}

( Retender ) Tvm Dp- 2020-21 - Pro No . 947- Supply And Installation Of Equipments For Modern Slaughter House In Karavaram Please Refer Tender Documents, Karavaram-Kerala

Local Self Government Department has published ( Retender ) Tvm Dp- 2020-21 - Pro No . 947- Supply And Installation Of Equipments For Modern Slaughter House In Karavaram Please Refer Tender Documents. Submission Date for this Tender is 22-10-2020. Bolts Tenders in Karavaram Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

25692737
Corrigendum : ( Retender ) Tvm Dp- 2020-21 - Pro No . 947- Supply And Installation Of Equipments For Modern Slaughter House In Karavaram Please Refer Tender Documents
Tender
Indian
Kerala
Karavaram
22-10-2020

Tender Details

( Retender ) Tvm Dp- 2020-21 - Pro No . 947- Supply And Installation Of Equipments For Modern Slaughter House In Karavaram Please Refer Tender Documents , Electrification , 90 . 2 . 1 . 7 : Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988 , Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1 . 00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade , Including Providing Switch Board Main And Continuous Earthing With No . 14 Swg Bare Copper , Required Quantity Of Copper Earth Socket , Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes , Modular Type Front Plates ( White ) Etc . Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall , Colour Washing Etc . Complete . All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties , Tie Mounts Etc As Required . ( Rohs Compliant Modular Accessories ) . Independent Plug - Short Point , 90 . 2 . 1 . 3 : Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988 , Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1 . 00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade , Including Providing Switch Board Main And Continuous Earthing With No . 14 Swg Bare Copper , Required Quantity Of Copper Earth Socket , Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes , Modular Type Front Plates ( White ) Etc . Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall , Colour Washing Etc . Complete . All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties , Tie Mounts Etc As Required . ( Rohs Compliant Modular Accessories ) . , 1 . 32 : Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess , Including Providing And Fixing 6 Pin 5/6 & 15/16 Amps Modular Socket Outlet And 15/16 Amps Modular Switch , Connection Etc . As Required . , 90 . 3 . 18 . 2 : Supply , Fabrication , Conveyance And Fixing The Following Sizes Of B Class Gi Pipe Bent To Shape / Cut And Welded To Shape And Fixing The Same To Wall / Parapet Using Clamps As Noted Along With Each Size , Painting With 2 Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromate Primer , Making Good The Damages , Colour Washing Etc As Required . , 90 . 15 . 4 . 2 : Supply Conveyance , Installation , Testing And Commissioning Of 36/40W Led Street Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0 . 95 At Full Load , Internal Surge Protection Up To 8 Kv , And Aluminium Pressure Die-Cast Powder Coated Housing , Acrylic Cover Complete With Thd Less Than 10% , Power Factor Greater Than 0 . 98 , Rohs Compliant , Duly Wired Up For Use On 230 V Ac Supply . Driver Compartment Should Be Seperatly Accessible For Maintenance ( Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer ) , 90 . 15 . 4 . 11 : Supply Conveyance , Installation , Testing And Commissioning Of 200W Led Flood Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0 . 95 At Full Load , Internal Surge Protection Up To 8 Kv , And Aluminium Pressure Die-Cast Powder Coated Housing , Acrylic Cover Complete With Thd Less Than 10% , Power Factor Greater Than 0 . 98 , Rohs Compliant , Duly Wired Up For Use On 230 V Ac Supply . Driver Compartment Should Be Seperatly Accessible For Maintenance ( Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer ) , 2 . 10 . 1 : Supplying And Fixing 5 Amps To 32 Amps Rating , 240/415 Volts , C Curve , Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . Single Pole , 2 . 10 . 4 : Supplying And Fixing 5 Amps To 32 Amps Rating , 240/415 Volts , C Curve , Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . Triple Pole , 2 . 13 . 2 : Supplying And Fixing Following Rating , Four Pole , 415 Volts , Isolator In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . 63 Amps , 2 . 13 . 3 : Supplying And Fixing Following Rating , Four Pole , 415 Volts , Isolator In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . 100 Amps , 2 . 15 . 2 : Supplying And Fixing Following Rating , Four Pole , ( Three Phase And Neutral ) , 415 Volts , Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . 40 Amps , 2 . 2 . 14 : Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel , Making Connections , Etc . As Required . 125 Amp , 36 Ka , Od848835/2020_2021 : Supply And Installation Of Switch Gear Units In Sheet Steel Enclosure Complete With Handle Assembly , Door Interlock And Pad Locking Arrangement Of The Following Ratings On Existing Angle Iron Frame Work Or Directly On Wall Using Necessary Bolts &Amp; Nuts , Fixing The Unit To Wall , Making Good The Damages , Colour Washing Etc . Including Giving Necessary Connections As Required . ≪Br≫125A , 415V , 50Hz , Ac23 A Duty , 4 Pole On Load Changeover Switch Disconnector , 90 . 11 . 1 . 11 : Supply And Installation Of Sheet Steel , Phosphatised And Painted , Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar , Neutral Link , Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc . Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages , Colour Washing Etc . As Required , 90 . 11 . 1 . 12 : Supply And Installation Of Sheet Steel , Phosphatised And Painted , Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar , Neutral Link , Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc . Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages , Colour Washing Etc . As Required , 90 . 11 . 1 . 19 : Supply And Installation Of Sheet Steel , Phosphatised And Painted , Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar , Neutral Link , Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc . Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages , Colour Washing Etc . As Required , 1 . 21 . 1 : Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required . 20 Mm , 1 . 21 . 2 : Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Rec

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 21-10-2020 Date extension - (Retender) TVM DP- 2020-21 - Pro no. 947- Supply and installation of equipments for Modern slaughter house in Karavaram Date 22-10-2020

Key Value

Document Fees
INR 2760 /-
EMD
INR 50000.0 /-
Tender Value
INR 84.68 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail