Repair / Maintenance Of Vcb , Rmu , Distribution Transformer , God , Isolation Transformers Including Maintenance Of Ht Over Head And Under Ground Cable And Connected Works At Af Station Bihta

Issued by Statutory Bodies & Commissions/Committees · Bihta, Bihar
Tender Value
22 Lakhs
Estimated cost
Bid Submission
31 Oct 2020
0 days left
EMD
44000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bihta → Bihar
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair / Maintenance Of Vcb , Rmu , Distribution Transformer , God , Isolation Transformers Including Maintenance Of Ht Over Head And Under Ground Cable And Connected Works At Af Station Bihta

BOQ

Name of Work : REPAIR / MAINTENANCE OF VCB, RMU, DISTRIBUTION TRANSFORMER, GOD, ISOLATION TRANSFORMERS INCLUDING MAINTENANCE OF HT OVER HEAD AND UNDER GROUND CABLE AND CONNECTED WORKS AT AF STATION BIHTA
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Excavating in trenches, not exceeding. 1.5metre wide and not exceeding 1.5metre deep and getting out in soft / loosecomplete all as specified and directed by Engineer-in-Charge.1203PER CUBIC METRE
22Returning filling in foundation / trenches including spreading leveling, watering and well ramming in layers not exceeding 25cm thick in soil complete all as specified and directed by Engineer-in-Charge.2180PER CUBIC METRE
33Removal of surplus excavated material to a distance n.exc. 50 metre and depositing where directed at a level n.exc. 1.5 metre above starting point complete all as specified and directed by Engineer-in-Charge.323PER CUBIC METRE
44Supply and spreading clean and dry screened sand (unwashed) in trenches around the cable for cushioning complete all as specified and directed by Engineer-in-Charge.\nNote :- Punned thickness shall be measured.472PER CUBIC METRE
55Providing, plain cement concrete 1:4:8 type D-2, (using 40 mm graded crushed stone aggregate) as in mass concrete, filling and foundation etc complete all as specified and directed.\n51PER CUBIC METRE
66Providing, plain cement concrete 1:3:6 type B1, (20mm graded crushed store aggregate) as in mass concrete, filling and foundation etc complete all as specified and directed.\n61PER CUBIC METRE
77Laying only in trenches dry well burnt bricks obtained in protections of cable laid flat perpendicular to the direction of cable over sand cushioning for protection of cable complete all as specified and directed.71.68PER THOUSAND NUMBERS
88Supply and laying in trenches dry well burnt best class locally available sub class 'B' bricks over sand cushioning for protection of cable complete all as specified and directed.82.3PER THOUSAND NUMBERS
99Supply and fix 50 mm bore steel tubing galvanised “Light Grade” in trenches/poles, under floors, roads, along poles for protection of cables, including sealing ends all as specified.\nNote :- Clamps for fixing pipe on poles shall be measured and paid for separately under respective item of this schedule of works.925PER RUNNING METRE
1010Supply and fix 80 mm bore steel tubing galvanised “Light Grade” in trenches/poles, under floors, roads, along poles for protection of cables, including sealing ends all as specified.\nNote :- Clamps for fixing pipe on poles shall be measured and paid for separately under respective item of this schedule of works.1025PER RUNNING METRE
1111Disconnecting & taking out defective under ground cable from trenches, pole, pipe, floor, wall etc locate the fault, rectify the defect and relaying the XLPE cable under ground PVC insulated and overall sheathed aluminum conductor heavy duty 11000 volts connecting and testing complete all as directed by Engineer-in-Charge (Excavation, earth work, brick protection sand cushioning and GI pipe etc shall be measured & paid for separately).11400PER RUNNING METRE
1212Supply, laying & testing cross linked polyethylene insulated (XLPE) galvanised steel strip armoured cable with aluminum conductor, 11 KV `E’, of cross sectional area 95 Sqmm, three core (IS-7098) in trenches/through pipes/ducts or on poles road crossing etc including taking out of old Cable complete all as specified and directed by Engineer-in-Charge. \nNote :- (i) Excavation, earthwork, cable protection cover, cable joint, sand cushioning shall be measured and paid for separately under respective item of this schedule.\n(ii) Old cable, cable joint, brick cover, pipe etc shall be contractor property and necessary amount as per schedule of credit shall be deducted from contractor's due payments.12150PER RUNNING METRE
1313Material and labour for cable jointing kit for 11 KV (earthed) heat shrinkable, outdoor terminitation suitable for cross sectional area 50 to 95 Sqmm, 3 core aluminium conductor XLPE Cable including jointing material and accessories complete and cutting of old cable complete all as specified and directed by Engineer-in-Charge.\n136EACH JOB
1414Material and labour for cable jointing kit for 11 KV (earthed) heat shrinkable, indoor termination suitable for cross sectional area 50 to 95 Sqmm, 3 core aluminium conductor XLPE Cable including jointing material and accessories complete and cutting of old cable complete all as specified and directed by Engineer-in-Charge.\n146EACH JOB
1515Taking down carefully switch air break, gang operated, triple pole complete and Supply, installing, connecting and commissioning switch air break gang operated, triple pole, vertical mounted, out door type of 12 insulators, mechanically operated, mounted on insulators and steel frame, with operating mechanism and operating rod of 25mm bore GI pipe heavy grade worked from ground level, with locking arrangements including brass pad locks with key (Make. Godrej/Harrison/Link) for current rating 200 Amp at 11 KV, complete with drop out fuse set fuse carrier and fuse elements having 100 Amp at 11 KV complete all as specified and directed by Engineer-in-Charge.153EACH SET
1616Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5metre below the ground level connected to GI strip 32x6 mm by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 40 mm bore medium grade for protection of earth strip, PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways, CI frame and charcoal dust and common salt, all as shown in electrical plate No. 3 of MES SSR part-I and making test point as specified including excavation & earth work in any type of soil and connecting the earthing to an earthing point/equipment as specified and directed & testing on completion.\nNOTES : (i) The concrete pit shall be made in PCC 1:3:6 type C-1, using 20mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover.\n(ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be adjusted through deviation order \n(iii) Items includes cost of 7.5 metre earth lead strip. Any variation in length shall be adjusted through deviation order.\n(iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides162EACH SET
1717Material and labour for replacement of unserviceable/damaged cable route indicator showing \"MES HT U/G 11 KV\" and route of cable with arrow (Embossed or engraved) made of RCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) 50 mm thick reinforced with 8 mm dia TMT bar at the rate of 100 mm centre to centre in suitable shape and size 60 cm x 30 cm fixed in PCC block 1:3:6 type C-2 (using 40mm graded aggregate)(size of block 30cmx 30x15cm) of 30 cm below ground level and 30cm above ground to show clear indication of cable including painting the complete slab with red paint and marking the engraved/embosed letters/arrow with white paint complete all as directed.\nNote :- Quoted rate shall be deemed to included the cost of excavation, returning, filling and removal of excavated earth upto a distance of not exceeding 50 mtr complete.1760EACH
1818Material and labour for complete servicing of VCB Make : Siemens installed at 11 KV Sub Station No 1 near (MES Office) by using required transport including taking down old unserviceale spare parts of any nature and replace with new and making functional upto the satisfaction, working with all functions like OC, UV, EF, instant tripping on fault including testing with required instruments as per secondary injection methode complete all as directed by Engr-in-Charge. The servicing covers the following :-\n(a) Cleaning of breaker chamber\n(b) Lubrication of shutter mechanism/moving parts\n(c) Checking of shutter movement\n(d) Checking door interlocks with breaker\n(e) Checking of breaker interlocks with panel door\n(f) Checking of breaker rack in/out inside the panel.\n(g) Coiling of closing and tripping coil\n(h) Checking of gear box operation.\n(j) Checking of Test/service Aux. switch operation\n(k) Checking of tripping mechanism operation.\n(l) Spring charging limit switches operation.\n(m) Checking healthiness of three poles.\n(n) Checking of damping device and setting.\n(o) Tightness, checking of power connection.\n(p) Checking of breaker ON/OFF operation manually and electrically.\n(q) Checking of closing timings.\n(r) Checking of tripping timings.\n(s) Functional checking of all electrical and mechanical operation of brekers.\n(t) Co-ordination of relay and their testing with required testing equipment according to source incomer VCB and submit report for record.\n(g) Checking/replacement of non functional strip heaters inside the VCBs and allied works. \nNote: (i) The breaker shall be repaired through authorised dealer or representative of manufacturer Original Equipment manufacturer representative of Siemens.\n(ii) Spare parts required for repair of VCB shall be measured and paid under relevant schedule items of this schedule as supply only rates.\n(iii) After completion of repair work, VCB shall be connected to full load and testing to be carried out infront of GE (AF) Bihta / Engineer -in Charge showing all functional/operational system are working satisfactorily. \n\n \n188EACH
1919Material and labour for complete servicing of VCB Make : Areva VCB installed at different location of GE(AF) Bihta station by using required transport including taking down old unserviceale spare parts of any nature and replace with new and making functional upto the satisfaction, working with all functions like OC, UV, EF, instant tripping on fault including testing with required instruments as per secondary injection methode complete all as directed by Engr-in-Charge. The servicing covers the following :-\n(a) Cleaning of breaker chamber\n(b) Lubrication of shutter mechanism/moving parts\n(c) Checking of shutter movement\n(d) Checking door interlocks with breaker\n(e) Checking of breaker interlocks with panel door\n(f) Checking of breaker rack in/out inside the panel.\n(g) Coiling of closing and tripping coil\n(h) Checking of gear box operation.\n(j) Checking of Test/service Aux. switch operation\n(k) Checking of tripping mechanism operation.\n(l) Spring charging limit switches operation.\n(m) Checking healthiness of three poles.\n(n) Checking of damping device and setting.\n(o) Tightness, checking of power connection.\n(p) Checking of breaker ON/OFF operation manually and electrically.\n(q) Checking of closing timings.\n(r) Checking of tripping timings.\n(s) Functional checking of all electrical and mechanical operation of brekers.\n(t) Co-ordination of relay and their testing with required testing equipment according to source incomer VCB and submit report for record.\n(g) Checking/replacement of non functional strip heaters inside the VCBs and allied works. \nNote: (i) The breaker shall be repaired through authorised dealer or representative of manufacturer Original Equipment manufacturer representative of Siemens.\n(ii) Spare parts required for repair of VCB shall be measured and paid under relevant schedule items of this schedule.\n(iii) After completion of repair work, VCB shall be connected to full load and testing to be carried out infront of GE (AF) Bihta / Engineer -in Charge showing all functional/operational system are working satisfactorily. \n196Each Job
2020Material and labour for complete servicing of VCB Make : ABB VCB at different location of GE(AF) Bihta station by using required transport including taking down old unserviceale spare parts of any nature and replace with new and making functional upto the satisfaction, working with all functions like OC, UV, EF, instant tripping on fault including testing with required instruments as per secondary injection methode complete all as directed by Engr-in-Charge. The servicing covers the following :-\n(a) Cleaning of breaker chamber\n(b) Lubrication of shutter mechanism/moving parts\n(c) Checking of shutter movement\n(d) Checking door interlocks with breaker\n(e) Checking of breaker interlocks with panel door\n(f) Checking of breaker rack in/out inside the panel.\n(g) Coiling of closing and tripping coil\n(h) Checking of gear box operation.\n(j) Checking of Test/service Aux. switch operation\n(k) Checking of tripping mechanism operation.\n(l) Spring charging limit switches operation.\n(m) Checking healthiness of three poles.\n(n) Checking of damping device and setting.\n(o) Tightness, checking of power connection.\n(p) Checking of breaker ON/OFF operation manually and electrically.\n(q) Checking of closing timings.\n(r) Checking of tripping timings.\n(s) Functional checking of all electrical and mechanical operation of brekers.\n(t) Co-ordination of relay and their testing with required testing equipment according to source incomer VCB and submit report for record.\n(g) Checking/replacement of non functional strip heaters inside the VCBs and allied works. \nNote: (i) The breaker shall be repaired through authorised dealer or representative of manufacturer Original Equipment manufacturer representative of Siemens.\n(ii) Spare parts required for repair of VCB shall be measured and paid under relevant schedule items of this schedule.\n(iii) After completion of repair work, VCB shall be connected to full load and testing to be carried out infront of GE (AF) Bihta / Engineer -in Charge showing all functional/operational system are working satisfactorily. \n202Each Job
2121Supply only Spring Drum Cat part No 1VYN300950-20215Each
2222Supply only Spring Cat part No GCE9478006P0102225Each
2323Supply only Roller Chain Cat part No 1VYN400950-088233Each
2424Supply only Curve Washer (RHS) New Cat part No GCE7004135R0101243Each
2525Supply only Curve Washer (LHS) NEW Cat part No GCE7004136R0101253Each
2626Supply only Stop Washer Cat part No GCE7006075P0101264Each
2727Supply only D-Shaft Cat part No 1VYN400950-104272Each
2828Supply only Cam Disc Cat part No GCE7001923P0101282Each
2929Supply only Half Shaft Cat part No 1VYN400950-106292Each
3030Supply only Torsion Spring Cat part No 1VYN400950-006303Each
3131Supply only Torsion Spring Cat part No 1VYN400950-064313Each
3232Supply only Counter Cat part No GCE9577554P0100322Each
3333Supply only Blocking Crank Cat part No GCE7003097P0101332Each
3434Supply only Blocking Crank Cat part No GCE7003097P0102342Each
3535Supply only Locking Roller Cat part No 1VYN400950-164352Each
3636Supply only Sprocket Cat part No 1VYN400950-115362Each
3737Supply only Latch Cat part No 1VYN400950-116372Each
3838Supply only Torsion Spring Cat part No 1VYN400950-002382Each
3939Supply only Charging Lever Cat part No 1VYN400950-114392Each
4040Supply only Roller Bearing Cat part No 1VYN400950-077402Each
4141Supply only Torsion Spring Cat part No 1VYN400950-010412Each
4242Supply only Retaining Washer Cat part No GCE0418316P0100422Each
4343Supply only Lever Assembly Cat part No 1VYN400901-R432Each
4444Supply only Torsion Spring Cat part No 1VYN400950-009442Each
4545Supply only. Torsion Spring Cat part No 1VYN400950-004452Each
4646Supply only Shaft Cat part No 1VYN300950-013462Each
4747Supply only Control Washer Cat part No GCE7001917P0101472Each
4848Supply only Compression Spring Cat part No 1VYN400950-001482Each
4949Supply only Stop Cat part No 1VYN400950-136492Each
5050Supply only Motor - 220V DC/AC Cat part No 1VYN300951-002 (GCE0940084P0106)502Each
5151Supply only Motor Cut Off Switch Cat part No HAGT444559P2512Each
5252Supply only Sprocket Wheel Cat part No 1VYN400950-208522Each
5353Supply only Torsion Spring Cat part No 1VYN400950-003532Each
5454Supply only Ratchet Plate Cat part No GCE9478400P0101542Each
5555Supply only Torsion Spring Cat part No 1VYN400950-005552Each
5656Supply only Retaining Circlip Cat part No GCE0418205P0100562Each
5757Supply only On-Off Indicator (Display) Cat part No GCE7001910P0101576Each
5858Supply only Shaft Cat part No 1VYN300950-030582Each
5959Supply only Tripping/Closing Coil-110V DC Cat part No 1N54450007-M592Each
6060Supply only Pin Plug Assembly Cat part No IN26570001-AM601Each
6161Supply only Emergency Trip Assembly Cat part No IVYN400901-AF611Each
6262Supply only Connection Piece Cat part No 1VYN400950-204622Each
6363Supply only Aux. Switch Cat part No 1VYN300950-064633Each
6464Supply only Contact System For VD4-630 A (12 Finger) Cat Part No. GCE8385888R0102643Each
6565Supply only Aluminimum Contact Arm Assembly for VD4 CB(800A) Cat part No GCE700142R0119653Each
6666Supply only Copper.Contact Arm Assembly VD4 CB Cat part No GCE7001421R0101663Each
6767Supply only Contact System For VD4-1250 A(DIA.34 &24 Finger) VD4 Cat part No GCE8385888R0101.673Each
6868Supply and fix in replacement of unsv/melted sleeved copper bus bar 800Amps for interconnection between siemens -3 Nos breakers + 1 No bus coupler including replacement of suitable size of steel nuts, bolts & washers etc complete all as specified and as directed.684Each Set of 3
6969Supply and fix Racking trey stand of suitable size for racking of VD 4 breaker In/Out. The size of racking shall be as per manufacturers instruction.691Each
7070Supply and fix space heater 0.5kw, 230v AC suitable for VCB alongwith suitable size of thermostat for instant tripping.7012Each
7171Material and labour for complete servicing of RMU Make : ABB installed at various 11 KV Sub Stations at AF Stn Bihta by using required transport including taking down old unserviceale spare parts of any nature and replace with new and making functional upto the satisfaction, working with all functions like OC, UV, EF, instant tripping on fault including testing with required instruments complete all as directed by Engr-in-Charge. The serviing covers the following :-\n(a) Cleaning of breaker chamber\n(b) Checking of closing and tripping coil\n(c) Checking of Test/service Aux. switch operation\n(d) Checking of tripping mechanism operation.\n(e) Spring charging limit switches operation.\n(f) Checking healthiness of three poles.\n(g) Tightness, checking of power connection.\n(h) Checking of breaker ON/OFF operation manually and electrically.\n(j) Checking of closing timings.\n(k) Checking of tripping timings.\n(l) Functional checking of all electrical and mechanical operation of brekers.\n(m) Co-ordination of relay and their testing with required testing equipment according to source incomer VCB.\nNote: The breaker shall be repaired through authorised dealer or the representative of OEM manufacturer of ABB.\nLocation : Sub Stn No 2, ATC Sub Stn, TC P/H Sub Stn & Sub Stn No 5 \nNote : (a) Spare parts required for repair of RMU shall be measured and paid under relevant items of this schedule at supply only rates.\n(b) After completion of repair work, RMU shall be connected to full load and testing to be carried out infront of GE (AF) Bihta / Engineer - in - Charge showing all functional/operational system are working satisfactorily. \n714Each Job
7272Supply only Bushing 400 Series Bolted Type Cat part No NHP201699R1 Make : ABB7212Each Set 3
7373Supply only O' Ring 72x6 Bushing 400 series bolted Cat Part No NHP402076P15 Make : ABB7312Each Set 3
7474Supply only Trip coil safeo force Amplifier Cat No 1VDP000142R1 Make : ABB744Each
7575Supply only Supply and fix VPIS unit, 9-15 kv type, Cat No YN1V400916-587 Make : ABB751Each
7676Supply only Supply and fix Relay Make : Ashida Cat No 4200013670761Each
7777Material and labour for scrpping outer/inner body of VCB/RMU and rusted patch by using super emery paper and remove the dust particles, using any cleaning agent, applying two coats of syntetic enamel paint or spray paint as per latest technology and colour code IEC Standards of 11 KV VCB including re-writing of SM/MES No complete all as specified andas directed.7710Each Job
7878Supply and fix digital COS? Meter ,Make –Conzerv ,C.l-1.0,Aux.Supply- 80-240V AC/DC.781Each
7979Supply and fix digital Ampere Meter Make –Conzerv,C.l- 1.0. Aux.Supply- 80-240V AC/DC.791Each
8080Supply and fix digital Volt Meter Make –Conzerv,C.l- 1.0. Aux.Supply- 80-240V AC/DC.801Each
8181Supply and fix Numerical O/C & E/F Relay , Aux.Supply- 80-240V AC/DC.\nCT- 5-1A., Cat part No ADR141C.\n811Each
8282Supply and fix VAA 33 Aux.3 Element Relay ,Aux.Supply 30V DC,06 ON Contacts,821Each
8383Supply and fix VAJH13 Master trip relay ,Make- Alstom, Aux.Supply 30V DC.04 ON Contacts & 01NC Contacts831Each
8484Supply and fix in replacement of damaged/unsv CT of Ratio – 60/5+5A,VA-7.5VA,5P10,C.l-1.0 Make- NPP,Power Foil,\n841Set of 3
8585Supply and fix in replacement of damaged 3 Phase PT of ratio – 11KV/110V ,VA-100,C.l-1.0. suitable for existing model VCB Make- NPP,Power Foil.851Each Set
8686Supply and fix Bus bar insulator as per existing size model.suitable for HT 11000 volts.863Set of 3
8787Supply and fix fire retardant/extinguishing Elect Insulated mat of 2.5mm thick (+10%) according to IS : 15625:2006, meeting requirements of IS :3043, IS:5216 (Part 1,2 & 3), IS:8437 and IEC 479 Pub-I, tested for breakdown strength, tensile/elongation, ageing properties, Insulations resistance, effects of acid, alkaline, diesel & transformer oil, leakage current test, fire test etc having min width of 1000mm + 20mm. All allied material such as pu-resin, chemi bound (hardener), spl. PVC adhesive, liquid primer and sealing material and similar tape of matching colour and matching design tapes should be used to maintain any aesthetic look of the insulation over the joints and corner as per in service recommendation of Annexure 'A' Clause 'C' of IS 15652 and suitable for Class-B upto 11 KV with HT Trolley movement. (4 Power House)8725Sqm
8888Power Pack unit with ON Line UPS, sealed maintenance free type with battery bank along with electronic on line power pack 1500VA required for maintaining 110 volts DC at the mode power failure from State Elect Board having special features. Main supply: (140V-270V) Single phase, output voltage: 110V DC+/- 0.5% loaded current, Overload: 110% of rated load, Power Factor: >90%, Bsck up period: 360 minutes with standard Battery Selection. Indications: Mains, Emergency, over laod,reverse polarity battery charging with power pack ON/OFF switch complete all as specified and as directed.\nMake: PARTNER/Master Power Control/Standard/AMCO,and make of battery Exide or equilavent make as specified in Appendix `B` to particular specification.881Each
8989Material and labour for fabrication of LED display board made of perflex sheet of size 3.2m x 2.5 m including writing letters as ''11 KV RECEIVING STATION, GARRISON ENGINEER (AF) BIHTA'' Phone - 06115- 6115250028 including provision of LED strip all around the board, inside LED light having sufficient lighting etc complete all as specified and as directed. The board shall have support with angle iron of size not less than 50x50x6mm thick to withstand wind pressure etc. \nNote : The Contractor shall quote his rates inclusive of cost of farbrication and other minor spares like nuts, bolts and washers etc.891Each Job
9090Supply and hanging all type of precautionary electrical charts in English and Hindi Language complete all as directed at site.906Each Job
9191Supply and fix HT 11 KV PT out door type for secondary metering system at 11 KV Receiving station /four pole structure including fixing of suitable size of channels at four pole structure, fixing etc, making necessary electrical connection with suitable size of aluminium conductor/copper wire and other allied accessories into HT 11 KV 3 phase meter system complete all as specified and as directed.911Each Job
9292Material and labour for fabrication and fixing of Retro reflective sign board green in colour to increase the night time conspicuity for indication of sub stations for effective visible during night timings, writing letters on white of suitable size and thickness ''11 KV SUB STATION'' under AGE E/M Bihta, GE (AF) Bihta, including fixing on wall with the help of hole fastner, steel nuts, bolts and washers etc complete all as directed. The size of board shall not less than 0.9 x 0.9 mtr supporting with angle iron frame and hanging hook etc.929Each
9393Supply and fix HT Check metering box of size not less than 900x900x900mm, factory made, outdoor pedestal type, double door, fabricated out of 3.15 mm thick CRCA sheet and angle iron frame 50x50x6mm sloppy roof locking arrangement comprising 50mm size Godrej brass pad lock with duplicate keys two earth terminal, suitable cable gland for incoming and outgoing HT cable and protection of joint, grouting of feeder pillar box by providing 90 cm long angle iron of size 50 x 50 x 6mm welded on all the four cornors embedded in platform not less than 1 mtr height. All sheet steel metal works including frame shall be with anticorrosive coating with seven tank process and finally expoxy polyster powder coating of flint grey shade. The panel shall have copper bus bar three strips of minimum size 200mm x 50mm x 10mm with procelain H12 KV HT long insulator complete including fixing 3 phase digital HT Trivector meter (CMRI) and suitable size of CTs, 3 Ph 4 wire TVM 110V(L-L) 1A Class 0.2s BM RS458, Meter reading instrument (16.5MB) (Cat part No 990MRIXX000 of L&T, Meter Optical port to USB cable (Cat part No 990PCXXUSB of L&T make or equivalent in /Schneider/Secure\nNote :- (i) Quoted rate shall be deemed to include the cost of platform upto the height of 0.6 mtr brick wall for mounting of panel as specified in particular specifications.\n(ii) Quoted rate shall also deemed to include the software of Meter Reading Instrument and leather pouch of the instrument. \n931Each Job
9494Boring of holes under road, pavement, hard standing by trenchless technology by mechanical method using ultra sounding technique without damaging the surface suitable for 150 mm bore including 150 mm bore HDPE pipe 0.4 mpa working pressure complete all as specified and as directed by Engineer-in-Charge. \nNote :-(i) Depth of hole shall be 0.5 to 0.9 metre below the top surface of road / pavement / hard standing /Path.\n(ii) Cost of pipe shall be deemed to be included in the unit rate quoted by tenderer9450PER RUNNING METRE

AI Tender Summary

OUR REF NO 25688996
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 22 Lakhs
LAST DATE 31-10-2020
Authority
Authority Name Military Engineer Services
Work Description Repair / Maintenance Of Vcb , Rmu , Distribution Transformer , God , Isolation Transformers Including Maintenance Of Ht Over Head And Under Ground Cable And Connected Works At Af Station Bihta
Basic Detail
Tender No 87101/C/E8
Bidding Type Tender
Location
City Bihta
State Bihar
Key Dates
Publish Date 10 Oct 2020
Submission Date 31 Oct 2020
Open Date 02 Nov 2020
Finance
Tender Value 22 Lakhs
Tender Fee 500
EMD 44000
Exemption Not Available
Document List
496B2867-F5AC-49A7-8990-2C4757DFF1E9.html
Tender.rar
Tendernotice_1.pdf
BOQ_429778.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 10, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 31, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 02, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

496B2867-F5AC-49A7-8990-2C4757DFF1E9.html

rar

Tender.rar

pdf

Tendernotice_1.pdf

xls

BOQ_429778.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender