Power Government Departments Closing in 0 days TDR #25715484

Annual Rate Contract For Different Work Creation , Augmentation And Ht/Lt Lines

Issued by Government Departments · Poonch, Jammu And Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Oct 2020
0 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Poonch → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Annual Rate Contract For Different Work Creation , Augmentation And Ht / Lt Lines-1 Erection of 11 KV (HT) Line n(Note: For detailed specifications please refer attached SBD which forms a part of the tender) 2 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard) 3 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles (410, SP-33) with pit excavation. (As per recommended IS/REC Standard) 4 Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1800mm for ST Poles for refilling the pit (the leftover pit after concreting to be filled with soil and boulders) nNOTE: Please refer Pole drawings for details. (As per recommended IS/REC Standard) 5 Supplying and erection of GI Channel “V’ cross-arm (75 x 40x6mm) with GI Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole structure. nNOTE: Please refer Pole drawings for details (As per recommended IS/REC Standard) 6 Supplying and erection of GI channel (75x40x6 mm) cross arms for H-frames, GI Angle( 50x50x6 mm) cross braces for H-frames, 50X50X6 mm angle support for guard netting including clamps as per REC standard. (As per recommended IS/REC Standard) 7 Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard) 8 Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (As per recommended IS/REC Standard) 9 Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points. (As per recommended IS/REC Standard) 10 Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection (As per recommended IS/REC Standard) 11 Supplying and erection of Danger Plates with clamps with writing in English and Regional Language 12 Supply and fixing of anti-climbing Device/GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose. (As per recommended IS/REC Standard) 13 Supplying and fixing of Galvanized Nuts and Bolts of sizes. 14 Supply and fixing of Parallel Grove (PG) clamps, binding wire etc 15 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size n30 mm2 ACSR ( Weasel) (As per recommended IS/REC Standard) 16 Supply and painting of each Pole along with accessories by 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) 17 Supply and Fixing of Aluminium Jointing Sleeves 18 Erection of 11/0.433 kV Distribution Transformer n(Note: For detailed specifications please refer attached SBD which forms a part of the tender) 19 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 25kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate.(As per recommended IS/REC Standard) 20 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 63kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate.(As per recommended IS/REC Standard) 21 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 100kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate. (As per recommended IS/REC Standard) 22 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 250kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate. (As per recommended IS/REC Standard) 23 Supply and installation of LT bi-metalic connectors for making connection from DT bush rod to aluminium cables (As per recommended IS/REC Standard) 24 Supply and fixing of LT Distribution Box for 25 KVA DTR with TPN MCCBs for incomer and suitable MCCBs for outgoing circuits with terminal extensions. (As per recommended IS/REC Standard) 25 Supply and fixing of LT Distribution Box for 63 KVA DTR with TPN MCCBs for incomer and suitable MCCBs for outgoing circuits with terminal extensions. (As per recommended IS/REC Standard) 26 Supply and fixing of LT Distribution Box for 100 KVA DTR with TPN MCCBs for incomer and suitable MCCBs for outgoing circuits with terminal extensions. (As per recommended IS/REC Standard) 27 Supply and fixing of LT Distribution Box for 250 KVA DTR with TPN MCCBs for incomer and suitable MCCBs for outgoing circuits with terminal extensions. (As per recommended IS/REC Standard) 28 Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard) 29 Supply and installation of 11 kV Disc Insulators (polymer) Complete with fitting( 45 KN) (As per recommended IS/REC Standard) 30 Supply and installation of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type (As per recommended IS/REC Standard) 31 Supply and installation of 11 kV, G.O AB Switch , 3-phase, 200A (As per recommended IS/REC Standard) 32 Supply and installation of 11 kV Horn, Gap Fuse Set, 3-phase, 100A (As per recommended IS/REC Standard) 33 Supply and fixing of Un Armoured Single Core XPLE, FRLS Cable (70 mm2) (As per recommended IS/REC Standard) 34 Supply and fixing of Un Armoured Single Core XPLE, FRLS Cable (120 mm2) (As per recommended IS/REC Standard) 35 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles (410 SP-33) with pit excavation n(Note: The poles shall be provided by JKPDD) (As per recommended IS/REC Standard) 36 Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1800mm for ST Poles for refilling the pit (the leftover pit after concreting to be filled with soil and boulders) nNOTE: Please refer Pole drawings for details. (As per recommended IS/REC Standard) 37 Supplying and erection of GI channel/angle cross arms including fixing GI channels ( 100x50x6mm) / (75x40x6 mm) / angles(50x50x6 mm) with 50X8 mm back clamps without drilling/punching holes in the poles. (As per recommended IS/REC Standard) 38 Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nutbolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points as per REC standard. (As per recommended IS/REC Standard) 39 Excavation of Earthing Pits of dia = 600 mm and depth= 3000 mm, Supplying and fixing of 3 No. sub station earthing by GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 mm 1 no for neutral earthing and 25X3 mm 2 nos (for 2 Nos transformer body earth, 2 Nos Pole earth, 1 no. LA Earth and 1 no. GO handle earth). (Note: For LA Earth 1 pipe shall be kept separate) GI Nuts, Bolts and Clamps, refilled with earth enhancement materials and earthing chamber made of brick masonary with RCC Slab Cover. (As per recommended IS/REC Standard) 40 Supplying and erection of 11kV Danger Plates with clamps with writing in English and Regional Language 41 Supplying and fixing of Galvanized Nuts and Bolts of sizes. 42 Supply and fixing of Sundry Items (Aluminum lugs for fixing cable to MCCB – 8 nos including crimping of the lugs, jumpering of DT accessories through ACSR Conductor, Binding Tapes) (As per recommended IS/REC Standard) 43 Supply and painting of each Pole along with accessories by 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) 44 Supply and Fixing of Wedge Connectors/PG Clamps (As per recommended IS/REC Standard) 45 Supply and fixing of anti-climbing GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose. (As per recommended IS/REC Standard) 46 Supply and fixing of Required Amperage Three Phase Four Wire Trivector Transformer Meter with CT of Required Ratio. (As per recommended IS/REC Standard) 47 Erection of LT Line on Conductor, 3-Ph, 4-wire,2-Ph, 3-wire,1-Ph, 2-wire n 48 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard) 49 Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1800mm for ST Poles for refilling the pit (the leftover pit after concreting to be filled with soil and boulders) nNOTE: Please refer Pole drawings for details. (As per recommended IS/REC Standard) 50 Supply and fixing of Mukky clamps for LT Shackle insulators with GI back clamps to be fixed without drilling/punching of poles on ST poles. (As per recommended IS/REC Standard) 51 Supplying and fixing of Shackle Insulators (polymer) ( 16 KN) (As per recommended IS/REC Standard) 52 Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points as per REC standard.(As per recommended IS/REC Standard) 53 Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection (As per recommended IS/REC Standard) 54 Supplying and erection of Danger Plates with clamps with writing in English and Regional Language 55 Supplying and fixing of Galvanized Nuts and Bolts of sizes. 56 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size n30 mm2 ACSR (Weasel) (As per recommended IS/REC Standard) 57 Supply and fixing of LT line spacers: n4 Wire n3 Wire 58 Supply and painting of each Pole along with accessories by 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) 59 Supply and fixing of anti-climbing Device/GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose. (As per recommended IS/REC Standard)

BOQ

Name of Work: Annual Rate contract for different works under the jurisdiction of Sub Division Surankote for the year 2020-21
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Erection of 11 KV (HT) Line\n(Note: For detailed specifications please refer attached SBD which forms a part of the tender)
21.01Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard)item1.011Nos
31.02Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles (410, SP-33) with pit excavation. (As per recommended IS/REC Standard)item1.021Nos
41.03Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1800mm for ST Poles for refilling the pit (the leftover pit after concreting to be filled with soil and boulders)\nNOTE: Please refer Pole drawings for details. (As per recommended IS/REC Standard)item1.031Nos
51.04Supplying and erection of GI Channel “V’' cross-arm (75 x 40x6mm) with GI Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole structure. \nNOTE: Please refer Pole drawings for details (As per recommended IS/REC Standard)item1.041Kgs
61.05Supplying and erection of GI channel (75x40x6 mm) cross arms for H-frames, GI Angle( 50x50x6 mm) cross braces for H-frames, 50X50X6 mm angle support for guard netting including clamps as per REC standard. (As per recommended IS/REC Standard)item1.051Kgs
71.06Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard)item1.061Nos
81.07Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (As per recommended IS/REC Standard)item1.071Nos
91.08Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points. (As per recommended IS/REC Standard)item1.081Nos
101.09Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection (As per recommended IS/REC Standard)item1.091Nos
111.1Supplying and erection of Danger Plates with clamps with writing in English and Regional Languageitem1.11Nos
121.11Supply and fixing of anti-climbing Device/GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose. (As per recommended IS/REC Standard)item1.111Nos
131.12Supplying and fixing of Galvanized Nuts and Bolts of sizes.item1.121Kgs
141.13Supply and fixing of Parallel Grove (PG) clamps, binding wire etcitem1.131Nos
151.14Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size\n30 mm2 ACSR ( Weasel) (As per recommended IS/REC Standard)item1.141Kms
161.15Supply and painting of each Pole along with accessories by 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)item1.151Nos
171.16Supply and Fixing of Aluminium Jointing Sleevesitem1.161Nos
182Erection of 11/0.433 kV Distribution Transformer\n(Note: For detailed specifications please refer attached SBD which forms a part of the tender)
192.01Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 25kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate.(As per recommended IS/REC Standard)item2.011Nos
202.02Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 63kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate.(As per recommended IS/REC Standard)item2.021Nos
212.03Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 100kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate. (As per recommended IS/REC Standard)item2.02a1Nos
222.04Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 250kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate. (As per recommended IS/REC Standard)item2.031Nos
232.05Supply and installation of LT bi-metalic connectors for making connection from DT bush rod to aluminium cables (As per recommended IS/REC Standard)item2.041Nos
242.06Supply and fixing of LT Distribution Box for 25 KVA DTR with TPN MCCBs for incomer and suitable MCCBs for outgoing circuits with terminal extensions. (As per recommended IS/REC Standard)item2.051Nos
252.07Supply and fixing of LT Distribution Box for 63 KVA DTR with TPN MCCBs for incomer and suitable MCCBs for outgoing circuits with terminal extensions. (As per recommended IS/REC Standard)item2.05a1Nos
262.08Supply and fixing of LT Distribution Box for 100 KVA DTR with TPN MCCBs for incomer and suitable MCCBs for outgoing circuits with terminal extensions. (As per recommended IS/REC Standard)item2.061Nos
272.09Supply and fixing of LT Distribution Box for 250 KVA DTR with TPN MCCBs for incomer and suitable MCCBs for outgoing circuits with terminal extensions. (As per recommended IS/REC Standard)item2.06a1Nos
282.1Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard)item2.071Nos
292.11Supply and installation of 11 kV Disc Insulators (polymer) Complete with fitting( 45 KN) (As per recommended IS/REC Standard)item2.081Nos
302.12Supply and installation of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type (As per recommended IS/REC Standard)item2.091Set
312.13Supply and installation of 11 kV, G.O AB Switch , 3-phase, 200A (As per recommended IS/REC Standard)item2.101Set
322.14Supply and installation of 11 kV Horn, Gap Fuse Set, 3-phase, 100A (As per recommended IS/REC Standard)item2.111Set
332.15Supply and fixing of Un Armoured Single Core XPLE, FRLS Cable (70 mm2) (As per recommended IS/REC Standard)item2.121Mtr
342.16Supply and fixing of Un Armoured Single Core XPLE, FRLS Cable (120 mm2) (As per recommended IS/REC Standard)item2.131Mtr
352.17Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles (410 SP-33) with pit excavation\n(Note: The poles shall be provided by JKPDD) (As per recommended IS/REC Standard)item2.141Nos
362.18Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1800mm for ST Poles for refilling the pit (the leftover pit after concreting to be filled with soil and boulders)\nNOTE: Please refer Pole drawings for details. (As per recommended IS/REC Standard)item2.151Nos
372.19Supplying and erection of GI channel/angle cross arms including fixing GI channels ( 100x50x6mm) / (75x40x6 mm) / angles(50x50x6 mm) with 50X8 mm back clamps without drilling/punching holes in the poles. (As per recommended IS/REC Standard)item2.161Kgs
382.2Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nutbolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points as per REC standard. (As per recommended IS/REC Standard)item2.171Set
392.21Excavation of Earthing Pits of dia = 600 mm and depth= 3000 mm, Supplying and fixing of 3 No. sub station earthing by GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 mm 1 no for neutral earthing and 25X3 mm 2 nos (for 2 Nos transformer body earth, 2 Nos Pole earth, 1 no. LA Earth and 1 no. GO handle earth). (Note: For LA Earth 1 pipe shall be kept separate) GI Nuts, Bolts and Clamps, refilled with earth enhancement materials and earthing chamber made of brick masonary with RCC Slab Cover. (As per recommended IS/REC Standard)item2.181Nos
402.22Supplying and erection of 11kV Danger Plates with clamps with writing in English and Regional Languageitem2.191Nos
412.23Supplying and fixing of Galvanized Nuts and Bolts of sizes.item2.201Kgs
422.24Supply and fixing of Sundry Items (Aluminum lugs for fixing cable to MCCB – 8 nos including crimping of the lugs, jumpering of DT accessories through ACSR Conductor, Binding Tapes) (As per recommended IS/REC Standard)item2.211LS
432.25Supply and painting of each Pole along with accessories by 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)item2.221Nos
442.26Supply and Fixing of Wedge Connectors/PG Clamps (As per recommended IS/REC Standard)item2.231Nos
452.27Supply and fixing of anti-climbing GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose. (As per recommended IS/REC Standard)item2.241Kgs
462.28Supply and fixing of Required Amperage Three Phase Four Wire Trivector Transformer Meter with CT of Required Ratio. (As per recommended IS/REC Standard)item2.251Nos
473Erection of LT Line on Conductor, 3-Ph, 4-wire,2-Ph, 3-wire,1-Ph, 2-wire\n
483.01Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard)item3.011Nos
493.02Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1800mm for ST Poles for refilling the pit (the leftover pit after concreting to be filled with soil and boulders)\nNOTE: Please refer Pole drawings for details. (As per recommended IS/REC Standard)item3.021Nos
503.03Supply and fixing of Mukky clamps for LT Shackle insulators with GI back clamps to be fixed without drilling/punching of poles on ST poles. (As per recommended IS/REC Standard)item3.031Nos
513.04Supplying and fixing of Shackle Insulators (polymer) ( 16 KN) (As per recommended IS/REC Standard)item3.041Nos
523.05Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points as per REC standard.(As per recommended IS/REC Standard)item3.051Sets
533.06Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection (As per recommended IS/REC Standard)item3.061Nos
543.07Supplying and erection of Danger Plates with clamps with writing in English and Regional Languageitem3.071Nos
553.08Supplying and fixing of Galvanized Nuts and Bolts of sizes.item3.081Kgs
563.09Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size\n30 mm2 ACSR (Weasel) (As per recommended IS/REC Standard)item3.091Kms
573.1Supply and fixing of LT line spacers: \n4 Wire\n3 Wireitem3.11Nos
583.11Supply and painting of each Pole along with accessories by 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)item3.111Nos
593.12Supply and fixing of anti-climbing Device/GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose. (As per recommended IS/REC Standard)item3.121Nos

AI Tender Summary

OUR REF NO 25715484
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 28-10-2020
Authority
Authority Name Power Development Department
Work Description Annual Rate Contract For Different Work Creation , Augmentation And Ht / Lt Lines-1 Erection of 11 KV (HT) Line n(Note: For detailed specifications please refer attached SBD which forms a part of the tender) 2 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard) 3 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles (410, SP-33) with pit excavation. (As per recommended IS/REC Standard) 4 Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1800mm for ST Poles for refilling the pit (the leftover pit after concreting to be filled with soil and boulders) nNOTE: Please refer Pole drawings for details. (As per recommended IS/REC Standard) 5 Supplying and erection of GI Channel “V’ cross-arm (75 x 40x6mm) with GI Angle Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole structure. nNOTE: Please refer Pole drawings for details (As per recommended IS/REC Standard) 6 Supplying and erection of GI channel (75x40x6 mm) cross arms for H-frames, GI Angle( 50x50x6 mm) cross braces for H-frames, 50X50X6 mm angle support for guard netting including clamps as per REC standard. (As per recommended IS/REC Standard) 7 Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard) 8 Supplying and fixing of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (As per recommended IS/REC Standard) 9 Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points. (As per recommended IS/REC Standard) 10 Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection (As per recommended IS/REC Standard) 11 Supplying and erection of Danger Plates with clamps with writing in English and Regional Language 12 Supply and fixing of anti-climbing Device/GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose. (As per recommended IS/REC Standard) 13 Supplying and fixing of Galvanized Nuts and Bolts of sizes. 14 Supply and fixing of Parallel Grove (PG) clamps, binding wire etc 15 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size n30 mm2 ACSR ( Weasel) (As per recommended IS/REC Standard) 16 Supply and painting of each Pole along with accessories by 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) 17 Supply and Fixing of Aluminium Jointing Sleeves 18 Erection of 11/0.433 kV Distribution Transformer n(Note: For detailed specifications please refer attached SBD which forms a part of the tender) 19 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 25kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate.(As per recommended IS/REC Standard) 20 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 63kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate.(As per recommended IS/REC Standard) 21 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 100kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate. (As per recommended IS/REC Standard) 22 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and installation of 250kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Aluminium Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate. (As per recommended IS/REC Standard) 23 Supply and installation of LT bi-metalic connectors for making connection from DT bush rod to aluminium cables (As per recommended IS/REC Standard) 24 Supply and fixing of LT Distribution Box for 25 KVA DTR with TPN MCCBs for incomer and suitable MCCBs for outgoing circuits with terminal extensions. (As per recommended IS/REC Standard) 25 Supply and fixing of LT Distribution Box for 63 KVA DTR with TPN MCCBs for incomer and suitable MCCBs for outgoing circuits with terminal extensions. (As per recommended IS/REC Standard) 26 Supply and fixing of LT Distribution Box for 100 KVA DTR with TPN MCCBs for incomer and suitable MCCBs for outgoing circuits with terminal extensions. (As per recommended IS/REC Standard) 27 Supply and fixing of LT Distribution Box for 250 KVA DTR with TPN MCCBs for incomer and suitable MCCBs for outgoing circuits with terminal extensions. (As per recommended IS/REC Standard) 28 Supplying and fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard) 29 Supply and installation of 11 kV Disc Insulators (polymer) Complete with fitting( 45 KN) (As per recommended IS/REC Standard) 30 Supply and installation of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type (As per recommended IS/REC Standard) 31 Supply and installation of 11 kV, G.O AB Switch , 3-phase, 200A (As per recommended IS/REC Standard) 32 Supply and installation of 11 kV Horn, Gap Fuse Set, 3-phase, 100A (As per recommended IS/REC Standard) 33 Supply and fixing of Un Armoured Single Core XPLE, FRLS Cable (70 mm2) (As per recommended IS/REC Standard) 34 Supply and fixing of Un Armoured Single Core XPLE, FRLS Cable (120 mm2) (As per recommended IS/REC Standard) 35 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 9 Mtr. Long ST Poles (410 SP-33) with pit excavation n(Note: The poles shall be provided by JKPDD) (As per recommended IS/REC Standard) 36 Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1800mm for ST Poles for refilling the pit (the leftover pit after concreting to be filled with soil and boulders) nNOTE: Please refer Pole drawings for details. (As per recommended IS/REC Standard) 37 Supplying and erection of GI channel/angle cross arms including fixing GI channels ( 100x50x6mm) / (75x40x6 mm) / angles(50x50x6 mm) with 50X8 mm back clamps without drilling/punching holes in the poles. (As per recommended IS/REC Standard) 38 Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nutbolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points as per REC standard. (As per recommended IS/REC Standard) 39 Excavation of Earthing Pits of dia = 600 mm and depth= 3000 mm, Supplying and fixing of 3 No. sub station earthing by GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 mm 1 no for neutral earthing and 25X3 mm 2 nos (for 2 Nos transformer body earth, 2 Nos Pole earth, 1 no. LA Earth and 1 no. GO handle earth). (Note: For LA Earth 1 pipe shall be kept separate) GI Nuts, Bolts and Clamps, refilled with earth enhancement materials and earthing chamber made of brick masonary with RCC Slab Cover. (As per recommended IS/REC Standard) 40 Supplying and erection of 11kV Danger Plates with clamps with writing in English and Regional Language 41 Supplying and fixing of Galvanized Nuts and Bolts of sizes. 42 Supply and fixing of Sundry Items (Aluminum lugs for fixing cable to MCCB – 8 nos including crimping of the lugs, jumpering of DT accessories through ACSR Conductor, Binding Tapes) (As per recommended IS/REC Standard) 43 Supply and painting of each Pole along with accessories by 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) 44 Supply and Fixing of Wedge Connectors/PG Clamps (As per recommended IS/REC Standard) 45 Supply and fixing of anti-climbing GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose. (As per recommended IS/REC Standard) 46 Supply and fixing of Required Amperage Three Phase Four Wire Trivector Transformer Meter with CT of Required Ratio. (As per recommended IS/REC Standard) 47 Erection of LT Line on Conductor, 3-Ph, 4-wire,2-Ph, 3-wire,1-Ph, 2-wire n 48 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site and erection of 8 Mtr. Long ST Poles (410, SP-15) with pit excavation. (As per recommended IS/REC Standard) 49 Supply and laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole, muffing 20 cm above ground level ,including plaster and curing of concrete in size of 600x600x1800mm for ST Poles for refilling the pit (the leftover pit after concreting to be filled with soil and boulders) nNOTE: Please refer Pole drawings for details. (As per recommended IS/REC Standard) 50 Supply and fixing of Mukky clamps for LT Shackle insulators with GI back clamps to be fixed without drilling/punching of poles on ST poles. (As per recommended IS/REC Standard) 51 Supplying and fixing of Shackle Insulators (polymer) ( 16 KN) (As per recommended IS/REC Standard) 52 Supply and erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points as per REC standard.(As per recommended IS/REC Standard) 53 Supplying and fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150 on pole for earth connection (As per recommended IS/REC Standard) 54 Supplying and erection of Danger Plates with clamps with writing in English and Regional Language 55 Supplying and fixing of Galvanized Nuts and Bolts of sizes. 56 Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site, Laying, stringing and binding of conductor including joints with PG clamps of required size n30 mm2 ACSR (Weasel) (As per recommended IS/REC Standard) 57 Supply and fixing of LT line spacers: n4 Wire n3 Wire 58 Supply and painting of each Pole along with accessories by 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint) 59 Supply and fixing of anti-climbing Device/GI Barbed wire binding with Clamps at a distance of 30 to 40 cm at a height of 3.5 to 4 m from ground level. At-least 2 kgs GI barbed wire(12 SWG) is to be used per pole for the purpose. (As per recommended IS/REC Standard)
Basic Detail
Tender No e-NIT No/EDP.10 of 2020-21 dated.13.10.2020
Bidding Type Tender
Location
City Poonch
State Jammu And Kashmir
Key Dates
Publish Date 14 Oct 2020
Submission Date 28 Oct 2020
Open Date 31 Oct 2020
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 20000
Exemption Not Available
Document List
Tendernotice_3.pdf
Tendernotice_2.pdf
BOQ_SKT.xls
Tendernotice_1.pdf
C2DC9084-4BFE-4DA9-83AD-0D0DB2C6779C.html
Tendernotice_4.pdf
BOQ_204191.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 14, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 28, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 31, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_3.pdf

pdf

Tendernotice_2.pdf

xls

BOQ_SKT.xls

pdf

Tendernotice_1.pdf

html

C2DC9084-4BFE-4DA9-83AD-0D0DB2C6779C.html

pdf

Tendernotice_4.pdf

xls

BOQ_204191.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender