Repair/ Replacement Of Conventional Security Lights With Led 60 Watt Security Lights , Lt Panel , Lt Underground Cable And Its Connectiing Accessories From Bana Enclave To Khetrapal Enclave Under Ge ( S ) Mamun At Mamun Mil Station

Tender Notice

25697280
Repair/ Replacement Of Conventional Security Lights With Led 60 Watt Security Lights , Lt Panel , Lt Underground Cable And Its Connectiing Accessories From Bana Enclave To Khetrapal Enclave Under Ge ( S ) Mamun At Mamun Mil Station
Indian
Punjab
12-10-2020
07-11-2020
09-11-2020

Tender Details

Repair/ Replacement Of Conventional Security Lights With Led 60 Watt Security Lights , Lt Panel , Lt Underground Cable And Its Connectiing Accessories From Bana Enclave To Khetrapal Enclave Under Ge ( S ) Mamun At Mamun Mil Station

Key Value

Document Fees
INR 1000 /-
EMD
INR 75000.00 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/ REPLACEMENT OF CONVENTIONAL SECURITY LIGHTS WITH LED 60 WATT SECURITY LIGHTS, LT PANEL, LT UNDERGROUND CABLE AND ITS CONNECTIING ACCESSORIES FROM BANA ENCLAVE TO KHETRAPAL ENCLAVE UNDER GE (S) MAMUN AT MAMUN MIL STATION (JOB NO SHM/02/SR/MES/2020-21)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down carefully street light/flood light fitting of any type/description from poles/walls or any other location & depositing in MES installation for reuse of serviceable fittings in another location in Cantt area complete all as spd and directed. (Note:- The fitting found unserviceable shall be given to contractor in credit as per details included in Sch of credit) 266 Each
2 2 S&F 60W LED Street Light luminaire made up of Pressure Die Cast aluminium housing with black epoxy polyester powder coating for long life. The luminaire shall have IP66 protection for Optical Compartment and Control Gear Compartment. The Optical compartment shall be covered with heat resistant toughened glass for safety. The LED street light shall be top maintainable for easy maintenance. LED street light shall use multiple LEDs to get sufficient light output from the luminaire. The LED street light shall be of Integral type incl one No of LED security light including Electronic driver of the same make and capacity. The input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED street light shall have power factor more than 0.95. Complete all as specified and directed.\nNotes:-\n1. Driver shall be potted antivibration type.\n2. LM-79 and LM-80 test report with 50,000 burning hours LED life from NABL lab shall be povided.\n3. CRI (Colou Rendring Index) of fixture shall be > 70.\n4. CCT (Colout Correlated Temprature of fixture shall be 5700K ± 300 K.\n5. System Lumen Efficacy shall be > 100Lm/W\n 266 Each
3 2.01 6. 10 KV separate Surge Protection shall be provided as a part of fitting.\n7. 5 years gurantee shall be provided by contractor suppoted by OEM covering all parts of luminaire. \n8. Lenses shall be Modular Type. \n9. PCB used shall be MC PCB type \n10. The defect liability period of LED light shall be 05 years from the certified date of completion & the Contractor shall replace / repair the defective fitting within 07 Days after handing over to Contractor for replacement / repair \n11. CA No shall be written on each fitting before installation.\n12. The name of manufacturer to be embossed on the fitting.\n13. The fittings shall have arrangement so that maintaince required, if any can be carried out from Top cover.
4 3 Supply and fixing in replacement single core FRLS insulated copper stranded cable of size 1.5 Sqmm for street light/Flood light passing through pole hole/GI Pipe /PVC conduit to junction box and connected electrically complete all as specified and directed 1596 RM
5 4 S&F fix as in repair/replacement of pole mounted street light factory fabricated Junction Box of size 300 x 160 x 250 mm of approved make and of appropriate size made out of 2 mm thick CRCA powder coated sheet including 63A, Three Phase four wire having four no aluminium Bus Bar including 6A SP MCB. The box shall have auto door lock facility with magnatic lock having box fixed on pole using necessary fixing arrangement such as clamps, nut, bolts and washer including taking down existing junction box of any description/type etc complete all as specified and directed. 80 Each
6 5 S&F inrepair/replacement, installation, connecting electrically and testing of Street light panel box complete with Astronomical timer, contactor rating 63 Amps including, MCB 63A TPN complete made out of CRCA sheet 1.6mm thick, powder coated having provision for Astronomical Timer, contactor, Toggle switch, SP MCBs and MCCBs etc. having self closing door lock complete with fixing clamps or mounting arrangement complete all as specified and as required at site including taking out existing U/S street light switch any type and size. 4 Each
7 6 M&L for scraping of old paint form the steel tubular pole 9 mtr height with out removing accessories and preparation of surfaces for repainting. Repainting the pole with one coat of 30 cm alternative green and white strips of each upto 1.5 mtr height using synthetic enamel paint. Repainting the remaining pole and iron part i.e U clamps, channels etc above 1.5 mtr height by applying Two coat of aluminium paint, including wiring letters or figure (Block, Roman Italic or Indian) S/L Pole No. over yellow circle and Locations code not exceeding 30cm high, stop commas, short lines, dashes, hypens, brackets etc complete all as specified and directed by Engr-in-Charge all as required at site or directed 266 Each Job
8 7 S&F in replacement MCB single pole 240 volts, 'B' series upto 32 Amps with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed 112 Each
9 8 Excavation in trenches in any type of soil n exc 1.5 M in width and n. exc 1.5 M in depth and getting out all as required for laying of cables,Foundation filling of poles or stays, complete, all as specified and directed. 344.5 Cum
10 9 Excavation in trenches in any type of soil n exc 1.5 M in width exc 1.5M and not exc and 3.0 M in depth and getting out all as required for laying of cables,Foundation filling of poles or stays, complete, all as specified and directed. 1.5 Cum
11 10 Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, complete, all as specified and directed. 162 Cum
12 11 Removing excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete, all as specified and as directed. 184 Cum
13 12 M&L sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable, complete, all as specified and as directed. \n(Note: Punned thickness shall be measured & paid) 138 Cum
14 13 M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified and directed 13600 Each
15 14 M&L for GI tubing light grade 50mm bore cut to size and fixed along the pole for protection of cable including 2 Nos clamp of size 25 x 4mm nut, bolts and washers complete, all as specified and directed. 217 RM
16 15 Material & Labour in replacement for LT cable 1100 volts grade heavy duty,XLPE insulated , armoured heavy duty electric cable , with aluminium conductor of 10 Sqmm x 2 core including laying in trenches or fixed to wall/pole or passing through pipe taking out cable from trenches or wall/ pole or pipe of any size, complete all as specified and directed by Engr In Charge. 325 RM
17 16 All as per above Srl. Item No. 15 but of size 35 Sqmm X 3.5 core. 1325 RM
18 17 All as per above Srl. Item No. 15 but of size 70 Sqmm X 3.5 core. 250 RM
19 18 All as per above Srl. Item No. 15 but of size 95 Sqmm X 3.5 core. 345 RM
20 19 M&L for Cable end termination out door, heat shrinkable type joint suitable for XLPE cable of size 25 Sqmm to 50 sqmm 3½ core with working voltage 1100 volts with jointing material and accessories including testing etc complete all as specified and directed \nMake: Denson/ M Seal / 3 M / Raychem / Cabseal 4 Each
21 20 M&Lfor Cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3½ core XLPE armoured aluminium conductor cable of size 25 Sqmm to 50 sqmm with working voltage 1100 volts complete all as specified and direced Make: Denson/ M Seal / 3 M / Raychem / Cabseal 4 Each
22 21 Supply, installation, commissioning and testing of factory made, CPRI approved totally enclosed outdoor type LT Panel weldless cubical Kiosk in modular bolted construction type dust and vermin proof floor mounted type (IP-65 degree of protection ) made out of 3 mm thick CRCA sheet of recommended size.All sheet metal parts shall be powder coated. The panel having both side opening door with locking arrangement.all doors fixed with aluminium hinges with suitable size nut bolts and shall have flexible fixing of each switchgear and control gear compartment with cable alley tray of size not less than 30 cm. duly powder coated, bus bar 400 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply ,hibling , cable entry boxes , cable gland and LT panel shall be mounted on iron angle frame made out of 50 X 50X 6 mm frame with 4 No. legs size not less than 45 cms fixed with nut bolts of suitable size (bottom portion of the panel) , grouted by using foundation PCC (1:2:4) type B-1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I , suitable for and including the following .\nMake of panel Tricolite/milestone/DVEPL/Power System & Control. 2 Each Job
23 21.01 (i) MCCB 4 pole 415 volts 350 amp rating microprecesser based . Thermal magnetic release with rupturing capacªity 50 KA - 01 No as incomer , Make-Legrand (DPX3) ,Siemens (3VL)/Schneider (NSX)
24 21.02 (ii) MCCB 4 pole 415 volts with thermal based release rupturing cap 36 KA, 125 amps - 04 Nos for outgoing , Make-Legrand (DPX3) ,Siemens (3VL) / Schneider (NSX)
25 21.03 (iii) MCCB 3 pole 415 volts with microprocesser release rupturing cap 25 KA, 63 amps - 02 Nos for outgoing , Make-Legrand (DPX3) ,Siemens(3VL) / Schneider (NSX)
26 21.04 (iv) Indicator set RYB -01 Set of 3 pcs only Make- L & T/ Legrand/ Siemens
27 21.05 (v) Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio Make- Schneider cat no. 30002567 or eqvivalent model in L&T / Legrand
28 21.06 (vi) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction, complete, all as required and as directed.\n
29 22 Trimming up of tree branches upto 5 M all around HT overhead lines from Bana to Khetralpal removing cut branches from site complete all as specified directed.\nNote : (i) The overhead lines will be kept clear form all trees by trimming of tree branches with 5 M all around the line. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department accordingly. The trimming work shall be commenced once it is permitted by AGE in writing (ii) Total length of line from supply point to load end will be measured as one span for the purpose of payment, irrespective of the No of trees required to be trimmed. No claim whatsoever shall be entertained by the deptt at later stage.\n(The approximate length of one span is 30 to 45 m)\n 45 Each Span
30 23 S&F in replacement of Cable route indicator made of CI 100mm dia welded and fitted with MS angle Iron 40 x 40x 6 mm, 45 Cm long. The angle shall be grouted in PCC block 1:3:6 type C-1 of size 150 x 150 x 150mm. The CI round shall be embossed with the work “MES LT Cables” complete all as specified and as directed.\n 60 Each
31 24 Material & Labour for PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed 10.8 Cum
32 25 Material & Labour for PCC 1:3:6 (nominal mix) type C-1 (using 40mm graded crushed stone aggregates) as in coping of pole complete all as specified and directed 4.5 Cum
33 26 S&F in replacement Earthing complete with galvanised steel earth plate electrode 600mmx600mm thickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electric plate No 3 of SSR Pt-I connected to earth test point/MCB DBs all as specified and indicated compete with funnel, charcoal, dust, salt etc and GI protection pipe, medium grade 15mm bore and GI watering pipe 20mm bore light grade, 40mm thick precast RCC M-15 (nomial mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x4mm frame for cover, PCC M-15 (Nominal mix) pit, excavation and earth work in any type of soil and connected including test point, complete, all as specified & directed.\nNotes: \n1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in the unit rate quoted by the contractor.\n2. Earth filling shall be done by vegitable soil.\n3. Soil should be free from stone, boulders, aggregate, gravels etc. 6 Each Set