| 1 | 1 | SCHEDULE 'A' | | | |
|---|
| 2 | 2 | Excavating in trenches n.exc. 1.5m wide and n.exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n.exc. 10 sqm on plan and n.exc 1.5m in depth and getting out in hard/dense soil,complete all as specified and directed. | | 47 | Cum |
|---|
| 3 | 3 | All as per item No. 2 above but to a depth beyond the first 1.5m complete all as specified. | | 0.5 | Cum |
|---|
| 4 | 4 | Excavation in post hole (or similar holes) each n.exc 0.5 cum and getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm watering and removing surplus soil to a distance n.exc 50 m and making good in hard/dense soil complete all as specified and directed. | | 36 | Each |
|---|
| 5 | 5 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. | | 512 | Sqm |
|---|
| 6 | 6 | Dismanling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. | | 67 | Qtl |
|---|
| 7 | 7 | Demolition of cement concrete in ground floors and pavings n exc15 cm thickness (below or above ground level, un reinforced)complete all as specified and directed. | | 25 | Cum |
|---|
| 8 | 8 | S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed. | | 3815 | Kg |
|---|
| 9 | 9 | All as per item No. 8 above but fabrication and erection only complete all as specified and directed. | | 1430 | Kg |
|---|
| 10 | 10 | M & L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation bed concrete complete all as specified and directed. | | 16.3 | Cum |
|---|
| 11 | 11 | Returning and filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil etc complete all as specified and directed. | | 8.4 | Cum |
|---|
| 12 | 12 | Removal of excavated soil to a distance not exceeding 50m and despositing where directed complete all as specified and directed. | | 47.1 | Cum |
|---|
| 13 | 13 | M & L Pre painted galvalume aluminium zinc coating GI based corrugated steel 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed. | | 263 | Sqm |
|---|
| 14 | 14 | All as per item No. 13 above but except sheeting complete all as specified and directed. | | 174 | Sqm |
|---|
| 15 | 15 | S/F prepainted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick having tensile strength 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed. | | 75 | Sqm |
|---|
| 16 | 16 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. | | 340 | Sqm |
|---|
| 17 | 17 | M & L for preparation of new or previously untreated steel surfaces of any description over 10 cm in width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. | | 155 | Sqm |
|---|
| 18 | 18 | M& L for complete removal of existing treatment and preparation steel surfaces of any description over 10 cm in width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. | | 100 | Sqm |
|---|
| 19 | 19 | M&L Hardcore using broken stones or boulders of gauge n exc 63 mm, deposited, spread & levelled in layers n exc 15 cm thick, watered & rammed to a true surface complete all as specified and directed. | | 5 | cum |
|---|
| 20 | 20 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. | | 105 | Sqm |
|---|
| 21 | 21 | M & L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in floor 100 mm thick complete all as specified and directed. | | 53 | Sqm |
|---|
| 22 | 22 | M &L 40 mm thick Plain cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregate as in floor including necessary form work, finishing even and smooth without using extra cement complete all as specified and directed. | | 345 | Sqm |
|---|
| 23 | 23 | M &L 25 mm thick Plain cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregate as in sub base including necessary form work.complete all as specified and directed. | | 225 | Sqm |
|---|
| 24 | 24 | M&L for 15 mm thick screed bed or bedding layer of cement mortar 1:6, for laying floor finishes complete all as specified and directed. | | 225 | Sqm |
|---|
| 25 | 25 | M/L for 10 mm thick plastering in cement mortar 1:4 as backing coat for receiving finishes as skirting /dado complete all as specified and directed by Engineer in charge. | | 105 | Sqm |
|---|
| 26 | 26 | S & F joint free matt finish coloured Non skid ceramic tiles 7 to 8 mm thk (square /Rectangular ) area of each tile exc 0.18 sqm and n.exc 0.38 sqm ,in floors etc set and jointed in neat cement slurry and pointed with white cement or pigment to match with the shade of the tiles all as specified and as directed. | | 225 | Sqm |
|---|
| 27 | 27 | M & L dark shade Vitrified ceramic tiles 10mm thick (square/rectangular) area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. | | 90 | Sqm |
|---|
| 28 | 28 | M & L Digital type finger engraved Glazed ceramic tiles in vertical surface , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. | | 15 | Sqm |
|---|
| 29 | 29 | Demolition of brickwork or stone boulder built in cement mortar including all quoins, arches,pillers,etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed. | | 6 | Cum |
|---|
| 30 | 30 | M & L Pre cast cement concrete block masonry with solid blocks, exc 10 cm in width and setting in CM 1:6 type C1 1:3:6 using 20 mm grade stone agg all as specified and directed. | | 16 | Cum |
|---|
| 31 | 31 | M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate in benching, coping complete all as specified and directed. | | 2.3 | Cum |
|---|
| 32 | 32 | M&L for rendering 15 mm thick in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed. | | 340 | Sqm |
|---|
| 33 | 33 | M&L two coat of exterior emulsion weather coat paint over the new plasterd wall surface including preparation of surfaces and one coat of primer complete all as specified and directed. | | 236 | Sqm |
|---|
| 34 | 34 | M & L for complete removal of old plastered surfaces of wall and two coat of exterior emulsion weather coat paint over the new plasterd wall surface including preparation of surfaces and one coat of primer complete all as specified and directed. | | 200 | Sqm |
|---|
| 35 | 35 | Extra for forming fair finished to drain or channel 30 cm inner girth in cement including forms, mould mitred/stopped ends etc.complete all as specified and directed. | | 115 | RM |
|---|
| 36 | 36 | M&L, for PCC 1:3:6 type C-2 using 40mm grade stone aggregate as in surface channels and drains complete all as specified and directed. | | 1.5 | Cum |
|---|
| 37 | 37 | Supply only chain link MS galavnised fencing as specified. | | 740 | Kg |
|---|
| 38 | 38 | Fixing only chain link fencing including line wires, and mesh size type of standards, rail straining bols etc size of mess 100x100mm 4mm dia wire complete all as specified and directed. | | 252 | Sqm |
|---|
| 39 | 39 | M&L for mild steel round bars 10mm dia and over cut to length bent to s hape required and fixing as required in fencing complete all as specified and directed. | | 296 | Kg |
|---|
| 40 | 40 | M&L Mild steel flat iron as in post in fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe 290 (Gde E-165) complete all as specified and directed. | | 355 | Kg |
|---|
| 41 | 41 | S&F 12mm dia. MS bolts machine made with hexagonal or square head one end screwed the other or screwed both end n exc 5 cm long complete all as specified and directed | | 38 | Kg |
|---|
| 42 | 42 | M&L for preparation of new or previously untreated steel surfaces of any description, n. exc. 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide/zinc chrome primer unconnected with other painting or painted in a different tintr all as specified and directed by Engineer-in-Charge. | | 67 | 10RM |
|---|
| 43 | 43 | Taking down copper/aluminum point wiring (Light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendent, regulators, sockets etc removing serviceable materials to store for keeping in safe custody or taking credit (credit for above items should be made as per conditions separately ) and making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces complete all as specified and directed by Engineer-in-Charge. | | 14 | Point |
|---|
| 44 | 44 | M&L for point wiring complete with 1.5 Sqmm 1100 V grade single core FRLSH PVC insulated unsheathed cable with multi stranded copper conductor ISI marked drawn through concealed PVC conduit ISI marked of suitable size on walls/ceilings etc and including provn of 1.5 Sqmm PVC insulated copper cable as earth continuity conductor connected to common earth dolly including 1.2mm thick pressed steel terminal boxes of suitable size with 3mm thick laminated sheet cover for (i) One light point controlled by one switch. for mounting switches and sockets all as specified and directed . Note:- Rate for cutting of chases for fixing of PVC conduits and its accessories including making good the disturbed surfaces of walls/ floors etc with the existing deemed to be included in the item rate | | 8 | Point |
|---|
| 45 | 45 | (ii) All as per Item No.44 above but for One switch socket outlet 5 Amps on independent board complete all as specified and directed by Engineer-in-Charge. | | 4 | Point |
|---|
| 46 | 46 | All as per Item No 44 here-in- before but with 2.5 Sqmm PVC insulated FRLS multistranded copper conductor with 2.5 sqmm cable as earth continuity conductor for one 3 pin socket outlet 16 Amps concealed in wall / ceiling complete all as specified and directed by Engineer-in-Charge. | | 2 | Point |
|---|
| 47 | 47 | S&F switch piano, flush type 240 Volts, 5 Amps, single pole, one way ISI marked complete all as specified and directed by Engineer-in-Charge.. | | 8 | Each |
|---|
| 48 | 48 | Supply and fix switch socket combination 2 in 1, 5 pin 5A flush type 240 volts complete all as specified and directed by Engineer-in-Charge. | | 4 | Each |
|---|
| 49 | 49 | Supply and fix switch socket combination multipurpose 3 pin, 5/15A, flush type 240 volts complete all as specified and directed by Engineer-in-Charge. | | 2 | Each |
|---|
| 50 | 50 | S&F in replacement of UNSV tube light fitting with 36/40 Watt with surface nad wall mounted rail of 20W LED battern with integrated electronic driver and bracket including 20 Watt LED tube complete vwith accessories internally prewired coonecting up with twin core flexible copper conductor cable of suitable size complete all as specified and as directed. | | 8 | Each |
|---|
| 51 | 51 | M&L for ceiling rose surfaces bakelite of size 65x50 mm, 2 to 3 terminals,230 volts complete all as specified and directed by Engineer-in-Charge.. | | 8 | Each |
|---|
| 52 | 52 | Taking down u/s MCB DB , S&F TPN 4 way of any size and capacity double door with suitable bus bar including disconnecting from mains and making good disturbed surfaces as directed by Engineer-in-Charge. | | 1 | Each |
|---|
| 53 | 53 | Supply and fix only the MCB TPN 40A ,230V,50Hz,AC with rupturing capacity 10kA all as specified and as directed. | | 1 | Each |
|---|
| 54 | 54 | Supply and fix only the MCB SP 6-32A ,230V,50Hz,AC with rupturing capacity 10kA all as specified and as directed. | | 6 | Each |
|---|
| 55 | 55 | Supply and fix only the MCB SPN 40A ,230V,50Hz,AC with rupturing capacity 10kA all as specified and as directed. | | 2 | Each |
|---|
| 56 | 57 | Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out complete all as specified. | | 60 | Cum |
|---|
| 57 | 58 | Returning and refilling of excavated soil up to a depth of 30 cm after riddling the excavated soil for Cushoning of cable and refilling of trench with normal excavated soil all as specified and directed. | | 52 | Cum |
|---|
| 58 | 59 | M&L for Protection to cable with one layer of new bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks all as specified and directed.. | | 2 | 1000 bricks |
|---|
| 59 | 60 | M&L for prestressed concrete pole, 9 m long, 102 mm x172 mm at top and 102 mm x 279 mm at bottom, class 10 all as specified and directed...\nNote:- Excavation and earth work and concrete in foundation and pedestal shall be measured and paid for separately.\n | | 4 | Each |
|---|
| 60 | 61 | M/L for PCC 1:3:6 Type C1 with 20 mm graded aggregate for coping of pole complete including necessary form work all as specified and directed.. | | 1 | Cum |
|---|
| 61 | 62 | Supply, lay, test and commissioing of LT UG cable XLPE multi stranded armoured cable of size 2 core 10 Sqmm with aluminium conductor for working voltage upto and including 1100 volts grade, in trenches/duct/ on walls/on poles etc incl. necessary MS clamps, cable glands, lugs etc for fixing and connecting the cable all as specified and directed.. | | 300 | RM |
|---|
| 62 | 63 | M&L for Fabrication and fixing of street light bracket made of MS Channel 50 mm dia of length 1.2 mtr to fix in top of pole with nuts and suitable clamps incl two run of 2.5 Sqmm PVC insulated sheathed copper conductor cable from terminal box to street light fittings drawn through Steel tubular pole. | | 4 | Each Job |
|---|
| 63 | 64 | Supply and fix energy saving environment friendly , long life, exclusive innovative die-cast aluminium flood light with highly efficient LEDs as light source of capacity 200W all as specified. | | 10 | Each |
|---|
| 64 | 65 | S & F hot press moulded SMC junction / terminal box of size with internal dimensions of 200 x 140 x 95 mm with hinged door, incl provision of 4 way connector 415 Volts made out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or outgoing cables by providing suitable size of cable lugs/glands, fixed on pole by means of clamps. | | 4 | Nos |
|---|
| 65 | 66 | Total of Schedule 'A' | | | |
|---|