Steel Industrials Kerala Limited has published Supply And Installation Of Passenger Lift , Air Conditioning , Generator For Additional Works To Auditorium Building In Pudussery Grama Panchayath , Palakkad District Supply And Installation Of Passenger Lift , Air Conditioning , Generator For Addit. Submission Date for this Tender is 20-10-2020. Passenger Lift Tenders in Pudussery Grama Panchayath, Palakkad District Kerala. Bidders can get complete Tender details and download the document.
Name of Work: Supply and Installation of Passenger Lift ,Air Conditioning ,Generator for Additional works to Auditorium Building in Pudussery Grama Panchayath, Palakkad District | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Supplying and providing Passenger elevator Lift PW108/06-19 type AMonospace,speed 0.6m/s, 2 stop 2 openings(capacity- 8 person 544kg, 1.77x1.89 size, centre opening type, stainless steel frame closure, Car dimension 1.1 m width x 1.3m length x 2.2m height ) \nCar design :Stainless Steel\nCar panel Finish :Stainless steel Hairline AISI441\nHandrail :Round Bend Handrail Stainless steel at Rear Wall\nCeiling & Lighting :Integrated Roof RL75 Stainless Steel Pyramid Lighting LED\nFlooring :3 mm PVC- Pattern Dark Grey Marble /pattern\nCar door finish :Stainless steel Hairline AISI441 \nCar operating panel :1 Full Height Stainless Steel Face Plate Silver brushed StSt Square surface mounted Buttons KDS90\nLanding Signalization :Stainless steel 7 segment display Flush mounted ST4-Silver brushed. Both arrow up and down button KDS90 approved branded quality certifications required, all works to be done by the direction of engineer in charge\n\n | BI01010001010000000000000515BI0100001113 | 1 | Nos |
2 | 2 | SUPPLY AND INSTALLATION OF AIR CONDITIONING SYSTEM Supply, Installation, Testing & Commissioning of Blue Star Ductable Split Air Conditioning Units with scroll type compressor along with first charge of refrigerant complete with all components and controls ,electrical cabling ,canvas connections as required.Each unit shall comprise of seperate indoor and outdoor unit of 11TR capacity,with controls with scroll compressor. | BI01010001010000000000000515BI0100001114 | 4 | nos |
3 | 3 | Supply, Installation, Testing & Commissioning of Blue Star Ductable Split Air Conditioning Units with scroll type compressor along with first charge of refrigerant complete with all components and controls ,electrical cabling ,canvas connections as required.Each unit shall comprise of seperate indoor and outdoor unit of 8.5TR capacity,with controls. | BI01010001010000000000000515BI0100001115 | 1 | nos |
4 | 4 | SITC of refrigerant piping (Suction & Discharge) with standard\ninsulation with copper pipe - 1.125 inch dia | BI01010001010000000000000515BI0100001116 | 15 | m |
5 | 5 | SITC of refrigerant piping (Suction & Discharge) with standard\ninsulation with copper pipe - 1 3/8 inch dia | BI01010001010000000000000515BI0100001117 | 15 | m |
6 | 6 | SITC of refrigerant piping (Suction & Discharge) with standard\ninsulation with copper pipe - 7/8 inch dia | BI01010001010000000000000515BI0100001118 | 30 | m |
7 | 7 | Supply,Installation,testing ,termination and commissioning of\ntransmission cable RR or POLYCAB - 11 TR Ductable Split Air Conditioning Unit | BI01010001010000000000000515BI0100001119 | 60 | m |
8 | 8 | SITC of Hard PVC drain piping. Drain Piping with necessary\nclamps, supports, hangers, and fitings such as bend, reducers, tees,\nreducers, etc. with sufficient insulation: complete in all respects. | BI01010001010000000000000515BI0100001120 | 40 | m |
9 | 9 | Ducting \nSupply, fabrication, installation, testing of G I rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per IS 655,IS226,IS277,IS2003 including suspension and supporting arrangement for plenum, duct etc. as required. ducts shall be supported by 10mm MS rods and 40x40x3 MS angles .The duct supports shall be at a distance of not more than 2000mm.The ms ros shall be hung by dash fasteners fixed to the ceiling slab -24 Gauge GI sheet | BI01010001010000000000000515BI0100001121 | 280 | sqm |
10 | 10 | Ducting \nSupply, fabrication, installation, testing of G I rectangular ducts,\ncomplete with all fittings such as tee, bends, special off shoots,\ninspection doors, transformation pieces etc. as reuired as per IS 655,226,277,2003\nincluding suspension and supporting arrangement for plenum, duct etc.\nas required. ducts shall be supported by 10mm MS rods and 40x40x3 MS angles .The duct supports shall be at a distance of not more than 2000mm.The ms ros shall be hung by dash fasteners fixed to the ceiling slab - 22 Gauge GI sheet | BI01010001010000000000000515BI0100001122 | 30 | sqm |
11 | 11 | Duct insulation and lining \nThermal insulation of ducts using closed cell Nitrile 9mm thick nitrile rubber | BI01010001010000000000000515BI0100001123 | 245 | sqm |
12 | 12 | Accoustic insulation and lining of ducts using suitable adhesive open cell nitrile 10mm thick nitrile rubber. | BI01010001010000000000000515BI0100001124 | 65 | sqm |
13 | 13 | supply and installation of air grill using powder coated(16gauge or 18gauge) ,all supply air diffusers /grills shall be complete with volume control dampers. | BI01010001010000000000000515BI0100001125 | 10 | sqm |
14 | 14 | canvas connections | BI01010001010000000000000515BI0100001126 | 5 | nos |
15 | 15 | Supply and Installation of 125 KVA Generator GREAVES POWER Genset Model GPWII-PII-125, 125kVA/100kW Genset comprising of GREAVES Engine Model:4G11TAG26 Radiator cooled, Turbocharged & After cooled Diesel engine developing 155.0 BHP at 1500 RPM coupled to 3Phase, 125KVA, 50Hz, 415Volts, 0.8PF, IP23Protection, Class H insulation MECCALTE/LEROY SOMER/Equivalent Alternator with 350Ltr integral fuel tank, Battery, E haust Silencer, Standard control Panel and Acoustic Enclosure as per CPCB II Norms Sound level- 75Db(A) at one meter from enclosure surface in free and includes all labour charges and transportation charges.all complete. | BI01010001010000000000000515BI0100001127 | 1 | nos |
16 | 15.1 | 150 sqmm UG-AL Cable Running/Meter | BI01010001010000000000000515BI0100001128 | 80 | m |
17 | 15.2 | Generator Complete Earthing Work including 2.5 meter pit. | BI01010001010000000000000515BI0100001129 | 3 | nos |
18 | 15.3 | 25X3 mm copper Strip Running /Meter | BI01010001010000000000000515BI0100001130 | 54 | m |
19 | 15.4 | Cable Gland & Termination | BI01010001010000000000000515BI0100001131 | 6 | nos |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail