Repair/Maintenance /Servicing Of Central Gas Plant , Modular Operation Theatre Including Repair/Maint Of Various Types Of Fans And Stabilizers In The Area Of Age Em ( Hosp ) Under Ge E/M Lucknow, Lucknow-Uttar Pradesh

Military Engineer Services-MES has published Repair/Maintenance /Servicing Of Central Gas Plant , Modular Operation Theatre Including Repair/Maint Of Various Types Of Fans And Stabilizers In The Area Of Age Em ( Hosp ) Under Ge E/M Lucknow. Submission Date for this Tender is 31-10-2020. Gas Power Plants Tenders in Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

25689656
Repair/Maintenance /Servicing Of Central Gas Plant , Modular Operation Theatre Including Repair/Maint Of Various Types Of Fans And Stabilizers In The Area Of Age Em ( Hosp ) Under Ge E/M Lucknow
Open Tender
Indian
Uttar Pradesh
Lucknow
31-10-2020

Tender Details

Repair/Maintenance /Servicing Of Central Gas Plant , Modular Operation Theatre Including Repair/Maint Of Various Types Of Fans And Stabilizers In The Area Of Age Em ( Hosp ) Under Ge E/M Lucknow

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR / MAINT/SERVICING OF CENTRAL GAS PLANT, MODULAR OPERATION THEATRE INCLUDING REPAIR / MAINT OF VARIOUS TYPES OF FANS AND STABILIZERS IN THE AREA OF AGE EM (HOSP) UNDER GE E/M LUCKNOW.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Comprehensive servicing and maintenance of central gas pipe line system comprising of Oxygen, Nitrous and compressed air system of desired pressure required to operation theatre-05 Nos at Command Hospital (CC) including regular & periodical maintenace/overhauling,replacement of air filters,tail pipe, NRV, pressure control switch, machine belts and shut off valves,including all connected equipments installed for the said purpose having following components of various make/capacity:- Note :- Register signed by Contractor, AGE E/M and USer same time whenever work carried out \n(a) Oil free comprssor of capacity 7.5 HP of make Multitech with pressure control switch-02 Nos\n(b) Heatless air drier of capacity 30cfm of make Multitech-02 Nos\n(c) Automatic control panel for oxygen with alarm system-01 No. \n(d) Automatic control panel for Nitrous oxide with alarm system-01 No. \n(e) 6+6 cylinder Oxygen manifold with NRV & 12 Nos flexible tail pipe-01 No\n(f) 2+2 cylinder Nitrous oxide manifold with NRV & 04 Nos flexible tail pipe-01 No\n(g) Electrical control panel for above compressor \n(h) Digital area alarm system of four gases-01 No\n(j) Parkodex outlet points confirming to HTM-2022/NFPA-99 for oxygen vaccum compressed air & nitrous oxide-44 Nos. \n(k) Isolation valve of 28mm,22mm,15mm & 12mm-20 Nos.\n(l) Backpressure compensated flow meter with humidifier bottles -10 Nos.\n(m) Copper pipe line complete of dia 28mm,22mm,15mm & 12mm installed in the OT complex-600 RM\n(n) Ward vaccum unit with 2000ml polycarbonate jar-08 Nos.\n(o) Joint weekly visit shall be arranged by the contractor and all the OT lights shall be made functional in all respect and necessary report duly signed by the OT incharge of CH(CC) and Base Hospital and JE Concern shall be submitted to AGE Hosp on Same Day . Inspection note shall be endorsed by technician related of repair works to be carriedout.\n(p) Urgent spares shall be readly made available at site during all days by the contractor. BI01010001010000000000000515BI0100001114 12 Each Job (Every fortnightly)
2 2 Supplying, and fixing Isolation valve with brass connectors of size 12 mm including testing and commissioning complete all as specified and as directed by Engineer -in-Charge. 20 Each
3 3 Supplying, and fixing Isolation valve with brass connectors of size 15 mm including testing and commissioning complete all as specified and as directed by Engineer -in-Charge. 20 Each
4 4 Supplying, and fixing Isolation valve with brass connectors of size 22 mm including testing and commissioning complete all as specified and as directed by Engineer -in-Charge 20 Each
5 5 Supplying, and fixing Isolation valve with brass connectors of size 28 mm including testing and commissioning complete all as specified and as directed by Engineer -in-Charge 20 Each
6 6 Supplying, fixing, testing and commissioning hook loose type outlet point dia cast zinc alloy, for oxygen, compressed air, vacuum and nitrous oxide with stainless steel box complete all as specified and as directed by Engineer -in-Charge 15 Each
7 7 S&F probe for oxygen outlet unit, compressed air, vacuum and nitrous oxide complete all as specified and as directed by Engineer -in-Charge 20 Each
8 8 Supplying, errecting, testing and commissioning mobile floor suction unit for operation theatre made out of stainliess steel having one vacuum regulator and two suction jar of 2000 ml capacity complete all as specified and as directed by Engineer -in-Charge 4 Each
9 9 Supply, fixing, laying, testing and commissioning wall mounted ward vacuum unit with collection bottle (200 ml) and regulator including adopter/ commecting clear plastic/ rubber tubes and connecting up complete all as specified and as directed by Engineer -in-Charge 4 Each
10 10 Supply, fixing, laying, testing and commissioning of back pressure compensated oxygen flow meter (BPC) and humidifier including adopter and connecting up complete all as specified and as directed by Engineer -in-Charge 18 Each
11 11 Supplying, fixing, laying, testing and commissioning Oxygen H.P. antistatic rubber tube color coded 'white' of suitable length & size including required fittings and connecting up complete all as specified and as directed by Engineer -in-Charge 30 RM
12 12 Supplying, fixing, laying, testing and commissioning Oxygen L.P. antistatic rubber tube color coded 'white' of suitable length & size including required fittings and connecting up complete all as specified and as directed by Engineer -in-Charge 30 RM
13 13 Supplying, fixing, laying, testing and commissioning of oxygen gas outlet (as per HTM-2022 / NFPA-99) with and including matching adopter and connecting up complete all as specified and as directed by Engineer -in-Charge 10 Each
14 14 Supplying, fixing, laying, testing and commissioning of compressed air (4 Bar) outlets (as per HTM-2022 / NFPA-99) with and including matching adopter and connecting up complete all as specified and as directed by Engineer -in-Charge 10 Each
15 15 Supplying, fixing, laying, testing and commissioning of Nitrous gas outlets (as per HTM-2022 / NFPA-99) with and including matching adopter and connecting up complete all as specified and as directed by Engineer -in-Charge 10 Each
16 16 Supplying, fixing, laying, testing and commissioning of Vacuum gas outlets (as per HTM-2022 / NFPA-99) with and including matching adopter and connecting up complete all as specified and as directed by Engineer -in-Charge 10 Each
17 17 Supplying, laying, testing and commissioning medical gases distribution piping system comprising of copper pipes of 12 mm outer dia, having wall thickness 0.90 mm including Tees, Bends, Sockets, Specials, Fittings and fixtures etc. and applying two coats of suitable paint of required colour complete all as specified and as directed by Engineer -in-Charge 60 RM
18 18 Supplying, laying, testing and commissioning medical gases distribution piping system comprising of copper pipes of 22 mm outer dia, having wall thickness 0.90 mm including Tees, Bends, Sockets, Specials, Fittings and fixtures etc. and applying two coats of suitable paint of required colour complete all as specified and as directed by Engineer -in-Charge 50 RM
19 19 Supplying, laying, testing and commissioning medical gases distribution piping system comprising of copper pipes of 15 mm outer dia, having wall thickness 0.90 mm including Tees, Bends, Sockets, Specials, Fittings and fixtures etc. and applying two coats of suitable paint of required colour complete all as specified and as directed by Engineer -in-Charge 50 RM
20 20 Supplying, laying, testing and commissioning medical gases distribution piping system comprising of copper pipes of 28 mm outer dia, having wall thickness 0.90 mm including Tees, Bends, Sockets, Specials, Fittings and fixtures etc. and applying two coats of suitable paint of required colour complete all as specified and as directed by Engineer -in-Charge 50 RM
21 21 Servicing/overhauling of Oxygen / Nitrous gas control panel including overhauling of regulators,cleaning of filters, replacement of unsv control switches,valves,gauges etc and making panel fully functional in all respect and testing of output pressure of gases upto desired parameters as required inside the operation theatre in CH (CC) all as required at site. 12 Each job (every fortnightly)
22 22 Servicing/overhauling of medical dry compressed air system, non lubricated, air cooled, 30 CFM capacity with electric motor of suitable capacity not less than 7.5 HP 3 phase comprising air drier, after cooler & pressure control valve with necessary interconnection piping with necessary pressure regulating and control unit with valves, DOL starter,fittings, gauges including connecting the system to distribution piping of the system complete all as specified. 2 Each job
23 23 S & F HP cylinder complete all as specified and as directed by Engineer -in-Charge 2 Each
24 24 S & F HP ring complete all as specified and as directed by Engineer -in-Charge 2 Each
25 25 S & F HP piston complete all as specified and as directed by Engineer -in-Charge 2 Each
26 26 S & F LP cylinder complete all as specified and as directed by Engineer -in-Charge 2 Each
27 27 S & F LP ring complete all as specified and as directed by Engineer -in-Charge 2 Each
28 28 S & F LP piston complete all as specified and as directed by Engineer -in-Charge 2 Each
29 29 S& F HP / LP valve set and valve guide complete all as specified and as directed by Engineer -in-Charge 4 Each \nSet
30 30 S& F Main ball bearing set complete all as specified and as directed by Engineer -in-Charge 2 Each
31 31 S & F basin ball bearing complete all as specified and as directed by Engineer -in-Charge 6 Each
32 32 S & F cage bearing complete all as specified and as directed by Engineer -in-Charge 6 Each
33 33 S & F HP / LP valve plate complete all as specified and as directed by Engineer -in-Charge 6 Each
34 34 S & F Air filter complete all as specified and as directed by Engineer -in-Charge 4 Each
35 35 S & F racking Kit complete all as specified and as directed by Engineer -in-Charge 2 Each
36 36 S & F Oil seal complete all as specified and as directed by Engineer -in-Charge 2 Each
37 37 S & F connecting rod seal complete all as specified and as directed by Engineer -in-Charge 6 Each \n
38 38 M & L for copper winding 0f capicity 7.5 HP with existing gauge same wire complete all as specified and as directed by Engineer -in-Charge 2 Each
39 39 Supply and fixing in repairs nylon 'V' belts of the B - 82 sizes complete all as specified and as directed by Engineer -in-Charge 2 Each \n
40 40 Supply and fixing in repairs nylon 'V' belts of the B - 32 sizes complete all as specified and as directed by Engineer -in-Charge 4 Each
41 41 Supply and fixing in repairs nylon 'V' belts of the B - 51 sizes complete all as specified and as directed by Engineer -in-Charge 4 Each
42 42 Supply and fixing in repairs nylon 'V' belts of the B - 51 sizes complete all as specified and as directed by Engineer -in-Charge 2 Each
43 43 Supply and fixing in replacement power contactor MNX 18, 3 phase in existing LT panel all as specified and directed. complete all as specified and as directed by Engineer -in-Charge 8 Each
44 44 Taking out carefully defective / burnt power contactor type ML-1.5 from the LT panel board and supply & fixing new in position in replacement power contractor ML-1.5 complete all as specified and as directed by Engineer -in-Charge 8 Each
45 45 Attending complaints on priroty basis for maintenance of 04 Nos modular and 05 Nos of conventional operation theatre at Command hospital & Base Hospital Lucknow comprising of anesthesia pendent fixed type-02 Nos and sweivel type-02 (Make: MDD), shadowless light fittings ) having major and satelite dooms of technical specification mentioned hereinafter,shadowless lights for non-conventional OTs-05 Nos (Make:Philips) speripheral lights 2x55 watts (Make:Philips) , scrub sink-04 Nos (Make:MDD), hermatically sealed sliding doors-04 Nos (Make:Metaflux), complete all as specified and as directed by Engineer -in-Charge ( a ) Contractor shall bound to attend the complaint with in one hour after receiving it from JE and AGE. ( b ) Jointly visit shall be arranged by the contractor during changing any spare parts and all the OT lights shall be made functional in all respect and necessary report duly signed by the OT incharge of CH(CC) and Base Hospital and JE Concern shall be submitted to AGE Hosp on Same Day . Inspection note shall be endorsed by technician related of repair works to be carriedout. \n( c ) Urgent spares parts shall be readly made available at site during all days by the contractor. (d) Whenever Coplaint attend by technitian also included servicing of same items. 90 Each Job
46 46 S&F Halogen bulbs , 12 volts50 watts having input voltage 230±230 Votls and out put voltage 10.5 to 12.5 volts on load in 4 steps of 50 Hz, supply suitable for Trilux OT lights haivng light out put of 120000 Lux for major and 70000 Lux for satellite doom complete all as specified and as directed by Engineer -in-Charge 160 Each
47 47 S&F Halogen medical reflector 24V 150 watts suitable for shadoless light fitting of make Philips having major and standard doom all as required at site complete all as specified and as directed by Engineer -in-Charge. 25 Each
48 48 S&F in repair thermostatic mixing valve provided for constant water termpreature withdefined setting of adjustable timing of 1, 3, 5, 10 minute complete all as specified and as directed by Engineer -in-Charge 15 Each
49 49 S&F in repair electrc photo sensor suitable for two bay surgical surb sink for hads free operation with built in range of adjustment complete all as specified and as directed by Engineer -in-Charge 10 Each
50 50 S&F in repair solenoid valve 24 volt suitable for two bay surgical scurb sink for hands free operation with built in range of adjustment complete all as specified and as directed by Engineer -in-Charge 10 Each
51 51 Supplying and fixing espagnolet electromagnetic lock mounted on track and on both side key switch suitable for hermatically sealed door having width 3500 mm complete all as specified and as directed by Engineer -in-Charge 10 Each
52 52 Supplying and fixing microprocessor controlled sensor suitable for electromechanical sliding door having width 3500 mm and total weight 250 Kgs and slow speed 20-120 mm/sec,starting speed 20-220 mm/sec,opening speed 800mm/sec and closing speed 500 mm/sec operated on 3 phase 415 volts 50 Hz AC supply complete all as specified and as directed by Engineer -in-Charge 10 Each
53 53 S&F in repair foot switch suitable for hermatically sealed door of modular OT of make Metaflux complete all as specified and as directed by Engineer -in-Charge 5 Each
54 54 S&F in repair runner wheel MF5 suitable for hermatically sealed door of modular OT of make Metaflux complete all as specified and as directed by Engineer -in-Charge 5 Each
55 55 S&F in repair guide roller set MF5 suitable for hermatically sealed door of modular OT of make Metaflux complete all as specified and as directed by Engineer -in-Charge 5 Each
56 56 S&F in repair side sealing gasket suitable for hermatically sealed door of modular OT of make Metaflux complete all as specified and as directed by Engineer -in-Charge 10 Each job
57 57 S&F in repair teath belt suitable for hermatically sealed door of modular OT complete all as specified and as directed by Engineer -in-Charge 10 Each job
58 58 S&F in repair photo cell suitable for hermatically sealed door of modular OT complete all as specified and as directed by Engineer -in-Charge 10 Each job
59 59 S&F in repair motor 370 watts suitable for hermatically sealed door of modular OT complete all as specified and as directed by Engineer -in-Charge 9 Each job
60 60 S&F in repair SDA 04 controller suitable for hermatically sealed door of modular OT complete all as specified and as directed by Engineer -in-Charge 9 Each job
61 61 Supply and fix in repair 1.5 sqmm single core, copper wire, multistranded, PVC insulated, unsheathed, 1100 volts grade complete all as specified and as directed by Engineer -in-Charge 200 RM
62 62 Supply and fix in repair 2.5 sqmm single core, copper wire, multistranded, PVC insulated, unsheathed, 1100 volts grade complete all as specified and as directed by Engineer -in-Charge 200 RM
63 63 Supply and fix in repair 4.0 sqmm single core, copper wire, multistranded, PVC insulated, unsheathed, 1100 volts grade complete all as specified and as directed by Engineer -in-Charge 100 RM
64 64 Supply and fix in repair 6.0 sqmm single core, copper wire , multistranded, PVC insulated, unsheathed, 1100 volts grade complete all as specified and as directed by Engineer -in-Charge 100 RM
65 65 Supply and fix in repair 10.0 sqmm single core, copper wire, multistranded, PVC insulated, unsheathed, 1100 volts grade complete all as specified and as directed by Engineer -in-Charge 200 RM
66 66 M & L for check and rectify the all kind of leakages in central gas system meant for operation theatre,MI room CH CC including oxygen,nitrous and compressed air system and receiver tank including control and central alarm panel of respective gases with minor repair carried out . All as specified and directed Note:- (i) any spare parts will be measured and paid in appropreate items. (ii) Contractor shall bound to attend the complaint with in one hour after receiving it from JE and AGE . 110 Each Job
67 67 Supply and install testing and commissining of air purfier of capicity 85 W Air Purifier with Remote Coverage Area 58 m² (958 square feet) ( especially suitable for\nClean Air Delivery Rate (CADR) 500 m³/h (958 square feet) CADR indicates the volume of purified air (in cubic metre) emoves 99.18% allergens & Filtration upto 0.3 microns, 80 times smaller than PM 2.5 which an air purifier produces every hour with 9 Stages of Filtration: Pre-Filter, Cold-Catalyst, Activated Carbon, Antibacterial, HEPA, UV and Anion + Humidifier, Anti Bacterial Balls & 4-Color indications for PPM level at which light changes from 1-50 Green, 51-100 Blue, 101-200 Yellow, 201-500 & above Red, Maximum PM count 500 , with 02 years warrnty complete all as specified and as directed by Engineer -in-Charge 3 Each
68 68 Supply and install testing and commissining of Supply and install testing and commissining of 40 W Air Purifier with Remote Air Purifier Type Room Coverage Area 20 m² (485 square feet) ( especially suitable for bedrooms ) Clean Air Delivery Rate (CADR)180 m³/h (485 square feet) CADR indicates the volume of purified air (in cubic metre) which an air purifier produces every hour removes 99.18% allergens & Filtration upto 0.3 microns, 80 times smaller than PM 2.5 which an air purifier produces every hour with 9 Stages of Filtration: Pre-Filter, Cold-Catalyst, Activated Carbon, Antibacterial, HEPA, UV and Anion + Humidifier, Anti Bacterial Balls & 4-Color indications for PPM level at which light changes from 1-50 Green, 51-100 Blue, 101-200 Yellow, 201-500 & above Red, Maximum PM count 500 , with 02 years warrnty complete all as specified and as directed by Engineer -in-Charge 4 Each
69 69 Disconnecting of ceiling fans of 1200 mm sweep from ceiling rose/connector for cleaning, servicing /oiling and greasing of fan by using appropriate grade of oil / grease and replacing defective parts such as bush bearing , split pin rubber bush, capacitor etc and rehanging the same after proper cleaning and making connection with ceiling fan/connector with flexible wire of size 23/0076 copper conductor multi stranded complete all as specified and as directed by Engineer -in-Charge \n(NOTE :- Parts/component will measuared and paid separtely under respective item of the schedules). 1380 Each
70 70 Rewinding of ceiling fan 1200 mm sweep AC 230 volts single phase with super enamelled copper winding wire of appropriate/existing gauge/size including packing, insulating material soldering varnishing, assembling and testing including transportation charges to and fro from contractor's workshop complete all as specified and as directed by Engineer -in-Charge 425 Each
71 71 All as per item No 70 above but 1400 sweep. 155 Each
72 72 S&F bearing of ceiling fans for ceiling fans of 1200/1400mm sweep to suit for different makes of fans of approved quality including necessary greasing complete all as specified and as directed by Engineer -in-Charge 60 Each
73 73 S&F bushes gun metal suitable for ceiling fans 1200 / 1400 mm sweep complete all as specified and as directed by Engineer -in-Charge at site. 60 Each
74 74 S & F condenser / capacitor suitable for 230 volts single phase ceiling fan 1200mm / 1400 sweep of any make and quality of capacity 2.5 MFD complete all as specified and as directed by Engineer -in-Charge 400 Each
75 75 All as per item No 74 above but 3.15 MFD. 90 Each
76 76 Painting of ceiling fan 1200/1400mm sweep AC 230 volts single phase complete in situ or at contractor workshop with synthetic enamelled white/matching paint by spraying one cost including filling of cavities after cleaning all dust and marking SM/MES NO with black enamelled paint complete all as specified and as directed by Engineer -in-Charge 400 Each
77 77 Supply & fixing ceiling fan 1200 mm sweep AC 230 volts single phase including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified and as directed by Engineer -in-Charge 30 Each
78 78 Rewinding of exhaust fan 300mm to 450mm sweep AC 230 volts single phase with super enamelled copper wire of appropriate size including packing insulating material, soldering, varnishing, assembling and testing including transportation charges to and fro from contractor's workshop complete all as specified and as directed by Engineer -in-Charge 120 Each
79 79 S&F condenser / capacitor suitable for 230 volts single phase exhaust fan 300mm to 450 sweep of any make and quality of capacity 4 MFD complete all as specified and as directed by Engineer -in-Charge 90 Each
80 80 S&F exhaust fan frame made out of MS sheet for any make and size of exhaust fan with suitable size of nuts, bolts lugs and washers complete all as specified and as directed by Engineer -in-Charge 10 Each
81 81 Painting of exhaust fan 300 to 450 mm sweep AC 230 volts single phase complete with synthetic enamelled white / grey / matching paint by spraying one coat including filling of cavities after cleaning all dust and marking SM/MES NO with black enamelled paint complete all as specified and as directed by Engineer -in-Charge 300 Each
82 82 Supply & fixing exhaust fan 300 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified and as directed by Engineer -in-Charge 12 Each
83 83 Supply & fixing exhaust fan 380 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified and as directed by Engineer -in-Charge 12 Each
84 84 Supply & fixing exhaust fan 450 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified and as directed by Engineer -in-Charge 12 Each
85 85 Supply & fixing exhaust fan fresh air 250 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified and as directed by Engineer -in-Charge 12 Each
86 86 Rewinding of wall fan 450mm sweep AC 230 volts single phase with super enamelled copper wire of appropriate size including packing insulating material, soldering, varnishing, assembling and testing including transportation charges to and fro from contractor's workshop complete all as specified and as directed by Engineer -in-Charge 60 Each
87 87 Replacement of selector switch including pulling cord of wall fan 450mm sweep AC 230 volts single phase with super enamelled copper wire of appropriate size including packing insulating material, soldering, varnishing, assembling and testing complete all as specified and as directed by Engineer -in-Charge 15 Each
88 88 S & F air circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting including making necessary electrical connection with ceiling rose complete all as specified and as directed by Engineer -in-Charge 12 Each
89 89 Overhauling, repairing, reassembling, refixing, re-installation of water heaters / geysers to their original position, making all necessary water & electric connections and testing complete all as specified and as directed by Engineer -in-Charge\nNote (i) Labour for assembling of all old/ serviceable and new parts to make the geyser in serviceable conditionshall include in this items.\n(ii) Parts renewed shall be measured and paid separately. 160 Each Job
90 90 Supply & Fixing heating element 1.5 KW (ISI marked) suitable for geyser of 25 litres capacity, horizontal or vertical type any make complete all as specified and as directed by Engineer -in-Charge. Make Dasspass 160 Each
91 91 Supply & Fixing heating element 2 KW (ISI marked) suitable for geyser of 50 litres capacity, horizontal or vertical type any make complete all as specified and as directed by Engineer -in-Charge. Make Dasspass 120 Each
92 92 Supply & Fixing thermostat, minimum 300 mm long, suitable for any make & type of geyser 25 / 50 litres capacity horizontal or vertical type complete all as specified and as directed by Engineer -in-Charge 120 Each
93 93 Supply & Fixing indicating lamp for geysers of any type make & capacity complete all as specified and as directed by Engineer -in-Charge 55 Each
94 94 M&L for painting old surfaces of geysers of 25 litres capacity of any make with one coat of paint of approved shade or tint after necessary preparation to surfaces and writing of MES Nos as approved size of letter complete all as specified and as directed by Engineer -in-Charge 15 Each
95 95 S&F of PVC connection 15 mm dia with 2 Nos brass coupling, nuts from geyser inlet / outlet, 40 cm length suitable for 15 mm bore GI pipe complete all as specified and as directed by Engineer -in-Charge 45 Each
96 96 Supply, installation testing and commissioning of storage type water heater 25 ltrs capacity vertical mounting type complete made out of CRCA outer body, copper storage tank, heating element,thermostat,thermal cut out, glass wool etc. complete including making necessary electrical connections with suitable size copper multistranded cable complete all as specified and as directed by Engineer -in-Charge 12 Each
97 97 S&F PVC insulated and PVC sheathed 3 core copper conductor flexible round cable size 23 / 0.0076 complete all as specified and as directed by Engineer -in-Charge 200 RM
98 98 S&F of chromium plated stop cock with brass spindle & with crutch or butterfly handle screwed down high pressure suitable for 15 mm bore GI tubing complete all as specified and as directed by Engineer -in-Charge 20 Each
99 99 S&F Bib taps, cast copper alloy with crutch handle, screwed for 15 mm bore dia. Iron pipe or for brass ferrule and fixed complete all as specified and as directed by Engineer -in-Charge 20 Each
100 100 S&F non-return valve, gun metal, suitable for 15 mm bore GI tubing complete all as specified and as directed by Engineer -in-Charge 20 Each
101 101 S&F pressure releasing valve ISI marked complete all as specified and as directed by Engineer -in-Charge 20 Each
102 102 Supply and fixing of plug top polycarbonate 3 pin, 16 Amps complete all as specified and as directed by Engineer -in-Charge 50 Each
103 103 Supply & fixing in repair SPN sheet metal enclosure with socket plug top and MCBs with 2 pin and earth plug and socket rated 20 Amps capacity including single pole MCB of 20 Amps complete all as specified and as directed by Engineer -in-Charge 20 Each
104 104 S & F MCB SP, 6 to 32 Amps, B Series, 240 Volts complete all as specified and as directed by Engineer -in-Charge 15 Each
105 105 S&F GI nipple, 15 mm bore, medium grade upto 150 mm length complete all as specified and as directed by Engineer -in-Charge 30 Each
106 106 S&F GI pipe, 15 mm bore, medium grade mm length complete all as specified and as directed by Engineer -in-Charge 90 RM
107 107 S & F nipple, bend, tee, etc clamp as per site requirement complete all as specified and as directed by Engineer -in-Charge 10 KG
108 108 S & F Voltage stabilizer for automatic operation single phase intelligent Time Delay System, Compatible with Regular & Inverter ACs, Wall Mounting Cabinet Design, Energy efficient design, smart Digital Display, Built In Thermal Overload Protection Low & High Voltage Cut-off Protection, Latest IC Technology of capicit 05kVA . make -V Gaurd Cat part MOP suitable for 2.0 TR inverter AC or equivalent 15 Each
109 109 Point wiring for one light/fan point controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly and make wall surface as existing same colour complete all as specified and as directed by Engineer-in- Charge. \n 120 Per Point
110 110 Switch piano flush type of of polycarbonate, SP, 5/6 Amps, one way, complete all as specified and as directed by Engineer-in- Charge. \n 120 Each
111 111 Socket out let 2 in 1 socket 5 pin of polycarbonate , (6 Amps) flush type controlled by one switch complete all as specified and directed. 120 Each
112 112 Ceiling fan regulator electronic type deluxe 240 Volts 5 step ISI Marked as in replacement ,complete all as specified and as directed by Engineer-in- Charge. 250 Each