Military Engineer Services-MES has published Repair To Refrigerator , Windows/ Split Ac , Water Cooler , Desert Cooler , Voltage Stabilizer And Deep Freezer At Mil Stn Shahjahanpur Under Ge ( East ) Bareilly. Submission Date for this Tender is 26-10-2020. Voltage Stabiliser Tenders in SHAHJAHANPUR Uttar Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: REPAIR TO REFRIGERATOR, WINDOWS/ SPLIT AC, WATER COOLER, DESERT COOLER, VOLTAGE STABILIZER & DEEP FREEZER AT MIL STN SHAHJAHANPUR UNDER GE (EAST) BAREILLY | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down ceiling/exhaust fan from the site of any size complete all as specified and directed. | 948 | Each | |
2 | 2 | Fixing only exhaust fan of any size including provn of cable for connection complete all as specified and directed. | 100 | Each | |
3 | 3 | Fixing only ceiling fan of any size including provn of cable for connection complete all as specified and directed. | 848 | Each | |
4 | 4 | M&L for painting of ceiling fans in situ with one coat of synthetic enamel paint by spraying including after cleaning of dust etc filling cavities with filler complete all as specified and directed. | 848 | Each | |
5 | 5 | M&L for collecting unserviceable ceiling fans 48" (1200 mm) sweep 230 V, AC sup, Single phase from site of AGE B/R Shahjahanpur, dismantling the ceiling fan and taking out complete burnt winding from fan motor and rewinding the same with super enameled copper winding wire of existing gauge and size including throughly cleaning all the components of the fan, oiling and greasing the fan with and including replacement of rusted/unserviceable nuts, bolts, split pin, rubber reel, machine screws etc including replacement of defective/ unserviceable parts spares as required re-assembling, including transportation the fan and including testing complete all as specified and directed. | 720 | Each Job | |
6 | 6 | All as per item No 5 here-in-above but ceiling fan size 56"(1400 mm sweep) complete all as specified and directed. | 128 | Each Job | |
7 | 7 | M&L for collecting unserviceable exhaust fans 18" (450 mm) sweep 230 V, AC sup, Single phase from E/M store yard of of AGE B/R Shahjahanpur, dismantling the exhaust fan and taking out complete burnt winding from exhaust fan motor and rewinding the same with super enameled copper winding wire of existing gauge and size including throughly cleaning all the components of exhaust fan, oiling and greasing painting with one coat of synthetic enamel paint after scrubbing and preparing the old painted surfaces, replacement of rubber pipes and depositing the exhaust fan of E/M store yard of AGE B/R Shahjahanpur including transporting and testing etc complete all as specified and directed. | 25 | Each Job | |
8 | 8 | Ditto as per item ser No 7 above but 250/300 mm sweep complete all as specified and directed. | 75 | Each Job | |
9 | 9 | S&F capacitor Dry type 2.5 MFD 230 volts for ceiling fan of any type complete all as specified and directed. | 1500 | Each | |
10 | 10 | S&F capacitor Dry type 3.15 MFD 230 volts for ceiling fan of any type complete all as specified and directed. | 500 | Each | |
11 | 11 | S&F capacitor Dry type 4 MFD 230 volts for ceiling fan of any type complete all as specified and directed. | 50 | Each | |
12 | 12 | S&F cord flexible, PVC twin core copper conductor cable of size 23/0.0076 complete all as specified and directed. (Make Finolex/Nicco) | 848 | RM | |
13 | 13 | S&F fan down rod suitable for ceiling fan including clamps heavy duty as required in replacement complete all as specified and directed. | 200 | Each | |
14 | 14 | S&F in replacement taking out the old unserviceable sealed compressor unit from existing window type AC 1.5 ton capacity of any make by cutting and replacing the same with new sealed unit from authorised OEM workshop/manufacturer and reconnecting the relaced sealed compressor unit to its original position of air conditioner by brazing including flushing out complete refrigerator system by applying CTC/nitrogen gas, charging the refrigeration system with and including compressor oil and refrigerant R-134 gas to its full capacity after complete equating and cleaning the system reinstalling the air conditioner at site and testing on false load to its satisfactory performance complete all as specified and directed. | 4 | Each Job | |
15 | 15 | All as per item No 14 here-in-before but for capacity of air condition (2.00 ton) complete all as specified and directed. | 2 | Each Job | |
16 | 16 | Flushing the complete refrigeration system and repairing of leakage pipe lines by brazing and charging the unit by compressor oil and refrigerant Gas-134 to its full capacity after evacuating and cleaning the complete system and installing, commissioning and testing for its smooth functioning for 72 hours on full load complete all as specified and directed. | 3 | Each Job | |
17 | 17 | S&F in repair for over load protector suitable for AC protector complete all as specified and directed. | 5 | Each | |
18 | 18 | S&F in repair relay suitable for 1.5 Ton (window/Split type) air conditioner complete all as specified and directed. | 3 | Each Job | |
19 | 19 | S&F in repair thermostat switch for AC complete all as specified and directed. | 5 | Each | |
20 | 20 | S&F in repair switch controlling knobs along with complete control panel for any make and any size of AC complete all as specified and directed. | 5 | Each | |
21 | 21 | S&F in repair running capacitor of required 36/45 MFD complete all as specified and directed. | 5 | Each | |
22 | 22 | S&F in repair starting capacitor of required 120 MFD complete all as specified and directed. | 6 | Each | |
23 | 23 | M&L for repairing of voltage stabilizer of any make and size of 4 KVA to 5 KVA by repairing/ replacement of electric circuit and rewinding including insulating materials complete all as specified and directed. | 7 | Each | |
24 | 24 | S&F in repair of PCB sutable size for window / split AC complete all as specified and directed. | 6 | Each | |
25 | 25 | Taking of old unserviceable/sealed compressor unit from existing refrigerator of 310/300 ltrs capacity of any make by cutting replacing the same from authorized OEM workshop and re-connecting the sealed compressor unit to its original position of refrigerator by brazing including flushing out complete refrigeration system by applying/using Nitrogen gas, charging the refrigeration system with and including compressor oil and refrigerant R-134 gas to its full capacity reinstalling the refrigeration machine at site testing on full for its satisfactorily performance including painting to complete body of refrigerator with two coats of synthetic enamel paint after preparation of dents complete all as specified and directed. | 6 | Each Job | |
26 | 26 | All as per item No 25 here-in-before but for capacity of refrigerator 280 ltrs complete all as specified and directed. | 5 | Each | |
27 | 27 | All as per item No 25 here-in-before but for capacity of refrigerator 165/175 ltrs complete all as specified and directed. | 4 | Each | |
28 | 28 | Flushing out complete refrigeration system by nitrogen/CTC gas after deleting leakage and repairing tube/lines by brazing and charging the unit with compressor oil and refrigerant Gas-134 to its full capacity of refrigerator 300 lts capacity of any make including commissioning and testing for its smooth functioning complete all as specified and directed. | 8 | Each | |
29 | 29 | S&F rubber gasket of refrigerator door of any size and any make complete all as specified and directed. | 8 | Each | |
30 | 30 | Supply and replacement of thermostat switch of suitable size for any make and size of refrigerator complete all as specified and directed. | 7 | Each | |
31 | 31 | S&F in repair for running capacitor of suitable size of refrigerator of any make and size complete all as specified and directed. | 12 | Each | |
32 | 32 | S&F in repair for starting capacitor 40 MFD capacity complete all as specified and directed. | 9 | Each | |
33 | 33 | S&F in repair for relay assembly suitable for refrigerator starting capacitor 40 MFD capacity complete all as specified and directed. | 11 | Each | |
34 | 34 | S&F in repair for over load protector suitable for refrigerator protector complete all as specified and directed. | 8 | Each | |
35 | 35 | Supply and replacement of freezer door of any make 310/300/286 ltrs size of refrigerators complete all as specified and directed. | 5 | Each | |
36 | 36 | All as per item No 35 here-in-before but size of refrigerator 165/175 ltrs complete all as specified and directed. | 5 | Each | |
37 | 37 | Repair to body of refrigerator of any size/capacity by welding of MS Sheet not less than 1.6 mm thick to match existing after receiving old rusted/unserviceable portion replacement of old nut bolt washers and hinges of top cover including painting to complete body of refrigerator with two coat of synthetic enameled paint after preparation of surface and removing dents complete all as specified and directed. | 5 | Each Job | |
38 | 38 | Taking of old unserviceable/sealed compressor unit from existing deep freezer of 300/310 ltrs capacity of any make by cutting replacing the same from authorized OEM workshop and re-connecting the sealed compressor unit to its original position of refrigerator by brazing including flushing out complete refrigeration system by applying/using Nitrogen gas, charging the refrigeration system with and including compressor oil and refrigerant R-134 gas to its full capacity reinstalling the refrigeration machine at site testing on full for its satisfactorily performance including painting to complete body of refrigerator with two coats of synthetic enamel paint after preparation of dents complete all as specified and directed. | 4 | Each Job | |
39 | 39 | Taking out the broken legs from the base of refrigerator supplying and fixing new legs set of 4 to put the refrigerator of any capacity/make in to vertical position complete all as specified and directed. | 8 | Each | |
40 | 40 | M&L for repairing of voltage stabilizer of any make and size of 2 KVA to 3 KVA by repairing/replacement of electric circuit and rewinding including insulating materials complete all as specified and directed. | 20 | Each | |
41 | 41 | Taking out the old unserviceable sealed compressor from existing water cooler of any capacity of any make 120/60 ltrs storage capacity by cutting, replacing the same with new compressor from manufacturer and re-connecting the replaced sealed compressor, unit to its original position of water cooler by brazing including flushing out complete refrigeration system by applying/using CTC Nitrogen gas, charging the refrigeration system with and including compressor oil and refrigerant R-134 gas to its full capacity after complete evacuating and cleaning the system reinstalling the water cooler at site and testing on full for its satisfactorily performance complete all as specified and directed. | 8 | Each Job | |
42 | 42 | All as per item No 41 here-in-before but for capacity of water cooler 40/40 ltrs complete all as specified and directed. | 6 | Each Job | |
43 | 43 | Flushing out complete refrigeration system by CTC and repairing the leaking pipe/ joints by refrigeration brazing and charging the unit with compressor oil and refrigerant gas after evacuating and flushing to its full capacity of any size and make of water cooler complete all as specified and directed. | 7 | Each Job | |
44 | 44 | S&F in repair for running capacitor of suitable size of water cooler of any make and size complete all as specified and directed. | 7 | Each | |
45 | 45 | S&F in repair for starting capacitor 80/100/120 MFD capacity complete all as specified and directed. | 9 | Each | |
46 | 46 | S&F in repair for relay assembly 412Y/312Y complete all as specified and directed | 9 | Each | |
47 | 47 | S&F in repair for over load protector suitable for water cooler protector complete all as specified and directed. | 7 | Each | |
48 | 48 | S&F in repair for thermostat for water cooler complete all as specified and directed. | 7 | Each | |
49 | 49 | S&F in repair rubber bedding gasket for any make and size of water cooler tank cover upto 25mm bore complete all as specified and directed. | 9 | Each | |
50 | 50 | Repair to body of water cooler of any size/capacity by welding of MS sheet not less than 1.6mm thick to match existing after receiving old rusted/unserviceable portion, replacement of old nut bolt washers and hinges of top cover including painting to complete body of W/C with two coat of synthetic enameled paint after preparation of surface and removing dents complete all as specified and directed. | 8 | Each Job | |
51 | 51 | S&F in replacement of PVC copper cable 2.5 sqmm multistrand three core complete all as specified and directed. | 300 | RM | |
52 | 52 | M&L for repairing of voltage stabilizer of any make and size of 0.5 KVA to 1 KVA by repairing/replacement of electric circuit and re-winding including insulating materials complete all as specified and directed. | 15 | Each | |
53 | 53 | M&L for complete overhauling of desert cooler of any size and make including replacement of perished wiring oiling and greasing the blower motor exhaust fan and water lifting/tullu pump including replacement of plastic unserviceable spares such as ben, water distributor and PVC pipe including replacement of wood pads, preventing leakage if any by welding, painting of water tank with rubber seal of any approved make and testing the same for its smooth functioning complete all as specified and directed. | 55 | Each Job | |
54 | 54 | M&L for two coats of painting for desert cooler cover a coat of red oxide primer including preparation of old surfaces on complete body of desert cooler of existing colour after removing dents and preparing surface complete all as specified and directed. | 55 | Each | |
55 | 55 | S&F in replacement of water lifting/tullu pump submersible type complete all as specified and directed. | 60 | Each | |
56 | 56 | Taking down the Geyser of capacity 25 / 50 Ltr including disconnecting of electric / water supply connections from building for repair / replacement of defective components and overhauling / checking, servicing , des calling of inner tank , geyser element, checking of geyser assembly and setting of thermostat range complete and refixing the same after repair and testing including making electric and water supply connection complete all as specified and directed by Engineer-in-charge. Note:- a) All safety precautions for the safety precautions for persons working during removal/fixing back of the Geyser shall be ensured by the contractor . Rates are inclusive of brazing of inner tank of copper for prevention of leakage and replacement of clamps nut bolts gasket set complete . b) replacement of defective components, painting, etc., which shall be measured and paid for separately. | 325 | Each | |
57 | 57 | S&F Heating element of capacity 2 kW (cap type / triangular / threaded type), ISI marked, suitable for geyser of capacity 50Ltr complete all as specified and directed. | 150 | Each | |
58 | 58 | S&F Heating element of capacity 1.50 KW (cup type), ISI marked, suitable for geyser of capacity 25Ltr complete all as specified and directed. | 175 | Each | |
59 | 59 | S&F replacement of neon Indicator lamp of red and green colour lamps suitable for geyser of capacity 25/ 50 Ltr of any type / make complete all as specified and directed. | 50 | Each | |
60 | 60 | S&F in replacement of Thermostat assembly 16 A,240 AC, ISI marked, suitable for geyser of capacity 25/ 50Ltr of any type / make complete all as specified and directed. | 150 | Each | |
61 | 61 | S&F in replacement of PVC Helical (Hot / Cold) water connection pipe of size 450 mm x 15mm dia with two nos of brass nut on each side for geyser complete all as specified and directed. | 50 | Each | |
62 | 62 | S&F in replacement of bottom plate of geyser in two pieces including painting of approved colour suitable for 25/50 ltr capacity geyser as per original pattern and as approved by GE complete all as specified and directed. | 30 | Each Set | |
63 | 63 | S&F of (4 nos) ,16 mm dia nuts bolts of suitable length duly grouted in walls in cement mortar for fixing of geyser of any capacity complete all as specified and directed. | 50 | Each Set | |
64 | 64 | Taking out damage glass wool from the geyser and supply fix glass wool all around the inner tank of geyser for maintaining the required temperature complete all as specified and directed. | 25 | Each Set | |
65 | 65 | S&F in replacement of Gun metal Non return valve (NRV) of size 15 mm bore ISI marked complete all as specified and directed. | 20 | Each | |
66 | 66 | S&F in replacement of stop valve fancy type cromium plate high pressure surface concealed with crutch of butter fly handle screwed both ends for iron pipe 15 mm bore ISI marked complete all as specified and directed. | 20 | Each | |
67 | 67 | S&F in replacement of inner tank stainless steel of capacity 25 ltr geyser complete all as specified and directed. | 7 | Each | |
68 | 68 | S&F in replacement of inner tank stainless steel of capacity 35 ltr geyser complete all as specified and directed. | 5 | Each | |
69 | 69 | S&F in replacement of MS clamp (set of two nos) with nut, bolts and washer, rubber reel, safety pin, complete all as specified and directed. | 30 | Each Job | |
70 | 70 | Supply and replacement of PVC connection heavy duty nylon thread reinforcement 16mm dia 450mm long both end brass nipple with washer for outlet/inlet connection of any capacity/make of vertical type geysers complete all as specified and directed. | 120 | Each | |
71 | 71 | Supply and replacement of PVC connection heavy duty nylon thread reinforcement 16mm 600 mm long both end brass nipple with washer for outlet/inlet connection of any capacity/make of vertical type geysers complete all as specified and directed. | 100 | Each | |
72 | 72 | S&F wall steel fastener (4 Nos) nut bolt and washers of size 8mmx75mm long complete all as specified and as directed. | 20 | Each | |
73 | 73 | S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed. | 20 | Each | |
74 | 74 | M&L for two single core PVC Insulated unsheathed multi stranded FRLS copper conductor cable of size 4 sqmm as sub main wiring including suitable size heavy duty rigid PVC conduit and of PVC insulated unsheathed multi stranded FRLS copper conductor cable of size 4 sqmm as an earth continuity conductor complete all as specified. | 273 | RM | |
75 | 75 | M&L for two single core PVC Insulated unsheathed multi stranded FRLS copper conductor cable of size 2.5 sqmm as sub main wiring including suitable size heavy duty rigid PVC conduit and of PVC insulated unsheathed multi stranded FRLS copper conductor cable of size 2.5 sqmm as an earth continuity conductor complete all as specified. | 300 | RM | |
76 | 76 | Note : Tenderers may note that amount of credit Rs 62,604.00 will be deducted from the total amount arrived, at the time of Acceptance of contract. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail