}

3.3Kv, 3 Phase Ht Mcc Panel With One Incoming Vcb Feeder And Two Outgoing Vcu Feeders With Following Components As Given Below. 3.3 Kv Phase 1250 Rated Heat Shrinkable Sleeved Aluminum Bushes Connected To Vcb Incomer Feeder And Vcu Outgoing Feeders V-Chhattisgarh

Nmdc Limited has published 3.3Kv, 3 Phase Ht Mcc Panel With One Incoming Vcb Feeder And Two Outgoing Vcu Feeders With Following Components As Given Below. 3.3 Kv Phase 1250 Rated Heat Shrinkable Sleeved Aluminum Bushes Connected To Vcb Incomer Feeder And Vcu Outgoing Feeders V. Submission Date for this Tender is 03-11-2020. Circuit Breakers Tenders in Chhattisgarh. Bidders can get complete Tender details and download the document.




Tender Notice

25705538
3.3Kv, 3 Phase Ht Mcc Panel With One Incoming Vcb Feeder And Two Outgoing Vcu Feeders With Following Components As Given Below. 3.3 Kv Phase 1250 Rated Heat Shrinkable Sleeved Aluminum Bushes Connected To Vcb Incomer Feeder And Vcu Outgoing Feeders V
Tender
Indian
Chhattisgarh
03-11-2020

Tender Details

3.3Kv, 3 Phase Ht Mcc Panel With One Incoming Vcb Feeder And Two Outgoing Vcu Feeders With Following Components As Given Below. 3.3 Kv Phase 1250 Rated Heat Shrinkable Sleeved Aluminum Bushes Connected To Vcb Incomer Feeder And Vcu Outgoing Feeders Vbc : 3.3 Kv, 800A, 25Ka For 3 Sec, Horizontal Isolation And Horizontal Draw Out Type With Mortised And Manual Spring Charging Mechanism. Electrical And Manual Breaker Closing & Tripping Mechanism. Vcb Should Have Sufficient Number Of Auxiliary Contact Block / Secondary Terminals With Minimum Spare Of 4No + 4Nc For Future Use Power Source: Suitable Rated Power Sources To Be Provided In The Panel For Electrical Operation Of Spring Charging, Closing & Tripping Of Vcb. Vacuum Contactor Unit: 3.3 Kv, 400A, Non ? Latching And Draw Out Type With Closing Coil. Vacuum Contactor Unit Should Have Sufficient Number Of Auxiliary Contact Block / Secondary Terminals With Minimum Spare Of 4No + 4 Nc For Future Use. Power Source: Suitable Rated Power Sources To Be Provided In The Panels For Closing Coil Operation Of Vacuum Contactor Units. Ct : 400 / 5+5A. 15Va, Cl1.0 For Metering And Cl5p20 For Protection To Be Provided In Each Phase. Ct: 200 / 5+5A, 15Va, Cl1.0 For Metering And Cl5p20 For Protection To Be Provided In Each Phase. Pt: A Set Of 3 Nos. Of Single Phase 3300 / V3 / 110 / V3, 100Va, Class 1.0 / 3P Draw Out Type Pts With Ht And Lt Fuses. Suitable Rated Led Indication Lamps: For Vcb & Vcu On / Off / Trip Circuit Healthy / Spring Charged Etc. And Incoming Phase Indication Dc On / Off Switch Ac On / Off Switch Heater With Heater Switch & Thermostat

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail