Certain Repair To Runway , Taxiway And Hanger Lights And Other Misc Items Under Ge ( S ) Mamun .

Tender Notice

25720052
Certain Repair To Runway , Taxiway And Hanger Lights And Other Misc Items Under Ge ( S ) Mamun .
Indian
Punjab
14-10-2020
02-11-2020
04-11-2020

Tender Details

Certain Repair To Runway , Taxiway And Hanger Lights And Other Misc Items Under Ge ( S ) Mamun .

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.00 /-
Tender Value
Refer document

BOQ Items

Name of Work: CERTAIN REPAIR TO RUNWAY, TAXIWAY AND HANGER LIGHTS AND OTHER MISC ITEMS UNDER GE (S) MAMUN
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavating in trenches in any type of soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out. 202.5 CUM
2 2 Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm. 95 CUM
3 3 Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point. 107.5 CUM
4 4 Supply and lay in replacement in trenches/on wall/on pole/in duct /through protection pipe, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables heavy duty LT cable, 1100 volts grade with aluminium conductor cross sectional area 35 Sqmm 3.5 core size. \n\n 270 RM
5 5 All as per item No. 4 above but 50 sqmm 3.5 core\n 300 RM
6 6 All as per item No. 4 above but 70 sqmm 3.5 core\n 240 RM
7 7 All as per item No. 4 above but 95 sqmm 3.5 core\n 350 RM
8 8 All as per item No. 4 above but 10 sqmm 2 core\n\nNote for item No. 4 to 8 :- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately. 320 RM
9 9 M&L for dry clean fine river sand as in sand cushioning to underground cable including punning down of sand layer all as specified and directed. \nNote :- Punned thickness shall only be measured and paid. 81 CUM
10 10 M&L for brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed. 8000 EACH
11 11 Supplying, jointing and connecting "in replacement" cable end termination joint kit, out door/indoor, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 95 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed. \n 2 EACH
12 12 M&L for in replacement galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings including clamp 02 Nos of size 25mm x 4mm, nuts, bolts and washers etc, complete, of size 50 mm bore. 22 RM
13 13 M&L for in replacement galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings including clamp 02 Nos of size 25mm x 4mm, nuts, bolts and washers etc, complete, of size 100 mm bore. 37 RM
14 14 S & F in replacement MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA, complete all as specified and directed. \n 5 EACH
15 15 Description all as per srl item No 14 here-in-before but 200 Amps complete all as specified and directed. \n 4 EACH
16 16 Description all as per srl item No 14 here-in-before but 250 Amps complete all as specified and directed. \n 4 EACH
17 17 Description all as per srl item No 14 here-in-before but 350 Amps complete all as specified and directed. \n 2 EACH
18 18 Description all as per srl item No 14 here-in-before but 400 Amps complete all as specified and directed. \n 2 EACH
19 19 Supply and fixing as in repair/replacement of pole mounted street light factory fabricated junction box of size 300 x 160 x 250 mm of approved make and of appropriate size made out of 2 mm thick CRCA powder coated sheet , including63A ,Three Phase four wire having four no.AL Bus Bar including 6A SP MCB. The box should have auto Door Lock facility with magnetic Lock having Sizehaving Size box fixed on pole using necerssary fixing arrangement such as clamps, nut, bolts and washer including taking down existing junction box of any description/type etc complete all as specified and directed. 15 EACH
20 20 Supply, installation, connecting electrically and testing of street light panel box complete in replacement with Astronomical timer ,contactor rating 65 Amp, MCB 63 A TPN complete for mounted made out of CRCA sheet 1.6 mm thick, powder coated, having provision for Astronomical Timer, Contactor, Toggle switch, SP MCBs and MCCBs etc. having self closing door lock complete with fixing clamps or mounting arrangement all as required at site, specified or directed including taking out existing U/S street light switch any type and size complete all as specified and directed. 2 EACH
21 21 M&L for repairing, servicing and replacement of LT panels unserviceable part including complete broken accessories such as partialy open door, broken door, unserviceable aluminium bus bar, unserviceable/ broken locking arrangement, repairing of LT Panel legs, welding work, neceassry PCC work, excavtaion and earth work including disconnection and reconnection of cables with suitable size of Al Lugs in proper engineering practice, for any size of cables in any capacity LT Panel also Fixing of LT Danger Notice Plate both side of the panel, complete all as specified and directed. Note :- Only Danger Notice plate shall be measured and paid seperately. 20 EACH JOB
22 22 M&L for painting of LT panel after removing old dust particles, oily portion by rubbing with sand paper and painting a coat of synthetic enamel paint with spray pump, and writing/digital printing, Capacity Descripton, date of installation,etc complete all as specified and directed. 20 EACH JOB
23 23 M&L for Scraping of old paint from the steel tubular pole 9 mtr height with out removing accessories and preparation of surfaces for repainting. Repainting the pole with one coat of 30 cm alternative green and white strips of each upto 1.5 mtr height using synthetic enamel paint. Repainting the remaining pole and iron parts i.e. U clamps, channels etc above 1.5 mtr height by applying Two coat of aluminium paint, including writing letters or figures (Block, Roman, Italic or Indian) S/L Pole No. and Location code not exceeding 30 cm high, stop, commas, short lines, dashes, hypens, brackets etc. complete all as specified and directed. 30 EACH JOB
24 24 M&L for painting of PCC pole 11 Mtr height without removing accessories with two coats of alternative green and white strips of 30cm each upto 1.5 Mtr height using synthetic enamell paint . marking the pole number with black synthetic enamel paint over yellow circle of dia 100mm. Painting the steel parts i.e clamps, channels etc by applying two coats of alumn paint all as required at site, complete all as specified and directed. 54 EACH JOB
25 25 M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including earth lead of galvanized strip 25x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of strata, PCC 1:3:6 type C1 in chamber, precast RCC cover 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe up to 7.5m. \nNOTE: Item includes the cost of earth lead and GI protection pipe up to 7.5m. GI strip beyond 7.5m shall be measured and paid for separately. 2 EACH
26 26 Taking down street light fitting or flood light fitting of any type and rating from poles, walls or any other indicated situation / location including removal of GI bracket pipe as directed, after disconnecting electrically. seggregating serviceable and unservicable fittings. Keeping aside serviceable for re-use at same location or any other location with in the zone and removing unserviceable from site, complete all as specified and directed. \n 23 EACH
27 27 Supply, fixing and testing of 60W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete available CCT 5700K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance. LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed. 21 EACH
28 28 Supply, fixing and testing of 150W LED Flood Light luminaire. LED Flood Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete available CCT 5700K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Flood light should be top maintainable for easy maintenance. LED Flood Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Flood Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Flood Light shall have power factor more than 0.95 complete all as specified and directed. 7 EACH
29 28.01 Note for srl item No 27 & 28 \n1. Driver shall be potted anti-vibration types. \n2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be provided. \n3. CRI (Colour Rendering Index) of fixture shall be > 70.\n4. CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. \n5. System Lumen Efficacy shall be > 100 Lm/W.\n6. 10 KV separate Surge Protection shall be provided as a part of fitting. \n7. 5 years guarantee shall be provided by contractor supported by OEM covering all parts of luminaire. \n8. Lenses shall be Modular Type. \n9. PCB used shall be MC PCB type. \n10. The defect liability period of LED light shall be 05 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over to contractor for replacement/repair. \n11. CA No. shall be written on each fitting before installation. \n12. The name of manufacturer to be embossed on the fitting. \n13. The fittings shall have arrangement so that maintenance required, if any can be carried out from Top cover.
30 29 S&F in replacement of MH Lamp 250 Watt tubular clear lamp on location including disconnecting and taking out of old unsv lamp of any type and make from light fitting and replacement of defective, complete all as specified and directed. 26 EACH
31 30 S&F in replacement heavy duty VPIT open construction copper ballast 250 Watt HPSV / MH for street light or flood light fitting including disconnecting and taking out of old unsv ballast of any type and make from light fitting and testing, complete all as specified and directed. 19 EACH
32 31 S&F in replacement ignitor elctronic 230V suitable 150 / 250 / 400 Watt HPSV/MH lamp fittings for street light or flood light fitting including disconnecting and taking out of old unsv ignitor of any type and make from light fitting and testing, complete all as specified and directed. 14 EACH
33 32 S&F in replacement of porcelain lamp holder suitable for 150 Watt to 250 Watt HPSV/MH lamp with base E 40 complete all as specified and directed. 13 EACH
34 33 M&L for overhauling & servicing of electrically operated panels of hanger sliding steel door. Each panel of approximate size 3.5 to 4.0 Metre in width and 10 Metre in height and from any door of hangers by taking out mechanical parts and electrical connections & carry out repairs of motor, gear box assembly, electric control panel including replacement of unserviceable components / spares / greasing etc. complete and re-assemble / reconnect all the parts/portions including testing to ensure efficient and smooth functioning of door, both electrically & manually etc, complete all as specified and directed. \nNotes :- \n1. Cost of replacement of all defective spares / parts except that covered in srl item No. 34.00 to 36.00 here-in-below are included in the job.\n2. Rate shall be quoted for each panel.\n 10 EachJob for each Panel
35 34 Supply only gear of existing pattern / type and make of gear assembly of hanger door repaired under srl item No. 33.00 above, complete all as specified and directed. \n 4 EACH
36 35 Supply only gear box of existing make / pattern and type suitable for hanger door repaired under srl item No. 33.00 above, complete all as specified and directed. 4 EACH
37 36 Rewinding of electric motor 1.1 KW / 1.5 HP with super enamelled copper winding wire of same gauge including impregnated paper, varnish and tape etc complete for hanger door repaired under srl item No. 33.00 above, complete all as specified and directed. \n 4 EACH
38 37 S & F 3 phase AC induction motor of Cap - 1.5 HP, S1 duty, IP-55, 415 v AC (+/-) 10 %, RPM- 1415, efficiency - 78 %. Including dismantling and taking down old defective damaged motor carefullly from the existing sliding hanger doors by provn of suitable safety measures compete all as specified and directed. 3 EACH
39 38 Supply, installation and testing of 200 Watt, optical design runway edge high intensity, yellow filter Bi-directional elevated halogen lamp light fitting with die-cast aluminium body and stainless steel hardware including bi-pin halogen lamp with all accessories such as base plate, breakable coupling mounting assembly, secondry lead conforming to relevant ICAO/FAA and IS including taking out existing unserviceable fitting of any type/description etc, complete all as specified and directed. \nNotes :-\n1. Quoted rates shall be included of taking out existing unserviceable runway fitting and fixing of new fitting over existing transformer housing box.\n2. Quoted rates shall be included of alignment, levelling, filling gap with sealent and HT self amalgamating PVC insulated tape.\n3. Quoted rates shall be included of crimping plug and receptacle connector.\n\n 2 EACH JOB
40 39 Supply, installation and testing of 200 Watt, optical design runway edge high intensity, Clear filter Bi-directional elevated halogen lamp light fitting with die-cast aluminium body and stainless steel hardware including bi-pin halogen lamp with all accessories such as base plate, breakable coupling mounting assembly, secondry lead conforming to relevant ICAO/FAA and IS including taking out existing unserviceable fitting of any type/description etc, complete all as specified and directed. \nNotes :- \n1. Quoted rates shall be included of taking out existing unserviceable runway fitting and fixing of new fitting over existing transformer housing box.\n2. Quoted rates shall be included of alignment, levelling, filling gap with sealent and HT self amalgamating PVC insulated tape.\n3. Quoted rates shall be included of crimping plug and receptacle connector.\n\n 2 EACH JOB
41 40 Supply, installation and testing of 200 Watt, optical design runway edge high intensity, 180° Green/Red filter Bi-directional elevated halogen lamp light fitting with die-cast aluminium body and stainless steel hardware including bi-pin halogen lamp with all accessories such as base plate, breakable coupling mounting assembly, secondry lead conforming to relevant ICAO/FAA and IS including taking out existing unserviceable fitting of any type/description etc, complete all as specified and directed. \nNotes :- \n1. Quoted rates shall be included of taking out existing unserviceable runway fitting and fixing of new fitting over existing transformer housing box.\n2. Quoted rates shall be included of alignment, levelling, filling gap with sealent and HT self amalgamating PVC insulated tape.\n3. Quoted rates shall be included of crimping plug and receptacle connector.\n\n 2 EACH JOB
42 41 Supply, installation and testing of 200 Watt, optical design runway edge high intensity, Uni-directional approch elevated halogen lamp light fitting with die cast aluminium body and stainless steel hardware including bi-pin halogen lamp with all accessories such as base plate, breakable coupling mounting assembly, secondry lead conforming to relevant ICAO/FAA and IS including taking out existing unserviceable fitting of any type/description etc complete all as specified and directed.\nNote:- \n1. Quoted rates are inclusive of taking out existing unserviceable runway fitting and fixing of new fitting over existing transformer housing box.\n2. Quoted rates are inclusive of alignment, levelling, filling gap with sealent and HT self amalgamating PVC insulated tape.\n3. Quoted rates are inclusive of crimping plug and receptacle connector. 1 EACH JOB
43 42 Supply, installation and testing of 45 Watt, optical design, Omni directional taxi way edge elevated halogen lamp light fitting with die-cast aluminium body and stainless steel hardware including bi-pin halogen lamp with all accessories such as base plate, breakable coupling mounting assembly, secondary lead conforming to relevant ICAO/FAA and IS including taking out existing unserviceable fitting of any type/description etc, complete all as specified and directed. \nNotes:- \n1. Quoted rates shall be included of taking out existing unserviceable runway light fitting and fixing of new fitting over existing transformer housing box.\n2. Quoted rates shall be included of alignment, levelling, filling gap with sealant and HT self amalgamating PVC insulated tape.\n3. Quoted rates shall be included of crimping plug and receptacle connector.\n\n 2 EACH JOB
44 43 Supply, installation, testing and commissioning of 5KV, 50 Hz, series type isolating transformer encapsulated in polyester resin finally moulded with neoprene rubber suitable for 200 Watt, 6.6 Amps runway/taxi light luminaire conforming to relevant FAA/CAO and IS including taking out existing unserviceable transformer etc, complete all as specified and directed. \nNotes :- \n1. Quoted rates shall be included of taking out unserviceable transformer from housing box and fixing the new one including making necessary electrical connections.\n 5 EACH
45 44 Supply, installation, testing and commissioning of 5KV, 50 Hz, series type isolating transformer encapsulated in polyester resin finally moulded with neoprene rubber suitable for 45 Watt, 6.6 Amps runway/taxi light luminaire conforming to relevant FAA/CAO and IS including taking out existing unserviceable transformer etc, complete all as specified and directed.\nNotes :- \n1. Quoted rates are inclusive of taking out unserviceable transformer from housing box and fixing the new one including making necessary electrical connections.\n 4 EACH
46 45 S&F in replacement 200 Watt 6.6 Amps bi-pin halogen lamp including taking out existing fused lamp of any type/description etc, complete all as specified and directed.\n 42 EACH
47 46 S&F in replacement 45 Watt 6.6 Amps bi-pin halogen lamp including taking out existing fused lamp of any type/description etc, complete all as specified and directed.\n 38 EACH
48 47 S&F in replacement lamp holder for halogen lamp suitable for 200/45 Watt runway/taxi light fitting including taking out existing unserviceable lamp holder of any type/description etc, complete all as specified and directed.\n 12 EACH
49 48 S&F in replacement base plate with breakable coupling suitable for 200/45 Watt runway/taxi light fitting including taking out existing unserviceable coupling of any type/description etc, complete all as specified and directed.\n 4 EACH
50 49 S&F in replacement mounting assembly suitable for 200/45 Watt runway/taxi light fitting including taking out existing unserviceable mounting assembly of any type/description etc, complete all as specified and directed.\n 5 EACH
51 50 S&F in replacement Lens filter of any type/colour suitable for 200 Watt halogen Uni/Bi directional optical design high intensity runway light fitting including taking out existing unserviceable lens filter of any type/description etc, complete all as specified and directed.\n 2 EACH
52 51 S&F in replacement Lens filter of any type/colour suitable for 45 Watt Omni directional taxi way edge elevated halogen lamp taxi light fitting including taking out existing unserviceable lens filter of any type/description etc, complete all as specified and directed.\n 3 EACH\nJOB
53 52 Servicing and monthly preventive maintenance of Five CCR panels controlling runway and taxiway halogen lamp light fittings including fault rectification and repair of printed circuit control card (thyristor type) by replacement of unserviceable spares viz transistors / ICs / resistance / capacitor etc. as and when required to keep the CCR Panel functional during contract period complete all as specified and directed. \nNotes :-\n(a) System shall be inspected / checked for preventive maintenance once in a month. \n(b) Quoted rates shall be included of replacement of unserviceable spares viz transistors / ICs / resistance / capacitor etc. \n(c) Labour element for changing spares included in quoted rate. (d) Quoted rate shall be include fault repair as and when required.\n(e) Quoted rates shall be for each month.\n(f) Printed circuit control card if replaced shall be included in quoted rates.\n(g) Replacement of unserviceable spares viz transistors / ICs / resistance / capacitor etc shall be of same makes as per existing in the CCR Panels.\n(h) One technician shall be provided by the contractor for opening of CCR panels/Runway & Taxi way lights as per flying schedule of AVN and all as specified and directed by Engineer-in-Charge. Provn of technicians shall be included in quoted rate. 11 PER MONTH
54 53 Supply only printed circuit control card (thyristor type) suitable for CCR panel to suit existing etc, complete all as specified and directed.\n 2 EACH
55 54 Supply, laying and testing 6 sqmm, single core, 5KV grade stranded copper conductor PVC insulated and sheathed runway cable laid in trenches / wall / pipe jointed using plug receptacle including taking out unserviceable cable of any type / description etc, complete all as specified and directed. \nNotes :- \n1. Excavation and earthwork required for dismantling and taking out cable will be measured and paid separately under respective items of BOQ.\n2. Serviceable cable shall be segregated for reuse in same or new location, quoted rate are included for segregation for serviceable cable.\n3. plug receptacle connector (ESSMA) shall be measured and paid separately under respective item od BOQ).\n\n 341 RM
56 55 Supply only plug receptacle connector (ESSMA) suitable for 5KW, 6 sqmm copper conductor cable etc, complete all as specified and directed.\n 12 EACH
57 56 Taking down carefully aluminium/copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendent, regulators, sockets, bell push, bell, light fittings etc. removing serviceable materials to store for keeping in safe custody for reuse at site or for taking credit (Credit shall be made as per Schedule of credit), removing rubbish from the site and making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces. 343 POINT
58 57 M&L for point wiring complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3mm thick bakelite sheet white/coloured top cover for:-\n(a) One light/fan/bell point controlled by one, one way switch.\n 239 POINT
59 58 All as per item No. 57.00 above but one 3 pin 5 or 6 Amps socket outlet on independent board with other switches as directed. 27 POINT
60 59 All as per item No. 57.00 above but one 3 pin 5 or 6 Amps socket outlet on same board with other switches as directed. 55 POINT
61 60 All as per item No. 57.00 above but one 3 pin 5 or 6 Amps socket outlet on independent board with other switches but below the switch board of light points in the same vertical plane as directed. 35 POINT
62 61 M&L for point wiring complete with 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1. 8mm heavy duty including conduit accessories concealed in wall, ceiling etc including sunken type pressed steel terminal boxes of size 175/100mm with 3mm thick bakelite sheet cover white/coloured including 2.5 Sqmm, single core, PVC insulated but unsheathed copper conductor FRLS 1100 volts grade cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board. \n 42 POINT
63 62 S&F switch piano flush button single pole one way 6 amps 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge. \n 341 EACH
64 63 S&F switch piano flush button single pole one way 16 amps 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.\n 42 EACH
65 64 S&F bell push flush button single pole one way 6 amps 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.\n 15 EACH
66 65 S&F socket out let, 5 pin 6 amps multi purpose 2 in 1 flush type, 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge. \n 117 EACH
67 66 S&F socket out let, 6 pin 6 & 16 amps multi purpose 2 in 1 flush type, 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge. \n 42 EACH
68 67 S&F ceiling rose 3 terminals PVC / Polycarbonate insulated body 65mmx 50mm size complete all as specified and directed. 169 EACH
69 68 S&F for lamp holder insulated body of PVC / polycarbonate type with back plate suitable for Angle/ batten fittings including self ballasted LED retrofit bulb 15 watt with PBT body shell and PC Diffuser. 240 Degree wide distribution available CCT 3000K & 6500 K complete all as specified and directed. 65 EACH
70 69 S&F bell electric heavy duty Ding Dong type 230 volts single pole all as specified and directed by Engineer-in-Charge. \n 15 EACH
71 70 S&F fan regulator electronic, switch type hum free with polycarbonate body suitable to control speed of fan from 0 to 100% and connecting electrically all as specified and directed by Engineer-in-Charge. \n 37 EACH
72 71 Supply and fixing self ballast LED batten extruded theremoplastic body with PC diffuser in unique square shape > 120 degree wide distribution, 4 feet 20 W LED batten 4 feet 20 W, CCT 6500 K Complete including connection upto ceiling rose with flexible copper twin twisted wire complete all as specified and directed. 85 EACH
73 72 Supply and fixing self ballast LED batten extruded theremoplastic body with PC diffuser in unique square shape > 120 degree wide distribution, 1 feet 8 W LED batten 1 feet 8 W, CCT 6500 K Complete including connection upto ceiling rose with flexible copper twin twisted wire complete all as specified and directed. 12 EACH
74 73 S&F surface mounted LED Bulk Head luminaires 10 watts with ABS body & polycarbonate diffuser available in CCT 6000K IP 54 complete all as specified and directed. 55 EACH
75 74 M&L for sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade of size 6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge.\nNOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.\n 171 RM
76 75 S&F in repairs and testing factory made sheet metal enclosure for MCB DB SPN 8 way 240 volt with single door, IP - 43 protection duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type all as directed by Engineer-in-Charge as per Cat Part No. 6077708 of Make- Legrand or equivalent of any Make specified in Appx 'B'. 7 EACH\n
77 76 S&F in repairs MCB single pole 230 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, 'C' curve type, including providing thimble for out going cables. 42 EACH
78 77 S&F in repairs MCB single pole and neutral 240 volts any rating from 10 to 63 amps, with rupturing capacity 10 KA, 'C' curve type, including providing thimble for out going cables. 7 EACH
79 78 S&F and testing factory made sheet metal enclosure for MCB DB TPN 4 way 415 volt with double door, IP - 43 protection duly with fixed in wall/ concealed in wall complete and making good disturbed surfaces of wall, floor etc including electric wire connection all as directed by Engineer-in-Charge. 2 EACH
80 79 S&F in replacement modular switch 1 way 6 Amp, 1 module complete all as specified and directed. \n 35 EACH
81 80 S&F in replacement modular switch 1 way 16 Amp, 1 module complete all as specified and directed. \n 27 EACH
82 81 S&F in replacement modular socket 6 Amp, 2/3 pin mutipurpose 2 module complete all as specified and directed. \n 45 EACH
83 82 S&F in replacement modular socket 6 Amp/16 Amp, 6 pin multi purpose 2 module complete all as specified and directed. \n 32 EACH
84 83 S&F in replacement modular fan step regulator, 120W, 2 module, hum free and connecting electrically all as specified and directed by Engineer-in-Charge. \n 12 EACH
85 84 S&F modular bell push flush button single pole one way 6 amps 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.\n 8 EACH
86 85 S&F for MCB TP 100 Amps breaking capacity 10 KA 'C' series 415 volts 50 Hz complete all as specified and directed. 4 EACH
87 86 S&F in repairs single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amp ‘C’ curve type, 230 volts, 10 KA. 7 EACH
88 87 Supply and fixing of Recessed/Surface mounting 36W LED luminaire, prewired with white powder coated CRCA housing with LEDs and fully window acrylic diffuser, suitable for 600x600mm E-grid/POP ceiling complete with all accessories making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed. 15 EACH
89 88 S&F in repacement of 3 lines LCD display in 96x96 Sqmm flush mounted case Accuracy class 1.0 & 0.5 Panel mounted multi functional meters complete all as specified and directed. 3 EACH
90 89 S&F in replacement of panle indicator LED Lamps RYB - 03 Nos incl Green 04 Nos suitable for 240 VAC complete all as specified and directed. 7 EACH
91 90 S&F in replacement of two position panle selector switch complete all as specified and directed. 4 EACH
92 91 S&F in replacement industrial panle socket of rating 16A -6h, 2P+Earth of cap 200-250 VAC complete all as specified and directed. 5 EACH
93 92 S&F in replacement industrial panle socket of rating 63A -6h, 3P+N+Earth of Cap 240 - 415 VAC complete all as specified and directed. 6 EACH
94 93 S&F in replacement of MCB TPN of Cap 32 Amps C series complete all as specified and directed. 4 EACH
95 94 Note:- Cutting chases in walls/floors/ceilings wherever required for electric work shall be deemed to be included in respective item of Schedule ‘A’.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2020 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail