Public Administrative Department Government Departments Closing in 0 days TDR #25692737

( Retender ) Tvm Dp- 2020-21 - Pro No . 947- Supply And Installation Of Equipments For Modern Slaughter House In Karavaram Please Refer Tender Documents

Issued by Government Departments · Karavaram, Kerala
Tender Value
84.68 Lakhs
Estimated cost
Bid Submission
22 Oct 2020
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
2760
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Karavaram → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

( Retender ) Tvm Dp- 2020-21 - Pro No . 947- Supply And Installation Of Equipments For Modern Slaughter House In Karavaram Please Refer Tender Documents , Electrification , 90 . 2 . 1 . 7 : Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988 , Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1 . 00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade , Including Providing Switch Board Main And Continuous Earthing With No . 14 Swg Bare Copper , Required Quantity Of Copper Earth Socket , Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes , Modular Type Front Plates ( White ) Etc . Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall , Colour Washing Etc . Complete . All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties , Tie Mounts Etc As Required . ( Rohs Compliant Modular Accessories ) . Independent Plug - Short Point , 90 . 2 . 1 . 3 : Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988 , Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1 . 00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade , Including Providing Switch Board Main And Continuous Earthing With No . 14 Swg Bare Copper , Required Quantity Of Copper Earth Socket , Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes , Modular Type Front Plates ( White ) Etc . Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall , Colour Washing Etc . Complete . All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties , Tie Mounts Etc As Required . ( Rohs Compliant Modular Accessories ) . , 1 . 32 : Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess , Including Providing And Fixing 6 Pin 5/6 & 15/16 Amps Modular Socket Outlet And 15/16 Amps Modular Switch , Connection Etc . As Required . , 90 . 3 . 18 . 2 : Supply , Fabrication , Conveyance And Fixing The Following Sizes Of B Class Gi Pipe Bent To Shape / Cut And Welded To Shape And Fixing The Same To Wall / Parapet Using Clamps As Noted Along With Each Size , Painting With 2 Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromate Primer , Making Good The Damages , Colour Washing Etc As Required . , 90 . 15 . 4 . 2 : Supply Conveyance , Installation , Testing And Commissioning Of 36/40W Led Street Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0 . 95 At Full Load , Internal Surge Protection Up To 8 Kv , And Aluminium Pressure Die-Cast Powder Coated Housing , Acrylic Cover Complete With Thd Less Than 10% , Power Factor Greater Than 0 . 98 , Rohs Compliant , Duly Wired Up For Use On 230 V Ac Supply . Driver Compartment Should Be Seperatly Accessible For Maintenance ( Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer ) , 90 . 15 . 4 . 11 : Supply Conveyance , Installation , Testing And Commissioning Of 200W Led Flood Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0 . 95 At Full Load , Internal Surge Protection Up To 8 Kv , And Aluminium Pressure Die-Cast Powder Coated Housing , Acrylic Cover Complete With Thd Less Than 10% , Power Factor Greater Than 0 . 98 , Rohs Compliant , Duly Wired Up For Use On 230 V Ac Supply . Driver Compartment Should Be Seperatly Accessible For Maintenance ( Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer ) , 2 . 10 . 1 : Supplying And Fixing 5 Amps To 32 Amps Rating , 240/415 Volts , C Curve , Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . Single Pole , 2 . 10 . 4 : Supplying And Fixing 5 Amps To 32 Amps Rating , 240/415 Volts , C Curve , Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . Triple Pole , 2 . 13 . 2 : Supplying And Fixing Following Rating , Four Pole , 415 Volts , Isolator In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . 63 Amps , 2 . 13 . 3 : Supplying And Fixing Following Rating , Four Pole , 415 Volts , Isolator In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . 100 Amps , 2 . 15 . 2 : Supplying And Fixing Following Rating , Four Pole , ( Three Phase And Neutral ) , 415 Volts , Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . 40 Amps , 2 . 2 . 14 : Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel , Making Connections , Etc . As Required . 125 Amp , 36 Ka , Od848835/2020_2021 : Supply And Installation Of Switch Gear Units In Sheet Steel Enclosure Complete With Handle Assembly , Door Interlock And Pad Locking Arrangement Of The Following Ratings On Existing Angle Iron Frame Work Or Directly On Wall Using Necessary Bolts &Amp; Nuts , Fixing The Unit To Wall , Making Good The Damages , Colour Washing Etc . Including Giving Necessary Connections As Required . ≪Br≫125A , 415V , 50Hz , Ac23 A Duty , 4 Pole On Load Changeover Switch Disconnector , 90 . 11 . 1 . 11 : Supply And Installation Of Sheet Steel , Phosphatised And Painted , Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar , Neutral Link , Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc . Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages , Colour Washing Etc . As Required , 90 . 11 . 1 . 12 : Supply And Installation Of Sheet Steel , Phosphatised And Painted , Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar , Neutral Link , Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc . Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages , Colour Washing Etc . As Required , 90 . 11 . 1 . 19 : Supply And Installation Of Sheet Steel , Phosphatised And Painted , Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar , Neutral Link , Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc . Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages , Colour Washing Etc . As Required , 1 . 21 . 1 : Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required . 20 Mm , 1 . 21 . 2 : Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Rec

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 21-Oct-2020 Date extension - (Retender) TVM DP- 2020-21 - Pro no. 947- Supply and installation of equipments for Modern slaughter house in Karavaram Date 22-Oct-2020

BOQ

Work Name:(Retender) ELECTRIFICATION OF NEWLY CONSTRUCTED INDOOR STADIUM AT NEERUVILA IN OTTUR GP
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11ELECTRIFICATIONBI01010001010000000000000515BI0100001113
21.00190.2.1.7 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short pointBI01010001010000000000000515BI010000111410each
31.00290.2.1.3 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).BI01010001010000000000000515BI01000011152point
41.0031.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.BI01010001010000000000000515BI01000011161each
51.00490.3.18.2 : Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.BI01010001010000000000000515BI01000011172metre
61.00590.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)BI01010001010000000000000515BI01000011182each
71.00690.15.4.11 : Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)BI01010001010000000000000515BI01000011199each
81.0072.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single poleBI01010001010000000000000515BI010000112030each
91.0082.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple poleBI01010001010000000000000515BI01000011212each
101.0092.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 ampsBI01010001010000000000000515BI01000011222each
111.012.13.3 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 ampsBI01010001010000000000000515BI01000011231each
121.0112.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual \n current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 ampsBI01010001010000000000000515BI01000011242each
131.0122.2.14 : Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp, 36 KABI01010001010000000000000515BI01000011251each
141.013od848835/2020_2021 : Supply and installation of switch gear units in sheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement of the following ratings on existing angle iron frame work or directly on wall using necessary bolts & nuts, fixing the unit to wall, making good the damages, colour washing etc. including giving necessary connections as required.<br>125A, 415V, 50Hz, AC23 A duty, 4 Pole On Load Changeover Switch DisconnectorBI01010001010000000000000515BI01000011261no
151.01490.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as requiredBI01010001010000000000000515BI01000011271each
161.01590.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as requiredBI01010001010000000000000515BI01000011281each
171.01690.11.1.19 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as requiredBI01010001010000000000000515BI01000011291each
181.0171.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mmBI01010001010000000000000515BI0100001130720metre
191.0181.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mmBI01010001010000000000000515BI0100001131300metre
201.0191.17.1 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mmBI01010001010000000000000515BI01000011322000metre
211.021.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mmBI01010001010000000000000515BI0100001133870metre
221.0211.17.11 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mmBI01010001010000000000000515BI01000011341910metre
231.0221.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of CableBI01010001010000000000000515BI0100001135625metre
241.02390.6.4.2 : Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.BI01010001010000000000000515BI0100001136600metre
251.02490.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.BI01010001010000000000000515BI010000113730metre
261.02590.12.7.44 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.BI01010001010000000000000515BI010000113830metre
271.0269.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 1/2 X 50 sq. mm (35mm)BI01010001010000000000000515BI01000011392set
281.0279.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 16 sq. mm (28mm)BI01010001010000000000000515BI01000011404set
291.0285.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as requiredBI01010001010000000000000515BI01000011412set
301.0295.10 : Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.BI01010001010000000000000515BI01000011421metre
311.0390.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as requiredBI01010001010000000000000515BI010000114370metre
321.03190.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.BI01010001010000000000000515BI01000011448each
331.032od845062/2020_2021 : Fabrication,supply& installation of dust and vermin proof,wall<br>mouting,thermoplastic meter box of following size suitable for fixing KSEB meter,fuse units,CT etc,hinged door construction for the front side with compartments if necessary,providing vision panel for the meter compartment, knock out for cable entry and exit.<br>600 x 300 x 214BI01010001010000000000000515BI01000011451no
341.033od848833/2020_2021 : Supply and fixing 100 A, 2 Way neutral links mounted on DMC/SMC baseBI01010001010000000000000515BI01000011461no
351.034od848834/2020_2021 : Supply and fixing 125 A, HRC Fuse Base with HRC Fuse linkBI01010001010000000000000515BI01000011473no

AI Tender Summary

OUR REF NO 25692737
AUTHORITY Government Departments
TENDER VALUE 84.68 Lakhs
LAST DATE 22-10-2020
Authority
Authority Name Local Self Government Department
Work Description ( Retender ) Tvm Dp- 2020-21 - Pro No . 947- Supply And Installation Of Equipments For Modern Slaughter House In Karavaram Please Refer Tender Documents , Electrification , 90 . 2 . 1 . 7 : Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988 , Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1 . 00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade , Including Providing Switch Board Main And Continuous Earthing With No . 14 Swg Bare Copper , Required Quantity Of Copper Earth Socket , Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes , Modular Type Front Plates ( White ) Etc . Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall , Colour Washing Etc . Complete . All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties , Tie Mounts Etc As Required . ( Rohs Compliant Modular Accessories ) . Independent Plug - Short Point , 90 . 2 . 1 . 3 : Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988 , Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1 . 00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade , Including Providing Switch Board Main And Continuous Earthing With No . 14 Swg Bare Copper , Required Quantity Of Copper Earth Socket , Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes , Modular Type Front Plates ( White ) Etc . Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall , Colour Washing Etc . Complete . All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties , Tie Mounts Etc As Required . ( Rohs Compliant Modular Accessories ) . , 1 . 32 : Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess , Including Providing And Fixing 6 Pin 5/6 & 15/16 Amps Modular Socket Outlet And 15/16 Amps Modular Switch , Connection Etc . As Required . , 90 . 3 . 18 . 2 : Supply , Fabrication , Conveyance And Fixing The Following Sizes Of B Class Gi Pipe Bent To Shape / Cut And Welded To Shape And Fixing The Same To Wall / Parapet Using Clamps As Noted Along With Each Size , Painting With 2 Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromate Primer , Making Good The Damages , Colour Washing Etc As Required . , 90 . 15 . 4 . 2 : Supply Conveyance , Installation , Testing And Commissioning Of 36/40W Led Street Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0 . 95 At Full Load , Internal Surge Protection Up To 8 Kv , And Aluminium Pressure Die-Cast Powder Coated Housing , Acrylic Cover Complete With Thd Less Than 10% , Power Factor Greater Than 0 . 98 , Rohs Compliant , Duly Wired Up For Use On 230 V Ac Supply . Driver Compartment Should Be Seperatly Accessible For Maintenance ( Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer ) , 90 . 15 . 4 . 11 : Supply Conveyance , Installation , Testing And Commissioning Of 200W Led Flood Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0 . 95 At Full Load , Internal Surge Protection Up To 8 Kv , And Aluminium Pressure Die-Cast Powder Coated Housing , Acrylic Cover Complete With Thd Less Than 10% , Power Factor Greater Than 0 . 98 , Rohs Compliant , Duly Wired Up For Use On 230 V Ac Supply . Driver Compartment Should Be Seperatly Accessible For Maintenance ( Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer ) , 2 . 10 . 1 : Supplying And Fixing 5 Amps To 32 Amps Rating , 240/415 Volts , C Curve , Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . Single Pole , 2 . 10 . 4 : Supplying And Fixing 5 Amps To 32 Amps Rating , 240/415 Volts , C Curve , Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . Triple Pole , 2 . 13 . 2 : Supplying And Fixing Following Rating , Four Pole , 415 Volts , Isolator In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . 63 Amps , 2 . 13 . 3 : Supplying And Fixing Following Rating , Four Pole , 415 Volts , Isolator In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . 100 Amps , 2 . 15 . 2 : Supplying And Fixing Following Rating , Four Pole , ( Three Phase And Neutral ) , 415 Volts , Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . 40 Amps , 2 . 2 . 14 : Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel , Making Connections , Etc . As Required . 125 Amp , 36 Ka , Od848835/2020_2021 : Supply And Installation Of Switch Gear Units In Sheet Steel Enclosure Complete With Handle Assembly , Door Interlock And Pad Locking Arrangement Of The Following Ratings On Existing Angle Iron Frame Work Or Directly On Wall Using Necessary Bolts &Amp; Nuts , Fixing The Unit To Wall , Making Good The Damages , Colour Washing Etc . Including Giving Necessary Connections As Required . ≪Br≫125A , 415V , 50Hz , Ac23 A Duty , 4 Pole On Load Changeover Switch Disconnector , 90 . 11 . 1 . 11 : Supply And Installation Of Sheet Steel , Phosphatised And Painted , Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar , Neutral Link , Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc . Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages , Colour Washing Etc . As Required , 90 . 11 . 1 . 12 : Supply And Installation Of Sheet Steel , Phosphatised And Painted , Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar , Neutral Link , Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc . Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages , Colour Washing Etc . As Required , 90 . 11 . 1 . 19 : Supply And Installation Of Sheet Steel , Phosphatised And Painted , Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar , Neutral Link , Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc . Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages , Colour Washing Etc . As Required , 1 . 21 . 1 : Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required . 20 Mm , 1 . 21 . 2 : Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Rec
Basic Detail
Tender No e-27/EE/LSGD/2020-21
Bidding Type Tender
Location
City Karavaram
State Kerala
Key Dates
Publish Date 21 Oct 2020
Submission Date 22 Oct 2020
Open Date 23 Oct 2020
Finance
Tender Value 84.68 Lakhs
Tender Fee 2760
EMD 50000
Exemption Not Available
Document List
E7A6B35C-CAD2-46CE-9276-D72267A09954.html
DECLARATION.pdf
Tendernotice_1.pdf
AEEPreliminaryAgreement.pdf.pdf
epaymentform.pdf
BOQ_556367.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 21, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2020
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 22, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 23, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

E7A6B35C-CAD2-46CE-9276-D72267A09954.html

pdf

DECLARATION.pdf

pdf

Tendernotice_1.pdf

pdf

AEEPreliminaryAgreement.pdf.pdf

pdf

epaymentform.pdf

xls

BOQ_556367.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders