| 1 | 1 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1500mm. \n(Ref. Page no-1, Item No-2 of PWD Sch. of Rates 2017). | BI01010001010000000000000515BI0100001113 | 110 | %Cum |
|---|
| 2 | 2 | Cement concrete with graded stone ballast (40 mm size excluding\nshuttering)\nIn ground floor\n(A) [Pakur Variety] a) 1:3:6 proportion\n(Ref. Page no-26,Item No-10 of PWD Sch. of Rates 2017).\n | BI01010001010000000000000515BI0100001114 | 10.5 | cum |
|---|
| 3 | 3 | Filling in foundation or plinth by (B) Do - by fine sand inl ayers not exceeding 150 mm as directed and\nconsolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)(Ref. Page no-2,Item No-4 of PWD Sch. of Rates 2017). | BI01010001010000000000000515BI0100001115 | 135 | cum |
|---|
| 4 | 4 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.\n(Ref. Page no-43,Item No-40,(a),of PWD Sch. of Rates 2017). | BI01010001010000000000000515BI0100001116 | 9.5 | MT |
|---|
| 5 | 5 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)\na) For25 mm to 30 mm thick wooden shuttering without staging in foundation.\n(Ref. Page no-42 Item No -36 of PWD Sch. of Rates 2017). | BI01010001010000000000000515BI0100001117 | 800 | SQM |
|---|
| 6 | 6 | Ordinary Cement Concrete (mix1:1.5:3) with graded stonechips (20 mm. size) excluding shuttering and reinforcement, if any, in ground floor, Pakur Variety.\n(Ref. Page no-26,Item No-10 of PWD Sch. of Rates 2017). | BI01010001010000000000000515BI0100001119 | 117 | Cum |
|---|