Military Engineer Services-MES has published Repair And Maintenance Of Central Package Type Ac , Window/Split Type Ac , Desert Cooler And All Other Summer Appliances At Morar Cantt Under Ge Gwalior. Submission Date for this Tender is 29-10-2020. Air Conditioner Tenders in Garrison Engineer Gwalior Madhya Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: REPAIR AND MAINT OF CENTRAL AND PACKAGE AC, WINDOW/SPLIT TYPE AC, DESERT COOLERS AND ALL OTHER SUMMER APPLIANCES AT MORAR CANTT UNDER GE GWALIOR. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Dismantling and taking out the existing old unserviceable compressor hermetically/rotary sealed unit of any make from window type AC and S&F New compressor suitable for window AC of capacity 1.5 Ton complete all as specified and directed by Engineer in Charge. Make Godrej/LG/Samsung/Vidiocon/Hitachi/Carrier/Kirloskar | 5 | Each Job | |
2 | 2 | All as per Srl item No.1 here in before but compressor suitable for window AC of capacity 2.0 Ton complete all as specified and directed by Engineer in Charge. Make Godrej/LG/Samsung/Videocon/Hitachi/Carrier/Kirloskar | 3 | Each Job | |
3 | 3 | Dismantling and taking out the existing old unserviceable compressor hermetically/rotary sealed unit of any make from split type AC and S&F New compressor suitable for Split AC of capacity 1.5 Ton complete all as specified and directed by Engineer in Charge.Make Godrej/LG/Samsung/Videocon/Hitachi/Carrier/Kirloskar | 5 | Each Job | |
4 | 4 | All as per Srl item No.3 here in before but compressor suitable for Split AC of capacity 2.0 Ton complete all as specified and directed by Engineer in Charge.Make Godrej/LG/Samsung/Videocon/Hitachi/Carrier/Kirloskar | 3 | Each Job | |
5 | 5 | All as per Srl item No.3 here in before but compressor suitable for Split AC of capacity 3.0 Ton complete all as specified and directed by Engineer in Charge. Make Godrej/LG/Samsung/Videocon/Hitachi/Carrier/Kirloskar | 2 | Each Job | |
6 | 6 | M&L for testing leakage in system Window type Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system complete all as specified and directed by Engineer in Charge | 10 | Each Job | |
7 | 7 | All as per item No 6 here-in-before but Air conditioner of 2 ton capacity complete all as specified and directed by Engineer in Charge | 5 | Each Job | |
8 | 8 | M&L for testing leakage in system Split type Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system complete all as specified and directed by Engineer in Charge | 10 | Each Job | |
9 | 9 | All as per item No 8 here-in-before but Split type Air conditioner of 2.0 ton capacity complete all as specified and directed by Engineer in Charge | 5 | Each Job | |
10 | 10 | All as per item No 8 here-in-before but Split type Air conditioner of 3.00 ton capacity complete all as specified and directed by Engineer in Charge | 3 | Each Job | |
11 | 11 | M&L for servicing of Air conditioning of any capacity including air Filter Cleaning, Condenser and Evaporator coil Cleaning, insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water complete all as specified and directed.Note:- (i) Quoted rate is deemed to be included in minor requirement such as insulation tape, screws, small pieces of wires,plug top etc (ii). Spare parts & refrigerant gas shall be measured and paid separately in relevent item here-in-after. | 105 | Each Job | |
12 | 12 | Supply only following parts for repair of air conditioning:- | |||
13 | 13 | Starting capacitor of capacity 80/100 MFD | 15 | Each | |
14 | 14 | Starting capacitor of capacity 100/120 MFD | 5 | Each | |
15 | 15 | Condenser capacity of 5/6 MFD | 10 | Each | |
16 | 16 | Condenser capacity of 10 MFD | 10 | Each | |
17 | 17 | Condenser capacity of 36 MFD | 50 | Each | |
18 | 18 | Condenser capacity of 45 MFD | 5 | Each | |
19 | 19 | Condenser capacity of 50 MFD | 5 | Each | |
20 | 20 | Condenser capacity of 55 MFD | 5 | Each | |
21 | 21 | Heating Coil suitable for 1.5 Ton Capacity Window AC | 4 | Each | |
22 | 22 | Heating Coil suitable for 2.0Ton Capacity Window AC | 3 | Each | |
23 | 23 | Heating Coil suitable for 1.5 Ton Capacity Split AC | 5 | Each | |
24 | 24 | Heating Coil suitable for 2.0 Ton Capacity Split AC | 3 | Each | |
25 | 25 | Cooling Coil suitable for 1.5 Ton Capacity Window AC | 4 | Each | |
26 | 26 | Cooling Coil suitable for 2.0Ton Capacity Window AC | 3 | Each | |
27 | 27 | Cooling Coil suitable for 1.5 Ton Capacity Split AC | 8 | Each | |
28 | 28 | Cooling Coil suitable for 2.0 Ton Capacity Split AC | 3 | Each | |
29 | 29 | Cooling Coil suitable for 3.0 Ton Capacity Split AC | 2 | Each | |
30 | 30 | Swing motor suitable for 1.5 Ton Capacity Window type Air Conditioner. | 2 | Each | |
31 | 31 | Swing motor suitable for 2.0 Ton Capacity Window type Air Conditioner | 2 | Each | |
32 | 32 | Swing motor suitable for 1.5 Ton Capacity Split type Air Conditioner | 5 | Each | |
33 | 33 | Swing motor suitable for 2.0 Ton Capacity Split type Air Conditioner | 3 | Each | |
34 | 34 | Swing motor suitable for 3.0 Ton Capacity Split type Air Conditioner | 2 | Each | |
35 | 35 | Over load relay suitable for 1.5/2.0 Ton Window type AC | 4 | Each | |
36 | 36 | Over load relay suitable for 1.5/2.0 Ton Split type AC | 5 | Each | |
37 | 37 | PVC Front gril suitable for Window type AC of any Make suitable for 1.5/2.0Ton window AC | 5 | Each | |
38 | 38 | Electric blower motor suitable for 1.5 Ton Capacity Window type AC | 8 | Each | |
39 | 39 | Electric blower motor suitable for 2.0 Ton Capacity Window type AC | 5 | Each | |
40 | 40 | Electric blower motor suitable for 1.5 Ton Split AC (Evaporator/Condenser) | 10 | Each | |
41 | 41 | Electric blower motor suitable for 2.0 Ton Split AC (Evaporator/Condenser) | 5 | Each | |
42 | 42 | Electric blower motor suitable for 3.0 Ton Split AC (Evaporator/Condenser) | 2 | Each | |
43 | 43 | Blower motor fan blade suitable for 1.5/2.0 Window type AC | 5 | Each | |
44 | 44 | Blower motor fan blade suitable for 1.5/2.0 Split type AC | 6 | Each | |
45 | 45 | Blower motor fan blade suitable for 3.0 Split type AC | 1 | Each | |
46 | 46 | Rewinding of Condenser motor with fan blade suitable for 1.5 Ton capacity Window type AC | 10 | Each | |
47 | 47 | Rewinding of Condenser motor with fan blade suitable for 2.0Ton capacity Window type AC | 4 | Each | |
48 | 48 | Rewinding of Condenser motor with fan blade suitable for 1.5 Ton capacity Split type AC | 8 | Each | |
49 | 49 | Rewinding of Condenser motor with fan blade suitable for 2.0 Suitable for Split type AC | 8 | Each | |
50 | 50 | Rewinding of Condenser motor with fan blade suitable for 3.0 Suitable for Split type AC | 1 | Each | |
51 | 51 | Thermostat switch with knob suitable for AC of any capacity. | 30 | Each | |
52 | 52 | Air Filter Suitable for 1.5/2.0/3.0 Ton Capacity Window/Split type Air conditioner | 25 | Each | |
53 | 53 | Capillary tube length as per existing size suitable for 1.5/2.0/3.0 Ton Capacity Air conditioner | 20 | Each | |
54 | 54 | PCB Circuit with remote control suitable for any make and capacity of 1.5/2.0 Ton Window type AC | 10 | Each | |
55 | 55 | PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0/3.0 split type capacity Air Conditioner Note: Item Serial No. 12.13 to 12.43. Make: Renutrol/Indfos/Kelvinator or equivalent | 10 | Each | |
56 | 56 | Metal top with bottom suitable for 16 Amps Capacity 1.5/2.0/3.0 Ton Capacity Air conditioner Make: Anchor/Havells/Philips/polycab and as per site requirement. | 50 | Each | |
57 | 57 | LPG Gas | 10 | Kg | |
58 | 58 | Brazing rod | 5 | Kg | |
59 | 59 | Refrigerant gas R22/R-32 for topping up.(Make: Myfron/ Preton) | 35 | Kg | |
60 | 60 | Refrigerant gas R 134(a) for topping up.(Make: Myfron/ Preton) | 35 | Kg | |
61 | 61 | Refrigerant gas R 410(a) for topping up.(Make: Myfron/ Preton) | 50 | Kg | |
62 | 62 | M&L for replacement of damaged Insulation of size 1/4&3/8 for Split AC complete as per existing site complete all as specified and directed by Engineer in Charge | 100 | RM | |
63 | 63 | M&L for replacement of damaged Insulation of size 1/2 & 5/8 for Split AC complete as per existing site complete all as specified and directed by Engineer in Charge | 100 | RM | |
64 | 64 | M&L for replacement of Rubber bush suitable for 1.5/2.0/3.0 ton capacity Suitable for Air conditioner as per sample complete all as specified and directed by Engineer in Charge | 10 | set | |
65 | 65 | M&L in servicing of inverter AC of capacity 1.5 Ton all as directed by Engr-in-Charge. | 4 | Each Job | |
66 | 66 | M&L to repair and replacement of indoor unit, cooling motor at the existing type and capacity as per sample including taking down the unservieable items. | 4 | Each Job | |
67 | 67 | M&L for replacement of Copper Tube of size 1/4 suitable for any type and any capacity Air conditioner complete all as specified and directed by Engineer in Charge. | 25 | RM | |
68 | 68 | M&L for replacement of Copper Tube of size 3/8 and 5/8 suitable for any type and any capacity Air conditioner complete all as specified and directed by Engineer in Charge. | 25 | RM | |
69 | 69 | M&L for replacement of Plug nut of size 1/2 and 3/8 suitable for any type and any capacity Air conditioner complete all as specified and directed by Engineer in Charge | 10 | Each | |
70 | 70 | M&L for replacement of Plug nut of size 5/8 suitable for any type and any capacity Air conditioner complete all as specified and directed by Engineer in Charge. | 10 | Each | |
71 | 71 | Taking out and shifting new location and refixing both indoor and outdoor unit of split type Air conditioning electrically driven 230V/250V ,AC 50 Hz capacity 1.5/2.0/3.0 Ton in wall with rowl plugs including making holes for inlet /outlet in the wall with 50mmX50mmX6mm size of agle iron for foundation of condensing unit as per suitable size and making good existing surface including insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer complete all as specified and directed. | 10 | Each Job | |
72 | 72 | M&L for repairs to walk in cooler 1.5 Ton and repair/replacement the compressor, filter including gas charging and general service complete all as specified and directed.Make- Voltas/Blue Star/Samsung or equivalent | 1 | Each Job | |
73 | 73 | Dismantling and taking out the existing old unsv compressor sealed unit from Water cooler and S&F new compressor copper wound unit for operation on single phase, 230 V, 50 Hz, AC supply & confirm to IS-1067 Part-I, suitable for Water cooler of cooling capacity 40/80 ltrs/hrs and complete. | 6 | Each Job | |
74 | 74 | All as per item No.73 here in before but compressor suitable for Water Cooler of cooling capacity 60/120 ltrs/hrs complete all as specified and directed. | 6 | Each Job | |
75 | 75 | All as per item No. 73 here in before but compressor suitable for Water Cooler of cooling capacity 150 ltrs/hrs complete all as specified and directed.Make for Sl No 24 to 26 -Kirloskar/Blue star/LG/Tecumseh | 6 | Each Job | |
76 | 76 | M&L for carry out through check up of the unserviceable water cooler of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- (i) Quoted rate is deemed to be included in minor requirement such as insulation tape, screws, small pieces of wires,plug top etc (ii). Spare parts shall be measured and paid separately in relevent item here-in-after. | 75 | Each Job | |
77 | 77 | Supply only following parts for repair of water cooler:- | |||
78 | 78 | Blower fan motor SP,230V, 50 Hz suitable for 40/80 capacity water cooler as per existng sample complete all as specified and directed by Engineer -in-Charge | 20 | Each | |
79 | 79 | All as per item here in before but suitable for 150/180,60/120 or equivalent water cooler as per existng sample complete all as specified and directed by Engineer -in-Charge. | 10 | Each | |
80 | 80 | Blower motor fan blade suitable for 150/180,60/120 and 40/80 capacity water cooler. Make:LG/Blue star/Vidiocon | 15 | Each | |
81 | 81 | Capacitor for condenser motor suitable for any capacity, size complete Make:LG/Blue star/Videocon | 20 | Each | |
82 | 82 | Starting Capacitor suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity Make:LG/Blue star/Videocon | 25 | Each | |
83 | 83 | Running Capacitor suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity | 30 | Each | |
84 | 84 | Starting relay current type suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity Make: Univers/Sarada/Usha/Asian | 15 | Each | |
85 | 85 | Over load Protector suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity | 10 | Each | |
86 | 86 | Thermostat switch with knob suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity | 10 | Each | |
87 | 87 | PVC float valve assy alongwith ball with complete accessories for water cooler any capacity of size 15 mm dia . | 15 | Each | |
88 | 88 | Self closing water tap 15 mm dia chromium plated inner/outer thread for water cooler 150/180,60/120 and 40/80 capacity. Make: Waterman/Leader/Prayag/Leader | 30 | Each | |
89 | 89 | Air Filter Suitable for water cooler 150/180,60/120 and 40/80 capacity | 20 | Each | |
90 | 90 | Capillary tube of suitable length as per existing size for water cooler 150/180,60/120 and 40/80 capacity | 25 | RM | |
91 | 91 | M&L for testing the leakage in system by charging of Nitrogen Gas up to 300 PSI. Repairing of leakage spots/Joints with gas welding work, cleaning and flushing the complete water cooler with gas, making the system leak proof, vacuuming the complete system complete | 20 | Each Job | |
92 | 92 | M&L for dismantling of water cooler of any capacity and taking out complete internal assembly ie. Inner tank, inlet and out let connection etc and descaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket complete all as specified and directed | 15 | Each Job | |
93 | 93 | M&L for removing burnt/defective sealed compressor unit of any make from any type and Capacity of 165 to 200 Ltrs refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit complete. Make- Godrej/Vidiocon/Whirlpool/LG/Carrier/Daikin | 10 | Each Job | |
94 | 94 | All as per item No.93 here in before but compressor suitable for refrigerator capacity of 280 to 320 Ltrs complete all as specified and directed. Make- Godrej/Vidiocon/Whirlpool/LG/Carrier/Daikin | 5 | Each Job | |
95 | 95 | M&L carry out through check up the unserviceable Refirgerator of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- (i) Quoted rate is deemed to be included in minor requirement such as insulation tape, screws, small pieces of wires,plug top etc (ii). Spare parts shall be measured and paid separately in relevent item here-in-after. | 35 | Each job | |
96 | 96 | Supply only following parts for repair of refrigerator:- | |||
97 | 97 | Magnetic door gasket suitable for 165 to 200 ltrs capacity Refrigerator. | 5 | Each | |
98 | 98 | Magnetic door gasket suitable for 286/320 Ltrs capacity Refigerator. | 5 | Each | |
99 | 99 | Freezer Assembly with coil suitable for 165 to 200 ltrs capacity Refrigerator.Make: Kelvinator, Voltas, Blue Star, Alwyn, Sriram. | 10 | Each | |
100 | 100 | Freezer door suitable for 286/310 Ltrs capacity Refigerator | 5 | Each | |
101 | 101 | Relay current type and over load protector suitable for compressor complete.Make:-Renutrol, Sriram, KCL, Annapurna. | 20 | Each | |
102 | 102 | Thermostat auto defrost type suitable for any make and any capacity Refrigerator.Make: Danfos/Ind Foss/renutrol | 10 | Each | |
103 | 103 | Air Filter suitable for for any make and any capacity Refrigerator | 5 | Each | |
104 | 104 | Capillary tube of suitable length as per existing size for refrigerator any make and any capacity | 25 | RM | |
105 | 105 | M&L carry out through check up the defective Refirgerator of inverter type of capacity 300 Ltr by carrying out through checek up and tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- (i) Quoted rate is deemed to be included in minor requirement such as insulation tape, screws, small pieces of wires,plug top etc (ii). Spare parts shall be measured and paid separately in relevent item here-in-after. Make- Godrej/Videocon/Whirlpool/LG/Carrier/Daikin | 10 | Each job | |
106 | 106 | Supply only following parts for repair of refrigerator:- | |||
107 | 107 | Electric blower motor suitable for 300 ltr refrigerater inverter type. | 5 | Each | |
108 | 108 | PCB Circuit suitable for 300 ltr refrigerater inverter type. | 5 | Each | |
109 | 109 | Heating sensor suitable for 300 ltr regrigerater inverter type. Make- Whirlpool, Samsung, LG or equivalent | 5 | Each | |
110 | 110 | Thermostate suitable for 300 ltr regrigerater inverter type | 2 | Each | |
111 | 111 | M&L for removing burnt/defective sealed compressor unit of any make from Capacity 155 to 200 Ltr of Deep freezer by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit complete all as specified and directed at site by the Engr-in-Charge. Make: Emerson | 5 | Each Job | |
112 | 112 | All as per item No.37.00 here in before but compressor suitable for Deep freezer capacity of 250 to 320 Ltrs complete all as specified and directed. Make: Emerson | 5 | Each Job | |
113 | 113 | M&L for testing the leakage in system by charging Nitrogen Gas up to 300 PSI. Repairing the leakage spots/Joints with welding work including supply and replacement of filter pencil type copper and capillary tube of existing dia & length. Making the system leakproof vacuuming the system complete | 8 | Each Job | |
114 | 114 | M&L carry out through check up the unserviceable Deep Freezer of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- (i) Quoted rate is deemed to be included in minor requirement such as insulation tape, screws, small pieces of wires,plug top etc (ii). Spare parts shall be measured and paid separately in relevent item here-in-after. | 15 | Each Job | |
115 | 115 | Supply only following parts for repair of deep freezer:- | |||
116 | 116 | Relay current type and over load protector suitable for compressor .Make: Renutroll, Sriram, KCL, Annapurna. | 10 | Each | |
117 | 117 | Thermostat auto defrost type suitable for any make and any capacity Deep Freezer .ake : Indofoss/dandfoss/Annapurna | 10 | Each | |
118 | 118 | Drier filter complete set suitable for any make and any capacity Deep Freezer | 10 | Each | |
119 | 119 | Indicating lamp (Red and Green) 230V complete suitable for any make and any capacity Deep Freezer as per sample complete | 10 | Each | |
120 | 120 | Capillary tube of suitable length as per existing size for Deep freezer any make and any capacity | 25 | RM | |
121 | 121 | Starting relay suitable for 310/320 ltrs capacity Deep freezer.Make: Renutroll, Sriram, KCL, Annapurna. | 5 | Each | |
122 | 122 | Condenser motor (Rotary fan) suitable for any type and any capacity deep freezer.Make; AUE/Cool Blow/Universal | 10 | Each | |
123 | 123 | Starting capacitor suitable for Deep freezer suitable for any type and any capacity deep freezer. Make: Simens/Epcos | 10 | Each | |
124 | 124 | Labour only for charging of refrigerent gas R-22/R-410A/R-134(a) for Refrigerator/Deep freezer/Water cooler/Window and split type Air conditioner after duly rectifying leakages by welding/brazing and testng by charging N2 gas for 24 hours complete all as specified and directed . Note:- Refrigerant gas shall be measured and paid separately under relevent items of this schedule. | 75 | Each Job | |
125 | 125 | Dismantling and taking out the existing old unsv fan motor with blade including mounting brackets from Desert coolers and S&F new fan motor with blade of capacity 1/6 HP (125 W), 230 V, 50 Hz, SP, AC sup confirming to IS-996/79 (motor only) with mounting accessories and connection complete suitable for D/cooler of capacity 4000/5000/6000 Cum per hrs complete all as specified and directed. Make- Khaitan/Crompton,Polar, Texmo OR equivalent. | 300 | Each Job | |
126 | 126 | M&L for repair to Desert cooler dismantling the unserviceable parts of Desrt coolers,checking the general servicing complete all as specified and directed. Note:- (i) Quoted rate is deemed to be included in minor requirement such as insulation tape, screws, small pieces of wires,plug top etc (ii). Spare parts shall be measured and paid separately in relevent item here-in-after. | 350 | Each Job | |
127 | 127 | Supply only following parts for repair of desert cooler:- | |||
128 | 128 | Water circulating submesible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hr .Make- Khaitan/Crompton OR equivalent. | 400 | Each | |
129 | 129 | Filter pad made out of wooden wool suitalbe for Air grills of desert cooler as per existing size | 400 | Set of 3 | |
130 | 130 | Capacitor for 2.5/4MFD Make: Usha/Asian/KEIL | 100 | Each | |
131 | 131 | Capacitor for 5/6 MFD. Make: Usha/Asian/KEIL | 45 | Each | |
132 | 132 | Front panel of dimension as per existing size suitable for desert cooler of capacity 4000/5000/6000 Cum per hrs | 60 | Each | |
133 | 133 | Side (03 Side) Panels suitable for as per existing size for desert cooler of capacity 4000/5000/6000 Cum per hrs | 20 | Set of 3 | |
134 | 134 | PVC Flexible hose suitable for desert cooler cooling system. Make: Finolex/Supreme/Kisan | 90 | RM | |
135 | 135 | PVC Fan Blade suitable for 3000/4000/5000/6000 as per sample | 20 | Each | |
136 | 136 | Selector switch as per existing model and size | 25 | Each | |
137 | 137 | Bolt, nut with washers as per sample | 2 | Kg | |
138 | 138 | PVC Connector i.e (Elbow, Tee,3 way etc) | 50 | Each | |
139 | 139 | 5 Amp Switch.Make- Havells/Anchor/Finoles | 450 | Nos | |
140 | 140 | 5 Amp Plug Top.Make- Havells/Anchor/Finoles | 200 | Nos | |
141 | 141 | Monoplate with 5 Amp switch. | 25 | Nos | |
142 | 142 | S&F top portion/cover of the desert cooler of the existing size. | 15 | Nos | |
143 | 143 | S&F bottom portion/water storage tank of the existing size. | 15 | Nos | |
144 | 144 | Taking down the evaporative type desert coolers of Capacity upto 5000 Cum/hr by disconnecting all the electrical connections cleaning all the components by removing the side panels and painting the coolers with two coats of synthetic enamel paint out side and moisture resistance primer inside with spray painting and fixing back the removed panel and reconnecting with electrical connections and writing the MES No complete all as directed by Engineer-in-Charge. | 500 | Each\nJob | |
145 | 145 | M&L for repair to Voltage stablizer of capacity 0.5/1.0/2.0KVA, dismantling the unserviceable parts of voltage stablizer ,checking the general servicing complete all as specified and directed. | 25 | Each Job | |
146 | 146 | All as per item No.145 here in before but voltage Stablizer of capacity 3/4/5 KVA complete all as specified and directed. Note:- (i) Quoted rate is deemed to be included in minor requirement such as insulation tape, screws, small pieces of wires,plug top etc (ii). Spare parts shall be measured and paid separately in relevent item here-in-after. | 25 | Each Job | |
147 | 147 | Supply only following parts for repair of voltage stabilzer:- | |||
148 | 148 | Relay for the existing capacity of stabilizer any make and any capacity | 10 | Each | |
149 | 149 | Electronic circuit board for the existing capacity of stabilizer any make and any capacity | 10 | Each | |
150 | 150 | Cut out of 15 Amps for the existing capacity of stabilizer any make and any capacity | 10 | Each | |
151 | 151 | Volt meter indicating 100-300 Volt for the existing capacity of stabilizer any make and any capacity | 10 | Each | |
152 | 152 | Voltage control Transformer suitable for 0.5/1.0 Voltage Stabilizer | 5 | Each | |
153 | 153 | Voltage control Transformer suitable for 2/3 KVA Voltage Stabilizer | 5 | Each | |
154 | 154 | Voltage control Transformer suitable for 4/5 KVA Voltage Stabilizer | 5 | Each | |
155 | 155 | PVC insulated and PVC over all covered cord cable copper conductor 3 core of size 2.5 Sqmm Make- Plaza/Havells/ Finolex. | 50 | RM | |
156 | 156 | Taking down the unserviceable Sheet metal enclosure and supply and fix Sheet metal enclosures with flush mounted type ply and socket with 240 V SP MCB 20 amps Capacity Make: ABB/Legrand/Havells or Equivalent | 15 | Each | |
157 | 157 | Taking down carefully unserviceable Sub main wiring including unserviceable fittings such as switches, ceiling roses, regulators etc complete and making good disturbed surfaces of walls, floors etc.complete all as specified and as directed by Engineer-in charge. | 50 | RM | |
158 | 158 | M&L for sub main wiring with 6 Sqmm (Nominal area) with two runs (Red for phase and Black for neutral) of single core, PVC insulated, multistranded, unsheathed, copper conductor cables 1100 V grade drawn through PVC conduits/casing-caping fixed to wall/ceiling etc including 6 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor green in colour as earth wire and duly connected to earth point complete as specified and directed.complete all as specified and as directed by Engineer-in charge.(Note :- (a) PVC conduits/casing caping and Two runs cables and one run of earth wire will be measured as one length.) | 25 | RM | |
159 | 159 | M&L for sub main wiring with 4 Sqmm (Nominal area) with two runs (Red for phase and Black for neutral) of single core, PVC insulated, multistranded, unsheathed, copper conductor cables 1100 V grade drawn through PVC conduits/casing-caping fixed to wall/ceiling etc including 4 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor green in colour as earth wire and duly connected to earth point complete as specified and directed.complete all as specified and as directed by Engineer-in charge.(Note :- (a) PVC conduits/casing caping and Two runs cables and one run of earth wire will be measured as one length.) | 25 | RM | |
160 | 160 | M&L point wiring with 2.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 2.5Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light point controlled by one ,one way switches as specified and directed. complete all as specified and as directed | 50 | RM | |
161 | 161 | Repair and maint in replacement AHU filter of size down to micron and EU-4 size and CFM shall be as per site requirement complete all as specified and directed. | 16 | Each Job | |
162 | 162 | Taking down the existing UNSV filter from AHU upto to 10500 CFM, cleaning the cooling coil with suitable chemical and jet of water pressure with pump and remove all the scales and foreign material deposited in side coil followed with air pressure to sweep up all the particles and ensure through flow of air over the cooling coil and refixing the air filter after cleaning complete all as specified and directed. | 4 | Each Job | |
163 | 163 | Repair and maint in replacement AHU blower shaft upto 10500 CFM, hollow or solid made out of high speed steel, including machine work up to required dia and length, making slot, key and hole and renewal of backet bearings as per site requirement and testing complete all as specified and directed. | 3 | Each Job | |
164 | 164 | M&L in repair for pumping down the existing refrigerant gas in separate cylinder immediately after end of season and fill/re charge the gas at the starting of season carry out pressure leak test by nitrogen gas of the system of AC plant 3 x upto 85 TR for leak proof valve joint, seal other connected controls flaries etc including identify & rectify of leak defects and maintaining constant pressure of 160 lbs on low side and 200 lbs at high side at least 24 hrs complete all as specified and directed. Note : Necessary leak proof empty cylinders and necessay pumps , tools required shall be included in the quoted rate. (ii) If any leakage in the cylinder after pumping down, the diffiencies need to be filled by the Contractor without any extra cost. | 1 | Each Job | |
165 | 165 | M&L in repair for descaling of condenser tube of central AC plant of cap 3 x upto 85 TR by disconnecting the condenser from the system cleaning by descaling cloution of make hibrid or descaling solution, cleaning solution, cleaning condenser tube by nylon brush & MS rod of suitable size repalcement of rubber joints and unserviceablenut bolts complete all as specified and directed. Note : Necessary tools need to be included in the above quoted rate. | 3 | Each Job | |
166 | 166 | M&L in repair & replacement of V-belt from AHU motor with the make and size as required and as per sample complete all as specified and directed. | 4 | Each Job | |
167 | 167 | M&L in repair, servicing of compressor of central AC plant of cap 3 x upto 85 TR including replacement of Compressor oil, suction strainer, Compressor oil repair kit and liquid filter cartige etc all as per manufacturer maint guide line complete all as specified and directed. | 3 | Each Job | |
168 | 168 | M&L in maint and cleaning of cooling tower of central AC Plant of capacity 1 x 225 TR by applying suitable chemicals and removing all deposited dust, foreign material, cleaning of filter and servicing of Ct fan motor, sprinklar and PVC arms complete all as specified and directed. | 1 | Each Job | |
169 | 169 | M&L in repair & replacement of cooling tower blade for cooling tower motor of cooling tower of central AC Plant of capacity 1 x upto 85 of make as per site requirement or as per sample complete all as specified and directed. | 1 | Each Job | |
170 | 170 | M&L in repair & replacement sprinkler of cooling tower of central AC plant of cap 1 x 225 TR of make as per site requirement or as per sample complete all as specified and directed. | 1 | Each Job | |
171 | 171 | M&L in repair & replacement of water of water pressure indicating gauge fitted water circulation circuit (Range-0 to 100/150 lbs/sq in and 0 to 7/10.6 kg/sq cm complete all as specified and directed. | 5 | Each Job | |
172 | 172 | Taking out old defective burnout motor of capacity 5 to 10 HP, 3 phase, 440 V, 50 Hz from foundation and transfer it to workshop for rewinding with super enamelled copper wire of existing size & gauge and replacement of DE & NDE bearing so as to match the manufacturers original specification and refitting the same, testing and commissioning complete all as specified and directed. | 4 | Each Job | |
173 | 173 | M&L for filling compressor oil grade CPI 120 for compressor complete all as specified and directed. | 50 | Ltr | |
174 | 174 | M&L for repair in replacement micro process computerised mother board suitable for Central AC Plant upto 85 TR Panel of Make Voltas (Model No VLX 1130) complete all as specified and as directed. | 1 | Each Job | |
175 | 175 | M&L repair of GSS ducting for supply and retrain complete with flanges, nut, bolts, washers of GI angle iron supports and MS rods complee comprising the following. | |||
176 | 176 | 24 Gauge | 1 | Each Job | |
177 | 177 | 22 Gauge | 1 | Each Job | |
178 | 178 | 20 Gauge | 1 | Each Job | |
179 | 179 | M&L in repair & replacement AHU pre filter of size, down to micron and EU-4, size and CFM shall be as per site requirement complete all as speficied and directed. | 11 | Each Job | |
180 | 180 | M&L in repair & replacement AHU fine filter of size, down to micron and EU-4, size and CFM shall be as per site requirement complete all as speficied and directed. | 8 | Each Job | |
181 | 181 | M&L in repair & replacement AHU HEPA NANO filter of size, down to micron and EU-4, size and CFM shall be as per site requirement complete all as speficied and directed. | 24 | Each Job | |
182 | 182 | M&L in repair of cladding in external duct and exposed pipe. | 47 | Sqm | |
183 | 183 | M&L in repair of insulation 25 mm thick in duct and and pipe line. | 46 | Sqm | |
184 | 184 | M&L in repair of AHU coil suitable size. | 2 | Each | |
185 | 185 | M&L in repair of 3 way mixing valve of suitable size as per site requirement. | 2 | Each | |
186 | 186 | Supply only 407C gas for Compressor as required in servicing complete all as specified and directed. | 110 | Kg | |
187 | 187 | M&L in repair temperature sensor at inlet and outlet on both ends of Chiller. | 4 | Each | |
188 | 188 | M&L in repair and maint of chilled water pipe with MS ERW class `C' pipe (Heavy conforming to IS-1239-1958), complete with all accessories such as bends, elbows, flanges, nut bolts, air purging valves, descaling valves. | |||
189 | 189 | 150 mm dia | 40 | RM | |
190 | 190 | 100 mm dia | 20 | RM | |
191 | 191 | 80 mm dia | 50 | RM | |
192 | 192 | 65 mm dia | 20 | RM | |
193 | 193 | 40 mm dia | 25 | RM | |
194 | 194 | M&L in repair & replacement of power contractor 25 Amps of the LT panel of AC Plant, 3 Pole, AC, 415 V, 50 HZ, 3 Phase, complete all as specified and directed.Make: Bhartia Cutler Hammer/Seamens | 2 | Each | |
195 | 195 | M&L in repair & replacement of relay 25 Amps of the LT panel of AC Plant, 3 pole, AC, 415 V, 50 Hz, 3 Phase, complete all as specified and directed. Make: Bhartia Cutler Hammer/Seamens | 5 | Each | |
196 | 196 | Supply and fixing of butterfly valve in repair of following size mentioned below:- | |||
197 | 197 | 150 mm bore | 2 | Each | |
198 | 198 | 100 mm bore | 2 | Each | |
199 | 199 | 80 mm bore | 1 | Each | |
200 | 200 | M&L in repair and complete overhauling and through checking of of 5TR capacity package type AC unit including leak tesing and pressure testing for 24 hours and gas changing with R-22 refrigarent including testing with Nitrogen gas etc, complete all as specified and directed by Engr-in-Charge. | 1 | Per Job |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy