in ABB, Schneider - 01 No.
78 78 8) Add on Incoming Changeover double door Switch Enclosure only suitable for 400 A/630 A Incoming change Over switch all as per Havells Make Cat No. ISSBOU0709 - 01 No. or equivalent in ABB, Schneider, L&T
79 79 9) Automatic Transfer Switch with Controller 400 Amp without enclosure, Four pole with complete connections as per the satisfaction of engineer incharge all as per Havells make Cat No- IHYFCDO400 - 01 no. or equivalent in ABB, Schneider, L&T
80 80 All as per SL Item No. 45 above but panel with following components - 1 Each Job
81 81 INCOMER
82 82 (i) MCCB 63 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM91712OOHOOG including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 01 No.
83 83 (ii) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as per L&T make, Cat No. - WL440010OOOO and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder)
84 84 (iii). LED INDICATORS - L&T make, CAT NO - HB07E - 13 Nos.
85 85 (iv). 6 Amp MCB SP for back supply for Multifunction meter and LED indicator lamps - 03 Nos.
86 86 (v). Ring Type CT 150/5A, 10 VA, CL1 Tape Wounded - 03 Nos.
87 87 APFC SECTION -
88 88 (vi). 10 Amp TP MCB for 25/10/5 KVAR capacitors - 06 Nos
89 89 (vii). Capacitor duty contactor 3 phase with auxilary switch block 415 volts suitable for 5 kVAR 1 NO + 1 NC - 06 Nos.
90 90 (viii). APFC relay of 8 stage supply Voltage 415 V AC and current Input - 1A or 5 A with specs as - 3 Phase Current and Voltage measurement, PF display - 3 Digit after decimal, Individual harmonics measurement up to 31st order, Dual PF setting for Mains - DG application, Communication through Inbuilt MODBUS RS-485 Protocol all as per L&T Cat Part No. CS91050OOOO or eqivalent in Epcos/Schenider/Seimens - 01 No.
91 91 (iX). Rotary Type A/M Switch, 1 Pole, 2 Way with Off - 10 Nos.
92 92 (x). On Delay Timer, 3-120 Secs - 01 No.
93 93 (xi). 3 phase stud mounting cylindrical type, self standing units, self healing property with MPP film with safety device in the form of pressure sensitive (over pressure) mechanical interrupter, 415/440V, 3 phase, 50 Hz, Capacity 5 KVAR capacitor, AC conformance to Standards IEC 60831-1 2/96, IS 13340 - 06 Nos
94 94 (xii). Illuminated Flush Type Start Push Button with 1 NO - 6 Nos
95 95 (xiii). Illuminated Flush Type Start Push Button with 1 NO - 6 Nos
96 96 (xiv). Plastic body exhaust fan of suitable size fitted complete within the panel for heat dissipation purpose generated in the cubicle - 01 No.
97 97 (xv) Suitable size aluminium bus bar for R-Y-B phases.
98 98 M&L for dismantling, disconnecting connected cables of old unserviceable LT FPB, supplying, installing, testing and commissioning of factory fabricated CPRI approved, floor mounted, IP 55 grade, outdoor type LT cubical panel made out of 3mm thick CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032 of size not less than LBW-0.60mX0.60mX0.40m, dust and veremin proof with suitable size TPN PVC sleeved aluminium bus bar, incld. aluminium bus bars for incoming and outgoing connections supported on glass fiber reinforced thermosetting plastic insulated support with lifting lugs of suitable size. Panel should be mounted/grouted on 150 mm thick PCC (1:4:8) type D2 with 100 mm offsets complete. The bottom of the panel (space between bottom of panel and top of PCC foundation) shall be covered with 3 mm thick CRCA sheet covering all the sides of the base frame duly painted with two coats of synthetic enamel paint of approved shade over one coat of red oxide primer. The panel should have following accessories fitted in :- 10 Each Job
99 99 (i) MCCB 63 Amps ,415 V TP pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM9200800L10G-01 including spreader terminals set of 04 direct rotary handle -01Nos or equivalent in legrand/ABB/Schenider
100 100 (ii) LED indicator - R/Y/B 240 V AC - 03 Nos.
101 101 (iii) Analogue Voltmeter having voltage of range : 0-500 V, MAKE - Legrand, CAT No. - 0046 60.
102 102 (iv) Voltmeter selector switch suitable with OFF, 16 Amps. MAKE - L&T, CAT No. - 61312 SCB03TDYR
103 103 (v) Analogue Ammeter having AC range : 0 - 30 A (4 modules) with suitable size resin cast ring type CT-03 Nos. MAKE - Legrand, CAT No. - 0046 02.
104 104 (vi) Ammeter selector switch suitable for line currents. MAKE - L&T, CAT No. - 61325 SCB03TDYR.
105 105 M&L for dismantling old unserviceable LT panel along with disconnecting connected cables, supplying, installing, testing and commissioning of factory fabricated of size as per the existing IEC norms, floor mounted, IP 55 grade, outdoor type double door type LT cubical panel made out of 3mm thick CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032, dust and veremin proof with suitable size TPN PVC sleeved aluminium bus bar, incld. aluminium bus bars for incoming and outgoing connections supported on glass fiber reinforced thermosetting plastic insulated support with lifting lugs of suitable size. Panel should be mounted/grouted PCC (1:4:8) type D2 of size on as per the panel dimensions such that there should be 100 mm offsets complete. The bottom of the panel (space between bottom of panel and top of PCC foundation) shall be covered with 3 mm thick CRCA sheet covering all the sides of the base frame duly painted with two coats of synthetic enamel paint of approved shade over one coat of red oxide primer. The panel should have following accessories fitted in :- 1 Each Job
106 106 (i) MCCB 400 Amps ,415 V 4 pole 36 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make : Cat pat No : CM94106OOS1OG including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 01 No. - INCOMING
107 107 (ii) MCCB 250 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM90642OOPO including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 01 No. - OUTGOING
108 108 (iii) MCCB 200 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM90642OONO including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 02 Nos. - OUTGOING
109 109 (iv) LED indicators - R/Y/B 240 V AC - 12 Nos. - 03 Nos per Incoming and outgoing feeders.
110 110 (v) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as per L&T make, Cat No. - WL440010OOOO and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder)
111 111 (vi) Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL132010OOOO and including suitable size CTs (set of 3) - 03 Nos. (Outgoing feeders)
112 112 (vii) Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO and including suitable size CTs (set of 3) - 03 Nos. (Outgoing feeders)
113 113 (viii) MCB SP 'C' series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 11 Nos.
114 114 (ix) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc.
115 115 All as per SL Item No.50 above but panel with following components - 1 Each Job
116 116 (i) MCCB 250 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM90642OOPO including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 01 No. - INCOMING
117 117 (ii) MCCB 100 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM90642OOLO including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 03 Nos. - OUTGOING
118 118 (iii) MCCB 63 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM91712OOHOOG including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 01 No. - OUTGOING
119 119 (iv) LED indicators - R/Y/B 240 V AC - 15 Nos. - 03 Nos per Incoming and outgoing feeders.
120 120 (v) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as per L&T make, Cat No. - WL440010OOOO and including suitable size CTs (set of 3) - 01 No. (for Incoming)
121 121 (vi) Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL132010OOOO and including suitable size CTs (set of 3) - 04 Nos. (Outgoing feeders)
122 122 (vii) Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO and including suitable size CTs (set of 3) - 04 Nos. (Outgoing feeders)
123 123 (viii) MCB SP 'C' series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 14 Nos.
124 124 (ix) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc.
125 125 All as per SL Item No. 50. above but panel with following components - 1 Each Job
126 126 (i) MCCB 200 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM90642OONO including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 01 No. - INCOMING
127 127 (ii) MCCB 100 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM90642OOLO including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 02 Nos. - OUTGOING
128 128 (iii) MCCB 63 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM91712OOHOOG including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 02 Nos. - OUTGOING
129 129 (iv) LED indicators - R/Y/B 240 V AC - 15 Nos. - 03 Nos per Incoming and outgoing feeders.
130 130 (v) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as per L&T make, Cat No. - WL440010OOOO and including suitable size CTs (set of 3) - 01 No. (for Incoming)
131 131 (vi) Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL132010OOOO and including suitable size CTs (set of 3) - 04 Nos. (Outgoing feeders)
132 132 (vii) Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO and including suitable size CTs (set of 3) - 04 Nos. (Outgoing feeders)
133 133 (viii) MCB SP 'C' series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 14 Nos.
134 134 (ix) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc.
135 135 All as per SL Item No. 50 above but panel with following components - 1 Each Job
136 136 (i) MCCB 320 Amps ,415 V 4 pole 36 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make : Cat pat No : CM98403OOQOOG including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 01 No. - INCOMING
137 137 (ii) MCCB 250 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM90642OOPO including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 01 No. - OUTGOING
138 138 (iii) MCCB 63 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make ; Cat pat No : CM91712OOHOOG including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications and model or equivalent in legrand/ABB/Schenider - 02 Nos. - OUTGOING
139 139 (iv) LED indicators - R/Y/B 240 V AC - 12 Nos. - 03 Nos per Incoming and outgoing feeders.
140 140 (v) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours all as per L&T make, Cat No. - WL440010OOOO and including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder)
141 141 (vi) Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL132010OOOO and including suitable size CTs (set of 3) - 03 Nos. (Outgoing feeders)
142 142 (vii) Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as per L&T make, Cat No. - WL131010OOOO and including suitable size CTs (set of 3) - 03 Nos. (Outgoing feeders)
143 143 (viii) MCB SP 'C' series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 11 Nos.
144 144 (ix) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc.
145 145 Painting to electric control panel of E/M installations by cleaning the existing old paint with the help of mechanical tools such as wire brush, scraper and sand paper from the surface of panel and painting the prepared surface with two coat of synthatic enamel paint of approved shade over a coat of red oxide primer complete all as specified abd specified. 20 Sqm
146 146 Repairing/servicing of APFC panel board by replacing the all defective components with new components, re-wiring, cleaning, testing, reconnecting, re-installing and commissioning the APFC panel board complete all as specified and directed by Engr-in-Charge. 8 Each Job
147 147 S&F in replacement APFC relay of 8 stage supply Voltage 415 V AC and current Input - 1A or 5 A with specs as - 3 Phase Current and Voltage measurement, PF display - 3 Digit after decimal, Individual harmonics measurement up to 31st order, Dual PF setting for Mains - DG application, Communication through Inbuilt MODBUS RS-485 Protocol all as per L&T Cat Part No. CS91050OOOO or eqivalent in Epcos/Schenider/Seimens. 3 Each
148 148 Dismantling, supply and install, connect, test and commission of capacitor, 3 phase, Super Heavy Duty cylindrical type, self standing units, self healing property with MPP film with safety device in the form of pressure sensitive (over pressure) mechanical interrupter, 415/440V, 3 phase, 50 Hz, Capacity 5 KVAR, AC conformance to Standards IEC 60831-1 2/96, IS 13340 including testing, commisioning as in repairs complete all as specified and directed. 14 Each
149 149 All as per item no:52 above but 10 KVAR. 16 Each
150 150 All as per item no:52 but 20 KVAR. 16 Each
151 151 S&F in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts suitable for 10 kVAR capacitor complete with connected switch gear/ components in various APFC panels of L&T make Type MO C10 Cat Part No. CS96156 or equivalent in Makes as per PS of this CA all as specified and directed by Engr-in-Charge. 14 Each
152 152 S&F in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts suitable for 15 kVAR capacitor complete with connected switch gear/ components in various APFC panels of L&T make Type MO C15 Cat Part No. CS90019 or equivalent in Makes as per PS of this CA all as specified and directed by Engr-in-Charge. 15 Each
153 153 S&F in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts and Spreader Link Kit suitable for 25 kVAR capacitor complete with connected switch gear/ components in various APFC panels of L&T make Type MO C25 Cat Part No. CS96322 or equivalent in Makes as per PS of this CA all as specified and directed by Engr-in-Charge. 14 Each
154 154 S&F in repairs NO element complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge 14 Each
155 155 S&F in repairs NC element complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge 14 Each
156 156 S&F in repairs Illuminated push button- RED complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge 14 Each
157 157 S&F in repairs Illuminated push button- GREEN complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge 14 Each
158 158 S&F in repairs 1.1 KV current transformer of ratio 150/5 complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge 8 Each
159 159 S&F in repairs 1.5 Sqmm multistranded copper FRLSH wire for control circuit complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge 120 RM
160 160 S&F in repairs 6 sqmm multistranded FRLSH copper flexible cable complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge 120 RM
161 161 S&F in repairs 1.5 sqmm pin type lugs complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge 60 Each Job
162 162 S&F in repairs 6 sqmm pin/fork/round type lugsr complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge 60 Each Job
163 163 S&F in repairs 6-32 A SP MCB, 10 kA 'C' series, 240 V AC, 50 Hzcomplete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge 25 Each
164 164 S&F in repairs 32 A TP MCB, 10 kA 'C' series, 415 V AC, 50 Hz complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge 15 Each
165 165 S&F in repairs 63A TPN MCB, 10 kA 'C' series, 415 V AC, 50 Hz complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge 12 Each
166 166 S&F in repairs 2 way slector adaptor 25 Amps complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge 10 Each
167 167 Taking down old unsv fitting and supply and fix LED flood light fitting 90 watts, IP65 class with separate integral driver and with pressure dia-cast aluminium housing all as per Crompton Make, Cat Pat No LFLN-90-CDL or eq in Havells/Bajaj/HPL. NOTE - The quoted rate is deemed to be inclusive of cost of minor spares and misc jobs to be carried at site for fittment of luminarie. 8 Each
168 168 S&F LED LUMINARIE, pressure die cast aluminum housing, 45 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete all as directed and specified by Engr-in-charge. MAKE of make Crompton Greaves cat part no - LSTP-45-CDL or Equivalent in Makes as mentioned in PS of thsi tender. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 29 Each
169 169 Supply only street/security light bracket made out of 40mm dia light grade 1.5mtr bent to shape for fixing on any type of pole/wall with clamps nuts and bolts complete all as directed by engr-in-Charge. Make of GI pipe shall be Jindal/TATA/Swastik. Note:Cost of necessary GI items such as reduce ,coupler ,etc required to be fitted with GI bracket so as toproper fitiment of luminaries with bracket is deemed to be included in the quoted rate. 60 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail